Search PubMed⌕ Search

Biomedical subjects

W Sepulveda

Publications and source records attributed to W Sepulveda.

At least 109 records · Page 6Linked to original sources

Fetal yawning.

Incidental fetal yawning movements can rarely be observed during real-time ultrasonographic examination. In this report we document repetitive fetal yawning movements in a 27-week fetus over a 7-min period. Each episode lasted for 4-6 s, and the intervals between them varied from 21 to 195 s. This case demonstrated that fetal yawning, a complex involuntary behavioral reflex, is present in its full extent during the second half of pregnancy.

Adult↗

True knot of the umbilical cord: a difficult prenatal ultrasonographic diagnosis.

We examined retrospectively the use of ultrasonography in 18 cases in which a true knot of the umbilical cord was found at delivery. All women had a normal second-trimester scan in which no cord abnormality was detected. Thirteen (72%) also had third-trimester color Doppler ultrasonography, at which time the cord anomaly was again missed. In one of these cases the diagnosis could have been made with color flow imaging, but the abnormal pattern was mistaken instead for multiple loops of cord. On the other hand, the diagnosis of true knot was considered prenatally in two cases, but not confirmed at delivery, when only a prominent false knot was found in one and a normal cord in the other. We conclude that true knots of the umbilical cord do not have a characteristic appearance in utero and therefore are easily missed at routine prenatal ultrasonography.

Adult↗

Prenatal diagnosis of cerebral arteriovenous malformation using color Doppler ultrasonography: case report and review of the literature.

Aneurysms of the vein of Galen are rare, representing less than 1% of all intracranial arteriovenous malformations. In the fetus, however, almost all cerebral arterial malformations involve the vein of Galen, usually presenting in the neonatal period with severe cardiac failure leading to neonatal death. In this report we present a case of arteriovenous malformation involving the vein of Galen detected prenatally at 35 weeks with the use of color Doppler ultrasonography. The literature is reviewed in an attempt to delineate the role of prenatal ultrasonography in the diagnosis and its impact on perinatal outcome.

Adult↗

Prenatal diagnosis of ectrodactyly: the 'lobster claw' anomaly.

Ectrodactyly is a rare condition characterized by absence of digits, ranging from single absence of a finger to the split hand/foot deformity. This anomaly has been reported as sporadic and in association with a number of genetic and non-genetic syndromes, such as the autosomal dominant ectrodactyly and the ectrodactyly-ectodermal dysplasia-cleft palate (EEC) syndromes. In this report we present two cases of ectrodactyly prenatally diagnosed by ultrasonography during the second trimester of pregnancy. Routine examination of fetal hands and feet during second-trimester ultrasonography should make the detection of hand and foot malformations more frequent.

Abnormalities, Multiple↗

Fetal telemedicine: interactive transfer of realtime ultrasound and video via ISDN for remote consultation.

Current referral practice for ultrasonically detected fetal abnormalities contributes to parental anxiety, inconvenience to patients, diagnostic inaccuracy, and general service inefficiency. To determine whether telemedicine would reduce these disadvantages, we established a 30-channel ISDN link between a district general hospital on an island and a subspecialty referral centre approximately 120 km away on mainland Britain. Live ultrasound images of the fetus were transmitted in realtime from a commercial scanner in the hospital using a total data transfer rate of 2 Mbit/s. After decompression at the receiving end, there was almost no perceptible loss of picture quality or frame rate. This report describes the technical aspects of the link and our preliminary experience with it. In the first two months of its operation, the link worked well and the consultants who used it found themselves confidently making diagnoses and carrying out counselling over it. If confirmed, the success of this technology has implications for future referral practice in fetal medicine.

Artifacts↗

Fetal plasma cortisol and beta-endorphin response to intrauterine needling.

The purpose of this study was to investigate whether the fetus mounts a hormonal stress response to a potentially painful procedure, intrauterine needling. Cortisol and beta-endorphin concentrations in fetal plasma obtained during uncomplicated fetal blood sampling or intrauterine transfusions by needling the fetal intra-abdominal portion of the umbilical vein (intrahepatic vein) were compared to hormone concentrations in fetal plasma obtained by the conventional technique of needling the placental cord insertion, which is not innervated. Cortisol and beta-endorphin concentrations did not increase within 10 minutes of fetal abdominal needling (n = 15). However, more prolonged needling during transfusion at the intrahepatic vein was associated with an increase in fetal plasma cortisol (median increase 48 nmol/L; 95% Cl, 23-86) and beta-endorphin (207 pg/mL; 113-307) concentrations compared to transfusion at the placental cord insertion (p < 0.005 for both hormones). The magnitude of rise in hormone increased linearly with the duration of needling (cortisol, r = 0.80; beta-endorphin, r = 0.88, p < 0.05 for both). These data suggest that the fetus mounts a hormonal stress response to invasive procedures. They raise the possibility that the human fetus feels pain in utero, and may benefit from anaesthesia or analgesia for invasive procedures.

Analgesia↗

The value of color Doppler ultrasound in the prenatal diagnosis of hypoplastic umbilical artery.

The prenatal diagnosis of hypoplastic umbilical artery has recently been reported, based on the visualization of discordant size between both umbilical arteries in association with discordant umbilical artery flow velocity waveforms. In this report we present two cases of hypoplastic umbilical artery and describe the use of color flow imaging and Doppler ultrasound in the prenatal evaluation of this condition. The principal advantages of these techniques include the confirmation of blood flow within the hypoplastic artery, thus ruling out the possibility of an atrophic non-functional artery, and the demonstration of size discrepancy at the level of the intra-abdominal portion of the umbilical arteries, validating the intra-amniotic cord findings. Color Doppler ultrasound is an important tool for diagnosing and evaluating vascular anomalies affecting the umbilical cord.

Journal Article↗

Prenatal diagnosis of umbilical cord pseudocyst.

The association between umbilical cord anomalies and chromosomal abnormalities has received little attention in the literature. In this report, we present two cases of umbilical cord pseudocyst incidentally detected by ultrasound prior to genetic amniocentesis performed for the indication of advanced maternal age. In the first case it was only the initial abnormal finding in a 21-week fetus ultimately found to have a trisomy 18. In the second case, detected at 26 weeks, the karyotype was normal and a healthy normal neonate was delivered at term. The finding of a umbilical cord cystic mass during prenatal sonographic examination should alert the clinician to the increased risk of aneuploidy.

Journal Article↗

Prenatal detection of congenital hypospadias in the Wolf-Hirschhorn (4p-) syndrome.

Hypospadias is one of the most prominent and characteristic midline defects in male infants with the Wolf-Hirschhorn (4p-) syndrome. In this report we present a case in which hypospadias was identified prenatally at 29 weeks' gestation in association with intrauterine growth retardation. Cytogenetic evaluation after birth confirmed a 46,XY,del(4)(p14) karyotype. The prenatal identification of hypospadias in fetuses with intrauterine growth retardation and normal amniotic fluid should suggest a diagnosis of Wolf-Hirschhorn syndrome.

Abnormalities, Multiple↗

Discordant iliac and femoral artery flow velocity waveforms in fetuses with single umbilical artery.

OBJECTIVE: The aim of this study was to investigate pelvic and femoral arterial flow velocity waveforms in fetuses with a single umbilical artery. STUDY DESIGN: Seven fetuses with single umbilical artery and no other ultrasonographically detected anomalies were studied with color Doppler ultrasonography at a median gestational age of 24 weeks (range 18 to 34 weeks). Flow velocity waveforms from the relevant vessels were obtained as follows: (1) umbilical artery from a free loop of cord, (2) common iliac artery from both sides just below the aortic bifurcation, (3) internal iliac artery and intraabdominal portion of the umbilical artery from the vessel visualized alongside the fetal bladder, and (4) femoral artery on both sides from the upper third of the fetal thigh. The pulsatility index was measured, and comparisons were made with the paired t test. A p value < 0.05 was considered significant. RESULTS: The pulsatility index in the umbilical artery was normal in all cases. There were highly significant differences between the common iliac arteries in each side (difference in pulsatility index 2.7, 95% confidence interval 2.0 to 3.5, p < 0.001). Significant differences between both femoral arteries were also noted (difference in pulsatility index 1.0, 95% confidence interval 0.3 to 1.7, p < 0.001). In both vessels the pulsatility index was always higher in the side that did not participate in the placental circuit. CONCLUSION: This study demonstrates that fetuses with single umbilical artery have asymmetric arterial blood flow patterns in the pelvic and lower extremities.

Blood Flow Velocity↗

The influence of operator transducer pressure on ultrasonographic measurements of amniotic fluid volume.

OBJECTIVE: Our purpose was to study the effect of operator transducer pressure on amniotic fluid index and single deepest pool measurements and their intraobserver and interobserver variability. STUDY DESIGN: Forty subjects in the third trimester with intact membranes were studied by two observers at three predetermined operator pressures. Pressure was measured by interfacing a flexible water-filled reservoir connected to a manometer between the maternal abdomen and the ultrasonography transducer. The amniotic fluid index and single deepest pool were measured on screen by another operator, and data were analyzed by calculating components of variance. RESULTS: Compared with medium pressure, low pressure resulted in a 13% increase in amniotic fluid index (p < 0.001), and high pressure resulted in a 21% fall in amniotic fluid index (p < 0.001). The single deepest pool was less sensitive to pressure, with a 11% increase at low pressure (p < 0.001) and a 16% fall at high pressure (p < 0.001). Intraobserver error was 17% for amniotic fluid index and 18% for single deepest pool when operator pressure was controlled at medium pressure; this increased to 28% and 24%, respectively, when pressure was not controlled (p < 0.01). Interobserver error was consistently very low. CONCLUSION: Both techniques are highly sensitive to the pressure applied to the maternal abdomen during scanning. The reproducibility of amniotic fluid index and single deepest pool is comparable. The use of the same observer for serial measurements of amniotic fluid index would appear to be less important than careful attention to transducer pressure.

Amniotic Fluid↗

Direct volume measurement at midtrimester amnioinfusion in relation to ultrasonographic indexes of amniotic fluid volume.

OBJECTIVE: Our purpose was to investigate the relationship between amniotic fluid volume and semiquantitative ultrasonographic assessment of amniotic fluid in the midtrimester. STUDY DESIGN: Sixteen pregnancies between 16 and 28 weeks with minimal amniotic fluid (severe oligohydramnios or anhydramnios) and intact membranes were studied at the time of clinically indicated amnioinfusion. The amniotic fluid index and deepest pool measurement were determined before and immediately after the procedure. Correlations were sought by means of standard regression techniques with amniotic fluid volume (i.e., volume infused) on the basis of the assumption that amniotic fluid volume before amnioinfusion was effectively nil. RESULTS: There was a significant linear relationship between amniotic fluid index and volume infused (y = 7.336 + 0.015x; R2 = 0.30, p < 0.05). However, no correlation with the deepest pool measurement technique was found (R2 = 0.11, p > 0.05). CONCLUSION: Amniotic fluid index is preferable to deepest pool measurement in assessing amniotic fluid volume in the second trimester of pregnancy. The low variance (30%) suggests that better predictors of amniotic fluid volume are still required.

Amniotic Fluid↗