Architecture of the rectus abdominis, quadratus lumborum, and erector spinae.

Quantitative descriptions of muscle architecture are needed to characterize the force-generating capabilities of muscles. This study reports the architecture of three major trunk muscles: the rectus abdominis, quadratus lumborum, and three columns of the erector spinae (spinalis thoracis, longissimus thoracis and iliocostalis lumborum). Musculotendon lengths, muscle lengths, fascicle lengths, sarcomere lengths, pennation angles, and muscle masses were measured in five cadavers. Optimal fascicle lengths (the fascicle length at which the muscle generates maximum force) and physiologic cross-sectional areas (the ratio of muscle volume to optimal fascicle length) were computed from these measurements. The rectus abdominis had the longest fascicles of the muscles studied, with a mean (S.D.) optimal fascicle length of 28.3 (4.2)cm. The three columns of the erector spinae had mean optimal fascicle lengths that ranged from 6.4 (0.6)cm in the spinalis thoracis to 14.2 (2.1)cm in the iliocostalis lumborum. The proximal portion of the quadratus lumborum had a mean optimal fascicle length of 8.5 (1.5)cm and the distal segment of this muscle had a mean optimal fascicle length of 5.6 (0.9)cm. The physiologic cross-sectional area of the rectus abdominis was 2.6 (0.9)cm(2), the combined physiologic cross-sectional area of the erector spinae was 11.6 (1.8)cm(2), and the physiologic cross-sectional area of the quadratus lumborum was 2.8 (0.5)cm(2). These data provide the basis for estimation of the force-generating potential of these muscles.

Aged↗

A transducer to measure isometric elbow moments.

OBJECTIVE: The purpose of this study was to design and implement a transducer to measure accurately the isometric elbow moments produced by individuals with tetraplegia. DESIGN: The device needed to be insensitive to off-axis moments and proximal joint motions and be capable of being used over a wide range of elbow and shoulder positions in an outpatient clinic setting. BACKGROUND: Measurement of the smaller isometric moments produced by individuals with tetraplegia is especially sensitive to the errors that can be introduced by inaccurate lever arm determination, off-axis loads, and proximal joint motions. Devices traditionally utilized for quantifying isometric strength are difficult to implement for the spinal cord injured population. METHODS: The elbow moment transducer consists of two four-bar parallelogram linkages joined by a lockable pivot. Strain gauges mounted on one beam of the parallelogram produce an output proportional to the elbow moment. RESULTS: Calibration of the device indicates that it accurately quantifies isometric elbow moments over a range that is appropriate for evaluating elbow extension strength in individuals with tetraplegia. CONCLUSIONS: A device was developed and implemented that accurately quantifies isometric elbow moments over a range that is appropriate for evaluating elbow extension strength in individuals with tetraplegia. RELEVANCE: The ability to quantitatively evaluate elbow strength in persons with tetraplegia is useful for understanding and improving the clinical outcomes of rehabilitative interventions that involve the elbow.

Calibration↗

The isometric functional capacity of muscles that cross the elbow.

We hypothesized that muscles crossing the elbow have fundamental differences in their capacity for excursion, force generation, and moment generation due to differences in their architecture, moment arm, and the combination of their architecture and moment arm. Muscle fascicle length, sarcomere length, pennation angle, mass, and tendon displacement with elbow flexion were measured for the major elbow muscles in 10 upper extremity specimens. Optimal fascicle length, physiological cross-sectional area (PCSA), moment arm, operating range on the force-length curve, and moment-generating capacity were estimated from these data. Brachioradialis and pronator teres had the longest (17.7cm) and shortest (5.5cm) fascicles, respectively. Triceps brachii (combined heads) and brachioradialis had the greatest (14.9cm(2)) and smallest (1.2cm(2)) PCSAs, respectively. Despite a comparable fascicle length, long head of biceps brachii operates over a broader range of the force-length curve (length change=56% of optimal length, 12.8cm) than the long head of triceps brachii (length change=28% of optimal length, 12. 7cm) because of its larger moment arm (4.7cm vs. 2.3cm). Although brachioradialis has a small PCSA, it has a relatively large moment-generating capacity (6.8cm(3)) due to its large moment arm (average peak=7.7cm). These results emphasize the need to consider the interplay of architecture and moment arm when evaluating the functional capabilities of a muscle.

Elbow↗

Variation of muscle moment arms with elbow and forearm position.

We hypothesized that the moment arms of muscles crossing the elbow vary substantially with forearm and elbow position and that these variations could be represented using a three-dimensional computer model. Flexion/extension and pronation/supination moment arms of the brachioradialis, biceps, brachialis, pronator teres, and triceps were calculated from measurements of tendon displacement and joint angle in two anatomic specimens and were estimated using a computer model of the elbow joint. The anatomical measurements revealed that the flexion/extension moment arms varied by at least 30% over a 95 degrees range of motion. The changes in flexion/extension moment arm magnitudes with elbow flexion angle were represented well by the computer model. The anatomical studies and the computer model demonstrate that the biceps flexion moment arm peaks in a more extended elbow position and has a larger peak when the forearm is supinated. Also, the peak biceps supination moment arm decreases as the elbow is extended. These results emphasize the need to account for the variation of muscle moment arms with elbow flexion and forearm position.

Biomechanical Phenomena↗

Digitalis toxicity.

Explore the source record for details and available documents.