Error analysis of ultrasonic tissue doppler velocity estimation techniques for quantification of velocity and strain.

Recent work in the field of Doppler tissue imaging has focused mainly on the quantification of results involving the use of techniques of strain and strain-rate imaging. These results are based on measuring a velocity gradient between two points, a known distance apart, in the region-of-interest. Although many recent publications have demonstrated the potential of this technique in clinical terms, the method still suffers from low repeatability. The work presented here demonstrates, through the use of a rotating phantom arrangement and a custom developed single element ultrasound system, that this is a consequence of the fundamental accuracy of the technique used to estimate the original velocities. Results are presented comparing the performance of the conventional Kasai autocorrelation velocity estimator with those obtained using time domain cross-correlation and the complex cross-correlation model based estimator. The results demonstrate that the complex cross-correlation model based technique is able to offer lower standard deviations of the velocity gradient estimations compared with the Kasai algorithm.

Algorithms↗

B-mode compound imaging in mice.

Cross-sectional B-mode images were obtained from a dead mouse for a 360 degrees scan around the mouse using a 12-MHz linear array. For each cross-section, a set of aligned images was obtained after rotation about the isocenter, which were added to produce a single compound image. The compound images demonstrated a substantial improvement over single B-mode images, with uniform image quality, low noise and improved visualization of structures. This technique may be of interest in forming the basis for a new 3-D in vivo technique in the abdomen and pelvic regions, providing high-quality ultrasound images that are not dependent on operator skill. A further development worth pursuing for improved spatial resolution is reconstruction-based tomography.

Animals↗

An anthropomorphic tissue-mimicking phantom of the oesophagus for endoscopic ultrasound.

This study details the design and construct of an anthropomorphic phantom of the oesophagus suitable for use with endoscopic ultrasound (EUS) and 3-D volume measurements. The phantom was constructed using agar-based tissue-mimicking material (TMM) of different acoustical properties to simulate various anatomical and pathologic features. The acoustical properties were measured with a scanning acoustical macroscope. An Olympus GF-UM200 echo-endoscope and digital position measurement arm were used to scan the phantom at 7.5 and 12 MHz. Comparative dimensional measurements were performed on the phantom via 2-D and 3-D EUS. TMM attenuation varied between 0.1 and 0.5 dB/cm.MHz. Backscatter power, relative to normal TMM, was from 0 to -12.2 dB, with an average speed of sound of 1537 +/- 1.9 m/s. Measurements of objects within the phantom by 2-D and 3-D EUS had mean errors of 8% and 2.2%, respectively. The construction of the anthropomorphic EUS phantom facilitated EUS training and research and development studies.

Equipment Design↗

Laser Doppler anemometry measurements of the shear stresses on ultrasonic contrast agent microbubbles attached to agar.

Ultrasonic contrast agents are currently being developed to target and bind to specific areas of interest such as atheromous plaque. A microbubble has been developed in-house which can be targeted to attach to specific cell-lines. To assess the feasibility of using the microbubble in vivo, the shear stresses which the bound microbubbles can withstand need to be known. A flow chamber was developed for use with intravascular ultrasound (IVUS) and laser Doppler anemometry (LDA). Biotin was incorporated into the microbubble shells and streptavidin was used to attach them to agar. IVUS at 40 MHz was then used to image the attached microbubbles under steady flow at a range of flow rates from 75 to 480 mL min(-1) through a flow area of 9 mm(2). LDA was employed to find high resolution velocity profiles of the flow in the chamber at a selection of these flow rates and the shear stresses on the bubbles were calculated. The bubbles were found to remain attached to the agar for shear stresses of up to 3.4 Pa. This compares with mean physiological arterial shear stresses of less than 1.5 Pa for pulsatile flow.

Agar↗

A numerical investigation of the resonance of gas-filled microbubbles: resonance dependence on acoustic pressure amplitude.

The general Keller-Herring equation for free gas bubbles is augmented by specific terms to describe the elasticity, viscosity and thickness of the encapsulating shell in ultrasound contrast agent microbubbles. A numerical investigation that analyses the acoustic backscatter from bubbles is employed to identify resonance frequencies that can be compared, for increasing driving pressure amplitude, with linear approximations obtained via analytical considerations. Calculations for bubbles of the size employed in diagnostic ultrasound, between 2 and 6 mum diameter, that are immersed in water and blood and exposed to monochromatic insonation, causing the bubbles to undergo stable cavitation, reveal that the resonance frequency diverges from the linear approximation as the pressure amplitude is increased. The shift in resonance, to lower frequency values, is found to be more pronounced for larger bubbles with the calculated value differing by up to 40% from the linear approximation. The results of this simulation might be potentially useful in preparation of formulations of ultrasound contrast agents with the specifically desired features, such as for instance resonance frequency.

Journal Article↗

Doppler colour flow imaging and flow quantification with a novel forward-viewing intravascular ultrasound system.

The aim of this work was to investigate the potential of a novel forward-viewing intravascular ultrasound (IVUS) system for flow quantification and colour flow imaging combined with B-mode imaging. A stiff 3.8-mm diameter catheter was used to scan a 72 degrees sector ahead of its tip. Operating at 30 MHz, the catheter was integrated with an IVUS scanner and a radiofrequency (RF) data-acquisition system. RF data were software processed for producing B-mode images and deriving velocity estimates. Steady flow in the range of 45 to 146 mL/min toward the catheter, was used in wall-less tissue-mimicking phantoms simulating healthy lumen (8-mm diameter), 30% diameter symmetrical stenosis and 37% diameter eccentric stenosis. The system provided colour flow images and good estimation of peak velocity and volumetric flows (within 1% to 9% and 16% to 48%, respectively, of calculated values) at 5 to 7 mm distal to the catheter. A sector forward-viewing IVUS imaging/Doppler system is suitable for combined anatomical and functional assessment of stenosed vessels.

Blood Flow Velocity↗