Search PubMedSearch

Biomedical subjects

W Noble

Publications and source records attributed to W Noble.

11 recordsLinked to original sources

Language gap.

Explore the source record for details and available documents.

Animals

Effects of long-term bilateral and unilateral fitting of different hearing aid types on the ability to locate sounds.

Aided localization ability of 87 hearing-impaired listeners was tested for horizontal and vertical sound sources, at two signal levels, and for two orientations to the loudspeaker array (facing, sideways). Some listeners wore behind-the-ear (BTE) aids, others in-the-ear (ITE) aids. Some were bilaterally fitted, others unilaterally fitted. Listeners were tested only with types of aids and fittings that they were accustomed to wearing. The results strongly supported bilateral fitting for moderately and severely hearing-impaired listeners. However, for mildly impaired listeners, those fitted unilaterally performed as well, on average, as those fitted bilaterally. This suggests a need to consider individual listening requirements and also to provide such listeners with experience in unilaterally-aided listening before assessing the possible advantages of bilateral fitting. When hearing level was controlled, there was no overall difference in the performance of ITE and BTE aid wearers. This discrepancy with other research may be explained by measures (removal of intensity cues, permitting of head movement) designed to make the test situation more representative of real-life listening.

Adult

Auditory localization under conditions of unilateral fitting of different hearing aid systems.

The spatial localization function of hearing-impaired listeners, usually fitted bilaterally with BTE, ITE or ITC devices, was tested under conditions of unilateral fitting of each of their own hearing aids, and unilateral fitting of stock versions of each of the other types. For the BTE wearers average localization accuracy and individual variability were not greatly changed when wearing only their left ear device, compared with bilateral aided performance. In ITE wearers, unilateral fitting in either ear led to somewhat poorer performance than bilateral. In the ITC wearers unilateral fitting produced inconsistent outcomes. Both BTE and ITE wearers fared poorly when fitted unilaterally with stock forms of devices 'foreign' to them, whereas ITC wearers did not show such a contrasting outcome. A group of non-impaired listeners showed severe disruption of localization under unilateral BTE and ITC hearing aid conditions, and to a lesser extent with ITEs. Results for the hearing-impaired listeners are interpreted in terms of adaptation to different usage patterns, with BTE wearers suggested as having adapted to their own systems unilaterally as well as bilaterally.

Auditory Threshold

The effect of various hearing protectors on sound localization in the horizontal and vertical planes.

Listeners were tested under free head/torso movement conditions, using a brief pulsed broadband noise signal presented from any 1 of 20 loudspeakers in two intersecting hemicircumferential arrays: one in the horizontal plane, one in the vertical. The listeners' task was to judge the whereabouts of each signal while listening in normal, open-ears conditions or while wearing various types of standard or electronic earmuffs or compressible foam earplugs. Results showed that listeners could accomplish the task successfully in normal (open-ear) conditions. Results using earplugs, nonelectronic earmuffs, and two types of dichotic (dual microphone) electronic earmuffs showed decrements in performance similar to each other. These decrements took the general form of loss of appreciation of the vertical plane and of front-rear differences in the horizontal plane. Lateral discrimination was blurred but otherwise intact. Of two diotic (single microphone) electronic earmuffs, one completely disrupted localization function and the other came close to it.

Auditory Perception

A comparison of different binaural hearing aid systems for sound localization in the horizontal and vertical planes.

Three groups of hearing-impaired listeners who had been fitted binaurally with behind-the-ear (BTE), in-the-ear (ITE), or in-the-ear-canal (ITC) hearing aids were tested on spatial localization function for sources in the frontal horizontal and vertical planes. No significant differences in unaided performance were observed between the groups, nor between that and aided performance in the BTE and ITE wearers. ITC wearers, by contrast, showed a deterioration in aided over unaided performance. From observations of performance when each group wore temporary fittings of the other two types of system, and from the performance of a non-impaired control group, it appears that the performance decrement for the ITC wearers was due to their own particular systems although specific reasons for this decrement could not be identified. In all conditions, aided and unaided, vertical plane localization was markedly disrupted in all the hearing impaired groups. It was also disrupted, to a lesser but still substantial extent, in aided conditions for the non-impaired listeners.

Adult

Staff carriage of epidemic methicillin-resistant Staphylococcus aureus.

Twenty-six nurses were repeatedly screened for carriage of epidemic methicillin-resistant Staphylococcus aureus (EMRSA) immediately before and after duty periods in which they solely attended six patients widely colonized with two EMRSA strains distinguishable by plasmid analysis. EMRSA carriage was detected in 13 nurses. Three EMRSA carriage patterns emerged: transient carriage in 12 nurses, when the EMRSA was isolated from noses or fingers of nurses after duty but was gone before their next day's duty; short-term nasal carriage, seen on occasion in 4 of these 12 nurses, when EMRSA carriage was detected on two consecutive screens; and persistent nasal carriage, seen in 1 nurse only, when the EMRSA was seen on more than two consecutive occasions. All but one of these incidents of carriage could be explained by close patient, rather than environmental, exposure and occurred despite an intensive control programme. Transient or short-term carriage in nurses probably resulted in transfer of the EMRSA between patients. Staff decontamination should be considered following a period of cohort nursing of EMRSA patients, especially if staff members are shortly to nurse unaffected patients. Our findings may explain some of the difficulties in controlling EMRSA.

Air Microbiology

Effect of oxprenolol on some fear-induced behavioral responses and hyperthermia in rats subjected to inescapable shocks.

The effect of oxprenolol (100 mg/kg p.o.) on the development of hyperthermia in a shock enclosure and on exploratory and grooming responses in an exploration box, was investigated in rats subjected to inescapable shocks once daily for 5 days. The hyperthermic response of shocked rats was found to be significantly reduced by oxprenolol treatment. Exploratory behavior, which was suppressed by previous exposure to shocks, was not influenced by oxprenolol. However, under oxprenolol treatment grooming diminished from the first day of the trial onward, both in duration and frequency, as though habituation had occurred. The results are interpreted as evidence of partial effectiveness of oxprenolol in suppressing fear-induced somatic and behavioral manifestations.

Animals