Search PubMed⌕ Search

Biomedical subjects

W Kalk

Publications and source records attributed to W Kalk.

At least 19 recordsLinked to original sources

Bond strength of resin composite to differently conditioned amalgam.

Bulk fracture of teeth, where a part of the amalgam restoration and/or the cusp is fractured, is a common clinical problem. The aim of this study was to evaluate the effect of different surface conditioning methods on the shear bond strength of a hybrid resin composite to fresh amalgam. Amalgams (N=84) were condensed into acrylic and randomly assigned to one of the following treatments (N=6): (1) Alloy primer + opaquer, (2) Air-particle abrasion (50 micro m Al(2)O(3)) + alloy primer + opaquer, (3) Silica coating (30 micro m SiO(x)) + silanization + opaquer, (4) Opaquer + pre-impregnated continuous bidirectional E-glass fibre sheets, (5) Silica coating + silanization + fibre sheets, (6) Silica coating + silanization + opaquer + fibre sheet application. Non-conditioned amalgam surfaces were considered as control group (7). The mean surface roughness depth (R(Z)) was measured from the control group and air-abraded amalgam surfaces. The resin composite was bonded to the conditioned amalgam specimens using polyethylene molds. All specimens were tested under dry and thermocycled (6.000, 5-55 degrees C, 30 s) conditions. The shear bond strength of resin composite to amalgam substrates was measured in a universal testing machine (1 mm/min). Surface roughness values for the non-conditioned control group (R(Z) approximately 0.14 micro m) and for air-particle abraded surfaces with either Al(2)O(3) or SiO(x) (R(Z) approximately 0.19 micro m and R(Z) approximately 0.16 micro m, respectively) did not show significant differences (p=0.23) (One-way ANOVA). In dry conditions, silica coating and silanization followed by fibre sheet application exhibited significantly higher results (14.8+/-5.6 MPa) than those of the groups conditioned with alloy primer (2.2+/-0.7 MPa) (p<0.001), air-particle abrasion+alloy primer (4.4+/-2.0 MPa, p<0.001), silica coating+silanization alone (6.2+/-0.8 MPa, p=0.009) or non-conditioned group (1.4+/-0.6, p<0.001). Silica coating and silanization followed by additional fibre sheets with opaquer application (23.6+/-6.9 MPa) increased the bond strength significantly compared to those of other groups (group 5 vs group 6, p=0.007; other groups vs group 6, p<0.001). Thermocycling decreased the bond strengths significantly for all of the conditioning methods tested (for group 1, p<0.001; for group 2, p=0.013; for group 3, p=0.002; for group 4, p=0.026; for group 5, p=0.002; for group 6, p<0.001 and for group 7, p<0.001).

Air Abrasion, Dental↗

Effect of three surface conditioning methods to improve bond strength of particulate filler resin composites.

The use of resin-based composite materials in operative dentistry is increasing, including applications in stress-bearing areas. However, composite restorations, in common with all restorations, suffer from deterioration and degradation in clinical service. Durable repair alternatives by layering a new composite onto such failed composite restorations, will eliminate unnecessary loss of tooth tissue and repeated insults to the pulp. The objective of this study was to evaluate the effect of three surface conditioning methods on the repair bond strength of a particulate filler resin-composite (PFC) to 5 PFC substrates. The specimens were randomly assigned to one of the following surface conditioning methods: (1) Hydrofluoric (HF) acid gel (9.5%) etching, (2) Air-borne particle abrasion (50 microm Al2O3), (3) Silica coating (30 microm SiOx, CoJet-Sand). After each conditioning method, a silane coupling agent was applied. Adhesive resin was then applied in a thin layer and light polymerized. The low-viscosity diacrylate resin composite was bonded to the conditioned substrates in polyethylene molds. All specimens were tested in dry and thermocycled (6.000, 5-55 degrees C, 30 s) conditions. One-way ANOVA showed significant influence of the surface conditioning methods (p < 0.001), and the PFC types (p < 0.0001) on the shear bond strength values. Significant differences were observed in bond strength values between the acid etched specimens (5.7-14.3 MPa) and those treated with either air-borne particle abrasion (13.0-22.5 MPa) or silica coating (25.5-41.8 MPa) in dry conditions (ANOVA, p < 0.001). After thermocycling, the silica coating process resulted in the highest bond values in all material groups (17.2-30.3 MPa).

Acid Etching, Dental↗

[Dissertations 25 years after date 3. Dentures finally happy ventures!].

Twenty-five years ago the PhD-thesis 'Dentures happy ventures?' of Kalk described the problems and reasons for (dis)satisfaction with complete dentures. In this article an overview is given of different PhD-theses in The Netherlands which have further elaborated and analyzed the problems of the compromised edentulous patient. More insight was gained in the aetiology and the background of edentulism and dissatisfaction with complete dentures. Nowadays, it is known which treatment strategies can retard bone loss and it is also known that pre-prosthetic surgery is less effective in resolving severe alveolar bone loss than expected. In The Netherlands, randomized clinical trials have shown that a mandibular overdenture retained by two or four implants is very effective in compromised edentulous patients.

Alveolar Bone Loss↗

Pain and instability during biting with mandibular implant-retained overdentures.

We tested in a randomized controlled clinical trial the effect of pain and instability of dentures on bite force with different degrees of mucosal support. The trial involved 3 groups who had received: 1) a new conventional denture (CD-group), 2) an implant-mucosa-borne overdenture on 2 IMZ implants (IMZ-group) or 3) a mainly implant-borne overdenture retained by a transmandibular implant (TMI-group). Fifty-three women and 15 men, mean age 59 years, participated in this study. Bite force measurements were made unilaterally with a transducer and bilaterally with a bite fork. After the measurements, subjects were asked whether or not biting had caused pain or tilting of one of the dentures. Significantly more complete-denture wearers reported pain. They reported more frequent pain in the mandible than in the maxilla (P < 0.001), whereas implant-groups seemed to experience more often pain in the maxilla. On the transducer, maxillary dentures of the CD-group tilted less (P < 0.01) and mandibular dentures more (P < 0.05) compared to the implant-groups. With the bite fork, tilting occurred more often in the incisal-cuspid area than in the molar region (P < 0.001). No effect of pain and tilting was observed on maximum bite force. It appears that oral implants used to stabilize mandibular dentures permit subjects to exert higher bite forces and reduce the pain as otherwise felt in the mandible during maximum biting. Due to this stabilization, pain and instability of the maxillary denture can become the limiting factor for a further increase in bite force.

Adult↗

Changes in the edentulous maxilla in persons wearing implant-retained mandibular overdentures.

STATEMENT OF PROBLEM: It has been suggested that risk for severe resorption in the anterior maxilla is increased in persons wearing mandibular implant-retained overdentures. However, little information is available about the changes in the edentulous maxilla after mandibular implant treatment. PURPOSE: This study determined the possible changes in the width of the maxillary residual ridge 6 years after receiving mandibular implant-supported or implant-mucosa-supported overdentures and evaluated the association between the anatomic changes and subjective complaints with maxillary complete dentures. METHODS AND MATERIAL: The subjects for this study (n = 55), enrolled among the participants of a prospective clinical trial, were randomly assigned into 3 groups treated with: (a) implant-supported overdentures on a transmandibular implant system (n = 21); (b) implant-mucosa-supported overdentures on 2 IMZ implants (n = 20); or (c) conventional complete dentures (n = 14). A lingual contact occlusion concept with anterior open bite was used for tooth arrangement in all subjects. Diagnostic casts were made at baseline, and again at the 6-year follow-up. Most prominent points perpendicular to the crest of residual ridge were located in the incisor, canine, and premolar regions, after which the width of the ridge was recorded at these points with a Boley gage. Subjects' opinions on their dentures were evaluated with a questionnaire. RESULTS: Significant reduction in the width of the ridge was found in all measurement areas (mean difference = 0.4 to 0.6 mm; P <.0001). However, changes were small and not associated with the type of prosthetic restoration in the mandible. In subjects with implant-mucosa-supported overdentures, complaint of loose maxillary denture correlated with the decrement of residual ridge width. CONCLUSION: The width of residual ridge decreases with time, despite the type of mandibular prosthetic restoration.

Aged↗

Biting and chewing in overdentures, full dentures, and natural dentitions.

It has been suggested that the provision of dental implants can improve the oral function of subjects with severely resorbed mandibles, possibly restoring function to the level experienced by satisfied wearers of conventional complete dentures. Nevertheless, a quantitative comparison has never been made and can be drawn from the literature only with difficulty, since studies differ greatly in methodology. To make such a comparison, we measured bite force and chewing efficiency by using identical methods in subjects with overdentures, complete full dentures, and natural dentitions. Our results indicated that bite forces achieved with overdentures on dental implants were between those achieved with artificial and natural dentitions. Chewing efficiency was significantly greater than that of subjects with full dentures (low mandible), but was still lower than that of subjects with full dentures (high mandible) and overdentures on bare roots. Differences in the height of the mandible revealed significant differences in chewing efficiency between the two full-denture groups. Furthermore, subjects with a shortened dental arch exerted bite forces similar to those of subjects with a complete-natural dentition, but their chewing efficiency was limited due to the reduced occlusal area. For all groups combined, a significant correlation was found between maximum bite force and chewing efficiency. Nearly half of the variation in chewing efficiency was explained by bite force alone.

Adult↗

Clinical and radiological results of patients treated with three treatment modalities for overdentures on implants of the ITI Dental Implant System. A randomized controlled clinical trial.

In a randomized controlled clinical trial carried out at the Ignatius teaching hospital in Breda, The Netherlands, 110 edentulous patients with severe mandibular bone loss were treated with implants of the ITI Dental Implant System using 3 different treatment strategies: a mandibular overdenture supported by either 2 implants with ball attachments, 2 implants with an interconnecting bar, or by 4 interconnected implants. In this study, results of clinical and radiographic parameters were evaluated and compared over a period of 19 months after implant placement. A total of 283 ITI Dental Implants were placed. Six implants (2%) were lost during the osseointegration period. No further implant losses occurred after that. At the 19 month evaluation mean values and standard deviations for bleeding index were 0.51 +/- 0.5 (bleeding incidence = 70%) and for plaque index they were 0.46 +/- 0.5 (plaque incidence = 45%). The mean values and standard deviations for probing depth and loss of attachment were 2.7 +/- 1.1 mm and 0.26 +/- 0.6 mm respectively. The radiographic evaluation showed a mean bone loss of 1.5 mm +/- 0.26 after 19 months for all the implants. In cases with 4 interconnected implants there was significantly more bone loss around the central 2 implants (2.1 +/- 0.31 mm) in comparison with the lateral 2 (1.4 +/- 0.25 mm). No significant correlations were found between plaque and bleeding indices and bone loss.

Alveolar Bone Loss↗

Masticatory performance and chewing experience with implant-retained mandibular overdentures.

The relationship between masticatory performance and chewing experience has not yet been explored for patients with implant-retained overdentures. Although many relationships have been found between parameters of objective and subjective oral function, the structure of these relationships remain unclear. Therefore, we studied in a randomized clinical trial the relationship between the comminution of an artificial test food, i.e. masticatory performance, and the subjective chewing experience. The trial involved a comparison between two groups receiving implant treatment and one group receiving conventional complete dentures (CD). The implant treatment involved either a mainly implant-supported mandibular overdenture on a transmandibular implant (TMI) or an implant-tissue-supported mandibular overdenture on two IMZ implants (IMZ). Masticatory performance as well as chewing experience were substantially better for the implant-retained overdentures compared with the complete denture group. No significant differences emerged between the TMI and the IMZ group. A multiple regression analysis did not provide any comprehensibility in the relationship between masticatory performance and the variables of chewing experience. In the linear structural relation analysis (LISREL) no direct relationship was found between masticatory performance and functional complaints mandibular denture. The results show that an improvement in masticatory performance does not imply the same improvement in chewing experience and vice versa.

Adult↗

Bite forces with mandibular implant-retained overdentures.

Sensitivity or pain of the mucoperiosteum covering the mandibular edentulous ridge is often thought to limit bite forces in complete-denture wearers. Therefore, bite forces with mandibular implant-retained overdentures may depend on the degree of implant support. This study analyzed the effects of different degrees of support for the mandibular denture on bite forces measured four years after denture treatment as part of a randomized controlled clinical trial. All subjects had received new maxillary dentures and (1) mainly implant-borne overdentures on a transmandibular implant (TMI), (2) mucosa-borne overdentures on two cylindric permucosal IMZ implants, or (3) new conventional dentures in the mandible. Fifty-three women and 15 men (mean age, 59.1 yrs; range, 41 to 77) participated in this trial. Both unilateral and bilateral bite forces were recorded at different positions with a miniature strain gauge transducer and a mechanical bite fork, respectively. The subjects were asked to bite at three force levels. Results indicated that women had significantly lower maximum bite forces than men. Persons with mandibular implant-retained overdentures had significantly higher unilateral and bilateral maximum bite forces than complete-denture wearers. However, bite forces did not differ between the mainly implant-borne (TMI) and mucosa-implant-borne (IMZ) implant systems. Therefore, it appears that differences in support for the mandibular overdenture by dental implants are not reflected in bite force capabilities.

Adult↗

[Comparison of dental implant systems for mandibular overdentures].

OBJECTIVE: To compare three implant systems in patients with severely resorbed mandibles 1 year after insertion of the mandibular denture. DESIGN: A prospective multicenter randomized clinical trial. SETTING: Centers at University of Nijmegen and Groningen. METHODS: Three different implant systems were used: the transmandibular implant, the IMZ and the Brånemark system. Treatment was assigned to 88 patients according to a balanced allocation method. Evaluation included clinical and radiographic parameters. A Clinical Implant Performance scale (CIP) was constructed based on all conceivable complications of the different implant systems. RESULTS: During the healing period 1 IMZ- and 1 BRA-implant were lost. One TMI was removed after functional loading. The results of the clinical and radiographic parameters and the CIP-scale showed no significant differences between the three implant systems. CONCLUSION: Taking the one year evaluation into account the three systems used did not differ in clinical and radiographic performance.

Dental Implantation, Endosseous↗

[Overdenture prostheses on implants versus complete dentures].

OBJECTIVE: To establish the treatment outcome of implant retained overdentures (IRD) versus complete dentures (CD) in which the outcome assessment focuses on the patient's subjective evaluation ('denture-satisfaction and chewing ability'). DESIGN: A multicenter randomized clinical trial (prospective). SETTING: The department of Oral Function and Prosthetic Dentistry of the University of Nijmegen, the department of Oral and Maxillofacial Surgery of the University Hospital Nijmegen and the department of Oral and Maxillofacial Surgery and Maxillofacial Prosthodontics of the University Hospital Groningen. METHODS: In this study 151 patients with severely resorbed mandibles participated, treatment had been assigned according to a balanced allocation method. Denture satisfaction and chewing ability were assessed using questionnaires before and 1 year after treatment. RESULTS: Before treatment all patients were dissatisfied with their mandibular denture and they could hardly chew tough or had food. One year after treatment the IRD-group was satisfied with their mandibular denture, whereas only one third of the CD-group was satisfied. With respect to the chewing ability the IRO-group scored significantly better than the CD-group (p < or = 0.0001). CONCLUSION: For patients with a severely resorbed mandible, overdentures retained by dental implants appear to provide a more satisfactory solution to their denture-related problems.

Alveolar Bone Loss↗

The effect of Ca-P plasma-sprayed coatings on the initial bone healing of oral implants: an experimental study in the goat.

The response of bone of low density to uncoated, fluorapatite (FA), hydroxyapatite (HA), and hydroxyapatite heat treated (HAHT) plasma-sprayed coated implants was investigated 3 and 6 months after installation. Forty-eight threaded implants of commercially pure titanium were inserted into the maxilla of twelve goats according to a split-plot design. One goat died shortly after installation of the implants, five goats were sacrificed 3 months after installation, and the other six goats 6 months after installation. Histological evaluation revealed no difference in bone reaction between the 3- and 6-month implantation periods. In addition, probably due to the wide inter- and intra-animal variability, no significant difference between the 3- and the 6-month periods could be observed in the histomorphometrical measurements performed. Further, no significant differences were found in bone reaction among the various implant materials. Finally, qualitatively it appeared that all coatings showed reduction in coating thickness and that such reductions were most pronounced for the HA coatings.

Animals↗

A histological and histomorphometrical evaluation of the application of screw-designed calciumphosphate (Ca-P)-coated implants in the cancellous maxillary bone of the goat.

Various studies already have shown that the occurrence of oral implant failure is higher in the maxilla than in the mandible. To learn whether Ca-P coatings can improve the success rate of oral implants in the maxilla, three different plasma-sprayed, Ca-P-coated, self-tapping Brånemark implants were inserted in the trabecular bone of the maxilla. Before the insertion of the implants, the two first upper premolars of 16 goats were bilaterally extracted. Four months later, each animal received four types of implants: three different Ca-P-coated types and one uncoated. After an endosseous period of 6 months, the implants were provided with permucosal abutments. Four months later the animals were killed. At the end of the experiment, it appeared that 10 of the 16 installed noncoated implants had failed while of the 48 Ca-P-coated implants, only 6 had failed. All successful implants were retrieved and prepared for histomorphometrical evaluation of the bone and gingiva response. The Ca-P-coated implants showed a significantly greater percentage of bone in contact with the implant surface compared with the uncoated implants. The length of the epithelium was not significantly different for the coated compared to the uncoated implants, but the connective tissue was significantly thicker for the noncoated implants than for the Ca-P-coated implants. Also, measurements revealed that all coatings showed reduction in thickness. On the basis of these findings, we concluded that the application of Ca-P coatings (1) improves the bone-implant reaction, although all coatings reduced in thickness, and (2) is of benefit during the healing period in less mineralized trabecular bone.

Animals↗

Professional hygiene care, adjustments and complications of mandibular implant-retained overdentures: a three-year retrospective study.

PURPOSE: This report presents a retrospective evaluation of postinsertion care required by 104 edentulous patients with advanced mandibular bone loss. MATERIAL AND METHODS: The patients were treated with new maxillary dentures and mandibular overdentures retained by two implants with a single bar-clip attachment. Distinction was made between professional hygiene care, adjustments, and treatment of complications. The follow-up period after insertion of dentures was 3 years for all patients. RESULTS: Approximately a third of the patients needed professional hygiene care. The need for adjustments declined during the years of function. Complications were encountered in approximately a third of the patients. The majority of these were not related to the implants, but to the superstructure and both the maxillary and mandibular dentures. CONCLUSIONS: Many edentulous patients with advanced mandibular bone loss who were treated with mandibular implant-retained overdentures need professional hygiene care, adjustments, and treatment of complications.

Bone Resorption↗

"Prosthetic condition" and patients' judgment of complete dentures.

PURPOSE: This study introduces the concept "prosthetic condition", which combines the quality of complete dentures and residual alveolar ridges. MATERIAL AND METHODS: A pilot study was performed to select quality criteria with an acceptable interobserver agreement. With these criteria, a clinical examination was performed to assess the quality of the existing complete dentures and the residual alveolar ridges of 397 complete denture wearers. During clinical examination, the interobserver agreement of the selected criteria was retested. The "prosthetic condition" was assessed by combining the scores for denture quality and quality of the residual alveolar ridges. Subsequently, participants' satisfaction with and complaints about their dentures were scored according to their answers to specific questions. RESULTS: Logistic regression analysis demonstrated that no variable of the "prosthetic condition" proved to explain the denture satisfaction. Some variables of the "prosthetic condition" had a significant but not relevant correlation with some denture complaints. CONCLUSIONS: More research is necessary to substantiate the concept "prosthetic condition" as an acceptable measure of professionally quality assessment of dentures and denture-bearing surfaces. However, in determining the treatment need of community-dwelling groups, this concept seems a more realistic measure than denture quality only.

Adult↗

Assessment of bone surrounding implants in goats: ex vivo measurements by dual X-ray absorptiometry.

The aim of the present study is to determine the possibility of measuring the bone mineral density (BMD) around implants by dual energy X-ray absorptiometry (DEXA). Therefore, the trabecular BMD was measured close to 127-600 microns and at a distance from various uncoated and Ca-P-coated implants inserted into the femoral condyle of goals. The implants were left in situ for 12 weeks. In addition, the bone-implant interface was evaluated histologically. For comparative reasons the BMD of non-implanted lateral and medial femoral condyles was also measured. The reproducibility of the measurements, expressed as a coefficient of variation, was found to be 0.44%. Moreover, the regions closest to the implants exhibited a higher BMD than all other regions, and the regions located in the medial condyle showed a higher BMD than the lateral condylar regions. Although the histological sections of the implants in the medial condyle demonstrated more bone contact with the coated than with the uncoated implants, a higher density was measured around the uncoated implants. The results regarding the non-implanted condyles indicated a higher density in the medial than in the lateral condyle. In view of these results, we conclude that BMD around dental implants depends on the location of the implant and that DEXA appears to be an excellent tool for analysing bone-implant reactions.

Absorptiometry, Photon↗