Automatic mechanical device to standardize active compression-decompression CPR.

STUDY OBJECTIVE: To develop an automatic mechanical device capable of performing active compression-decompression (ACD) CPR in laboratory animals. DESIGN: A swine model was used to study standard and ACD CPR. One-minute periods of standard mechanical chest compressions were alternated with mechanical ACD CPR. SETTING: University hospital laboratory. INTERVENTIONS: A commercially available device that provided standard chest compressions only was modified to deliver ACD CPR. RESULTS: The absolute difference in intrapleural pressure and tidal volume almost doubled during ACD CPR compared with that with standard CPR. CONCLUSION: The presence of a greater negative change in intrapleural pressure confirmed that active decompression of the chest had occurred and that the device was capable of performing ACD CPR. The device provides consistent rate, depth, force, and duty cycle.

Animals

End-tidal carbon dioxide during extremely low cardiac output.

STUDY OBJECTIVE: A number of studies have shown that expired CO2 concentration is closely related to cardiac output, but that cardiac output was not controlled as an independent variable. In addition, the partial pressure of end-tidal CO2 (PETCO2) during extremely low cardiac output has not been reported. The objective of the present study was to measure PETCO2 during well-controlled, very low blood flow rates under conditions of constant minute ventilation. DESIGN: Ten anesthetized, intubated, and mechanically ventilated swine (weight, 43 to 102 kg) were placed on two ventricular assist devices in order to control cardiac output. Minute ventilation was measured and kept constant. Ventricular assist device output (measured with an ultrasonic flow probe); PETCO2; and aortic, pulmonary artery, and central venous pressures were recorded continuously. INTERVENTIONS: After electrical induction of ventricular fibrillation, pump output was decreased in steps. MEASUREMENTS AND MAIN RESULTS: Cardiac index ranged from 0 to 5,371 mL/min/m2; 59% of PETCO2 measurements were made at cardiac indexes of less than 1,313 mL/min/m2 (30 mL/min/kg). The relationship of PETCO2 levels to cardiac index was determined with linear regression analysis; P < .05 was statistically significant. PETCO2 correlated significantly with cardiac index (P < .0001). The best-fit line by least-squares analysis produced the equation: PETCO2 = 4.98 + 0.012 [cardiac index] (r2 = .82). CONCLUSION: Under conditions of constant minute ventilation, PETCO2 correlated closely with cardiac index over a large range of blood flow rates, including extremely low rates.

Animals

Effect of ventilation on resuscitation in an animal model of cardiac arrest.

BACKGROUND: The need for ventilation during the initial management of cardiac arrest is an important public health problem that is being debated. The present study was designed to determine whether ventilation affects return of spontaneous circulation from cardiac arrest in a swine model with an interval of untreated ventricular fibrillation of 6 minutes, as reported in witnessed out-of-hospital human cardiac arrest. METHODS AND RESULTS: Twenty-four animals were randomly assigned to two groups: one that received ventilation during the first 10 minutes of chest compression and one that did not. Coronary perfusion pressure and minute ventilation were continuously recorded. Arterial and mixed venous blood gases were measured at intervals. Return of spontaneous circulation was defined prospectively as an aortic systolic blood pressure of > 80 mm Hg for > 5 minutes and was the primary outcome variable. All animals were anesthetized, paralyzed, and intubated. Ventricular fibrillation was induced and persisted for 6 minutes without chest compression, followed by mechanical chest compression for 10 minutes and then attempted defibrillation. Animals without return of spontaneous circulation were given epinephrine, ventilation, and chest compression for an additional 3 minutes. Defibrillation was again attempted, and animals were assessed for return of spontaneous circulation. There were no significant differences between the two groups in baseline prearrest mean cardiac index, coronary perfusion pressure, or arterial and mixed venous blood gases. However, after 9 minutes of chest compression, significant differences were noted between the ventilated and nonventilated groups. The nonventilated group had significantly (P < .05) lower mean arterial PO2 (38 +/- 17 mm Hg compared with 216 +/- 104 mm Hg) and higher PCO2 (62 +/- 16 mm Hg compared with 35 +/- 8 mm Hg), lower mixed venous PO2 (15 +/- 7 mm Hg compared with 60 +/- 7 mm Hg). Nine of 12 (75%) of the ventilated animals, and only 1 of 12 (8%) of the nonventilated animals had return of spontaneous circulation after cardiac arrest (P < .002). CONCLUSIONS: In this animal model of cardiac arrest, ventilation was important for resuscitation. The importance of ventilation could be related to the prolonged duration of untreated ventricular fibrillation and the significantly greater hypoxia and hypercarbic acidosis found in the nonventilated animals.

Animals

Effect of ventilation on acid-base balance and oxygenation in low blood-flow states.

OBJECTIVES: To investigate how minute ventilation affects the partial pressure of end-tidal CO2 and arterial and mixed venous pH, PCO2, PO2, and the concentration of bicarbonate during low blood-flow states. We tested the null hypothesis that acid-base conditions during low rates of blood flow are not significantly different when minute ventilation is doubled or halved. DESIGN: Prospective, experimental, animal study. SETTING: University hospital laboratory. SUBJECTS: Domestic swine. INTERVENTIONS: We studied ten anesthetized and mechanically ventilated swine (weight, 43 to 102 kg) in a new model of controlled systemic and pulmonary blood flow in which each animal was maintained on ventricular assist devices. After electrical induction of ventricular fibrillation, ventricular assist device blood flow was decreased in steps. At each decrease, control minute ventilation, two times the control minute ventilation (hyperventilation), and one-half the control minute ventilation (hypoventilation) were administered; each ventilatory change was maintained for 6 mins. MEASUREMENTS AND MAIN RESULTS: Aortic, pulmonary arterial and central venous pressures, ventricular assist device blood flow, and end-tidal CO2 were recorded continuously. Acid-base conditions were studied at three different mean blood flow rates: 49%, 30%, and 12% of baseline prearrest cardiac index. Arterial pH and PaO2 and mixed venous pH varied directly (p < .003) with minute ventilation, while PaCO2 and mixed venous PCO2, and end-tidal CO2 varied inversely (p < .0001) with minute ventilation. Mixed venous PO2 was not significantly related to minute ventilation (p = .6). PaCO2 and arterial bicarbonate; mixed venous pH, mixed venous PO2, and mixed venous bicarbonate, and end-tidal CO2 varied directly (p < .001) with blood flow, while mixed venous PCO2 varied inversely with blood flow (p < .05). Arterial pH was not significantly related to blood flow (p = .3). When minute ventilation changed from hyperventilation to hypoventilation at a mean blood flow rate of 49%, mean arterial pH decreased 0.22 +/- 0.06 (p < .05), mean PaCO2 increased 28 +/- 6 torr (3.7 +/- 0.8 kPa) (p < .05), and mean PaO2 decreased 99 +/- 77 torr (13.2 +/- 10 kPa); mean mixed venous pH decreased 0.11 +/- 0.02, mean mixed venous PCO2 increased 16 +/- 2.2 torr (2.1 +/- 0.3 kPa) (p < .05), and mean mixed venous PO2 did not change; mean end-tidal CO2 increased 18 +/- 2 torr (2.4 +/- 0.3 kPa) (p < .05). The effect of changes in minute ventilation on blood gases and end-tidal CO2 was similar for mean blood flow rates of 30% and 12% of baseline cardiac index. CONCLUSIONS: During low rates of blood flow similar to those rates found in shock and cardiopulmonary resuscitation, alterations in minute ventilation significantly influenced end-tidal CO2 and both arterial and mixed venous pH and PCO2. These findings may have clinical importance in improving the treatment of shock and cardiac arrest.

Acid-Base Equilibrium