Perspective and limitations of cryo-electron microscopy. From model systems to biological specimens.

We investigated the possibility of vitrifying temperature-sensitive lipid phases as well as (small) biological specimens. From a suspension of unilamellar vesicles, prepared from dipalmitoyl-phosphatidylcholine (DPPC), thin aqueous films were formed at various temperatures. With cryo-electron microscopy vesicles were found to be smooth, rippled and faceted or faceted only, depending on the temperature of thin-film formation (318, 312 and 296 K respectively). The morphology and the electron diffraction patterns indicate that membranes can by physically fixed by vitrification in their high-temperature configuration and studied at low temperature by cryo-electron microscopy. This finding suggests that it may also be possible to preserve, in their original state, the more complex membrane systems found in living organisms by initiating rapid-cooling at a physiological temperature. This was explored by vitrification of thin films formed on specimen grids with (human) blood platelets adhering to collagen fibres. Low-temperature observation with an acceleration voltage of 120 kV revealed subcellular details, More details were observed when using higher accelerating voltages (200 and 300 kV) of the electron beam. The results presented in this paper illustrate the great potential of cryo-electron microscopy in the study of membrane dynamics, both in relatively simple model membrane systems and in more complex biological membrane systems.

Blood Platelets↗

Phospholipid, nature's own slide and cover slip for cryo-electron microscopy.

Thin films of surface-active compounds, with or without particulate material, can be obtained by immersing and withdrawing a bare specimen grid from a solution/suspension of the compound. Immediately after withdrawing the grid, thinning of the film starts. Thinning is initially powered by gravity and capillary forces and will proceed in thin films (less than 100 nm) driven by intermolecular forces until the London-van der Waals attractive forces come to an equilibrium with electrostatic repulsion of similarly charged surfaces of the film. With small unilamellar vesicles prepared from the phospholipid dimyristoyl phosphatidyl choline (DMPC) the draining behaviour of these films was studied by cryo-electron microscopy. Small unilamellar vesicles were observed within the film as well as the coalescence of these vesicles into sheets ('leaky' membrane fusion). Sheets dominate the images when films are allowed to drain for longer periods (greater than 3 min). Thin films were formed on grids from catalase crystals suspended in a DMPC suspension and vitrified by cooling. High-resolution information was obtained by electron diffraction at low temperature and under low-dose conditions from catalase crystals surrounded by small vesicles as well as from catalase crystals surrounded by sheets of DMPC. In the latter case the water content drops from 99% (DMPC in small vesicles) to less than 30% (DMPC in sheets) during draining. Ferritin was added to a DMPC suspension and thin films were prepared and vitrified. After prolonged draining ferritin molecules were deposited in layers with a stepwise increase in thickness. Draining of thin films has thus a dehydrating effect as well as a sorting and ordering effect. These effects must be considered when using surface-active compounds at air-water interfaces as a slide and cover slip for electron microscopy.

Catalase↗

Cryo-transfer revised.

Vapour deposition of water is a major problem in cryo-transfer and cryo-observation of frozen specimens. The use of (sliding) shields to protect the specimen during transfer has been evaluated and was found to be a fail-safe procedure. Shielding the specimen with solidified coolant is proposed as an alternative or additional protection. The protective layer (ethane, Freon 22) can be evaporated in the high vacuum of the microscope. The evaporating coolant will carry away water films deposited on top. The temperature of coolant evaporation is low enough to prevent possible devitrification of water in the specimen itself.

Freezing↗

Vapor fixation for immunocytochemistry and X-ray microanalysis on cryoultramicrotome sections.

Several organic and inorganic vapor fixatives have been tested for their ability to stabilize the ultrastructure of freeze-dried thin cryosections. The vapors from osmium tetroxide and dry formaldehyde gave a good preservation of the ultrastructure. Fixation in formaldehyde vapor preserved the immunoreactivity of alpha-amylase in exocrine pancreas, as was demonstrated with an indirect labeling technique using anti-alpha-amylase and protein A-gold. A major advantage of the use of vapor fixation is that cryosections from a specimen of fresh-frozen tissue can be used for immunocytochemistry as well as for X-ray microanalysis, as was demonstrated for the exocrine pancreas. This opens the possibility of localizing atomic species (X-ray microanalysis) and molecular species (immunocytochemistry) at the subcellular level on thin cryosections from the same tissue block.

Animals↗

Surface defects on thin cryosections.

The electron microscopic observation of thin cryosections is frequently impaired by the occurrence of surface defects. To investigate the possible causes of these surface defects the structure of cryosections ( CTEM ) from frozen biological material was correlated with the structure of the block-face (SEM) from which the sections were obtained. Both sections and block-face showed steps with a periodicity larger than 0.5 micron. Upon dry sectioning of hard plastic comparable features were observed in the section ( CTEM /SEM) and block-face (SEM). Thin cryosections cut below 143 K were found to be smooth apart from defects introduced by imperfections of the knife. In addition to "long" wave length distortions, a periodical distortion smaller than 120 nm can be observed in cryosections from biological material. At a given temperature the frequency is related to the sectioning speed. At all sectioning temperatures studied, distortions of this high frequency/short wave length type have been observed although they were less conspicuous in thinner sections. The surface defects observed in cryosections from biological material resemble the defects found after metal cutting and chip-formation. Shear forces seem to be the main causes for the observed periodic deformations on both cryosections as well as on sections from metals and plastics. This may imply that material is collected and periodically shedded from a dead zone around the knife edge. In metal cutting such a dead zone can have the form of a built-up-edge on top of the knife or as a small overhang in front of the knife edge.

Animals↗

Concerning the nature of the cryosectioning process.

Intentional melting of frozen-thin-sections induces ultrastructural alterations. Cross sections through frozen dried and embedded cryosections revealed that even at the surface of such a section no melting artefacts are visible. One surface of the cryosection (obtained at 168 K) has a saw-teeth appearance whereas the other surface is rather smooth. The rate of freeze-drying in the cryochamber of the microtome was estimated to be in order 3.3 nm/min at 183 K and 22.5 nm/min at 193 K for sections, about 120 nm thick, of rat kidney frozen in freon 22 without any chemical fixation of cryoprotection. Although freeze-drying will normally not interfere with the cryo-sectioning process itself, it is a process which cannot be neglected during handling of sections. The available evidence indicated that frozen-thin-sections represent the frozen tissue with respect to the ultrastructure an probably also with respect to the chemical composition.

Animals↗

Ice crystal damage in frozen thin sections: freezing effects and their restoration.

Thin sections of unfixed kidney, fast frozen without cryoprotectants, were fixed in osmium tetroxide vapour directly after freeze drying or after 30 min in a moist atmosphere. Dry sections fixed in vapour showed ice crystal damage characteristic for the freezing procedure. This was demonstrated with freeze fracture replicas from the same preparation. Ice crystal holes were obscured in serial sections which were freeze dried and allowed to rehydrate in a moist atmosphere. The same ultrastructural appearance was observed in frozen sections brought to room temperature immediately after cutting. Frozen thin sections from unfixed tissue, if freeze dried, are very sensitive to atmospheric conditions and need some form of stabilization (e.g. osmium vapour fixation, sealing with an evaporated carbon film) before electron microscope images can be interpreted as representative for the frozen state. Restoration of ice crystal damage can occur by melting frozen sections or by rehydration of freeze dried frozen sections. Restoration phenomena will impair studies aimed at the localization of diffusible substances by autoradiography or X-ray microanalysis.

Animals↗

Freezing of tissue-limits for the autoradiographic localization of diffusible substances.

Frozen thin sections and sections from freeze-dried and embedded tissue are used for the autoradiographic localization of diffusible substances at the electron microscope level. The presence of ice crystals in such sections may limit the autoradiographic resolution. Ice crystals are formed during freezing and may grow during subsequent processing of tissue. The contribution of ice crystal growth to the final image was estimated by measuring the distribution of the ice crystal sizes in freeze-etch replicas and in sections from freeze-dried and embedded tissues. A surface layer (10-15 mu) without visible ice crystals was present in both preparations. Beneath this surface layer the diameter of ice crystals increased towards the interior with the same relationship between crystal size and distance from the surface in the freeze-etch preparation as in the freeze-dry preparation. Ice crystal growth occurring during a much longer time during freeze-drying compared to freeze-etching does not significantly contribute to the final image in the electron microscope. The formation of ice crystals during freezing determines to a large extent the image (and therefore the autoradiographic resolution) of freeze-dry preparations and this probably holds also for thin cryosections of which examples are given.