Search PubMed⌕ Search

Biomedical subjects

W M Smith

Publications and source records attributed to W M Smith.

At least 127 records · Page 7Linked to original sources

Visualization of bioelectric phenomena.

Biomedical investigators are currently able to acquire and analyze physiological and anatomical data from three-dimensional structures in the body. Often, multiple kinds of data can be recorded simultaneously. The usefulness of this information, either for exploratory viewing or for presentation to others, is limited by the lack of techniques to display it in intuitive, accessible formats. Unfortunately, the complexity of scientific visualization techniques and the inflexibility of commercial packages deter investigators from using sophisticated visualization methods that could provide them added insight into the mechanisms of the phenomena under study. Also, the sheer volume of such data is a problem. High-performance computing resources are often required for storage and processing, in addition to visualization. This chapter describes a novel, language-based interface that allows scientists with basic programming skills to classify and render multivariate volumetric data with a modest investment in software training. The interface facilitates data exploration by enabling experimentation with various algorithms to compute opacity and color from volumetric data. The value of the system is demonstrated using data from cardiac mapping studies, in which multiple electrodes are placed in an on the heart to measure the cardiac electrical activity intrinsic to the heart and its response to external stimulation.

Algorithms↗

Surgical correction of the Wolff-Parkinson-White syndrome.

The results of corrective surgery in 75 consecutive patients with Wolff-Parkinson-White (WPW) syndrome are reported. There were 47 male and 28 female patients with a median age of 27 years. Intraoperative mapping disclosed 88 accessory pathways, of which 83 were successfully divided at the primary operation without mortality. Two patients underwent successful reoperation at three days and two years respectively. Patient success rates were 93% and 96% for first and total operations. Complications, usually minor, occurred in 20 patients, including permanent pacemaker implantation in two. Surgical correction of WPW syndrome is recommended as a safe alternative to lifelong medical treatment.

Adolescent↗

The use of benazepril in hypertensive patients age 55 and over.

Benazepril, a newer angiotensin-converting enzyme inhibitor, has been evaluated for the treatment of mild to moderate hypertension in patients 55 years of age and older. The results of the clinical trials conducted to date indicate that benazepril provides effective antihypertensive therapy in this population, with efficacy comparable to that demonstrated in younger patients. Benazepril does not produce precipitous decreases in diastolic blood pressure following the initial dose, and is well tolerated by the elderly. It has a safety profile similar to that of placebo and generally better than that of hydrochlorothiazide.

Aged↗

Prevalence of postural hypotension at baseline in the Systolic Hypertension in the Elderly Program (SHEP) cohort.

OBJECTIVE: The objective of this study was to examine the prevalence and correlates of postural hypotension (defined as a drop in systolic blood pressure of greater than or equal to 20 mm Hg) in a cohort of elderly persons with isolated systolic hypertension (ISH). DESIGN: Baseline cross-sectional analysis of the 4,736 persons randomized in the Systolic Hypertension in the Elderly Program (SHEP). SETTING: A randomized multi-center double-blind outpatient clinical trial of the impact of treating ISH. PARTICIPANTS: Men and women age greater than or equal to 60 years with the systolic blood pressure (SBP) greater than or equal to 160 mm Hg and diastolic blood pressure (DBP) less than 90 mm Hg. MEASURES: Medical histories were obtained using interviewer-administered, standardized clinical history forms. At entry into the study, seated and standing BP was measured by certified BP technicians using a random zero sphygmomanometer. Postural hypotension (PH) was assessed at 1 and 3 minutes after the participant arose from a seated position. MAIN RESULTS: PH was found in 10.4% of participants at 1 minute and in 12.0% of participants at 3 minutes. 5.3% of participants demonstrated PH at both time intervals while 17.3% demonstrated PH at either or both of the time intervals. Factors significantly (P less than 0.05) associated with the presence of PH were higher mean SBP and a lower mean body mass index. CONCLUSIONS: Somewhat different persons were defined as having PH based upon the 1 minute and 3 minute standing measures of BP, and prevalence estimates of PH can vary depending on whether one or more intervals of measurement are used. Cross-sectional data analysis indicated that PH, in healthy community-dwelling older persons with ISH, may not be associated with a history of disorders or problems usually thought to be related to PH. However, prospective data are needed to determine the prognostic significance of PH, and whether one or multiple measurements carry more significance.

Aged↗

Dispersion of repolarization induced by a nonuniform shock field.

Dispersion of repolarization may contribute to arrhythmias. To determine whether an electrical field stimulus (S2) with a nonuniform potential gradient can induce a dispersion of repolarization, we applied 5 ms rectangular S2 that had a nonuniform or uniform potential gradient during the action potential (AP) of bathed frog ventricular strips. One group had a partitioned bath to produce a nonuniform S2 of 39 +/- 11 V/cm (mean +/- SD) in one half of the 1 x 6 mm strip (H) and 0.3 +/- 0.2 V/cm in the other half (L), and simultaneous intracellular AP recordings in H and L with glass microelectrodes positioned 1.4 +/- 0.4 mm apart. Another group had uniform S2 and an AP recorded near the center of the strip. S1 pacing at 0.5 Hz was performed at one end of the strip and conduction along the strip was monitored. In each experiment, the S2 trials had an S1-S2 interval of 300 ms so that S2 was given during an AP (shocked AP). In both H and L, nonuniform S2 produced cumulative shortening of paced APs and lengthening of each shock AP compared with the paced AP preceding it. Uniform S2 of 1 V/cm did not shorten the paced APs or lengthen the shocked APs indicating that the AP changes in L were not due to the small potential gradient in L. Before beginning nonuniform S2 trials, the AP duration determined at the maximum repolarization rate was 601 +/- 72 ms in H and 602 +/- 71 ms in L (P = ns). During 13-20 nonuniform S2 trials over a 60-80 minute period, paced APs were shortened to 490 +/- 51 ms in H and 515 +/- 39 ms in L while each shocked AP was lengthened, compared with the paced AP preceding it, to 636 +/- 40 ms in H and 561 +/- 21 ms in L (P less than 0.05). Therefore, paced APs after shocks repolarized 25 ms earlier in H than in L and shocked APs repolarized 75 ms later in H than in L. The results show that during the shortened AP in H, the AP in L is shortened, which is consistent with intracellular current from L to H during repolarization. During the prolonged AP in H, the AP in L is prolonged compared with the paced AP preceding it, consistent with intracellular current from H to L during repolarization. Thus, nonuniform shocks can induce a dispersion of repolarization and may induce cell-to-cell interactions during repolarization.

Action Potentials↗

Defibrillation with low voltage using a left ventricular catheter and four cutaneous patch electrodes in dogs.

The purpose of this study was to determine a lower limit of defibrillation thresholds (DFTs) that could be used to evaluate nonthoracotomy lead configurations for implantable defibrillators. A lead configuration that consisted of a left ventricular catheter and four circumferential cutaneous patches was tested because it was hypothesized to create a relatively uniform electric field for defibrillation. In eight anesthetized dogs, three 8F defibrillating catheters with 6 cm platinum clad titanium tips were inserted into the right ventricle (R), right ventricular outflow tract (O), and left ventricle (L). Four cutaneous patch electrodes (4P), each with a surface area of 42 cm2, were placed on the left lateral, right lateral, anterior and posterior thorax. DFTs for ten lead configurations, consisting of different combinations of these electrodes, were evaluated. DFTs were determined by using a modified Purdue technique and applying a single capacitor biphasic shock with both phases 6 ms in duration after 15 sec of electrically induced fibrillation. The L(-)----4P+ configuration produced a lower DFT than R(-)----4P+ (3.2 +/- 1.6 J vs 8.0 +/- 4.2 J, P less than 0.001) with reduced current (2.6 +/- 0.7 A vs 4.1 +/- 1.2 A, P less than 0.001). Lowering the impedance by a mean of 40%, configurations that used four patches produced lower DFTs than those that used a single left lateral patch. The use of an O catheter produced lower DFTs only when used in conjunction with an R catheter.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Response of relatively refractory canine myocardium to monophasic and biphasic shocks.

BACKGROUND: Certain biphasic waveforms defibrillate at lower energies than monophasic waveforms, although the mechanism is unknown. METHODS AND RESULTS: The relative ability of monophasic and biphasic shocks to stimulate partially refractory myocardium was compared because defibrillation is thought to involve stimulating relatively refractory myocardial tissue. Shocks of 25-125 V were given during regularly paced rhythm in 11 open-chest dogs. Computerized recordings of shock potentials, and of activations before and after the shocks, were made at 117 epicardial sites. To quantify the shock field strength, the shock potential gradients were calculated at the electrode sites. Monophasic action potential (MAP) electrode recordings, obtained in five dogs, confirmed direct myocardial excitation by the shock, that is, activations beginning during the shock. Tissue was directly excited up to 4 cm from the shocking electrode, and the area directly excited increased as the shock was made stronger or given less prematurely. In six dogs, strength-interval curves for direct excitation were determined from plots of potential gradient versus refractoriness at each electrode site. The biphasic curves were located to the right of the monophasic curves by 8 +/- 4 msec, indicating a lesser ability to excite refractory myocardium. When the gradient at the directly excited border was at least 3.8 +/- 1 V/cm, conduction failed to propagate away from the directly excited zone after the shock, and MAP recordings made near the border showed a shock-induced graded response. This graded response, which prolonged repolarization, may have been responsible for the failure of conduction from the directly excited zone. Although better for defibrillating, the biphasic waveform was thus less effective than the monophasic one in exciting relatively refractory myocardium. CONCLUSIONS: These results indicated that waveform selection for defibrillation should not be guided solely by the ability of the waveform to stimulate tissue, as these two properties can be discordant.

Action Potentials↗

Prolongation of repolarization time by electric field stimulation with monophasic and biphasic shocks in open-chest dogs.

Recent studies suggest that 1) electrically induced fibrillation and defibrillation involve prolongation of refractoriness by the shock in addition to stimulation and 2) biphasic waveforms are more efficient for defibrillation than are comparable monophasic waveforms. The purpose of this study was to compare prolongation of action potential duration at 50% repolarization by monophasic and biphasic shocks during paced rhythm. A floating glass microelectrode was used to record intracellularly from the anterior right ventricular epicardium in seven open-chest dogs. After 10 S1 beats paced at an interval of 350 msec, 5-msec and 2.5-msec monophasic shocks and biphasic shocks, with each phase of 2.5 msec, were given via mesh electrodes on either side of the microelectrode. The shock strength was adjusted so that the shock field, measured from eight extracellular electrodes encircling the microelectrode, was about 5 V/cm. Monophasic and biphasic S2 shocks were given starting with an S1-S2 interval of 120 msec, which was increased in 5-msec steps until an action potential was produced by the S2 shock. Both monophasic and biphasic 5 V/cm shock fields caused significant prolongation of action potential duration. The prolongation of action potential duration increased as the S1-S2 interval increased. This prolongation occurred at shorter S1-S2 intervals for 5-msec monophasic shocks than for biphasic shocks.

Action Potentials↗

Operations for Wolff-Parkinson-White syndrome.

Forty-six patients with symptomatic tachycardia underwent operations to divide 55 atrioventricular accessory pathways. Mean age was 29 years (range 11 to 63). Ten patients (22%) had associated cardiac disease, including two with a congenital diverticulum of the coronary sinus and six (13%) who had concomitant surgical procedures. A bipolar hand-held electrode was used in 22 operations, and simultaneous multisite mapping in the last 24 operations. Ten patients (22%) had multiple accessory pathways. A modified endocardial approach was used. The overall patient success rate was 93% with 91% to 93% of accessory pathways successfully divided. The perioperative morbidity was 17%. There were two reoperations. There were no early or late deaths. Patients have been followed up for a mean of 16 months. There were five recurrences of preexcitation (two early, three late). Two of these patients (both with a congenital diverticulum of the coronary sinus) had reoperation. One patient had late recurrence of atrial fibrillation. Operation for the Wolff-Parkinson-White syndrome has a high probability of success with a low operative risk.

Adolescent↗

Activation in unipolar cardiac electrograms: a frequency analysis.

We have developed and tested several detectors of local activations in unipolar cardiac electrograms; the detectors are based on the frequency content of the waveforms. For this study, myocardial regions with no local electrical activity were created with cryoablation in canine ventricles, so that the characteristics of electrograms reflecting local activation could be compared with those with only distant electrical activity. For each electrogram, representations of the original signal were created using the output of bandpass filters; for each representation, the value of the maximum amplitude was taken as a measurement of the frequency content of the electrogram in that frequency band. The content of each frequency band and the first derivative of the signal were tested as discriminators between local and distant electrical activity. Combinations of frequency bands were also tested using a logistic regression technique; certain combinations provided better detection than any of the individual frequencies or the first derivative. The inclusion of frequencies between 500 and 1000 Hz improved the detection performance, suggesting that sampling rates of 1000 samples per second or less may not be adequate for optimal discrimination. A detector based on multivariate analysis of different frequency components of a signal may be more effective than single-band filtering in discriminating between local and distant electrical activity in the heart, especially when those components have very different magnitudes.

Algorithms↗

Electrophysiological effects of monophasic and biphasic stimuli in normal and infarcted dogs.

Though some biphasic waveforms significantly decrease the energy required for defibrillation, little is known about the effect of biphasic stimulation on the determination of other electrophysiological parameters in normal and infarcted hearts. To evaluate this, nine normal dogs and 12 dogs with myocardial infarction had activation threshold (AT), effective refractory period (ERP), strength-interval curves, and ventricular fibrillation threshold (VFT) determined with constant current stimulation to a pair of right ventricular plunge electrodes, and upper limit of vulnerability (ULV) and defibrillation threshold (DFT) determined with truncated exponential shocks delivered to a pair of wire electrodes coiled to contour the right and left ventricular epicardium. Each electrophysiological parameter was determined with a 5.5 msec monophasic and 5.5-msec biphasic (3.5 msec first phase) waveform. Though AT and VFT were not significantly different for the two waveforms, the ERP was significantly longer, the strength-interval curve shifted rightward, and the threshold for repetitive responses higher for biphasic stimuli. Compared to the monophasic waveform, the ULV and DFT were significantly decreased in a parallel fashion for the biphasic waveform. Neither the presence nor size of myocardial infarction significantly affected any of the measured electrophysiological parameters. In six additional dogs, sigmoid defibrillation probability curves were constructed from biphasic shocks of four energies including that of the DFT and ULV. The ULV energy predicted an effective dose that defibrillated 97% of the time (range 90%-100%). In conclusion, the increased defibrillation efficacy of the biphasic waveform is independent of its ability to activate fully repolarized myocardium and cannot be explained by a greater ability of biphasic waveforms to activate partially depolarized tissue. The parallel decrease in the ULV and DFT for biphasic stimulation and the finding that the ULV energy defibrillates with a high probability of success suggest similar underlying mechanisms for the ULV and defibrillation.

Animals↗

Strength-duration and probability of success curves for defibrillation with biphasic waveforms.

Certain biphasic waveforms require less energy to defibrillate than do monophasic pulses of equal duration, although the mechanisms of this increased effectiveness remain unclear. This study used strength-duration and percent success curves for defibrillation with monophasic and biphasic truncated exponential waveforms to explore these mechanisms. In part 1, defibrillation thresholds were determined for both high- and low-tilt waveforms. The monophasic pulses tested ranged in duration from 1.0 to 20.0 msec, and the biphasic waveforms had first phases of either 3.5 or 7.0 msec and second phases ranging from 1.0 to 20.0 msec. In part 2, defibrillation percent success curves were constructed for 6.0 msec/6.0 msec biphasic waveforms with a constant phase-one amplitude and with phase-two amplitudes of approximately 21%, 62%, 94%, and 141% of phase one. This study shows that if the first phase of a biphasic waveform is held constant and the second phase is increased in either duration or amplitude, defibrillation efficacy first improves, then declines, and then again improves. For pulse durations of at least 14 msec, the second-phase defibrillation threshold voltage of a high-tilt biphasic waveform is higher than that of a monophasic pulse equal in duration to the biphasic second phase (p less than 0.05), indicating that the previously proposed hypothesis of stimulation by the second phase is not the sole mechanism of biphasic defibrillation. These facts indicate the importance of the degree of tilt for the defibrillation efficacy of biphasic waveforms and suggest at least two mechanisms exist for defibrillation with these waveforms, one that is more effective for smaller second phases and another that becomes more effective as the second phase is increased.

Animals↗

Conduction disturbances caused by high current density electric fields.

During internal defibrillation, potential gradients greater than 100 V/cm occur near defibrillation electrodes. Such strong fields may cause deleterious effects, including arrhythmias. This study determined 1) the effects of such strong fields on the propagation of activation and 2) whether these effects were different for monophasic and biphasic shocks. Voltages and potential gradients during the shock, as well as activation sequences before and after the shock, were mapped from 117 epicardial electrodes placed over a 3 x 3-cm area on the right ventricle in six dogs. Pacing at a cycle length of 350 msec was given from a long narrow electrode on the right side of the mapped area to generate parallel activation isochrones. A monophasic shock, 10 msec in duration, or a biphasic shock with both phases 5 msec in duration was delivered 300 msec after the last paced stimulus via a mesh electrode on the left side of the mapped area as the cathode, with the anode on the right atrium. Shocks of 70-850 V were given, and the potential gradient and current density at each recording electrode were calculated from the measured potentials and fiber orientation by using a finite element method. Pacing was resumed 200 msec after the shock, and activation sequences were mapped for up to 5 minutes. Potential gradients ranged from 1 to 189 V/cm with high fields on the left side and low fields on the right side of the mapped area. Where the potential gradient was weak, the first activation sequence after the shock was similar to that before the shock, but activation blocked without conducting into areas where the gradient was greater than 64 +/- 4 (mean +/- SD) V/cm for monophasic and greater than 71 +/- 6 V/cm for biphasic shocks. These values are significantly different (p less than 0.003). The higher the potential gradient, the longer was the duration of block before conduction returned. Block duration, however, was generally shorter for biphasic than for monophasic waveforms of the same field strength. In conclusion, conduction block can follow either waveform, but biphasic waveforms cause less block than monophasic waveforms. This effect may partially explain the increased defibrillation efficacy of biphasic shocks.

Animals↗

Comparison of activation during ventricular fibrillation and following unsuccessful defibrillation shocks in open-chest dogs.

The purpose of this study was to map in detail the spread of activation away from sites of early postshock excitation following unsuccessful defibrillation to determine whether these activation fronts are the unaltered continuation of activation fronts present just before the shock. We recorded simultaneously from 120 bipolar electrodes on 40 plunge needles in a 20 x 35 x 5-mm volume of tissue of the right ventricular outflow tract immediately before and after shocks of 190-350 V were given via electrodes on the right atrium and left ventricular apex to six open-chest dogs with electrically induced ventricular fibrillation. For 20 shocks approximately 100 V below the defibrillation threshold, the site of earliest recorded activation following the shock was near the center of the mapped region. At the earliest recorded activation sites, there was an isoelectric window in the immediate postshock period lasting 42 +/- 15 msec after which activation fronts either spread away from a site in all directions in a focal pattern (12 episodes) or else spread away in only one direction (eight episodes). Comparison of activation patterns immediately before and after the shock revealed that in 18 of the 20 episodes, the location and pathway of activation fronts after the shock were markedly different from those before the shock. The preshock intervals at the sites of earliest activation following the shock, that is, the interval between the last activation at the site and the time of the shock, were not randomly distributed but were similar, averaging 64 +/- 11 msec, and were negatively correlated with the isoelectric postshock window (r = -0.70, p = 0.0001). These findings indicate that the presence and the site of origin of activation fronts after the shock are influenced by at least two factors: the shock itself and the electrophysiological state of the myocardium at the time of the shock. Thus, epicardial shocks approximately 100 V below the defibrillation threshold markedly alter the activation sequences of fibrillation but are unsuccessful because the activation fronts following the shock reinitiate fibrillation.

Animals↗