Publications and source records attributed to W Mokwa.

4 recordsLinked to original sources

[Epiretinal visual prostheses].

Epiretinal implants consist of a camera chip capturing the scene, a visual processor calculating retina-specific pulse sequences, a transponder for data and energy, and the implant itself. The implant consists of a receiver integrated into a posterior chamber lens, a microcable, and the retina stimulator. The stimulator is fixated onto the retinal surface using retinal tacks. In animal experiments it was shown that the materials being used were tolerated, the data and energy stream did not induce any adverse events, and that the fixation was feasible using retinal tacks. Stimulation of the inner retinal surface yielded a topographically correct activation of visual cortical areas. Even after a long history of blindness, tests in humans disclosed visual percepts.

Animals↗

Vascular capsule for telemetric monitoring of blood pressure.

PURPOSE: Development and experimental evaluation of an intravascular monitoring system for telemetric measurement of blood pressure and heart rate. MATERIALS AND METHODS: The monitoring system consists of an implantable silicone capsule (diameter 2.3 mm), containing a dedicated microchip with pressure sensors and signal-processing circuits as well as an antenna for wireless data and energy transfer using 6.78 MHz transponder technology. Three self-expanding legs at one end of the capsule served as a mechanism to lock the capsule at an arterial branch. A flow model, driven by a ventricular assist system, was used for testing and optimizing the implantation equipment, for checking the anchoring mechanism and for ensuring transmission of the measured pressure to the readout unit. In-vivo experiments were performed in 8 minipigs (weight 25 to 30 kg), with three capsules placed in each minipig via the femoral artery using a dedicated 8-F sheath/pusher system. Follow-up was by CT angiography for up to 6 months after implantation. RESULTS: Flow model tests revealed a maximum deviation of pressure and heart rate measurements of 5% from the reference measurements. Signal transmission was reliable over a distance of 3 to 4 cm. Fluoroscopically guided in-vivo implantation of the capsules was simple and straightforward. In arteries with a diameter of 5 to 6 mm, the capsules were permanently fixed with one or two legs interlocked in side branches and without occlusion within 6 months. Three capsules developed a small non-occlusive appositional thrombus attached to the downstream (leg) part of the capsule. CONCLUSION: Our in-vitro and in-vivo experiments demonstrate the feasibility of wireless transmission from a capsule with a sufficient resolution of the sensor output signals to determine blood pressure and pulse rate. As long as the vessel diameter is wide enough, arterial fixation of the capsule does not induce thrombotic occlusion of the parent artery. With respect to future clinical applications, further refinements of the transmission technology are needed to extend the transmission distance between capsule and reader antenna. The technology of intelligent implants has further implications, such as monitoring of other physiological parameters, and the design of a control loop, which may be used for therapeutic feedback.

Animals↗

Transponder system for non-invasive measurement of intravascular pressure.

Monitoring of blood pressure and pulse rate offers diagnostical and therapeutical opportunities in hypertension disease and arrhythmia, respectively. This paper presents an intravascular pressure monitoring system consisting of an implantable silicone capsule, which can be placed in an arterial system via a catheter. The capsule contains a pressure sensor and signal conditioning circuits for wireless data and energy transfer using 6.78 MHz transponder technology.

Blood Pressure Monitors↗

Development of a completely encapsulated intraocular pressure sensor.

A completely encapsulated intraocular pressure (IOP) sensor equipped with telemetric signal and energy transfer is introduced integrated into a silicone disc for implantation into the eye. After implantation into enucleated pig eyes and into rabbit eyes in vivo, the IOP was recorded and compared to established techniques of IOP measurement. Pressure chamber tests showed that the sensor functioned correctly after biocompatible encapsulation in polydimethylsiloxane. In vivo and in vitro tests in rabbit and pig eyes demonstrated that the implanted system worked with the same precision as established techniques for IOP determination. The correlation between the measurements with the implanted device and pneumotonometry in several experiments was between 0.9 and 0.99. This device serves as a functioning model for the realization of a telemetric IOP sensor for integration into an artificial intraocular lens. Such a device will open new perspectives, not only in the management of glaucoma, but also in basic research for mechanisms of glaucoma.

Animals↗