Search PubMed⌕ Search

Biomedical subjects

W P Santamore

Publications and source records attributed to W P Santamore.

At least 19 recordsLinked to original sources

Vascular delay and intermittent stimulation: keys to successful latissimus dorsi muscle stimulation.

BACKGROUND: The goal of this study was to obtain physiologically significant increases in peak left ventricular (LV) systolic pressure and stroke volume with latissimus dorsi muscle (LDM) stimulation in cardiomyoplasty (CMP). We hypothesized that preserving LDM integrity by vascular delay and intermittent stimulation would significantly increase LDM cardiac assistance. METHODS: In 4 control dogs and 12 dogs that had undergone a vascular delay (VD) procedure, LV dysfunction was induced by intracoronary microsphere injections. Cardiomyoplasty surgery was performed 14 days later, followed by progressive LDM conditioning. In the control dogs and in 6 of the VD dogs, the LDM was stimulated 24 hours per day (VD plus constant stimulation [CS]). In the other 6 VD dogs, LDMs were stimulated on a daily schedule of 10 hours on and 14 hours off (VD plus interrupted stimulation [IS]). Latissimus dorsi muscle stimulated beats were compared with nonstimulated beats 9 weeks later. RESULTS: In the control dogs, LDM stimulation had minimal effects. In VD + CS and VD + IS, LDM stimulation increased peak LV pressure, stroke volume, stroke work, and stroke power (p < 0.05). However, these changes were greater in the VD + IS group, in which LDM stimulation increased peak aortic pressure by 17.6 +/- 1.7 mm Hg, peak LV pressure by 19.7 +/- 1.1 mm Hg, peak positive LV dp/dt by 398 +/- 144 mm Hg per second, stroke volume by 5.1 +/- 0.7 mL, stroke work by 10.9 +/- 0.9 gm.m, and stroke power by 122.7 +/- 11.6 gm.m per second (p < 0.05 compared with VD + CS). Quantitative morphometric analysis showed minimal LDM degeneration in the VD + IS group (7.5% +/- 1.1%), and VD + CS group (10.5% +/- 4.5%) compared with the control group (29.5% +/- 4.5%, p < 0.05). CONCLUSIONS: VD and IS considerably increased the LV assistance with LDM stimulation. Further studies of this combined approach to CMP should be planned.

Animals↗

Chemoreflexes: an experimental study.

HYPOTHESIS: Transmyocardial laser revascularization (TMLR) will not denervate the heart, because it does not destroy all of the afferents. This study was designed to determine if stimulation of cardiac sympathetic and vagal afferents from an area of the left ventricle treated with TMLR could evoke reflex effects, and thus whether TMLR would denervate the heart. METHODS: The effect of TMLR on reflexes evoked by chemically stimulating cardiac afferents was examined in 9 dogs. Bradykinin and capsaicin were applied topically or injected into the left anterior descending coronary artery before and after TMLR and after bilateral vagotomy and sympathectomy. Aortic (AoP) and left ventricular pressures (LVP) and electrocardiography were monitored. The first derivatives of LVP (dP/dt) were calculated. RESULTS: Topical bradykinin elicited variable hemodynamic responses. Topical capsaicin evoked pressor responses, increasing mean (+/- SEM) AoP (105+/-9 to 115+/-9 mm Hg; P<.001) and positive dP/dt (+dP/dt) (1032+/-81 to 1159+/-10 mm Hg/s; P<.01) before TMLR. Intracoronary capsaicin evoked a depressor response before TMLR. Pressor responses remained intact after TMLR with increases in mean AoP and +dP/dt (115+/-6 to 128+/-5 mm Hg and 1039+/-98 to 1136+/-100 mm Hg/s, respectively; P<.01). Depressor responses also remained intact after TMLR (91+/-10 vs 101+/-11 mm Hg [P<.02], and 865+/-104 vs 931+/-104 mm Hg/s [P<.05], respectively). Hemodynamic responses were diminished after bilateral vagotomy and abolished after bilateral sympathectomy. CONCLUSION: Since activation of cardiac afferent nerves and reflex responses remained intact after TMLR, but changed after vagotomy or sympathectomy, TMLR does not denervate the heart sufficiently to be the cause of improved angina after TMLR.

Afferent Pathways↗

Vascular delay of the latissimus dorsi provides an early hemodynamic benefit in dynamic cardiomyoplasty.

OBJECTIVES: Dynamic cardiomyoplasty (CMP) as a surgical treatment for chronic heart failure improves functional class status for most patients. However, significant hemodynamic improvement with latissimus dorsi muscle (LDM) stimulation has not been consistent. The current protocols do not allow early LDM stimulation after CMP surgery. We hypothesized that vascular delay of LDM would increase myocardial assistance after CMP and allow early (48-h) LDM stimulation after CMP. METHODS: Mongrel dogs (n = 24) were divided in four groups: 1) controls (n = 6), single-stage CMP; 2) Group ES (n = 6), single-stage CMP with early LDM stimulation beginning 48 h, postoperatively; 3) Group VD (n = 6), vascular delay of the LDM followed by CMP without early LDM stimulation, and 4) Group VDES (n = 6), vascular delay of LDM (14-18 days), followed by CMP with early stimulation (48 h postoperatively). Two weeks after CMP, global cardiac dysfunction was induced by injecting microspheres into the left coronary artery. LDM-assisted (S) beats were compared with nonstimulated beats (NS) by measuring aortic pressure (AoP), LV pressure, aortic flow, and by calculating first derivative of LV contraction (+/-dP/dt), stroke volume (SV), and stroke work (SW). RESULTS: In ES, LDM stimulation had no effect on the hemodynamic parameters. In the other groups, LDM stimulation significantly (p < 0.05) increased AoP, LVP, dP/dt, SV, and SW. However, these increases were much larger in VD and VDES. In VD, LDM stimulation increased peak AoP by 21.5+/-3.8 mm Hg, LVP by 22.1+/-4.1 mm Hg, dP/dt by 512+/-163 mm Hg/sec, SV by 10.4+/-2.3 mL, and SW by 22.1+/-5.4 g/m(-1). Similarly, in VDES, LDM stimulation increased peak AoP by 24.1+/-4.7 mm Hg, LVP by 26.2+/-4.3 mm Hg, dP/dt by 619+/-47 mm Hg/sec, SV by 6.5+/-0.7 mL, and SW by 16.7+/-4.1 g/m(-1). CONCLUSIONS: In dogs with global LV dysfunction, CMP after vascular delay resulted in a significant improvement in hemodynamic function measured 2 weeks after surgery. This improvement was not provided by single-stage CMP with or without early stimulation. Vascular delay of the LDM before surgery may play an important role for early benefit after CMP, shorten the overall muscle training period, as well as increase hemodynamic response to LDM stimulation.

Animals↗

Evaluation of stimulation parameters on aortomyoplasty, using Latissimus Dorsi muscle in a goat model: an acute study.

OBJECTIVE: Dynamic aortomyoplasty using Latissimus Dorsi muscle (LDM) has been shown to improve myocardial function. However, systematic examination of the effects of stimulation parameters on aortic wrap function has not been done. Thus, the present study measures the direct effect of stimulation voltage, pulse train duration, frequency of the pulses, and the duration of the stimulation delay from R wave on the aortic wrap function. METHODS: In eight female goats, the left LDM was wrapped around the descending aorta. The muscle was then subjected to electrical stimulation, altering frequency of stimulation pulses (16.6, 20, 25, 33 and 50 Hz), amplitude (2, 4, 6, 8 and 10 V), and number of pulses (2, 4, 6, 8 and 10 pulses) in a train stimulation. Left ventricular, aortic pressure, and pressure generated by LDM on aorta (wrap pressure) was measured. The changes in hemodynamic parameters mentioned above were calculated and compared for different stimulation parameters during unassisted and assisted cardiac cycles. RESULTS: Aortomyoplasty counterpulsation using LDM provided significant improvement in wrap pressure (78 mmHg +/- 2), aortic diastolic pressure, and changes in aortic diastolic pressure from 2 to 4 V (P < 0.05). Further increase in amplitude did not make any significant improvements of the above mentioned parameters. Significant augmentation of wrap pressure (82 mmHg +/- 2), aortic diastolic pressure (79 mmHg +/- 3) and changes in aortic diastolic pressure (12 mmHg +/- 1) occurred at 6 pulses (P < 0.05). Other changes in number of pulses did not show any significant improvements. Significant improvement of wrap pressure (80 mmHg +/- 2), aortic diastolic pressure (73 mmHg +/- 3) and changes in aortic diastolic pressure (12 mmHg +/- 1) was observed with a frequency of 33 Hz. To examine a wide range of delays from the onset of the QRS complex to LDM stimulation, stimulation was delivered randomly. The exact delay was determined from the ECG signal and superimposed LDM stimulation pulses. CONCLUSIONS: In this study we present a new measurement, wrap pressure. We also present that in aortomyoplasty using LDM, the most significant improvement in wrap pressure, aortic diastolic pressure and changes in aortic diastolic pressure occurs when the stimulation consists of an amplitude of 4 V, a frequency of 33 Hz and a train stimulation of 6 pulses.

Animals↗

Estimation of oxygen delivery in newborns with a univentricular circulation.

BACKGROUND: The management of neonates with complex congenital anomalies depends on careful interpretation of arterial blood gas values. Improved interpretation of these oxygen parameters may allow clinicians to avoid unexpected cardiovascular events. This study examined whether systemic oxygen delivery (DO2) can be maximized by the use of indices derived from oxygen saturation measurements in neonates with hypoplastic left heart syndrome. METHODS AND RESULTS: For the single-ventricle heart with both circulations in parallel, we used a previously developed computer simulation to obtain DO2 as a function of systemic arterial (SaO2) and venous (SvO2) oxygen saturation, arteriovenous oxygen difference (Sa-vO2), or pulmonary-to-systemic flow ratio (Qp/Qs). We also examined the oxygen excess factor, SaO2/Sa-vO2 (Omega). We found that (1) slight increases in SaO2 may be associated with large decreases in DO2. (2) Low values for SvO2 indicate low values for DO2. (3) Curves for Sa-vO2 and Qp/Qs are redundant in the data provided. (Qp/Qs, however, provides these data in more physiologically relevant terms.) (4) High values for Qp/Qs (>4) are associated with low DO2. (5) Estimating Qp/Qs from oxygen saturation measurements may result in errors when pulmonary venous oxygen saturation is not available. (6) Maximizing DO2 is extremely difficult using SaO2, SvO2, and Qp/Qs. (7) A linear relationship exists between Omega and DO2, and this linear relationship is not altered by changes in cardiac output. CONCLUSIONS: Patients with low SvO2 values require attention. Ideally, after reducing Qp/Qs to <1.5, Omega might be a better index to guide further therapy and maximize DO2. Interventions that increased Omega would be considered beneficial, whereas interventions that decreased Omega would be considered detrimental.

Cardiac Output↗

Preconditioning of the latissimus dorsi muscle in cardiomyoplasty: vascular delay or chronic electrical stimulation.

OBJECTIVES: In standard single stage cardiomyoplasty (CMP), the latissimus dorsi muscle (LDM) is not preconditioned prior to surgery. We hypothesized that latissimus dorsi preconditioning by vascular delay or by chronic electrical stimulation would result in an improved LV hemodynamic function early (14 days) after CMP. METHODS: Mongrel dogs had preconditioning of the latissimus dorsi by a vascular delay procedure followed by CMP 14-18 days later (group I VD). Dogs in group II underwent 4 weeks of chronic stimulation (CS) of the latissimus dorsi (2 V/30 Hz, six bursts/min) followed by CMP. The latissimus dorsi muscle was fully stimulated from 48 h after cardiomyoplasty in both groups (2 V/30 Hz, three bursts/min). Two weeks after myoplasty, injecting 2.0-3.0 x 10(5) 90 microm latex microspheres in the left main coronary artery induced global cardiac dysfunction. Hemodynamic function was then evaluated for latissimus dorsi muscle assisted (S) beats and non-stimulated beats (NS) in each group by measuring peak systolic aortic pressure (AOP), left ventricular pressure (LVP) and end diastolic pressure (LVEDP), and by calculating maximum and minimum dP/dt. RESULTS: Dogs with vascular delay of the latissimus dorsi showed a marked increase for all hemodynamic indices (AOP: 23.9+/-2.5%, LVP: 23.5+/-2.2%, max dP/dt: 49.4+/-3.3%) for LDM assisted (S) beats compared to non-stimulated beats (P < 0.001). Animals with chronic electrical training did not demonstrate a significant increase in any hemodynamic parameter with LDM stimulation. CONCLUSION: Preconditioning the LDM may play an important role in providing early cardiac assistance in CMP. Preconditioning the LDM with vascular delay resulted in improving performance of the LDM with consistent increases in LV hemodynamics. This was not observed after preconditioning with chronic electrical stimulation. Vascular delay of the latissimus dorsi can significantly improve muscle performance in CMP and could provide hemodynamic assistance early after surgery.

Animals↗

Effects of positive pressure ventilation and inspired oxygen on pulmonary vascular resistance and tissue oxygen delivery in neonatal pigs.

Management of pulmonary vascular resistance in neonates with congenital heart disease is important for stabilization before and after surgical interventions. Thus, we determined which combination of positive end-expiratory pressure ventilation and fraction of oxygen in the inspired air increases pulmonary vascular resistance without compromising delivery of oxygen to the tissue. Eight piglets were anesthetized, intubated and ventilated. Pulmonary flow and pulmonary arterial and left atrial pressures were monitored continuously. At all levels of inspired oxygen (1.00, 0.21 and 0.15), ventilation at a pressure of 15 cm of water increased pulmonary vascular resistance. At all levels of positive pressure ventilation, a fraction of 0.15 of inspired oxygen increased pulmonary vascular resistance. The combination of a ventilatory pressure of 15 cm of water and inspired oxygen of 1.00, or ventilatory pressure at 5 cm of water and oxygen delivery of 0.15, produced similar changes in pulmonary vascular resistance (19.1 +/- 2.8 vs. 20.0 +/- 3.8 mmHg/(L/min)) and cardiac output (0.78 +/- 0.07 vs. 0.93 +/- 0.10 L/min) but, the higher level of positive pressure plus 1.00 inspired oxygen gave a significantly higher arterial oxygen saturation (0.99 +/- 0.03 vs. 0.72 +/- 0.19%) and delivery of oxygen to the tissues (13.7 +/- 2.9 vs. 7.4 +/- 1.5 ml O2/min, p < 0.05). Thus, both high positive pressure ventilation and hypoxia increase pulmonary vascular resistance. Only high pressure ventilation plus high concentrations of inspired oxygen, however, increased pulmonary vascular resistance without compromising delivery of oxygen, suggesting that this combination is a superior means of increasing pulmonary vascular resistance.

Animals↗

A versatile microprocessor-based multichannel stimulator for skeletal muscle cardiac assist.

A versatile, microprocessor-based stimulator for skeletal muscle cardiac assist (SMCA) has been designed, constructed, and used in several studies. The stimulator uses multiple bipolar electrodes to deliver arbitrarily specified electrical stimulus sequences to three nerve branches of the latissimus dorsi muscle. The electrodes are electrically isolated to effect regional stimulation of the muscle. The width, amplitude, and interpulse interval of each pulse in the stimulus sequence are independently variable, and the three channels are independently programmable, allowing a wide variety of stimulus patterns. Battery powered units have been used in studies for up to one year. In this paper, the stimulator and sample applications in SMCA are described.

Analog-Digital Conversion↗

Theoretical optimization of pulmonary-to-systemic flow ratio after a bidirectional cavopulmonary anastomosis.

A univentricle with parallel pulmonary and systemic circulations is inherently inefficient because mixing of pulmonary and systemic venous return occurs. Thus a cavopulmonary anastomosis is used as a staged palliative procedure to reduce volume overload in patients with cyanotic congenital heart disease. On the basis of oxygen uptake and consumption, an equation was derived that related cardiac output, pulmonary venous oxygen saturation, upper body oxygen consumption, and superior-to-inferior vena caval blood flow ratio (QSVC/QIVC) to oxygen delivery. The primary findings were as follows. 1) As QSVC/QIVC increases, total body oxygen delivery and arterial and superior vena caval oxygen saturations increase. 2) As QSVC/QIVC increases, lower body oxygen delivery and inferior vena caval oxygen saturation initially increase, then peak, and then decrease. 3) As the percentage of lower body oxygen consumption increases, oxygen delivery and saturation decrease. 4) A cavopulmonary anastomosis decreases the required cardiac output for a given oxygen delivery. Thus we concluded that a high systemic arterial oxygen saturation after cavopulmonary anastomosis requires a high percentage of upper body oxygen consumption and a high QSVC/QIVC and that the cavopulmonary anastomosis reduces the volume load on the single ventricle.

Cardiac Output↗

Preventing gastroepiploic artery spasm: papaverine vs calcium channel blockade.

UNLABELLED: The gastroepiploic artery (GEA) is a highly vasoactive artery gaining wider acceptance as a conduit for coronary artery bypass surgery. A variety of agents are used to dilate the GEA prior to grafting; however, little is known about the duration of their effect in the immediate postoperative period. This study evaluated three calcium channel blockers and papaverine in preventing graft spasm. METHODS: Porcine GEA segments (10-12 cm in length) were connected to a computer-controlled perfusion system with a constant in-flow pressure and distal resistance to simulate bypass flow (80-100 ml/min). Norepinephrine (NE; 10(-9) to 10(-5) M) was given in incremental doses at baseline before the vasodilator, immediately after (0 hr), and again at 2 hr after the vasodilator. Changes in flow and ED50 were recorded. Group INT (N = 25) received papaverine (PAP), diltiazem, nifedipine (NFP), or verapamil (VPL) intraluminally, while group EXT (N = 25) received the same dilators externally. RESULTS: All arteries showed dose-dependent vasoconstriction to NE prior to treatment. Immediately after receiving the vasodilator, arteries in both groups (INT and EXT) showed initial protection against NE-induced spasm with the exception of arteries receiving NFD externally. However, at 2 hr, for group INT, only VPL and NFD prevented NE-induced graft spasm (VPL: 40.4 +/- 6.8 ml/min vs 17.9 +/- 3.3 ml/min and NFD: 27.0 +/- 6.5 ml/min vs 13.1 +/- 0.9 ml/min, P < 0.02). In group EXT, after 2 hr, only VPL- and PAP-treated grafts showed resistance to NE-induced vasospasm (VPL: 35.6 +/- 7.3 ml/min vs 15.0 +/- 6.9 ml/min and PAP: 47.4 +/- 15.1 ml/min vs 8.0 +/- 2.0 ml/min, P < 0.001). CONCLUSIONS: Papaverine, a lipophilic vasodilator, when given externally on the perivascular fat of the GEA, prevented graft spasm for up to 2 hr. In contrast, intraluminally applied papaverine did not show graft protection against NE-induced spasm. Nifedipine prevented NE-induced spasm only when given intraluminally. Verapamil proved to be the most potent and versatile vasodilator with effective graft protection of up to 2 hr whether applied externally or internally and was the preferred agent for protecting against GEA spasm.

Animals↗

Monitoring systemic venous oxygen saturations in the hypoplastic left heart syndrome.

Although progress has been made in treating hypoplastic left heart syndrome, improvements in perioperative care may further decrease mortality. We present a case in which continuous monitoring of systemic venous oxygen saturation allowed stabilization and successful management of a critically ill infant. Systemic venous oxygen saturation may provide a more accurate representation of a child's clinical status, allowing more rapid intervention and better outcomes.

Blood Vessel Prosthesis↗

Minimally invasive coronary artery bypass grafting: on the beating heart and via limited access.

Minimally invasive coronary artery bypass grafting (MICABG) may be achieved by arterial grafting on the beating heart, without cardiopulmonary bypass, and by operations via limited access. The Second Utrecht MICABG Workshop held October 4-5, 1996, focused on beating-heart coronary immobilization, limited-access thoracoscopic and direct-vision mobilization of the internal mammary artery, limited-access left anterior descending coronary artery grafting, and, finally, facilitated distal anastomosis techniques. It has yielded 33 reports in this supplement. The combined, cumulative experience of a number of participants exceeded 3,000 beating-heart cases, including more than 1,000 with arterial grafting through limited access. The average number of anastomoses per patient ranged from 1.0 to 2.0. Therapeutic strategies are evolving, and dedicated instrumentation is being developed. Randomized clinical trials with angiographic follow-up are required to establish that the reduction in invasiveness of coronary bypass grafting is not achieved at the expense of suboptimal quality of the arterial graft and the distal anastomosis.

Cardiopulmonary Bypass↗

Intraoperative monitoring of IMA flow: what does it mean?

BACKGROUND: This study examines whether the measurement of internal thoracic artery (ITA) graft flow can determine the adequacy of the ITA-left anterior descending coronary artery (LAD) anastomosis. METHODS: To study a wide range of clinical problems, we used a computer simulation of the cardiovascular system. The model included a time-varying elastance model of the heart, a systemic circulation represented by a multielement nonlinear model of the aorta and its major branches, a nonlinear model of the LAD circulation, and a model of the ITA bypass graft. RESULTS: With a mild LAD stenosis, ITA graft flow was low and flow reversal occurred. As the percent stenosis increased, ITA flow and the percentage of ITA-to-total LAD flow increased. The ITA graft helped to maintain resting LAD blood flow. A partial obstruction (40%) at the ITA-LAD anastomosis reduced ITA graft flow at similar levels of LAD stenosis. However, overlap in flow values comparing a normal with a partially obstructed anastomosis occurred. CONCLUSIONS: Flow patterns in the ITA are highly dependent on the degree of stenosis of the LAD as well as the integrity of the anastomosis. The predictive power of ITA flow measurement increases with severe stenosis or total occlusion of the proximal LAD and with high coronary blood flow demands.

Anastomosis, Surgical↗

What in-vitro method should surgeons use to evaluate the clinical behavior of arterial bypass conduits.

UNLABELLED: Surgeons have traditionally relied on ring preparations to predict how arterial bypass conduits will behave in the postoperative circulation. OBJECTIVE: This study compared pharmacologic [norepinephrine (NE) challenge] and physiologic [arterial preload] responses of gastroepiploic (GEA) and internal thoracic (ITA) arteries in a standard static ring preparation and a dynamic perfusion system. METHODS: Six GEAs (1.0-1.5 mm dia.) and six ITAs (1.5-2.0 mm dia.) 11 cm long were harvested from adult pigs and mounted on a computer controlled perfusion system. Inflow pressure was set at 80 mmHg and outflow resistance was adjusted to simulate high (80-90 ml/min) and low (15-20 ml/min) flow demands. NE response (10(-9)-10(-5) M) was measured under low flow conditions and at high flow conditions when distal arterial pressure (load) was reduced. NE response (10(-9)-10(-5) M) was also evaluated in arterial rings (ITA N = 6, GEA N = 6) with tensions adjusted to simulate the loads occurring at low flow (80 mmHg) and high flow (60 mmHg) situations. RESULTS: In the static ring preparation, NE response [ED50] was similar for both GEA and ITA and was not affected by load. The dynamic preparation demonstrated that the GEAs were significantly more responsive to NE than the ITAs [ED50 high flow ITA 6.1 +/- 0.3**, GEA 7.2 +/- 0.3***; *P < 0.05 versus baseline, **P < 0.05 versus low flow values, ***P < 0.05 versus ITA]. Furthermore, in the dynamic preparation, NE response was profoundly affected by reduced load which occurs under high flow conditions [7.18 +/- 0.3 versus 6.1 +/- 0.3 under high flow and 5.8 +/- 0.1 versus no response under low flow conditions]. CONCLUSION: Static ring preparations do not discern differences between ITA and GEA susceptibility to spasm and fail to detect the effect of load. The dynamic preparation demonstrated significant differences between the GEA and ITA potential to spasm which is consistent with widespread clinical experience. Furthermore a dynamic preparation is highly sensitive to reduced load which occurs under high flow conditions. Although it is more demanding, the dynamic preparation provides superior information to the surgeon in predicting the behavior of arterial bypass grafts.

Animals↗

Variable effects of cardiomyoplasty on left ventricular function.

Cardiomyoplasty (CMP) has been considered as a possible treatment for patients with heart failure. Symptomatic improvements occur almost uniformly among survivors with CMP, but changes in left peak ventricular systolic pressure (PVSP) and stroke volume vary in patients. This study examined whether there is variability present shortly after cardiomyoplasty surgery. Cardiomyoplasty was performed in 11 mongrel dogs with normal ventricular function. Nine to twelve days after CMP, left ventricular (LV) function was evaluated by simultaneously measuring LV volume (conductance catheter) and pressure (Millar catheter). The latissimus dorsi muscle (LDM) was stimulated synchronously with ventricular systole in a ratio of 1:4 to 1:7 to avoid muscle fatigue. Data were analyzed on a beat by beat basis. The PVSP, and maximum dP/dt (+dP/dt) increased, but the absolute value of minimum dP/dt (-dP/dt) decreased in stimulated beats in 7 dogs while 4 dogs did not respond. The net changes in stimulated beats versus nonstimulated beats of PVSP were 6.1 +/- 1.8 mm Hg (4.3%), of stroke work was 4.5 +/- 1.9 gm x m (29.5%), of +dP/dt was 185 +/- 47 mm Hg/s (8%), and of -dP/dt was 168 +/- 43 mm Hg/s (7.8%) (p < 0.05) for all these net changes in the responding group while these variations were not significant in the nonresponding group. From the results of our study, active LDM assist improves left ventricular systolic function, occurring in only 7 of 11 experiments. This improvement is inconsistent and varied individually. The integrity of the LDM, tightness of wrapping, and adhesions might contribute to the variability which is present early after surgery and before the LDM is converted into a fatigue resistance muscle.

Animals↗

Variable-frequency train stimulation of canine latissimus dorsi muscle during shortening contractions.

In cardiomyoplasty, the latissimus dorsi muscle (LDM) is wrapped around the heart ventricles and electrically activated with a constant-frequency train (CFT). This study tested the hypotheses that increased mechanical performance from the LDM could be achieved by activating the muscle with variable-frequency trains (VFTs) of shorter duration or containing fewer stimulus pulses than the CFT now used. The mechanical performance of the canine LDM (n = 7) during shortening contractions was measured while the muscle was stimulated with 5- and 6-pulse CFTs (of duration 132 and 165 ms, respectively) and 5- and 6-pulse VFTs (of duration 104 and 143 ms, respectively) that were designed to take advantage of the catchlike property of skeletal muscle. Measurements were made from fresh and fatigued muscles. For the fresh muscles, the VFTs elicited significantly greater peak power than did the 6-pulse CFT. When the muscles were fatigued, VFT stimulation significantly improved both the peak and mean power produced compared with stimulation by CFTs. These results show that stimulation of the LDM with shorter duration VFTs is potentially useful for application in cardiomyoplasty.

Animals↗

Overcoming right ventricular failure with left ventricular assist devices.

BACKGROUND: Right ventricular failure can lead to circulatory collapse while on left ventricular assist device support. By shunting blood from the femoral vein to the left ventricular assist device, cardiac output can be increased, but arterial oxygen saturation will decrease. METHODS: To determine the effects on O2 delivery, a model was developed on the basis of O2 uptake in the lungs and whole body O2 consumption. An equation was derived that related cardiac output, pulmonary venous O2 saturation, O2 consumption, and the ratio of shunt-to-systemic blood flow to systemic O2 delivery. RESULTS: When total cardiac output increases, the shunt will increase systemic O2 delivery while decreasing arterial O2 saturation and leaving systemic venous O2 saturation unaltered. When total output does not increase, the shunt will decrease systemic O2 delivery, arterial O2 saturation, and systemic venous O2 saturation. CONCLUSIONS: The analysis suggests that measuring systemic venous oxygen saturation may be a useful way to monitor patient safety. A decrease in systemic venous O2 saturation when creating the shunt implies an inadequate increase in cardiac output.

Cardiac Output↗

Left ventricular contributions to right ventricular systolic function during LVAD support.

BACKGROUND: In patients with postcardiotomy low cardiac output syndromes, right ventricular (RV) failure develops in approximately 25% of patients receiving left ventricular (LV) assist device support. Depressed RV function have been attributed to abnormalities of the RV myocardium, excessive load imposed on the RV during systole or diastole, or obstruction to RV inflow. However, recent studies also suggest that LV function may significantly affect RV function through ventricular interdependence. METHODS: We reviewed the data showing the importance of systolic ventricular interaction. We then related these observations to the RV response during LV assist device support, and present our ideas regarding the mechanisms responsible for this RV failure. RESULTS: Using an electrically isolated right heart preparation, Damiano observed double-peaked waveforms for RV pressure, and pulmonary artery blood flow occurred over a wide range (0 to 300 ms) of pacing intervals between the LV and RV. Numeric analysis indicated that RV systolic pressure and pulmonary artery blood flow were composed of both RV and LV components, with the LV component dominating (63.5% versus 36.5%). CONCLUSIONS: The experimental studies indicate a very consistent RV response during LV assist device support: a decrease in RV afterload, increased compliance, and decreased contractility. In normal hearts, the net effect is an increase or no change in cardiac output. With a preexisting pathologic condition, the RV responses is qualitatively the same, but anatomic ventricular interaction is accentuated, leading to a greater decrease in RV contractility. The net effect is a decrease in cardiac output, which may require inotropic or RV mechanical support.

Animals↗