A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy.

PURPOSE: A prototype scanner for large-volume megavoltage computed tomography (MVCT) in a clinical set-up is described. The ultimate aim is to improve treatment accuracy in conformal radiotherapy through patient set-up error reduction and transit dosimetry. MATERIALS AND METHODS: The scanner consists of a custom-built 2D CsI(Tl) crystal array viewed by a lens and a CCD camera. Image acquisition is synchronized with radiation pulses. The 2D projections resulting from a single continuous 360 degrees gantry rotation are reconstructed using a cone-beam tomography algorithm. Prior to reconstruction, the raw projections are calibrated and corrected for centre of rotation movement and accelerator output fluctuation. The performance of the system has been evaluated by reconstructing projections of open fields, test objects and a humanoid phantom. RESULTS: Hundreds of 2D projections can be acquired with a clinically-acceptable data collection time (about 2 min) and dose (approximately 40 cGy, with a possible four-fold reduction). A maximum density resolution of about 2% is achieved offering some soft tissue discrimination without using image enhancement tools. A spatial resolution of 2.5 mm is obtained. The reconstructed image intensity is linear with electron density over the range of interest. Coronal or sagittal slices through the 3D reconstruction of the humanoid phantom show a better delineation of structures than the corresponding portal images taken at the same orientation. CONCLUSIONS: A similar image quality to our current single-slice MVCT scanner is achieved with the advantage of providing tens of tomographic slices for a single gantry rotation. This work demonstrates the feasibility of clinical cone-beam MVCT and indicates how this prototype can be improved.

Image Processing, Computer-Assisted↗

Optimization of the scintillation detector in a combined 3D megavoltage CT scanner and portal imager.

A parametric study is described leading to the optimization of a custom-made scintillation detector with a relatively high quantum efficiency (QE) for megavoltage photons and light output toward a remote lens. This detector allows low-dose portal imaging and continuous cone-beam megavoltage CT acquisition. The EGS4 Monte Carlo code was used to simulate the x-ray and electron transport in the detector. A Monte Carlo model of optical photon transport in a detector element was devised and used as well as various irradiation experiments on scintillators. Different detector materials and configurations were compared in terms of the optical photon irradiance on the lens from on- and off-axis detector elements and the practical constraints regarding detector construction and weight. Effects of scintillator material, detector element size, crystal coating type, and reflectivity, combinations of different coatings on detector faces, scintillator doping level, and crystal transparency were studied. With scintillator thickness adjusted to give an 18% x-ray QE at 6 MV, the light output of CsI(Tl) was at least eight times higher than ZnWO4, BGO and NE118 plastic. Further, CsI(Tl) showed the smallest decrease in QE going from 6 to 24 MV. The off-axis reduction in emittance from the periphery of the detector was relatively small with a slight dependence on the type and reflectivity of the coating and the crystal thickness for a fixed detector element cross section. Light output was more strongly dependent on the reflectivity of lambertian coatings than specular ones. For a fixed detector element cross section, optimum coating type depended on crystal thickness. Typical CsI(Tl) crystals showed a relatively small variation in light output with changes in optical attenuation length. The optimum detector element was found to be CsI(Tl) coated on five faces with TiO2-loaded epoxy resin offering about a ten-fold improvement in light output per incident photon compared to typical metal/phosphor screens.

Biophysical Phenomena↗

Rapid portal imaging with a high-efficiency, large field-of-view detector.

The design, construction, and performance evaluation of an electronic portal imaging device (EPID) are described. The EPID has the same imaging geometry as the current mirror-based systems except for the x-ray detection stage, where a two-dimensional (2D) array of 1 cm thick CsI(Tl) detector elements are utilized. The approximately 18% x-ray quantum efficiency of the scintillation detector and its 30 x 40 cm2 field-of-view at the isocenter are greater than other area-imaging EPIDs. The imaging issues addressed are theoretical and measured signal-to-noise ratio, linearity of the imaging chain, influence of frame-summing on image quality and image calibration. Portal images of test objects and a humanoid phantom are used to measure the performance of the system. An image quality similar to the current devices is achieved but with a lower dose. With approximately 1 cGy dose delivered by a 6 MV beam, a 2 mm diam structure of 1.3% contrast and an 18 mm diam object of 0.125% contrast can be resolved without using image-enhancement methods. A spatial resolution of about 2 mm at the isocenter is demonstrated. The capability of the system to perform fast sequential imaging, synchronized with the radiation pulses, makes it suitable for patient motion studies and verification of intensity-modulated beams as well as its application in cone-beam megavoltage computed tomography.

Equipment Design↗

Dosimetric evaluation of compensation in radiotherapy of the breast: MLC intensity modulation and physical compensators.

BACKGROUND AND PURPOSE: Electronic portal images may be used to design the compensation required to maximise dose uniformity in the breast from opposed tangential beams. MATERIALS AND METHODS: Four methods of implementing the desired compensation have been studied: a simple wedge, a physical compensator in conjunction with a wedge; one open field plus four shaped multi-leaf-collimated (MLC) fields, and one wedged field in conjunction with three shaped MLC fields. Evaluation was performed using thermoluminescent dosimeters (TLDs) placed inside a phantom which was designed to mimic the human breast. The measured results are compared with both the prediction of the in-house compensation design software and with the dose predicted by the GE Target II planning system. The implications of each method for the time taken to plan and deliver treatment were analysed. RESULTS: The dose inhomogeneity, as measured at seven points in the central plane was greatest for the simple wedge (root mean square (rms) = 4.5%) compared to an open field plus four shaped MLC fields (rms = 2.2%), a wedged field plus three shaped MLC fields (rms = 3.3%), and the physical compensator (rms = 2.4%). The times required to plan and prepare these treatments varied considerably. The standard wedged treatment required under 15 min; both MLC-based and the physical compensator treatments required approximately 50 min. Differences of treatment delivery times were up to 8 min. CONCLUSIONS: These results indicate that the dose inhomogeneity can be reduced by beam intensity modulation designed using EPIDs.

Breast↗

Extraction of primary signal from EPIDs using only forward convolution.

A model is presented in which the scatter signal in images obtained obtained by electronic portal imaging devices (EPIDs) is removed by a forward convolution method. The convolution kernel, kt(r) is a cylindrically symmetric kernel, generated by Monte Carlo, representing the scattered signal of a pencil beam at the image plane after the photons have gone through an object of thickness, t. A set of the kernels is presented and used to extract the primary signal. The signal from primary photons in the image, P(r), is extracted by an iterative method in which the essential assumption is that the scatter signal S(r) can be described by a superposition of the signal that would be obtained with the object removed from the beam, O(r), and the kernel kt(r). The thickness, t, that is used to choose the kernel, is directly related to P(r) by a simple exponential relationship; hence the thickness, t, of the object and the primary signal, P(r), are both iterated to better estimates through this procedure. The model is tested on Monte Carlo simulated data, where the extracted primary signal is compared with the "true" primary signal. Results are presented for a set of phantoms of uniform thicknesses up to 35 cm, and for field areas up to 320 cm(2), and for an inhomogeneous phantom containing a sphere of different density. The primary signal can be extracted to better than 1.5%, even when the original Scatter-to-Primary Ratio (SPR) is more than 25%. Finally, we have tested the model on EPID images, a nonuniform (breast) phantom is presented here. The breast phantom both have a curved external contour and contains a structure of a different density (lung). The radiological thickness of this breast phantom, as extracted using the above convolution model, was found to be within 2.8 mm (1 sd) of the true radiological thickness.

Algorithms↗

The optimum intensities for multiple static multileaf collimator field compensation.

A method of determining the optimum beam intensities for compensation using multiple static multileaf collimator fields is presented. In this method a histogram of the number of beam pixels against beam intensity is generated for the intensity-modulated beam (IMB). The intensity of each beam to be used is chosen to minimize the mean square deviation between each bin in the histogram and the closest beam intensity. This method has been applied to sample IMBs possessing one maximum and two maxima. For both cases, the use of uniform beam intensity increments is shown to be close to optimal. In the case with two maxima, the efficacy of irradiating both peaks simultaneously, rather than separately, has been studied and shown to be of potential benefit. The optimum intensities for an IMB for breast radiotherapy are also presented.

Humans↗

The application of transit dosimetry to precision radiotherapy.

A method of using electronic portal imaging (EPI) for transit dosimetry is described. In this method, a portal image of the treatment field is first aligned with a digitally reconstructed radiograph (DRR) to geometrically relate the computed tomography (CT) scan, used to generate the DRR, with the EPI. Then the EPI is corrected for scatter within the patient to yield a map of primary fluence striking the detector. This is backprojected through the planning CT data set to yield a distribution of primary fluence within the patient. This distribution is then convolved with dose deposition kemels to yield a map of dose delivery within the patient. Such a distribution may be compared with the dose distribution resulting from the original treatment plan in order to evaluate the adequacy of the treatment. This method has been evaluated using a humanoid phantom. We find the transit dosimetry relative dose distribution when compared with film and thermoluminescent dosimeter (TLD) measurements and compared with our planning system to agree within 2% in the pelvic region of a humanoid phantom.

Equipment Design↗

Scattered radiation in portal images: a Monte Carlo simulation and a simple physical model.

The scattered radiation in 6 MV radiotherapy portal images is analyzed. First, a quantity SPR* is studied, by means of Monte Carlo (MC) modeling. SPR* is defined as the ratio, on the central axis, of the signal due to scattered radiation to that due to the primary radiation. The detector model mimics a high-energy photon detector in the context of transit dosimetry. Second, a physical model of SPR* has been developed from first principles. For a cylindrical phantom, placed symmetrically about the isocenter, it predicts that SPR* depends on the area A at the isocenter of the circular field and the phantom thickness d as follows. SPR* = k0Ad(1 + k1d)(1 + k2A), where k0 = 0.0266(L1 + L2)2/(L1L2)2, k2 = - [L1(-2) + L2(-2) + (L1(-1) + L2(-1))2((2/3) + (3 kappa/2))]/2pi, L1 is the source-to-isocenter distance, L2 is the isocenter-to-detector distance, and kappa is the mean energy of the radiation beam (MeV/0.511). Constant k1, for which there is no simple expression, depends on L2. Comparison to the MC data shows that for 60 or= 50 cm. Third, experimental measurements of the scatter-to-primary ratio were obtained using our custom built imaging system mounted on a Philips SL25 linear accelerator. In the first experiment, A was varied from 40 to 400 cm2 with L1 = L2 = 100 cm with d = 20 cm. In the second experiment water depth d was varied from 0 to 28 cm with L1 = L2 = 100 cm and A = 200 cm2. The rms agreements between the MC data and the experiments were 0.0015 and 0.0045, respectively.

Biophysical Phenomena↗

Reproducibility of patient positioning during routine radiotherapy, as assessed by an integrated megavoltage imaging system.

A portal imaging system has been used, in conjunction with a movie measurement technique to measure set-up errors for 15 patients treated with radiotherapy of the pelvis and for 12 patients treated with radiotherapy of the brain. The pelvic patients were treated without fixation devices and the brain patients were treated with individually-moulded plastic shells. As would be expected the brain treatments were found to be more accurate than the pelvic treatments. Results are presented in terms of five error types: random error from treatment to treatment, error between mean treatment position and simulation position, random simulation error, systematic simulator-to-treatment errors and total treatment error. For the brain patients the simulation-to-treatment error predominates and random treatment errors were small (95% < or = 3 mm, 77% < or = 1.5 mm). Vector components of the systematic simulation-to-treatment errors were 1-2 mm with maximal random simulation error of +/- 5 mm (2 S.D.). There is much interest in the number of verification films necessary to evaluate treatment accuracy. These results indicate that one check film performed at the first treatment is likely to be sufficient for set-up evaluation. For the pelvis the random treatment error is larger (95% < or = 4.5 mm, 87% < or = 3 mm). The systematic simulation-to-treatment error is up to 3 mm and the maximal random simulation error is +/- 6 mm (2 S.D.). Thus corrections made solely on the basis of a first day check film may not be sufficient for adequate set-up evaluation.

Brain↗

Design of compensators for breast radiotherapy using electronic portal imaging.

A novel method of designing intensity modulated beams (IMBs) to achieve compensation in external beam radiotherapy of the breast, without the need for CT scans, is presented. The design method comprises three parts: (1) an electronic portal image is used to generate a map of radiological thickness; (2) this map is then used to obtain an estimate of the breast and lung outline; (3) a TMR-based dose calculation algorithm is then used to determine the optimum beam profile to achieve the best dose distribution. The dose distributions calculated for IMBs were compared with those calculated for the use of simple wedges. The results for two patients studied indicate that the dose inhomogeneity for IMBs is +/- 5%, compared with a value of +/- 10% for a wedged plan. The uncertainty in radiological thickness measurement corresponds to a dosimetric error of +/- 2%. Other errors associated with outline estimation are typically less than 2%, with a largest value of +5% for one of the patients who had a large and highly asymmetrical breast. The results for the two patients studied suggest that the uncertainties in the method are significantly smaller than the improvement in dose uniformity produced.

Algorithms↗

Noise reduction by frame averaging: a numerical simulation for portal imaging systems.

We have studied the usefulness of both pre- and post-ADC frame summing for the purpose of reducing the effect of quantum noise and digitization noise in portal imaging systems. The study is based on the fluorescent-screen video-camera type of system. The study predicts the not-surprising result that provided the noise level at the ADC input is sufficiently large, the overall SNR can be increased by a factor of square root of M1M2, where M1 and M2 are the number of frames summed before and after the ADC. The study also predicts, somewhat unexpectedly, that there is an operating region in which increasing M1 actually decreases the SNR in the final image. To avoid this region M1 must be less than approximately 6 x 2(2B) (1 + -delta-1)1/2/(iaccf), where B is the number of ADC bits, -delta is the mean number of optical photons detected by the video camera per detected x-ray photon, iacc is the open-field number of detected x-ray photons per accelerator pulse per pixel, and f is the patient transmission factor. An equivalent statement is that the rms noise at the input to the ADC, sigma in, must exceed approximately 0.4q where q is the quantization interval of the ADC. It is possible that some systems operate in or close to this region. A second feature of this anomalous behavior is that the final image is not necessarily improved by increasing the number M2 of post-ADC-summed frames. For example, when sigma in/q = 0.2, there is no improvement in the overall rms error for M2 > 32.(ABSTRACT TRUNCATED AT 250 WORDS)

Humans↗

A randomised trial of patient repositioning during radiotherapy using a megavoltage imaging system.

Effectiveness of radiotherapy is dependent on the accuracy of beam alignment. Recent developments in megavoltage imaging allow real-time monitoring of beam placement. Maximum gains from this new technology can only be made if the information is utilised to correct patient positioning prospectively before the majority of a treatment fraction is delivered. We have developed and utilised an integrated megavoltage imaging system to perform a randomised trial demonstrating significant improvements in accuracy using treatment intervention techniques for pelvic radiotherapy. The mean field-placement accuracy improved from 4.3 mm to 2 mm and the proportion of treatments given with a field-placement error of > or = 5 mm decreased from 69% to 7%. This improvement in accuracy may enable smaller margins around the target volume to be chosen whilst ensuring complete target coverage at each treatment fraction.

Aged↗

Preliminary clinical performance of a scanning detector for rapid portal imaging.

A scanning megavoltage imaging detector, with associated image storage and analysis facilities has been developed. This produces images of the treatment portals in under 10 seconds, in a digital format, facilitating rapid, quantitative image analysis. Image quality is comparable to, and at some sites improves upon, that available from film. Clinical problems in the use of megavoltage imaging include limited field of view, loss of information at the field edge due to penumbra effects, degradation of the image by bowel gas, and difficulties in the detection of soft tissue-air interfaces. Possible solutions to these problems are discussed. The imaging system has been used to assess the random errors occurring during routine para-aortic nodal irradiation. The errors detected are small, with over 95% of set-ups lying within +/- 4.5 mm of the mean daily position. No differences were detected in the magnitude of random errors between anterior and posterior treatment fields.

Aorta↗

Conformal radiotherapy at the Royal Marsden Hospital (UK).

Conformal radiotherapy seeks to allow increased intensity of radiation by reducing the volume of normal tissues within the treatment volume. Techniques have developed secondary to improvements in three-dimensional imaging and accessible treatment technology is based on computer-controlled multileaf collimators to create an irregular radiation beam shape. Preliminary clinical work in the Royal Marsden Hospital seeks to quantify the toxicity reduction achievable by conformal techniques in the context of a prospective randomized pelvic radiotherapy trial which has now recruited 240 patients. The data accumulated during this trial will allow comparison of conformal and conventional radiotherapy and also analysis of the impact of dose and volume of a particular organ on both acute and late toxicity. Assessments have revealed that conformal techniques reduced significantly the treatment volume of normal tissues, e.g. by a mean of 54% for rectum and 42% for bladder. However, a relationship between volume and acute toxicity has not been established. Late toxicity is currently being analysed. Dose escalation trials in thoracic and in pelvic tumours are planned.

Humans↗

A proof that uniform dose gives the greatest TCP for fixed integral dose in the planning target volume.

In this note it is shown that for a fixed integral dose to the planning target volume, the highest tumour control probability (TCP) arises when the dose is spatially uniform. This 'uniform dose theorem' is proved both for (i) a specific TCP model based on Poisson/independent voxel statistics, and (ii) any model for voxel control probability having a specific shape with respect to increasing dose.

Dose-Response Relationship, Radiation↗

Technical note: the implementation of patient position correction using a megavoltage imaging device on a linear accelerator.

The problem of using information from the analysis of megavoltage images to adjust patient set-up has been addressed. In the case of rotational corrections it has been assumed that the treatment head is to be adjusted, although for gantry angles of 0 degree and 180 degrees couch rotation may be used. In the case of translational shifts adjustment of the collimator jaws or of the couch have both been considered for arbitrary combinations of couch and gantry angle. For couch movement the case has been considered where it is desirable to minimize both the number of parameters to be adjusted and also the magnitude of the change in the patient's position. Values obtained for frequently used set-up parameters have been presented. Adjustment of the treatment couch positioning is the most desirable option, as this should bring the patient closer to the correct position for subsequent treatment fields. However, rotational errors are not correctable for all gantry angles and furthermore the collimator settings may be set more accurately than those of the treatment couch. Hence, in some cases, adjustment of the collimation system may be desirable or necessary. The formulae given in Equations (13) to (18) are currently being used in an intervention study to correct patient set-up during the course of a treatment fraction.

Humans↗

A megavoltage CT scanner for radiotherapy verification.

We have further developed a system for generating megavoltage CT images immediately prior to the administration of external beam radiotherapy. The detector is based on the scanner of Simpson (Simpson et al 1982)--the major differences being a significant reduction in dose required for image formation, faster image formation and greater convenience of use in the clinical setting. Attention has been paid to the problem of ring artefacts in the images. Specifically, a Fourier-space filter has been applied to the sinogram data. After suitable detector calibration, it has been shown that the device operates close to its theoretical specification of 3 mm spatial resolution and a few percent contrast resolution. Ring artefacts continue to be a major source of image degradation. A number of clinical images have been presented. The next stage of this work is to use the system to make clinical measurements of patient set-up inaccuracies building on our work making such measurements from digital portal images (Evans et al 1992).

Evaluation Studies as Topic↗

Image comparison techniques for use with megavoltage imaging systems.

In this paper we describe software facilities for enabling patient positioning studies using the megavoltage imaging system developed at the Royal Marsden Hospital and Institute of Cancer Research. The study focuses on the use of the system for three purposes: patient position verification (by comparing images taken at treatment simulation with megavoltage images taken at treatment time); reproducibility studies (by analysing a set of megavoltage images); and set-up correction (by adjusting the set-up until the megavoltage image obtained at treatment registers with the simulation image). The need is discussed for suitably presented simulator images, a method of determining field boundaries and the possibility of delineating soft-tissue interfaces. Several algorithms of different types, developed specifically for the purpose of intercomparison of planar projection images, are presented. The techniques employed and their usefulness, in both the qualitative and the quantitative sense, are discussed. The results are presented of a phantom and clinical study, to evaluate the rigour and reproducibility of the algorithms. These results indicate that measurements can be made to an accuracy of about 1-2 mm, with a similar value for interobserver reproducibility for the best image comparison techniques available.

Algorithms↗