Field-flood requirements for emission computed tomography with an Anger camera.

Emission computed tomography with a rotating camera places stringent requirements on camera uniformity and the stability of camera response. In terms of clinical tomographic imaging, we have studied the statistical accuracy required for camera flood correction, the requirements for flood accuracy, the utility and validity of flood and data image smoothing to reduce random noise effects, and the magnitude and effect of camera variations as a function of angular position, energy window, and tuning. Uniformity of the corrected flood response must be held to better than 1% to eliminate image artifacts that are apparent in a million-count image of a liver slice. This requires calibration with an accurate, well-mixed flood source. Both random fluctuations and variations in camera response with rotation must be kept below 1%. To meet the statistical limit, one requires at least 30 million counts for the flood-correction image. Smoothing the flood image alone introduces unacceptable image artifacts. Smoothing both the flood image and data, however, appears to be a good approach toward reducing noise effects. Careful camera tuning and magnetic shield design provide camera stability suitable for present clinical applications.

Evaluation Studies as Topic↗

Development of a tomographic myelin scan.

The principle that myelin can be imaged noninvasively using the emission tomographic distribution of a lipophilic radioactive tracer was investigated. Properties of agents suitable for noninvasive myelin scanning are discussed with specific reference to blood-brain barrier permeability, metabolism, and tracer lipophilicity. The brain distributions of inert tracers are correlated with their partitioning between octanol and saline. A test probe, iodobenzene, was labeled with iodine 125 for preliminary invasive studies in the rabbit. The equilibrium brain distribution, determined either autoradiographically or by regional dissection, corresponded closely to that of myelin. 123I-labeled iodobenzene, a gamma-emitting analog, was then administered to a monkey, and tomographic reconstruction revealed a pattern of brain uptake corresponding to white matter.

Animals↗

Techniques for precise recording of gray-scale images from computerized scintigraphic displays.

Accurate, reproducible recording of gray-scale images from a computer requires careful calibration and control of the factors that affect photographic exposure. These include exposure time, CRT brightness and contrast, film type, and photographic processing. A method is described for calibrating the imaging system; it accounts for nonlinear CRT phosphor and film response and permits the recording of any desired gray scale. The key to this technique is a graphical method for correlating the measured film response with the desired gray scale in order to develop a translation table that will in turn produce the desired gray scale on film. The technique is applicable to any computerized nuclear medicine display system.

Data Display↗

Calculation of viable and infarcted myocardial mass from thallium-201 tomograms.

The feasibility of determining the mass of both viable and infarcted myocardium from tomographic images of thallium-201 distribution in the heart was studied in two normal dogs and ten dogs with acute infarction. Twenty-four hours after occlusion, thallium-201 was injected and 10 min later the hearts were removed and transaxial emission computed tomograms were obtained. Using the computer, an operator defined the epi- and endocardial surfaces of the left ventricle and the area of infarction in each tomogram. The computer then calculated values for total left-ventricular mass (TLVM) infarcted mass (IM) and the percentage of the left ventricle infarcted (% LVI). The calculated values were compared with measured weights, and good correlation was found between them: for TLVM, r = 0.87; for IM, r = 0.90; and for %LVI, r = 0.87. Good interobserver and intra-observer correlations were also found. Thallium-201 emission computed tomography offers a potential means to measure both myocardial mass and acute myocardial injury.

Animals↗

Oblique-angle tomography: a restructuring algorithm for transaxial tomographic data.

A set of contiguous transaxial tomographic sections obtained with a rotating-camera tomograph represents the full three-dimensional distribution of activity within a volume of the body. Tomographic sections in planes other than the origianl transverse plane can be produced from these data merely by resorting the data appropriately. The paper presents a simple and efficient algorithm for producing tomograms of the heart oriented either at right angles to the long axis of the left ventricle, or parallel to it. Tomograms in these orientations have specific advantages for imaging the heart and avoid some of the limitations seen in comparable tomograms obtained by the seven-pinhole technique.

Heart↗

Thallium-201 myocardial scintigraphy: a critical comparison of seven-pinhole tomography and conventional planar imaging.

Seven-pinhole tomographic and planar thallium-201 imaging was performed on 63 consecutive patients to assess the clinical value of these techniques. Significant coronary artery disease (stenosis greater than or equal to 70%) was present in 52 patients. Comparing the seven-pinhole results with those of the planar, the findings for sensitivity, specificity, and inter- and intraobserver agreement were, respectively, 94% against 75% (p less than 0.005), 91% against 91%, 86% against 79%, and 97% against 92%. In 25 patients in this group with a prior myocardial infarction, sensitivity was 100% for tomographic imaging and 92% for planar. In 27 patients without prior myocardial infarction, by contrast, sensitivity for tomographic imaging was 89% and for planar imaging 59% (p less than 0.01). Thus we conclude that both tomographic and planar imaging are highly sensitive for the detection of significant coronary artery disease, but tomographic imaging is significantly more sensitive in patients without prior myocardial infarction.

Coronary Disease↗

Tomographic thyroid scintigraphy: comparison with standard pinhole imaging: concise communication.

Coded-aperture imaging (CAI) and multiple-view pinhole imaging (PI) of the thyroid were compared in a prospective study in 136 consecutive patients. Following 10 mCi of pertechnetate, 200K-count pinhole images were obtained in the anterior, RAO, and LAO projections, and CAI data were obtained in the anterior position. Four coronal tomographic sections were reconstructed by computer. Five observers read the studies separately, and ROC curves were constructed. Based on 109 pairs of studies, the ROC curves revealed similar performance for all observers for both techniques. When four observers compared the studies subjectively they rated the CAI more useful in 36% of cases, the PI in 6%, and the two equal in 58%. The advantages offered by the tomograms included improved contrast, accurate size representation of the gland at all depths, freedom frm pinhole-type distortion, and faster data acquisition. The major disadvantage to tomography was the 2-hr computer-processing time required. It this can be reduced, CAI offers sufficient advantages over conventional pinhole imaging to warrant its routine use.

Adult↗

Imaging the primate adrenal medulla with [123I] and [131I] meta-iodobenzylguanidine: concise communication.

An evaluation of radioiodinated meta-iodobenzylguanidine (m-IBG) as an adrenomedullary imaging agent is reported in 15 rhesus monkeys. Scintiscans of the monkey adrenal medulla have been obtained with [123I]- and [m-131I]IBG at 2-6 days after injection. The imaging superiority of m-IBG over its positional isomer, para-iodobenzylguanidine (p-IBG), is documented in both dogs and monkeys. Administration of reserpine, a depletor of catecholamine stores, markedly lowers the [m-131I]-IBG content of the dog adrenal medulla, but the adrenergic blocking agents phenoxybenzamine and propranolol have no effect. Subcellular fractionation of the dog's adrenal medullae reveals that m-IBG is sequestered mainly in the chromaffin storage granules. The results of this study suggest that radioiodinated m-IBG, previously reported to image the primate myocardium, also merits evaluation as a clinical radiopharmaceutical for the adrenal medulla.

3-Iodobenzylguanidine↗

Myocardial imaging with a radioiodinated norepinephrine storage analog.

Meta-iodobenzylguanidine (M-IBG), an iodinated aromatic analog of the hypotensive drug quanethidine, localizes in the heart of the rat, dog, and rhesus monkey. A comparative study of tissue distribution in the dog has been performed with five myocardiophilic agents: thallium-201, I-125 16-iodohexadecanoic acid, H-3 norepinephrine, C-14 guanethidine and I-125 M-IBG. The last two compounds give heart concentrations and heart-to-blood concentration ratios similar to those of thallium-201. Planar and tomographic images of the hearts of the dog and rhesus monkey were obtained using I-131 or I-123 labeled M-IBG. Blocking studies with reserpine suggest that a major component of myocardial retention of M-IBG is sequestration within the norephinephrine storage vesicles of the adrenergic nerves. The localization of M-IBG in other organs with rich sympathetic innervation and the relative insensitivity of myocardial uptake to a wide range of loading doses lend additional support for a neuronal mode of retention.

3-Iodobenzylguanidine↗

Coded-aperture imaging of the heart.

Coded-aperture imaging of the heart combines the advantages of tomography with good sensitivity, high resolution, and accurate size scaling. Since the images are multiplexed, the method may be adapted to small, portable cameras for bed-side use without sacrificing image resolution. A new coded aperture designed especially for cardiac imaging has been constructed and tested. This aperture incorporates significant improvements over previous designs. Longitudinal tomograms are calculated at 1-cm intervals using a modified ART algorithm. Experimental lateral resulution at 140 keV with a portable scintillation camera is 3.8 mm FWHM at 4 cm, and 7.8 mm FWHM at 12 cm. Dpth resolution determined from a sloping line source is 1.1 cm FWHM at 4 cm, and 2.9 cm at 12 cm. The calculated point-source sensitivities in air at 4 cm and 12 cm, respectively, are 20 and 8 cps/microCi. Images of good diagnostic quality have been obtained in phantoms and in a dog model of acute myocardial infarction, using thallium-201, technetium-99m pyrophosphate, and gated ventricular blood-pool imaging with Tc-labeled red blood cells. Preliminary studies in humans confirm the good results in animals.

Animals↗

Application of ART to time-coded emission tomography.

Devices for single-photon emission tomography currently take projections either in a plane over a full angular range (0--360 degrees) or in a volume with a limited angular range. The planar, pseudo-random, time-coded aperture, in conjunction with an Anger camera, is a device of the limited angular range type. It employs multiple pinholes whose transmission varies as a function of time. Previously, image reconstruction was accomplished by simple back-projection of coefficients obtained by time-correlating pinhole transmission with detector-element count rate, resulting in a low-contrast image. Using the Algebraic Reconstruction Technique (ART) a method is introduced for division of the correlation coefficients into subsets allowing the three-dimensional reconstruction to be accomplished on a minicomputer. Results from simulations and experimental phantom data show that ART improves depth resolution compared to back-projection, that under-relaxation produces better images in the case of noisy data, and that the division of the correlation coefficients into subsets has no effect on quality. The images depict the expected resolution degradation in the direction normal to the detector plane due to the limited angular range of projections but yield quantitative results whose relative values are good, even though attenuation is neglected.

Mathematics↗

Exercise radionuclide ventriculography: practical considerations and sensitivity of coronary artery disease detection.

Eighty-nine patients were evaluated for coronary artery disease (CAD) with exercise radionuclide ventriculography (ERV) and contrast coronary angiography. In 70 patients with documented lesions the ERV was abnormal in 65 for a sensitivity of 93%. In patients with normal coronary arteries, the ERV was abnormal in none for a specificity of 100%. Sensitivity of ERV for detecting CAD was affected by the level of exercise achieved. In patients with documented CAD who achieved adequate exercise (i.e., pressure rate product (PRP) greater than 250 or the development of angina or ST segment depression during exercise), the sensitivity was 98% (56 of 57 patients). In those with documented CAD who failed to achieve adequate exercise, the sensitivity was 69% (9 of 13 patients).

Angiography↗

Thyroid scintigraphy with time-coded aperture.

Coded aperture imaging (CAI) and multiple-view pinhole imaging (MVPI) of the thyroid were compared in 19 patients to determine whether CAI's theoretical advantages of high resolution, high efficiency, freedom from distortion, accurate size representation, and tomographic presentation could be realized in the clinical setting, and to determine whether CAI offers any advantage over conventional MVPI. The coded aperture images were judged better than the pinhole images in five cases, equal in 13 cases, and worse in one case. The major problem with CAI was the long reconstruction time. Further development and an extended clinical trial appear warranted.

Humans↗

Myocardial imaging using emission computed tomography.

Single-photon emission computed tomography (ECT) was evaluated during myocardial studies in dogs. Acute anterior and posterior infarcts were imaged following injection of 99mTc-pyrophosphate or 201Tl. In most cases, tomographic delineation of infarct location and extent correlated with tissue section. The 99mTc images were far superior to the 201Tl images. ECT improves delineation of tracer within the myocardium.

Animals↗

Myocardial infarct quantification in the dog by single photon emission computed tomography.

Radionuclide techniques for sizing acute myocardial infarction have been hampered by the intrinsic limitations of the scintillation camera. Emission computed tomography can overcome these limitations. Single photon emission computed tomograms of the distribution of technetium-99m pyrophosphate in acute anterior and posterior infarcts were obtained in 16 dogs after death. Tomograms were also obtained in 10 dogs during life without gating. The size of the infarcts was determined by staining gross sections of the heart with nitro blue tetrazolium, dissecting out the infarcted tissue and weighing it. Infarct sizes were determined from the tomographic images and compared with the measured infarct sizes. Good images showing the location and three-dimensional extent of the infarcts were obtained in all dogs. The measured and calculated infarct sizes correlated well (r = 0.85). Comparison of the calculated sizes in the living (non-gated) and dead ("physiologically" gated) animals showed reasonable agreement (r = 0.87). Single photon emission computed tomography is a feasible and useful technique for localizing and sizing acute myocardial infarctions.

Animals↗

Clinical comparison of cardiac blood pool visualization with technetium-99m red blood cells labeled in vivo and with technetium-99m human serum albumin.

Technetium-99m red blood cells (Tc-RBC) labeled by an in vivo technique were compared with two preparations of Tc-99m human serum albumin (HSA) for cardiac blood-pool imaging. Relative distribution of the tracers was analyzed on end-diastolic frames of gated blood-pool studies and on whole-body (head to mid-thigh) anterior pinhole images. The Tc-RBC demonstrated greater relative percentage localization in the cardiac blood pool, higher target-to-background ratios in the left ventricle, and less liver concentration. For cardiac blood-pool imaging, Tc-RBC labeled by the in vivo approach appears to be superior to the two Tc-HSA preparations studied.

Cardiac Volume↗

The Humongotron--a scintillation-camera transaxial tomograph.

An emission transaxial tomographic system using a scintillation camera as the detector is described. The unit allows accurate positioning of a scintillation camera's detector at any angle around a patient in order to obtain the multiple projection images needed for transaxial tomography, and it is capable of imaging any area of the body. The camera can also be used for all types of conventional imaging procedures. Image processing is performed by a small on-line computer. A convolution algorithm and a mathematical technique for approximate absorption correction are used to obtain high-resolution and high-contrast images with good quantitative accuracy. The operation of the system is described and representative phantom and patient studies are presented to illustrate the capabilities of the system.

Brain Neoplasms↗

Digital tomographic imaging with time-modulated pseudorandom coded aperture and Anger camera.

The properties of a time-modulated pseudorandom coded aperture with digital reconstruction are compared with those of conventional collimators used in gamma-ray imaging. The theory of this coded aperture is given and the signal-to-noise ratio in an element of the reconstructed image is shown to depend on the entire source distribution. Experimental results with a preliminary 4 X 4-cm pseudorandom coded aperture and an Anger camera are presented. These results include phantom and human thyroid images and tomographic images of a rat bone scan. The experimental realization of the theoretical advantages of the time-modulated coded aperture gives reason for continuing the clinical implementation and further development of the method.

Radionuclide Imaging↗