Hemodynamic comparisons of polyurethane trileaflet and bioprosthetic heart valves.

Hemodynamic comparison of two polyurethane prosthetic heart valves with a bioprosthetic valve is presented. The valves were incorporated in a pulse duplicator simulating physiologic pulsatile flow, and comparisons between the valves were made on the transvalvular pressure drop, percent regurgitation, valve orifice area, rate of opening and closing as well as the performance index. The results showed that the functional characteristics of the polyurethane valve compared favorably with that of the bioprosthetic valve. The polyurethane valve can be a viable and inexpensive alternative, especially for short-term use in a total artificial heart as a bridge to transplant.

Bioprosthesis↗

A comparison of the antiplatelet effect of aspirin on human and bovine platelets.

The risk of thromboembolism in human patients or animal models with blood contacting prosthetic devices is well documented. Aspirin is used frequently as an antiplatelet agent to minimize this risk. Although the inhibitory effect of aspirin on human platelets has been clearly established, preliminary studies to examine this effect on bovine platelets revealed a minimal inhibition of platelet function in vivo as well as in vitro. Because a considerable amount of implant research is carried out in bovine models, it was considered important to evaluate carefully the antiplatelet effect of aspirin on bovine platelets. To evaluate the effect of aspirin, experiments were conducted on human and bovine blood in vitro as well as after the administration of aspirin up to 4,000 mg/day (p.o.) in calves and 2,500 mg/day in humans. Appropriate amounts of buffered aspirin were added to heparinized or citrated blood incubated for 25 min and centrifuged to obtain platelet rich plasma (PRP). An aliquot of PRP was then challenged by a predetermined concentration of ADP (an aggregating agent) or collagen to evaluate platelet aggregation and release reaction. After aspirin was administered in vivo, blood was drawn from the animal at predetermined intervals to evaluate platelet function. In human blood, the inhibitory effect of aspirin was discernable at 80 mg/L in vitro and 2,500 mg/day when ingested orally. Under identical experimental conditions, no inhibition of bovine platelet aggregation was observed using dosages of aspirin up to 1,000 mg/L in vitro or 4,000 mg/day in vivo.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenosine Triphosphate↗

New polyurethane valves in new soft artificial hearts.

This article describes new bistable valves, and introduces a new soft heart that is easy to implant. Earlier, five polyurethane (PU) valves were implanted in the mitral position in sheep. All five survived for 1 year or more, and the valves, although calcified, were intact. Since the opening resistance was somewhat high, valves that are bistable were developed, which means they may be open or closed. These valves have lower opening resistance, and regurgitation is similar to that of mechanical valves. Eight calves have been implanted with a new, soft total artificial heart (TAH). Seven had bistable leaflet valves; the eighth had mechanical (Bicer) valves in the inflow position. Four of the calves were sacrificed after 22 to 43 days. At autopsy, the number of thromboemboli found, particularly in the kidneys, was low compared with previous experiments. None of these animals received anticoagulants other than the heparin given during heart/lung bypass.

Animals↗

An in vitro test model to study the performance and thrombogenicity of cardiovascular devices.

During the development of cardiovascular devices, it is necessary to evaluate their performance in vitro under experimental conditions that closely resemble their use in vivo. Therefore, an in vitro test model was developed to evaluate the performance of cardiovascular devices with blood. The in vitro test model consists of a pneumatically driven 50 cc polyurethane ventricle with either mechanical or experimental polyurethane tricuspid semilunar valves, connected to a horseshoe-shaped blood reservoir. A sampling port permits frequent removal of blood for hematologic evaluation. All the couplings are of the quick connect type to facilitate assembly and exchange of parts. The total volume of blood in the test model is approximately 1.4 L, and experiments are conducted in the absence of an air-blood interface. Except for mechanical valves and the chosen test interface, the entire blood contacting surface consists of polyurethane. Fresh bovine heparinized blood is used for the experiments. After filling the reservoir and the ventricle with blood, the concentration of heparin is adjusted with protamine to an APTT level of three times normal (80-100 sec). Once this level of anticoagulation is achieved, the blood is circulated for the next 2-3 hr at the desired test parameters (beats/min, cardiac output, etc.). A number of hematologic parameters are monitored during the test, including APTT, PT, plasma free hemoglobin and ADP-induced platelet aggregation. With the help of this model a number of devices, including experimental polyurethane tricuspid semilunar valves, Silastic tube valves, valves with heparin coated leaflets, and small (50 cc) experimental ventricles have been studied.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗