Search PubMed⌕ Search

Biomedical subjects

W J Feuer

Publications and source records attributed to W J Feuer.

68 records · Page 4Linked to original sources

Pseudo-loss of fixation in automated perimetry.

During automated perimetry with the Humphrey Visual Field Analyzer, field examinations are labeled unreliable whenever the reported rate of fixation loss is 20% or more. The reported rate of fixation loss results in part from times when the patient's gaze drifts from the fixation point during the examination, but also in part from technical artifacts such as faulty initial localization of the blind spot or false-positive responses by the patient. It was found that technical artifacts caused nearly half of the instances in which a field examination had a reported fixation loss rate of greater than 20%. It was also found that the perimetrist can prevent the artifacts, with the result that the frequency of field examinations labeled as having excessive fixation loss fell from 26% to 14%.

Automation↗

Nd:YAG cyclophotocoagulation: outcome of treatment for uncontrolled glaucoma.

We reviewed the records of 35 patients (35 eyes) treated with Nd:YAG cyclophotocoagulation for uncontrolled glaucoma and followed for 6 to 36 months or until treatment was declared a failure (loss of light perception, or intraocular pressure (IOP) greater than 21 mm Hg). The mean pretreatment intraocular pressure was 37.9 mm Hg (range, 20 to 61 mm Hg). The total energy in the initial treatment session ranged from 50.4 to 372.4 J (191.7 +/- 66.3 J). After the treatment, the mean IOP was 21.2 mm Hg (range, 0 to 53 mm Hg). The Kaplan Meier survival analysis demonstrated that failures occurred throughout the follow-up period and that the majority of patients required further intervention or lost all vision if followed long enough. Visual outcome was not correlated with energy used. Eleven eyes (31%) lost two or more lines of acuity or lost all light perception. These findings suggest that Nd:YAG cyclophotocoagulation may control IOP but cannot always save vision.

Adolescent↗

Contact B-scan echography in the assessment of optic nerve cupping.

We determined the reliability of high-resolution contact B-scan echography for estimating the optic cup size in 56 eyes of 28 patients with glaucoma or ocular hypertension. Two trained observers independently evaluated horizontal and vertical cup/disk ratios in stereophotographs, and two skilled echographers independently estimated optic cup size in photoechograms in a masked fashion. The reliability of echographic interpretation varied (kappa 0.29 to 0.71), but it always exceeded that expected by chance alone, even for cups of 0.3 disk diameter or less. Subtly saucer-shaped cups (three of 50 eyes) and deep cups with intact neuroretinal rims (two of 50 eyes) were misinterpreted echographically. High-resolution contact B-scan echography may provide a useful and reliable estimate of the optic cup size in eyes with opaque media.

Fundus Oculi↗

The influence of decreased retinal illumination on automated perimetric threshold measurements.

Decreased retinal illumination (such as can be caused by pupillary constriction or light absorption by ocular media opacities) was simulated with a randomly ordered series of neutral density filters in front of the right eyes of five subjects with dilated pupils. Threshold measurements were performed on Humphrey and Octopus perimeters at 0, 5, 10, 15, 20, and 25 degrees nasally along the 180-degree meridian. A 0.6-log unit neutral density filter, which reduces retinal illumination the equivalent of halving the pupillary diameter, decreased the mean Humphrey thresholds by 1.1 +/- 0.8 decibels (dB) (mean +/- standard deviation) and the mean Octopus thresholds by 1.7 +/- 1.4 dB. Statistically significant (P less than or equal to .05, Dunnett's test) threshold depressions were observed at all eccentricities with a 1.5-log unit neutral density filter on the Humphrey perimeter (-4.5 +/- 0.7 dB) and with a 1.0-log unit neutral density filter on the Octopus perimeter (-3.5 +/- 1.0 dB).

Adult↗

Threshold equivalence between perimeters.

To determine equivalence between perimeters, 49 eyes of 35 subjects underwent static threshold testing of the central 30 degrees twice on each of three automated perimeters and twice by manual kinetic threshold testing with the Goldmann perimeter. The Octopus-Humphrey difference was 3.3 dB (2.3 dB in the upper two rows for programs 32 and 30-2). The Dicon-Octopus difference was 3.5 dB and the Dicon-Humphrey, 6.5 dB. The I4e stimulus of the Goldmann perimeter was equivalent to 17.1 dB, 13.6 dB, and 10.8 dB on the Humphrey, Octopus, and Dicon perimeters, respectively. The III4e stimulus of the Goldmann perimeter, used for visual impairment determination, was roughly equivalent to 7 to 10 dB, 4 to 7 dB, and 0 to 6 dB on the Humphrey, Octopus, and Dicon perimeters, respectively. The prediction when converting from one instrument to another was only 10% less reliable than the ability of a perimeter to predict the values on a second examination with the same perimeter. Validity of the conversion formulas was confirmed by the age-corrected normal values available for the Octopus, Humphrey, and Goldmann perimeters.

Adult↗

Evaluation of phototoxic retinal damage after argon laser iridotomy.

We performed several visual function tests in 17 eyes (ten patients) before and after argon laser iridotomy in an effort to detect diffuse photochemical damage to photoreceptors caused by exposure to the intense, blue-green light that is transmitted into the posterior segment as the iridotomy is created and enlarged. No change was detected in static threshold sensitivity in the central 30 degrees of the field (Octopus perimeter), color sensitivity (Farnsworth-Munsell 100-Hue test), or visual acuity. Contrast sensitivity showed a small increase at low spatial frequencies and a small decrease at high spatial frequencies. The latter change was small and not necessarily laser related, but precautions to limit laser exposure of the posterior pole are prudent.

Argon↗

Interocular asymmetry of visual function in heterozygotes of X-linked retinitis pigmentosa.

Heterozygotes of X-linked retinitis pigmentosa were studied with full field rod and cone electroretinography and light adapted kinetic perimetry. Twelve parameters from the electroretinograms (ERGs) and two parameters from the kinetic visual fields of both eyes of 22 heterozygotes were measured and statistical comparisons made with results from female control subjects. Rod and cone ERG amplitude parameters were significantly lower and cone timing delayed in the heterozygotes. Most of the ERG parameters that were abnormal in measured value also showed significantly greater interocular differences compared with controls. Kinetic visual fields with both V-4e and I-4e test targets were smaller in heterozygotes than in controls. Only with the I-4e target, however, were interocular differences significantly larger in the heterozygotes. For the I-4e target and many of the ERG parameters, using the interocular difference in conjunction with the measured parameter value from a single eye significantly increased the efficacy of discrimination between heterozygotes and controls; for some ERG parameters, the interocular difference alone provided the best separation of the two groups.

Adolescent↗

Static threshold asymmetry in early glaucomatous visual field loss.

Ten normal subjects underwent static threshold visual field testing of both eyes with the Humphrey perimeter, with one eye tested twice. The mean sensitivity of the field seemed virtually identical in the two eyes, with the average difference between the right and left eyes (0.65 decibels [dB]) being no greater than the testing error as reflected in the difference between the same eye tested twice (0.7 dB). The authors provide the mathematical basis for recognizing that a right eye-left eye difference in mean sensitivity might be abnormal. Additional information is needed about the variance of the right eye-left eye difference in the population at large, but present information suggests that a 2-dB difference may be meaningful on a single examination. A 1.5-dB difference is statistically significant if confirmed on a second test, and a difference as small as 1 dB may be meaningful if shown consistently in a series of four examinations. In all cases, nonglaucomatous causes of field abnormality needs to be ruled out, and the generalized asymmetry is most meaningful if it is consistent with asymmetry of cupping or intraocular pressure. Several cases are reported in which a mild (1 dB) generalized depression of the visual field is the only recognizable abnormality in the visual field in eyes with early glaucoma.

Adult↗

Possibly reduced prevalence of peripapillary crescents in ocular hypertension.

We studied optic disc photographs from 137 healthy subjects and 195 subjects with ocular hypertension. The prevalence of peripapillary crescents was lower among hyperopes than among myopes (p less than 0.05). Moreover, the ocular hypertensive subjects had a statistically significant tendency toward a hyperopic median refraction (p less than 0.01). In keeping with this, we observed a lower prevalence rate of crescents in the ocular hypertensive group (35%) than among the healthy subjects (41%). This difference is in the expected direction and magnitude if the absence of a crescent decreases the risk of glaucomatous damage from elevated intraocular pressure, but the number of subjects was too small to obtain statistical significance; however, the evidence is suggestive. Further study, such as in a large population survey or by comparison of two groups with matched genetic heritage, is needed to substantiate the relation between the presence of a crescent and increased risk of glaucomatous damage.

Female↗

The influence of simulated light scattering on automated perimetric threshold measurements.

The effect of light scattering by ocular media opacities on OCTOPUS and Humphrey perimeter threshold measurements was simulated with randomly ordered sequences of six ground-glass diffusers in the right eyes of five subjects. Threshold measurements were performed at 0 degrees, 5 degrees, 10 degrees, 15 degrees, 20 degrees, and 25 degrees nasally along the 180 degrees meridian with the F4 program on an OCTOPUS perimeter, and with twice-repeated profiles on a Humphrey perimeter. The reduction in differential light sensitivity correlated well with the 2.7-dB to 16.7-dB reduction in stimulus intensity caused by the 46% to 98% scattering of incident light by the diffusers. Contrast sensitivity in the presence of a glare source (Miller-Nadler glare test) was also affected by the diffusers, such that a 75% contrast target was not visible through the strongest diffuser whereas a 5% contrast target was visible without a diffuser. Conversely, the diffusers had very little effect on visual acuity measurements that were performed with projected high-contrast targets in a darkened room. Our data suggest that even minimal light scattering, such as might be caused by a cataract that has a relatively insignificant effect on visual acuity, may influence threshold measurements.

Adult↗

The influence of refraction accuracy on automated perimetric threshold measurements.

The effect of refraction accuracy on the differential light threshold of a Goldmann size III (0.43 degrees diameter) stimulus was evaluated in the right eyes of five normal subjects with randomly ordered sequence of plano, +1.00-, +2.00-, +3.00-, +4.00-, +5.00-, and +6.00-diopter (D) spherical overcorrections. Threshold measurements were performed at 0 degree, 5 degrees, 10 degrees, 15 degrees, 20 degrees, and 25 degrees eccentricity nasally along the 180 degrees meridian with the F4 program on the Octopus 201 perimeter. The +1.00- through +6.00-D overcorrections decreased the threshold values by an average of 1.4, 2.9, 4.2, 5.6, 6.7, and 7.6 dB, respectively, compared with the plano overcorrection. The depression of the differential light threshold was of similar magnitude at all eccentricities within the central 25 degrees.

Adult↗

Accommodation of an endocapsular silicone lens (Phaco-Ersatz) in the nonhuman primate.

In owl monkeys, as a model of endocapsular cataract extraction, the lens material was removed through a small hole in the capsule and was replaced with a silicone polymeric gel. The ability of this endocapsular implant (Phaco-Ersatz) to accommodate was documented when pilocarpine produced an increase in the curvature of the lens surface and a decrease in the anterior chamber depth, just as occurs with the untouched natural lens. Refinements of the surgical technique are required to achieve a controlled degree of filling of the capsular bag and inhibit postoperative epithelial proliferation on the inner capsular surface.

Accommodation, Ocular↗

Rebleeding after traumatic hyphema.

We reviewed the medical records of 175 patients who were admitted between 1977 and 1984 with a diagnosis of traumatic hyphema to define the incidence of operative intervention for the treatment of complications related to rebleeding. Of the 156 patients admitted with primary hyphemas, 25 (16%) rebled during hospitalization. Seven of these 25 in-hospital rebleeds required surgical intervention. Nineteen other patients were admitted with ocular histories and examinations strongly suggestive of rebleeding prior to admission (secondary hyphema--presumed preadmission rebleed). Seven of these 19 eyes underwent surgery. Of the 175 eyes studied, only one eye that did not rebleed underwent surgery during the initial hospitalization. Fourteen (32%) of 44 eyes that rebled underwent operative intervention. Nine of these 14 patients were operated on under general anesthesia. Potential benefits of newer hyphema treatments, such as epsilon-aminocaproic acid, designed to prevent rebleeding should be weighed against not only the ocular risks of rebleeding but also the risks of general anesthesia.

Adolescent↗

Echography of retinoblastoma: histopathologic correlation and serial evaluation after globe-conserving radiotherapy or chemotherapy.

PURPOSE: To assess the sensitivity of echography in detecting retinoblastoma, compare tumor features observed by echography with histopathology data, and assess the usefulness of echography in serially following retinoblastoma tumors after globe-conserving treatments. METHODS: The medical and echography records of all patients treated for retinoblastoma at the Bascom Palmer Eye Institute between 1991 and 1997 were reviewed. All eyes underwent pretreatment echographic evaluation, and eyes treated with external beam radiotherapy, brachytherapy, or chemotherapy underwent serial follow-up echography. RESULTS: Sixty-nine eyes of 48 patients were identified. Echography demonstrated evidence of retinoblastoma in 69 of 69 (100%) eyes and calcification in 63 (91.3%) eyes. Histopathology was superior to echography in detecting optic nerve invasion, extraocular extension, and presence of calcification. CONCLUSION: Echography is a useful adjunct to indirect ophthalmoscopy in establishing the diagnosis of retinoblastoma. While not as specific as histopathology, echographic evaluation before and after treatment of retinoblastoma permits monitoring of treatment response and may aid in detecting recurrent tumor growth or failure to respond to treatment.

Brachytherapy↗