Search PubMed⌕ Search

Biomedical subjects

W Shoemaker

Publications and source records attributed to W Shoemaker.

23 records · Page 2Linked to original sources

Opioid-dependent behaviors in infant rats: effects of prenatal exposure to ethanol.

Pregnant rats were given diets containing either 5% ethanol, an isocaloric (pair-fed) diet, or casein pellets. Offspring were tested at postnatal day 10 for isolation-induced ultrasonic vocalizations and subsequent stress-induced analgesia. Rats prenatally exposed to ethanol vocalized significantly less in the five minutes during isolation. The opiate, morphine, caused a greater suppression of vocalizations in alcohol-exposed pups compared to controls, while the increased calling normally seen with the opiate antagonist, naltrexone, was attenuated. In a test in which the pup withdraws a paw from a hot plate (48 degrees C), prenatal alcohol offspring demonstrated baseline latencies (no isolation) similar to controls but had greatly attenuated responses in their isolation-induced analgesia. Since both vocalization and analgesia responses have been determined to be modulated by the endogenous opioid system, the aberrant responses of the prenatal-ethanol-exposed offspring can be interpreted as failures to respond by opioid release/secretion to appropriate stimuli.

Aging↗

The eye as a peripheral sensor.

The eye is no longer an organ onto itself, but is now being used as a sensor for the rest of the body. The development, clinical uses, and future applications of conjunctival capillary monitoring are presented.

Adult↗

Noninvasive evaluation of peripheral vascular disease using transcutaneous oxygen tension.

Transcutaneous oxygen tension (PtcO2) was used for noninvasive determination of blood supply in 25 patients evaluated for peripheral arterial disease. PtcO2 values were compared with segmental Doppler pressure, pulse volume recording, pulse reappearance time, and angiography in patients being evaluated for wound healing problems, amputations, and peripheral bypass procedures. PtcO2 was measured using a heated (45 degrees C) Clark polarographic electrode to quantitate the oxygen which diffuses from the dermal capillaries to the skin surface. Control PtcO2 values recorded over the chest or shoulder taken while patients were breathing room air were 78 +/- 8 mm Hg. PtcO2 values greater than 50 mm Hg predicted success for levels of amputation and for wound healing without reconstructive procedures; values of 40 mm Hg or less were associated with continued wound problems and complication after amputation. Increased PtcO2 values after vascular reconstruction of the legs predicted improved clinical status on follow-up examinations up to 6 months. PtcO2 predicted the extent of vascular disease as well as the other noninvasive tests and angiography. We conclude that (1) PtcO2 tension is a simple, accurate, noninvasive method to determine the appropriate level of amputation, wound healing potential, and effectiveness of bypass procedures, and (2) PtcO2 values correlate well with angiography and noninvasive evaluations.

Aged↗

[Prognosis of severe trauma outcome using noninvasive monitoring].

The purpose of the case study was, firstly, to evaluate (starting from the time the patients are admitted to the intensive care unit--ICU) a type of cardiac, pulmonary and peripheral microcirculation in patients with severe traumas by using a multi-component and invasion-free monitoring; the second purpose was to measure quantitatively the changes in the cardiac, pulmonary and peripheral hemodynamics leading to recovery or death; and finally, it was to investigate the effectiveness of applying the discriminative analysis for the sake of assessing the biological value of the controllable changes and of forecast outcome. The invasion-free monitoring system comprising the below tools was in use: an improved bio-impedance method (evaluation of the cardiac output), pulsometry (examination of the pulmonary function), transcutaneous oxygen pressure (tissue perfusion function) and arterial blood pressure (ABP--general circulation status). The results of continuously controllable invasion-free measurements were used for a prospective evaluation at the emergency unit of the county hospital, which was supervised by the university. The accumulated integral values of the deficit or excess of each controllable parameter were calculated by using the differences between the normal values and the values obtained for each patient and for the groups of survivors and dead. A probable outcome and a degree of the deficit of the pulmonary and cardiac functions as well as of the tissue-perfusion function were analyzed by using the discriminant function. The values of pure aggregate deficits (-) or excesses (+) were for the survivors and dead, respectively, as follows: cardiac index--(+)93 +/- 49.8 l/m2 versus -232 +/- 138 l/m2 (p < 0.07); mean ABD(-)-12 +/- 12.4 mm Hg versus -57 +/- 23.5 mm Hg (p < 0.066); arterial saturation(-)-1 +/- 0.09% h versus -9 +/- 2.6% h (p < 0.001): and tissue perfusion--(+)311 +/- 87 tor/h versus 793 +/- 175 tor/h (p < 0.0001). The pure aggregate value of reduced circulation, tissue perfusion and of hypoxemia degree was found to be higher in the dead versus the survivors. The invasion-free monitoring systems secure a constant real-time control over the data, which makes the circulatory malfunction revealed as soon as possible in emergency settings. The mentioned systems can be used to describe, for each patients, a temporal hemodynamic model and to evaluate quantitatively a functional-deficit severity; they also provide for composing a clear-cut and successive treatment scheme from the emergency stage to the intensive care unit.

Adult↗