Search PubMedSearch

Biomedical subjects

W J Vincent

Publications and source records attributed to W J Vincent.

4 recordsLinked to original sources

Changes in cardiovascular function during inversion.

Although inversion therapy is used increasingly as a therapy for musculoskeletal back disorders, its effects on cardiovascular function have not been systematically determined. Heart rate, blood pressure and echocardiographic measurements were performed in 20 normal male volunteers before, during and after bent-knee inversion. Compared to control measurements in the supine position, inversion significantly increased heart rate, systolic and diastolic blood pressure, rate-pressure product, systemic vascular resistance and left ventricular (LV) wall stress. Inversion also resulted in a significant decrease in LV diastolic volume, cardiac output and ejection fraction. Thus inversion produces an increase in LV afterload and myocardial oxygen demand concomitantly with a decrease in LV preload and global systolic function, and may be contraindicated in patients with cardiovascular disease.

Adult

Monitoring personal exposure to ethylenediamine in the occupational environment.

A method for monitoring exposure to ethylenediamine (EDA) in the occupational environment is described. The EDA is adsorbed on activated silica gel, desorbed with 0.5 percent aqueous cupric chloride, and analyzed by gas chromatography using a 2 percent KOH on a Chromosorb 103 column. The method is sensitive to 200 micrograms/mL EDA and can detect 1.0 ppmv EDA in samples collected for 4.5 hours at a 300 cc per minute flow. The method has been evaluated in the laboratory and under plant conditions. Other amines do not interfere with the determination of EDA.

Air Pollutants

Sampling and analysis of acetic anhydride in air.

This paper describes the development of a new method for monitoring acetic anhydride in the presence of acetic acid in the occupational environment. The method consisted of collecting airborne acetic anhydride on a solid sorbent, desorbing it with acetone and analyzing it by gas chromatography. During the development of this method various parameters such as selection of column, selection of solid sorbent, selection of desorber solvent, effects of humidity, flow rate, total sample volume, desorption efficiency, and shelf-life of samples were studied. Interference from methyl acetate, water, formic acid, and acetic acid was also tested with the determination of acetic anhydride.

Acetates