Search PubMed⌕ Search

Biomedical subjects

W R Wolf

Publications and source records attributed to W R Wolf.

24 records · Page 2Linked to original sources

Determination of niacin in infant formula and wheat flour by anion-exchange liquid chromatography with solid-phase extraction cleanup.

Niacin content must be included on food labels of infant formula products and bakery products containing enriched flour. Liquid chromatographic (LC) determination of niacin in complex food matrixes is complicated by the presence of endogenous compounds that absorb at the commonly used wave-length of 260 nm. Also, the presence of particulate matter in the standard sulfuric acid extraction procedure results in reduced life of LC columns and precolumns. A simple, rapid, solid-phase extraction (SPE) procedure for separation and cleanup of niacin from a complex food matrix digest has been developed. By using a vacuum manifold with the SPE column system, multiple samples can be processed quickly and efficiently for LC analysis, compared with gravimetric column cleanup. Sulfuric acid sample digest is passed over an aromatic sulfonic acid cation-exchange (ArSCX-SPE) or a sulfonated Florisil SPE column. Niacin is eluted with 0.25M sodium acetate-acetic acid, pH 5.6 buffer in vacuo. LC chromatograms of the resulting eluate are free of interference from other components absorbing at 260 nm at the retention time of niacin. Validation of the method was obtained from agreement of analytical results on available reference materials. For both SPE methods, values for niacin in SRM 1846 Infant Formula (milk-based powder) were within uncertainty ranges of the certified value. Use of several calibration procedures (the LC computer program, a peak area response graphic standard curve, or the method of standard additions) with both SPE procedures resulted in niacin values for 3 RM-Wheat Flours (not certified for niacin) in agreement (90-105%) with their respective values reported in the literature. Several commercial wheat flours showed a broad 260 nm interference, resulting in high niacin values. Niacin recoveries from spiked soy-based liquid infant formulas ranged from 95-107% with the ArSCX-SPE column. Calibration curves of niacin were linear up to 400 micrograms/mL, with a detection limit of 0.2 microgram/mL.

Chromatography, Ion Exchange↗

Determination of niacin in infant formula by solid-phase extraction and anion-exchange liquid chromatography.

A peer-verified, solid-phase extraction (SPE)/anion exchange liquid chromatographic method is presented for the determination of niacin in milk-based and soy-based infant formula. Analysis is in 3 steps: test sample digestion, extraction/cleanup, and liquid chromatography (LC). Digestion uses a standard AOAC digestion procedure that involves autoclaving at 121 degrees C for 45 min in (1 + 1) H2SO4 to free endogenous niacin from protein and to convert added niacinamide to niacin. The digest solution is adjusted to pH 6.5 with 7.5M NaOH. Acidification to pH <1.0 with (1 + 1) H2SO4 precipitates the protein. The clarified solution is then filtered, and the filtrate is brought to volume. SPE of niacin is accomplished by passing an aliquot of the digest solution through an aromatic sulfonic acid-SPE (ArSCX-SPE) column. After the column is washed with methanol and water to remove extraneous material, the niacin is eluted with 0.25M sodium acetate/acetic acid buffer at pH 5.6. An anion-exchange polystyrene-divinylbenzene column with 0.1 M sodium acetate/acetic acid buffer at pH 4.0 is used for LC. Niacin is determined by UV detection at 260 nm. A standard curve is prepared by passing known amounts of niacin through the ArSCX-SPE columns used for niacin extraction. The following values for x and relative standard deviation (RSD) were obtained for National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1846 Infant Formula with a certified value for niacin of 63.3 +/- 7.6 microg/g: Submitting laboratory.-- x = 59.7 +/- 4.0 microg/g; RSD = >6.7%; confidence interval (CI) = +/- 1.4 microg/g; n = 27. Peer laboratory.--x = 56.6 +/- 6.6 microg/g; RSD = >11.7%; CI =+/- 4.1 microg/g; n = 8.

Animals↗

Potential application of LASER/microbe bioassay technology for determining water-soluble vitamins in foods.

A microbiological technique was developed for quantitating niacin by determining microbial growth rates in response to the amount of vitamin available. Unlike the current official AOAC method, the new procedure for niacin measured the growth rates during the early exponential growth phase rather than during the stationary phase. Lactobacillus plantarum was used to determine niacin to a lower limit of 100 pg/mL. The assay time was approximately 6 h, compared with 16-24 h for the current AOAC method. The extent of microbial growth was determined by differential light scattering of a LASER beam. Multiple photodetectors were integrated with a computer system to collect and analyze the data. The use of differential light scattering to determine 8 water-soluble vitamins under stationary phase conditions demonstrated the potential application of the new technology for microorganisms and foods.

Biological Assay↗

Certification of nutrients in Standard Reference Material 1846: infant formula.

In 1996, the National Institute of Standards and Technology (NIST) released Standard Reference Material 1846 (Infant Formula), which can be used as a control material for assigning values to in-house control materials and for validating analytical methods for measurement of proximates, vitamins, and minerals in infant formula and similar matrixes. The SRM was manufactured by preparing a spray-dried formula base containing fat, protein, carbohydrates, and minerals and then combining that formula base with a dry-blend vitamin premix that supplied the vitamins. The Certificate of Analysis for SRM 1846 provides assigned values for concentrations of proximates (fat, protein, etc.), vitamins, and minerals for which product labeling is required by the Infant Formula Act of 1980 and by the Nutrition Labeling and Education Act of 1990. These assigned values were based on agreement of measurements by NIST and/or collaborating laboratories. Certified values are provided for vitamins A (trans), E, C, B2, and B6 and niacin. Noncertified values are provided for solids, ash, fat, nitrogen, protein, carbohydrate, calories, vitamin D, delta-tocopherol, gamma-tocopherol, vitamin B1, vitamin B12, folic acid, pantothenic acid, biotin, choline, inositol, calcium, phosphorus, magnesium, iron, zinc, copper, sodium, potassium, and chloride. Information values are provided for iodine, manganese, selenium, and vitamin K.

Food Analysis↗