Coincidence in high-speed flow cytometry: models and measurements.

In flow cytometry, the coincident arrival of particles becomes a major problem when high sample rates are required. For the development of our high-speed photodamage flow cytometer (ZAPPER), it was of importance to understand the behavior of cells at flow rates of around 50,000-250,000 event/s. We developed and compared two models that describe the relation between the real cell rate and the detectable single cell rate. Both the Computer Simulation model and the Input/Output Device model show distinct optima for the cell rate. The models were compared to measurements performed on the ZAPPER-prototype. Fits of the two models to the experimental data were excellent for cycle times of 4 and 15 microseconds and acceptable for a 2 microseconds cycle time. A third model (Mercer WB, Rev. Sci. Instr. 37:1515-1521,1966) could be fitted to the experimental data, after the proportionality constant k was adapted to the experimental data. At a yield of detectable single cells of 70%, the maximum cell rates are 180,000, 100,000, and 40,000 cells/s for cycle times of 2, 4, and 15 microseconds, respectively. Based on these results we can now select an optimal cell rate for analysis and sorting based on criteria such as accepted cell loss. In addition, the advantages of reducing the cycle time can now be evaluated with respect to the costs of that modification.

Cell Separation

Parallel processing data acquisition system for multilaser flow cytometry and cell sorting.

This report describes the data acquisition electronics for a flow cytometer. The design differs from most instruments in that the signals from a large number of detectors are processed in parallel. Each of the input channels is capable of autonomously measuring and digitizing the fluorescence signals. The digitized values that belong to one particle are collected by digital circuitry and are presented as a compact data package on a special bus. In addition to the pulse values, the data package contains a time marker, information needed for sort decisions, and an error detection code. Specially designed electronic modules that read the information from the bus can take complex multiparameter sort decisions at a very high speed. All events can also be recorded as data lists by a computer. The lists can be used to reconstruct a sort or analysis run. The raw data lists can also be reduced to kinetic curves and/or (gated) multivariate histograms. As a result of the applied scheme of parallel pulse processing, the dead time of the system is independent of the number of parameters measured and the number and time separation of the excitation beams. The instrument has a cycle time of 5 microseconds, which corresponds to a throughput rate of 2 x 10(5) events/s. At this rate, the incidence of correlation errors is well below 1 in 10(8) analyzed particles. The system has proved to be reliable and convenient to use in a variety of experiments. Its high speed and low error rate make it well suited for high-resolution measurements, rare-event analysis, kinetic measurements, and high-speed cell sorting.

Electronic Data Processing

Optical plankton analyser: a flow cytometer for plankton analysis, II: Specifications.

An analysing flow cytometer, the optical plankton analyser (OPA), is presented. The instrument is designed for phytoplankton analysis, having a sensitivity comparable with commercially available flow cytometers, but a significantly extended particle size range. Particles of 500 microns in width and over 1,000 microns in length can be analysed. Sample flow rates of up to 55 microliters/s can be used. Also, the dynamic range of the instrument is significantly increased for particles larger than about 5 microns. The optics, hydraulics, and electronics of the instrument are described, including the best form for a low fluid shear cuvette. The new pulse quantification technique we call digital integration is presented. This technique is essential for the instrument to handle both short and very long particles with a large dynamic range. Test measurements demonstrating particle size range and dynamic range are presented. Dynamic ranges of 10,000 and 100,000 were typically observed, measuring field samples with Microcystis aeruginosa colonies, whereas one sample showed a dynamic range of 10(6). A simple method for interpretation of time of flight (TOF) data in terms of particle morphology is presented. The specifications of the instrument are given.

Electronic Data Processing

Effect of cyclosporin A on daunorubicin accumulation in multidrug-resistant P388 leukemia cells measured by real-time flow cytometry.

We investigated the mode of action of cyclosporin A (Cy-A) as a modifier of multidrug resistance in P388 mouse leukemia cells. A fluorescence-activated flow cytometer (FCM) was modified with a flow-through cuvette to allow continuous on-line monitoring of daunorubicin uptake in vitro. The addition of Cy-A to multidrug-resistant P388/R cells at steady-state daunorubicin uptake, led to a dose-dependent increase in cellular daunorubicin accumulation, as measured by FCM and high-performance liquid chromatography (HPLC). A linear relationship was found between the daunorubicin concentration in the incubation medium and the Cy-A concentration required for optimal stimulation of cellular anthracycline accumulation. The results of a cytotoxicity assay indicated that Cy-A completely restored the chemosensitivity of the P388/R cells. Intracellular Cy-A measurements in P388/S and P388/R cells showed that P388/R cells accumulated significantly less Cy-A than P388/S cells. Relatively high daunorubicin concentrations could not restore that accumulation defect. These results suggest that Cy-A promotes cellular anthracycline accumulation by competing for an outward drug-transport system that operates in multidrug-resistant cells.

Animals

High-speed photodamage cell selection using bromodeoxyuridine/Hoechst 33342 photosensitized cell killing.

One of the major drawbacks of droplet sorting in a flow cytometer is the relatively low sorting speed. Thus, we have developed an alternative, faster sorting technique: photodamage cell sorting. In a photodamage cell sorter all unwanted cells, as detected with the first, measuring laser, are killed with the second, damaging laser. Thus, the cells need to be photosensitive to the second laser. In addition, a mechanism is needed to switch this laser on and off based on the sorting criteria. In our photodamage cell sorter, the ZAPPER, we use an acousto-optic crystal to switch the laser beam. Cells are made photosensitive by vital staining with photosensitizers. With cells grown in the presence of 5-bromo-2'-deoxyuridine (BrdUrd) and stained with Hoechst 33342 (H42) at least a 5-decade cell reduction is accomplished after irradiation with 400 mW UV light. With this system, sorting rates have been achieved of 30,000 cells per second. Due to the selection based on photodynamic killing, this sorting technique is restricted to the selection of viable cells. Photodamage cell sorting seems well suited for isolating viable cells occurring in low percentages or for the sorting of large numbers of cells. Another application can be the sorting of large or fragile cells.

Animals