[Problems in everyday practice: ventricular extrasystoles].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to W Jung.
Explore the source record for details and available documents.
We have investigated the modulation of neuronal large conductance Ca2+-activated K+ channels by glutathione. Single channel recordings were made from cultured neonatal rat hippocampal neurons by using excised inside-out patch clamp method. Glutathione, a physiological sulfhydryl specific reducing reagent, increased channel activities in concentration dependent manner with half activation concentration of 710 microM. Conversely, oxidized form of glutathione inhibited channel activities with half inhibition concentration of 520 microM. Our results provide direct evidence that when neuronal large conductance Ca2+-activated K+ channels are exposed to reducing or oxidizing environments, channel activities are increased or decreased in opposite directions due to the redox modification. This may constitute an important regulatory mechanism of neuronal Ca2+-activated K+ channel activities.
BACKGROUND: The treatment of concomitant atrial tachyarrhythmias in patients with malignant ventricular tachyarrhythmias is a major challenge for new defibrillator devices. Atrial fibrillation is not only responsible for inappropriate ventricular therapies, but also reduced left ventricular performance, especially in patients with heart failure and severely depressed left ventricular function. Furthermore, it is a strong risk factor for the development of thromboembolism. NEW SYSTEM: A new dual-chamber implantable defibrillator is capable of tiered atrial therapies for both regular and irregular atrial tachyarrhythmias. In first investigations a high sensitivity and specificity could be shown as well as a promising therapy efficacy of atrial antitachycardia ramp and burst pacing for the treatment of atrial tachycardias. Atrial ramp pacing has shown to be successful for regular atrial tachyarrhythmias in up to 60 to 70% of all episodes. The results have supported a programming of a high first shock energy for treatment of atrial fibrillation. The incidence of atrial fibrillation in patients with a history of atrial fibrillation or without is much higher in the present investigated patient populations than expected. CONCLUSION: The more complicated and subtle new dual-chamber detection algorithm has proven to be safe and effective both for the detection of ventricular tachycardia but also in terms of an increase of specificity and a reduction of inappropriate ventricular therapies for atrial tachyarrhythmias.
Rosetting of CD4+ T cells around the neoplastic Hodgkin and Reed-Sternberg (H&RS) cells is a characteristic feature of Hodgkin's disease (HD). To answer the question whether this phenomenon is solely due to chemokine-mediated attraction of T cells or whether the rosetting T cells in addition recognize antigens presented by the H&RS cells, we examined the T cells adherent to H&RS cells. Cells from five cases of HD [four classic HD and one lymphocyte-predominant (LP) HD] were examined by single-cell analysis for the T-cell receptor (TCR) gamma gene. Between 5 and 17 rosettes containing one to ten rosetting lymphocytes and the corresponding H&RS cells were amplified in separate plastic tubes. Of the resulting 119 TCRgamma polymerase chain reaction (PCR) products, 87 were sequenced. While no evidence of a clonal expansion was obtained in the lymph nodes from four of five patients with classic HD, clonal TCRgamma sequences were found in the lymph node from the patient within LPHD in two independent experiments analyzing seven and ten different rosetting complexes, respectively. Of 13 products, 11 showed identical Vgamma9 sequences. Unrelated products were found in all other TCRgamma family subgroups in this case. Single H&RS cells picked as controls were negative for TCRgamma rearrangements. Our results demonstrate that clonal proliferations on a polyclonal background can occur among the T cells forming rosettes with Hodgkin cells and lend support to the view that Hodgkin cells may also function as cells presenting antigens to the adhering T cells.
The safety and feasibility of magnetic resonance imaging (MRI) in patients with cardiac pacemakers is an issue of gaining significance. The effect of MRI on patients' pacemaker systems has only been analyzed retrospectively in some case reports. Therefore, this study prospectively investigated if MRI causes irreversible changes in patients' pacemaker systems. The effect of MRI at 0.5 Tesla on sensing and stimulation thresholds, lead impedance and battery voltage, current, and impedance was estimated during 34 MRI examinations in 32 patients with implanted pacemakers. After measurements at baseline and with documentation of intrinsic rhythm and modification of the pacing mode, patients underwent MRI. The rest of the function time of the pacemaker was calculated. Measurements were again performed after 99.5 +/- 29.6 minutes (mean +/- SD), immediately after MRI examination, and 3 months later. Lead impedance and sensing and stimulation thresholds did not change after MRI. Battery voltage decreased immediately after MRI and recovered 3 months later. Battery current and impedance tended to increase. The calculated rest of function time did not change immediately after MRI. MRI affected neither pacemaker programmed data, nor the ability to interrogate, program, or use telemetry. Surprisingly, in the gantry of the scanner, temporary deactivation of the reed switch occurred in 12 of 32 patients when positioned in the center of the magnetic field. Missing activation of the reed switch through the static magnetic field at 0.5 Tesla is not unusual. MRI at 0.5 Tesla does not cause irreversible changes in patients' pacemaker systems.
Inappropriate therapy of SVTs by ICDs remains a major clinical problem despite enhanced detection criteria like "sudden onset" and "rate stability" in third-generation devices. Electrogram morphology discrimination offers an additional approach to improve discrimination of supraventricular tachycardia (SVT) from ventricular tachycardia (VT). In a prospective, multicenter study, patients received an ICD with a beat-to-beat algorithm for morphological analysis of the intracardiac electrogram (Morphology Discrimination, MD). A nominal programmingfor standard enhancement criteria and morphology discrimination was required at implant. Electrogram storage of tachycardia episodes irrespective of delivery of therapy was used to assess sensitivity and specificity of the morphology algorithm alone and in combination with established detection criteria. During a 126 6-month follow-up, 886 episodes of device stored electrograms from 82 of 256patients were evaluated. Atnominal settings, the MD algorithm correctly identified 423 of 551 episodes as VT resulting in sensitivity of 77%. The classification of SVT was met in 239 of 335 episodes resulting in specificity of 71%. In combination with sudden onset, sensitivityincreased to 99.5% at the expense of specificity (48%). In conclusion, SVT-VT discrimination based on morphological analysis alone results in limited sensitivity and specificity. Programming the monitor mode allows individual assessment of the performance of this detection enhancement feature during clinical follow-up without compromising device safety. Only in patients with documented efficacy of morphology discrimination should this feature be subsequently activated.
INTRODUCTION: Management of atrial tachyarrhythmias represents a significant challenge in patients with implantable cardioverter defibrillators (ICDs). Drug therapy of these arrhythmias is limited by moderate efficacy, ventricular proarrhythmia, and drug-device interactions. This study tested the safety and efficacy of a new dual-chamber ICD to detect and treat atrial as well as ventricular tachyarrhythmias. METHODS AND RESULTS: A dual-chamber ICD (Medtronic 7250 Jewel AF) was implanted in 293 of 303 patients at 49 centers in Europe, Canada, and North America. Specific data were collected at implant and during a mean follow-up period of 7.9+/-4.7 months. There were no clinically evident failures to detect and treat ventricular arrhythmias. In patients with at least one of the dual-chamber detection criteria activated, 1,056 of 1,192 episodes of ventricular tachycardia or fibrillation detected were judged to be appropriate (89% positive predictive accuracy). Therapy efficacy was 100% in the ventricular fibrillation zone and 98% in the ventricular tachycardia zone. Positive predictive accuracy for detection of atrial episodes was 95% (1,052/1,107). For episodes classified as atrial tachycardia by the device, the efficacy of atrial antitachycardia pacing and high-frequency (50-Hz) burst pacing was 55% and 17%, respectively. High-frequency burst pacing terminated 16.8% of episodes classified as atrial fibrillation, and atrial defibrillation had an estimated efficacy of 76%. The actuarial estimates of 6-month complication-free survival and total survival were 88% and 94%, respectively. CONCLUSION: This novel dual-chamber ICD is capable of safely and effectively discriminating atrial from ventricular tachyarrhythmias and of treating atrial tachyarrhythmias without compromising detection and treatment of ventricular tachyarrhythmias.
The natural killer cell-activating anti-CD16/CD30 bispecific monoclonal antibody (BiMAb) had shown efficacy in a Phase I/II trial of refractory Hodgkin's disease (HD). To gain additional information on clinical efficacy and to investigate the effects of different application schedules and the concomitant application of cytokines, we performed a second randomized pilot trial using this BiMAb in patients with refractory HD. Patients received 4 x 25 mg HRS-3/A9 either as a continuous infusion for 4 days or as a 1-h infusion every other day. In case of an objective response, retreatment was attempted after 4 weeks; in case of stable disease (SD), a second course was given after prestimulation with interleukin 2 and followed by granulocyte macrophage colony-stimulating factor s.c. A total of 16 heavily pretreated patients received one to four BiMAb courses. Overall, we observed one complete remission and three partial remissions lasting 5-9 months (three of four of these responses occurred after continuous BiMAb infusion) and four cases of SD for 3 to >6 months. Interleukin 2 pretreatment before the second BiMAb course resulted in a significant increase of circulating natural killer cells in all five patients treated. This coincided with the conversion of two cases of SD into one complete remission and one partial remission. HRS-3/A9-related side effects consisted of mild fever in only six patients. In summary, this second trial confirmed the antitumor efficacy of this BiMAb against HD and the minor toxicity of this BiMAb. Coadministration of cytokines might contribute to an augmented antitumor activity, and additional clinical trials are warranted to optimize this novel treatment modality.
The induction of interleukin-6 (IL-6) using combined proinflammatory agents (LPS/IFN-gamma or TNF-alpha/IFN-gamma) was studied in relation to p38 mitogen-activated protein kinase (MAPK) and NF-kappaB transcriptional factor in primary neonatal cardiomyocytes. When added to cultures of cardiomyocytes, the combined agents (LPS/IFN-gamma or TNF-alpha/IFN-gamma) had stimulatory effect on the production of IL-6 and the elevation was significantly reduced by SB203580, a specific p38 MAPK inhibitor. SB203580 inhibited protein production and gene expression of IL-6 in a concentration-dependent manner. In this study, IFN-gamma enhancement of TNF-alpha-induced NF-kappaB binding affinity as well as p38 MAP kinase activation was observed. However, a specific inhibitor of p38 MAPK, SB203580, had no effect on TNF-alpha/IFN-gamma or LPS/IFN-gamma-induced NF-kappaB activation. This study strongly suggests that these pathways about TNF-alpha/IFN-gamma or LPS/IFN-gamma-activated IL-6 release can be primarily dissociated in primary neonatal cardiomyocytes.
BACKGROUND AND OBJECTIVE: Compared with conventional echocardiography (CEC) harmonic imaging (HEC) provides better resolution of the endocardial line and valvular apparatus. This prospective study was undertaken to compare the value of harmonic and conventional transthoracic echocardiography in endocarditis and compare them with standard transoesophageal echocardiography (TOE) and operative findings. PATIENTS AND METHOD: Conventional and harmonic echocardiographic imaging was compared in 30 patients (aged 58 +/- 17 years; 19 males and 11 females) with endocarditis clinically judged to require surgical intervention. The results of both methods were then compared with those of standard TOE and the intraoperative findings. RESULTS: Intraoperatively 15 floating structures, 9 abscesses and 5 perforations were demonstrated. Transoesophageal echocardiography was better than the standard method in diagnosing floating structures and detecting abscesses (15 vs. 10 vegetations, p < 0.05; 7 vs. 5 abscesses, p = 0.05). TOE was better than either method in the diagnosis of abscess. CONCLUSION: Harmonic transthoracic echocardiography is better than the conventional mode in diagnosing complications of endocarditis.
Atrial fibrillation (AF) is a frequent and costly health care problem. In patients with AF, the restoration and maintenance of sinus rhythm is the primary therapeutic goal. The most frequent strategy for maintaining sinus rhythm after restoration is the use of antiarrhythmic drugs. The efficacy of therapy in AF has been predominantly measured using objective criteria such as mortality and morbidity. In recent years, the importance of quality of life (QoL) as an outcome measure has been recognized. However, few studies in the literature have examined QoL in patients with AF using properly validated tools. In addition, the specific impact of antiarrhythmic drug treatment on QoL in patients with AF has not been assessed. These issues are now being addressed in several ongoing studies. This article attempts to define QoL, makes recommendations on how QoL might be assessed, reviews our current knowledge regarding QoL in patients with AF, and discusses new clinical trials currently assessing QoL in patients with AF.
BACKGROUND: The recent availability of implantable cardioverter-defibrillators (ICDs) that record 1024 R-R intervals preceding a ventricular tachyarrhythmia (VTA) provides a unique opportunity to analyze heart rate variability (HRV) before the onset of VTA. METHODS AND RESULTS: Fifty-eight post-myocardial infarction patients with an implanted ICD for recurrent VTA provided 2 sets of 98 heart rate recordings in sinus rhythm: (1) before a VTA and (2) during control conditions. Three subgroups were considered according to the antiarrhythmic (AA) drug regimen. A state of sympathoexcitation was suggested by the significant reduction in HRV before VTA onset compared with control conditions. beta-Blockers and dl-sotalol enhanced HRV in control recordings; nevertheless, HRV declined before VTA independent of AA drugs. A gradual increase in heart rate and decrease in sinus arrhythmia at VTA onset were specific findings of patients who received dl-sotalol. CONCLUSIONS: The peculiar heart rate dynamics observed before VTA onset are suggestive of a state of sympathoexcitation that is independent of AA drugs.
HISTORY AND CLINICAL FINDINGS: A 78-year-old patient experienced dizziness, impairment of mnemic and cognitive function, chronic fatigue and recurrent syncope. INVESTIGATIONS: Hypertensive heart disease, reduced left ventricular function, and ventricular ectopia classification Lown IVb was documented. Computed tomography showed minimal brain atrophia. Stenoses of the brain supplying arteries and of other intracranial diseases were excluded. A distinct correlation between cardiac output and cerebral blood flow in correspondence to changes of heart rate were found (cardiac output 4.2 l/min during sinus rhythm, 7.4 l/min during temporary atrial pacing--AAI-Mode with a pacing rate of 90/min; 4.8 l/min--AAI-Mode with a pacing rate of 120/min; cerebral blood flow: 70, 74 and 62 ml/100 g per minute, respectively). Thus, impairment of cerebral blood flow autoregulation can be assumed. TREATMENT AND COURSE: After implantation of a permanent pacemaker the patient was without any complaints. The mnemic and cognitive function improved, dizziness and fatigue disappeared. Synopsis did not occur. 14 months later a sudden onset of complaints occurred caused by atrial fibrillation (heart rate 120/min). Cardiac output and cerebral blood flow were now 4.0 l/min and 35 ml/100 g per minute. After antiarrhythmic drug therapy and restoration of sinus rhythm cardiac output and cerebral blood flow increased and the complaints disappeared again. CONCLUSION: In patients with impaired capacity of cerebral autoregulation a reduced cardiac function and output can induce a reduction of cerebral blood flow. Thus, impairment of mnemic and cognitive function as well as other unspecific neurological deficits can be caused. In these cases pacemaker therapy has to be discussed as an effective therapeutical concept.
BACKGROUND: To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. METHODS AND RESULTS: We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length <300 ms). Intermittent sensing of far-field R waves during sinus tachycardia caused 27 inappropriate AT/AF detections; these detections lasted 2.6+/-2.0 minutes. AT/AF was detected continuously in 27 of 28 patients who had spontaneous episodes of AT/AF (96%). The device memory recorded 90 appropriate AT/AF episodes lasting >1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. CONCLUSIONS: A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.
Previous experimental studies showed that the benefit of ischemic preconditioning (IPC) is abolished by K(ATP) channel blockade with glibenclamide. However, the newly discovered K(ATP) channel blocker HMR 1883 (1-[[5-[2-(5-chloro-o-anisamido)ethyl]-methoxyphenyl]sulfonyl]-3-m ethylthiourea) shows marked antifibrillatory activity in the dose range of 3 mg/kg to 10 mg/kg i.v. in various experimental models without affecting blood glucose levels. In order to investigate in a head to head comparison glibenclamide and HMR 1883 with respect to their influence on IPC, experiments were performed in rabbits with ischemia-reperfusion using myocardial infarct mass as final read out. Male New Zealand White rabbits (2.6-3.0 kg) were subjected to 30-min occlusion of a branch of the left descending coronary artery (LAD) followed by 2-h reperfusion. For IPC experiments the LAD was additionally occluded for two periods of 5 min, each followed by 10-min reperfusion, before the long-term ischemia. Infarct mass was evaluated by TTC staining and expressed as a percentage of area at risk. Rabbits (n=7/group) were randomly selected to receive (i.v.) saline vehicle 5 min prior to the 30-min occlusion period in infarct studies without IPC or to receive glibenclamide (0.3 mg/kg) or HMR 1883 (3 mg/kg) in IPC experiments, these substances being given 5 min prior to the first preconditioning or 5 min prior to the long-term ischemia of 30 min. Myocardial risk mass as a percentage of left ventricular mass did not differ between groups. The same was true for the ratio of left ventricular mass to 100 g body weight. Myocardial infarct mass as a percentage of the area at risk in the saline vehicle group without IPC was 41+/-3%. Whereas glibenclamide significantly increased infarct mass (from 41+/-3% to 55+/-4%), HMR 1883 did not affect it. IPC reduced infarct mass from 41+/-3% to 21+/-4% (P<0.05 vs. control without IPC). Glibenclamide given prior to IPC or prior to the long-term ischemia totally abolished the IPC effect (42+/-2% and 55+/-4%, respectively; P<0.05 vs. control). In contrast, HMR 1883 under the same conditions did not affect infarct size when given prior to IPC or prior to the long-term ischemia (21+/-3% and 26+/-2%, respectively). The monophasic action potential duration (MAP50) was reduced from 103+/-3 ms under normoxic conditions to 82+/-2 ms, 5 min after ischemia in the absence of drugs. This ischemia-induced shortening of the MAP was prevented by both HMR 1883 (MAP50 103+/-3 ms) and glibenclamide (MAP50 106+/-3 ms). In conclusion, although both K(ATP) channel blockers prevented ischemia-induced shortening of MAP, HMR 1883 did not abolish the beneficial effects of IPC on myocardial infarct mass in rabbits, whereas glibenclamide totally reversed this cardioprotective effect of IPC. This suggests that the sarcolemmal ATP-sensitive potassium channels are not involved in the mechanism of IPC.
Fifteen patients with refractory Hodgkin's disease were treated in a dose-escalation trial with the bispecific monoclonal antibody (bi-mAb) HRS-3/A9, which is directed against the Fc gamma receptor III (CD16 antigen) and the Hodgkin's-associated CD30 antigen. Treatment consisted of four cycles of four bi-mAb infusions given over 1 h every 3-4 days at different dose levels ranging from 1 mg/m2 to 64 mg/m2. Measurable serum levels (above 0.1 microgram/ml) of circulating bi-mAb could be detected in patients treated with doses above 4 mg/m2, reaching peak levels of 9.5 micrograms/ml immediately after the end of antibody infusion on the highest dose level. Bi-mAb elimination corresponded to second-order kinetics with a terminal half-life time (t1/2, beta) of 28-32 h. Bi-mAb treatment induced the occurrence of human anti-(mouse Ig) antibodies (HAMA) in 6 out of 13 patients initially testing negative. All 6 patients not only developed anti-isotypic anti-(mouse Ig) but also anti-idiotypic and anti-anti-idiotypic antibodies. While no consistent changes of peripheral blood cell counts, or of any lymphocyte subpopulation including natural killer (NK) cells, has been observed, 4 out of 6 evaluable patients treated with doses of at least 4 mg/m2 showed an increase of NK cell activity within 2 weeks after treatment, which lasted for a maximum of 12 weeks. Circulating amounts of soluble CD30 antigen could be detected in the serum of 6 patients. However, like the results and time courses of all the other immunological parameters evaluated, this was not predictive for treatment outcome.
The majority of cardioverter/defibrillator (ICD) implantations are currently performed with a non-thoracotomy approach. From November 1993 to January 1995, 46 patients underwent implantation of a PCD 7219C with an "active-can" lead configuration at our institution. While the chronic stability of the defibrillation threshold (DFT) for an epicardial lead system is well established, the results are still inconsistent for non-thoracotomy lead systems. Accordingly, the aim of the present study was to compare the acute and chronic defibrillation thresholds of the ICDs implanted with an "active-can" lead system in order to assess the chronic stability of these systems. The defibrillation energy requirements were measured at implant, prior to hospital discharge, three, six and twelve months after implantation of the defibrillator. The patient group consisted of 8 females and 38 males with a mean age of 57.2 years. The mean left ventricular ejection fraction was 43.8%. The most frequent underlying heart disease was coronary artery disease in 31 of 46 patients. Eight patients had idiopathic dilated cardiomyopathy. In 39 of 46 patients, the defibrillation threshold could be successfully determined at all 4 time points after implantation. The mean defibrillation energy requirement at the time of implantation was 9.2 +/- 5.9 Joules (J). The subsequent mean energy requirements were 7.6 +/- 4.8 J at pre-hospital discharge, 8.6 +/- 5.7 J at the 3 month, 8.1 +/- 6.0 J at the 6 month and 8.6 +/- 5.8 J at the 12 month follow-up visits. The mean defibrillation threshold was lowest at the time of prehospital discharge, significantly lower than at the time of initial implantation (p = 0.021). However, at all later time points up to one year, there was no significant difference in the DFT as compared with the time of initial implantation. Comparing the DFT at the time of implantation and the DFT at all other time points, there were no significant differences (9.23 vs. 8.56 J, p = 0.291). Although there was an initial decrease in the DFT at seven to ten days, the long-term stability of the DFT up to one year remained stable in the devices with the "active-can" lead system.
OBJECTIVES: We sought to evaluate the number and duration of device-treated and self-terminating, nontreated episodes of atrial fibrillation (AF) after implantation of the Metrix Atrioverter. BACKGROUND: A recent study has shown that the Atrioverter can rapidly restore sinus rhythm in patients with AF; however, the effect of the device on the clinical course of the arrhythmia in these patients is unknown. METHODS: The Atrioverter was implanted in 51 patients with symptomatic, recurrent, drug-refractory AF. The device was programmed to periodically monitor the cardiac rhythm. Defibrillation of AF episodes was performed under physician observation. RESULTS: During a mean follow-up of 260 +/- 144 days, 1,161 episodes of AF were observed during valid monitoring periods in 45 of 51 patients. Forty-one patients experienced 231 episodes for which they sought defibrillation therapy. The average duration of the treated episodes during valid monitoring periods (190 of 231 episodes in 39 of 41 patients) was significantly longer than that of the nontreated episodes (38 +/- 44 vs. 10 +/- 8 h; p < 0.05). The time between episodes requiring Atrioverter therapy increased, and the risk of having an episode requiring treatment decreased. No changes were observed in the number and duration of the short-lasting, nontreated episodes as time since implantation of the device increased. CONCLUSIONS: In patients with symptomatic, recurrent, drug-refractory AF, the frequency of long-lasting episodes, which were treated under observation with repeated defibrillation using the Atrioverter, decreased. The number and duration of short-lasting, nontreated episodes did not change during the 20-month study period. The effect of ambulatory use of the device on the recurrence of short-lasting episodes needs to be evaluated.