Search PubMed⌕ Search

Biomedical subjects

W Sibbett

Publications and source records attributed to W Sibbett.

13 recordsLinked to original sources

Quantum-dot-based saturable absorber for femtosecond mode-locked operation of a solid-state laser.

A quantum-dot-based saturable absorber has been demonstrated to initiate the generation of femtosecond pulses from a passively mode-locked solid-state laser. Control and tuning of the pulse duration from 58 ps to 158 fs was achieved. The 158 fs transform-limited pulses at 1280 nm are the shortest pulses that were produced from the Cr:forsterite laser passively mode locked by an InAs/InGaAs quantum-dot semiconductor saturable absorber mirror.

Journal Article↗

Ambulatory photodynamic therapy: a new concept in delivering photodynamic therapy.

BACKGROUND: Photodynamic therapy (PDT) has been shown to be effective in treating Bowen's disease, superficial basal cell carcinoma and actinic keratosis. OBJECTIVES: To investigate the feasibility of delivering PDT using a portable light-emitting diode device. METHODS: A prototype diode array, comprising 37 AlGaInP diodes cast in epoxy with a diffuser, and driven by a battery pack, was designed and constructed. A pilot study was carried out in five patients with histologically proven Bowen's disease who were referred for PDT with 5-aminolaevulinic acid. They were all treated in the hospital-based dermatology PDT suite such that each received the same level of supervision as patients receiving PDT with nonambulatory light sources. Patients recorded pain levels. In accordance with our usual practice, patients received two treatments at a 4-week interval. RESULTS: Four of five patients were clear at follow-up (range 6-13 months, median 9). Pain was classified as none or mild in 80% of treatments and moderate in the remainder. CONCLUSIONS: There are many potential benefits of ambulatory PDT, including the possibility of a much higher patient throughput, and allowing effective treatment at home. This pilot study provides early promising data of the safety and efficacy of this approach.

Ambulatory Care↗

Yb3+-doped YVO4 crystal for efficient Kerr-lens mode locking in solid-state lasers.

We report the first demonstration, to our knowledge, of soft-aperture Kerr-lens mode locking in a diode-pumped femtosecond Yb3+:YVO4 laser. Near-transform-limited pulses as short as 61 fs are generated around a center wavelength of 1050 nm with an output power of 54 mW and a pulse repetition frequency of 104.5 MHz. This is, to our knowledge, the shortest pulse generated directly from an Yb laser having a crystalline host material. The femtosecond operation has a mode-locking threshold at an absorbed pump power of 190 mW. The nonlinear refractive indexes of the Yb3+:YVO4 crystal have been measured to be 19 x 10(-16) cm2/W and 15 x 10(-16) cm2/W for the sigma and pi polarizations, respectively, at 1080 nm.

Journal Article↗

Efficient femtosecond green-light source with a diode-pumped mode-locked Yb3+:KY(WO4)2 laser.

Efficient generation of femtosecond pulses at 524 nm is demonstrated by the extracavity frequency doubling of the output of a diode-pumped femtosecond Yb3+:KY(WO4)2 laser using a periodically poled LiTaO3 crystal. An average second-harmonic power of 120 mW is produced at an internal conversion efficiency of 40%. The temporal characteristics of the frequency-doubled pulses as a function of focusing conditions in a thick nonlinear crystal are investigated experimentally, and pulses as short as 225 fs are generated at a pulse repetition frequency of 86 MHz.

Journal Article↗

Highly efficient blue-light generation from a compact, diode-pumped femtosecond laser by use of a periodically poled KTP waveguide crystal.

We present a simplified, potentially portable, and highly efficient blue-light source from a periodically poled KTP waveguide crystal with a compact femtosecond Cr:LiSAF laser. This light source generates 5.6 mW of blue average output power at 424 nm with 27 mW of incident fundamental in a single-pass extracavity arrangement at room temperature. The overall system efficiency of electrical power to blue light is 0.5%, and the internal second-harmonic generation conversion efficiency is as high as 37%. The slope efficiency of 5.5% pJ(-1) at low pulse energies is, to our knowledge, the highest slope efficiency yet reported for frequency conversion into the blue spectral region.

Journal Article↗

Simultaneous micromanipulation in multiple planes using a self-reconstructing light beam.

Optical tweezers are commonly used for manipulating microscopic particles, with applications in cell manipulation, colloid research, manipulation of micromachines and studies of the properties of light beams. Such tweezers work by the transfer of momentum from a tightly focused laser to the particle, which refracts and scatters the light and distorts the profile of the beam. The forces produced by this process cause the particle to be trapped near the beam focus. Conventional tweezers use gaussian light beams, which cannot trap particles in multiple locations more than a few micrometres apart in the axial direction, because of beam distortion by the particle and subsequent strong divergence from the focal plane. Bessel beams, however, do not diverge and, furthermore, if part of the beam is obstructed or distorted the beam reconstructs itself after a characteristic propagation distance. Here we show how this reconstructive property may be utilized within optical tweezers to trap particles in multiple, spatially separated sample cells with a single beam. Owing to the diffractionless nature of the Bessel beam, secondary trapped particles can reside in a second sample cell far removed ( approximately 3 mm) from the first cell. Such tweezers could be used for the simultaneous study of identically prepared ensembles of colloids and biological matter, and potentially offer enhanced control of 'lab-on-a-chip' and optically driven microstructures.

Journal Article↗

Creation and manipulation of three-dimensional optically trapped structures.

An interferometric pattern between two annular laser beams is used to construct three-dimensional (3D) trapped structures within an optical tweezers setup. In addition to being fully translatable in three dimensions, the trapped structure can be rotated controllably and continuously by introducing a frequency difference between the two laser beams. These interference patterns could play an important role in the creation of extended 3D crystalline structures.

Journal Article↗

Mueller matrix error correction for a fringe-free interferometry system.

We present an automated surface profiling system based on a shearing interferometer, in which precise measurement of the polarization states eliminates fringe ambiguity. A full error correction based on Mueller matrices allows comparatively inaccurate but rapidly switchable liquid-crystal wave plates to be used, enabling unambiguous profile information to be obtained in real time.

Journal Article↗

Controlled rotation of optically trapped microscopic particles.

We demonstrate controlled rotation of optically trapped objects in a spiral interference pattern. This pattern is generated by interfering an annular shaped laser beam with a reference beam. Objects are trapped in the spiral arms of the pattern. Changing the optical path length causes this pattern, and thus the trapped objects, to rotate. Structures of silica microspheres, microscopic glass rods, and chromosomes are set into rotation at rates in excess of 5 hertz. This technique does not depend on intrinsic properties of the trapped particle and thus offers important applications in optical and biological micromachines.

Animals↗

The application of a compact multispectral imaging system with integrated excitation source to in vivo monitoring of fluorescence during topical photodynamic therapy of superficial skin cancers.

A novel, compact and low-cost multispectral fluorescence imaging system with an integrated excitation light source is described. Data are presented demonstrating the application of this method to in vivo monitoring of fluorescence before, during and after topical 5-aminolevulinic acid photodynamic therapy of superficial skin cancers. The excitation source comprised a fluorescent tube with the phosphor selected to emit broadband violet light centered at 394 nm. The camera system simultaneously captured spectrally specific images of the fluorescence of the photosensitizer, protoporphyrin IX, the illumination profile and the skin autofluorescence. Real-time processing enabled images to be manipulated to create a composite image of high contrast. The application and validation of this method will allow further detailed studies of the characteristics and time-course of protoporphyrin IX fluorescence, during topical photodynamic therapy in human skin in vivo.

Aminolevulinic Acid↗