Search PubMed⌕ Search

Biomedical subjects

W Hu

Publications and source records attributed to W Hu.

At least 55 records · Page 3Linked to original sources

High-performance ion-exclusion/cation-exchange chromatography of anions and cations in acid rain waters on a weakly acidic cation-exchange resin.

A new method for the simultaneous determination of anions (sulfate, nitrate, and chloride) and cations (sodium, ammonium, potassium, magnesium, and calcium) in acid rain waters was investigated using high-performance ion-exclusion/cation-exchange chromatography with conductimetric detection on a separation column packed with a polymethacrylate-based weakly acidic cation-exchange resin in the hydrogen-form and an eluent comprising 1.5 mM sulfosalicylic acid-6 mM 18-crown-6 at pH 2.6, operated at 1.5 ml/min. Effective separation and highly sensitive conductimetric detection for the anions and the cations was achieved in about 14 min. Since the ionic balance (equivalents of anions/equivalents of cations) of acid rain waters of different pH (4.40-4.67) ranged from 0.97 to 0.94, evaluation of the water quality of acid rain was possible. This method was successfully applied to the simultaneous determination of the anions and the cations in acid rain transported from mainland China and North Korea to central Japan monitored by a meteorological satellite data analyzer.

Acid Rain↗

Beam propagation of x rays in a laser-produced plasma and a modified relation of interferometry in measuring the electron density.

In this paper, using a quantum mechanical technique and introducing the so-called V representation (where the representation transformation is made by using the potential Hamiltonian V), we studied x-ray propagation in a linear plasma medium both analytically and numerically. A modified relation between the phase of the probe and the reference light and the electron density of the plasma is derived, in which the contribution of the gradient of the electron density has been taken into account. It is shown that this relation has the advantage in measurements of the electron density of a plasma using the x-ray interferometry technique of lessening the errors originating from the electron density gradient. The validity of x-ray interferometry is discussed in both mathematical and physical terms.

Journal Article↗

Molecular dissection of the importin beta1-recognized nuclear targeting signal of parathyroid hormone-related protein.

Produced by various types of solid tumors, parathyroid hormone-related protein (PTHrP) is the causative agent of humoral hypercalcemia of malignancy. The similarity of PTHrP's amino-terminus to that of parathyroid hormone enables it to share some of the latter's signalling properties, but its carboxy-terminus confers distinct functions including a role in the nucleus/nucleolus in reducing apoptosis and enhancing cell proliferation. PTHrP nuclear import occurs via a novel importin beta1-mediated pathway. The present study uses several different direct binding assays to map the interaction of PTHrP with importin beta using a series of alanine mutated PTHrP peptides and truncated human importin beta1 derivatives. Our results indicate that PTHrP amino acids 83-93 (KTPGKKKKGK) are absolutely essential for importin beta1 recognition with residues 71-82 (TNKVETYKEQPL) additionally required for high affinity binding; residues 380-643 of importin beta1 are required for the interaction. Binding of importin beta1 to PTHrP is reduced in the presence of the GTP-bound but not GDP-bound form of the guanine nucleotide binding protein Ran, consistent with the idea that RanGTP binding to importin beta is involved in the release of PTHrP into the nucleus following translocation across the nuclear envelope. This study represents the first detailed examination of a modular, non-arginine-rich importin beta1-recognized nuclear targeting signal.

Active Transport, Cell Nucleus↗

Mutational analysis of chicken interleukin 2.

Chicken interleukin 2 (chIL-2) has low, but significant, homology to both mammalian IL-2 and mammalian IL-15. In view of its unique phylogenetic position and potential use as a vaccine adjuvant, a detailed mutational analysis for critical functional sites was undertaken. It was found that Asp17 is a critical N terminal contact site for binding to the putative chIL-2 receptor, which is similar to results obtained for mammalian IL-2 and IL-15. Analysis of the C terminus did not reveal a single critical amino acid. However, deletion mutant studies demonstrated that removal of C terminal amino acids yielded proteins with decreased bioactivity and that this decrease was a function of the number and kind of amino acids removed. This study is the first non-mammalian IL-2 mutational analysis and proposes a model for the interaction between chIL-2 and its receptor.

Alanine↗

Multiple endocytic signals in the C-terminal tail of the cystic fibrosis transmembrane conductance regulator.

The cystic fibrosis transmembrane conductance regulator (CFTR) is a cAMP-dependent protein kinase (PKA)-activated chloride channel that is localized to the plasma membrane and endosomal compartment. Endosomal targeting of CFTR is attributed to the Tyr(1424)-based internalization signal, identified in the C-terminal tail of the channel. Mutation of the Tyr(1424) residue could partly inhibit the endocytosis of CFTR and its association with the adapter protein AP-2. To reveal additional endosomal targeting signals, site-directed mutagenesis of both a chimaera, composed of a truncated form of interleukin 2 receptor alpha chain (TacT) and the C-terminal tail of CFTR (Ct), and the full-length CFTR was performed. Morphological and functional assays revealed the presence of multiple internalization motifs at the C-terminus, consisting of a phenylalanine-based motif (Phe(1413)) and a bipartite endocytic signal, comprising a tyrosine (Tyr(1424)) and a di-Leu-based (Leu(1430)-Leu) motif. Whereas the replacement of any one of the three internalization motifs with alanine prevented the endocytosis of the TacT-Ct chimaera, mutagenesis of Phe(1413)-Leu impaired the biosynthetic processing of CFTR, indicating that Phe(1413) is indispensable for the native structure of CFTR. In contrast, replacement of Leu(1430)-Leu- and Tyr(1424)-based signals with alanine increased the cell-surface density of both the chimaeras and CFTR in an additive manner. These results suggest that the internalization of CFTR is regulated by multiple endocytic sorting signals.

Amino Acid Motifs↗

Determination of hydrogen ion by ion chromatography (IC) with sulfonated cation-exchange resin as the stationary phase and aqueous EDTA (ethylenediamine-N,N,N',N'-tetraacetic acid) solution as the mobile phase.

An ion chromatographic (IC) method has been developed for determination of hydrogen ion (H+). It is based on the use of sulfonated cation-exchange resin as stationary phase, aqueous ethylenediamine-N,N,N',N'-tetraacetic acid (dipotassium salt, EDTA-2K, written as K2H2Y) solution as mobile phase, and conductivity for detection. H+ was separated mainly by cation-exchange, but its elution was accelerated by the presence of EDTA. The order of elution for the model cations was H+ > Li+ > Na+ > NH4+ > Ca2+ > > Mg2+. A sharp and highly symmetrical peak was obtained for H+ and this was attributed to the capacity of H2Y2(2-) to receive and bind H+. H+ was detected conductiometrically and detector response (reduction in conductivity as a result of H+ +H2Y2- --> H3Y-) was linearly proportional to the concentration of H+ in the sample. The detection limit for H+ with this IC system was better than 4.7 micromol L(-1). A significant advantage of this method was the ability to separate and determine, in one step, H+ and other cations. The successful determination of H+ and other cation species in real acid-rain samples demonstrated the usefulness of this method.

Acid Rain↗

Use of zwitterionic micelles in the eluent II: a new approach to ion chromatographic analysis of inorganic cations in biological fluids with direct sample injection.

A new ion chromatographic (IC) technique has been developed for the determination of inorganic cations in biological fluids with direct sample injection. This involved the use of a mixed zwitterionic-micelle/electrolyte solution as an eluent. The proteins in the sample became bound to the zwitterionic micelles in the eluent and were thus eliminated from the column. The cations were separated by cation exchange. This method is ideal for the online, simultaneous determination of common inorganic cations (Na+, NH4+, K+, Mg2+, and Ca2+) in urine and serum samples. Such an application was demonstrated experimentally. Non-suppressed conductivity was used for analyte detection. The detection limits obtained using this IC system were 2.94, 5.22, 34.9, 32.6, and 56.7 microg/L for Na+, NH4+, K+, Mg2+, and Ca2+, respectively.

Cations↗

Determination of inorganic anions in human saliva by zwitterionic micellar capillary electrophoresis.

Capillary electrophoresis (CE) using sulfobetaine-type zwitterionic micelles as the background electrolyte (BGE) has been used to determine inorganic anions in human saliva. The zwitterionic micelles resulted in unique migration behavior for the separation of inorganic anions. They also prevented adsorption of proteins on the inner wall of the capillary. These properties of the zwitterionic micelles enabled the direct determination of inorganic anions in human saliva. Three species of inorganic anions, NO2-, NO3-, and SCN-, were found in real samples and the analysis was achieved within 3 min. Direct UV-absorption was used as the detection method and the detection limits for these anions were 2.0, 1.0, and 5.0 micromol L(-1), respectively (0.09, 0.06, and 0.30 microg mL(-1)).

Anions↗

Determination of inorganic acids by ion chromatography with n-tetradecylphosphocholine (zwitterionic surfactant) as the stationary phase and pure water as the mobile phase.

A new ion chromatographic (IC) system, in which n-tetradecylphosphocholine (TDPC, a phosphobetaine type of zwitterionic surfactant) was used as the stationary phase, pure water as the mobile phase, and conductivity as the method of detection, has been developed for the determination of inorganic acids. Five model acids, HCl, HNO3, HClO4, H2SO4, and H3PO4, were separated to baseline and eluted in the order H3PO4 > HCl > HNO3 > H2SO4 > HClO4. When peak areas were plotted against the concentrations of the acids in samples, linear calibration curves were obtained. Ultimate determination limits were approximately 1 mmol L(-1), but the discrimination of the method between solutions of different concentration was better than 10 micromol L(-1) for those model analytes. Salts of divalent cations could also be separated, but they were eluted faster than the acids. No separation was observed for the salts of monovalent cations. This newly proposed approach is applicable to the simultaneous determination of the inorganic acids (produced by reactions of NOx, SOx, and HCl with water) in aerosols.

Acids↗

Direct determination of nitrite traces in high ionic-strength samples by electrostatic ion chromatography using diluted acid solutions as eluent.

An ion-chromatographic (IC) system with high selectivity for separation of nitrite is described. It is analogous to the EIC (electrostatic IC) previously reported and was established using 3-(N,N-dimethylstearylammonio)propanesulfonate (C23H49NO3S, a sulfobetaine type of zwitterionic surfactants) as the stationary phase and dilute aqueous HCl solutions as the mobile phase. Five inorganic anions, sulfate, chloride, bromide, nitrate, and nitrite were chosen as the model analytes and were analyzed using this EIC system. Sulfate was always eluted first, followed by chloride, bromide and nitrate. Nitrite, however, could be eluted either before or after nitrate, depending on the concentration of HCl in the eluent. An elution order nitrate< nitrite was always obtained simply by using >3 mmol L(-1) HCl as the eluent. For nitrite the detection limit was better than 2.1 x 10(-7) mol L(-1) (100 microL sample injection volume, S/N=3, UV at 210 nm). Bromide and nitrate could also be separated under these HPLC conditions. The detection limit for bromide was 7.2 x 10(-8) mol L(-1) and for nitrate 6.5 x 10(-8) mol L(-1). Both nitrite and nitrate in real seawater samples were successfully determined with direct sample injection using this EIC system.

Acids↗

Screening for cerebellopontine angle tumours: conventional MRI vs T2 fast spin echo MRI.

BACKGROUND: Unilateral audiovestibular symptoms are commonly seen in clinical practice and are rarely caused by retrocochlear pathology. However, clinicians are often required to rule out potentially serious causes of these unilateral symptoms. Gadolinium enhanced magnetic resonance imaging (GdMRI) is the most accurate test for detecting small cerebellopontine angle lesions and also screens the adjacent CNS structures. Its main disadvantage is the cost of the procedure. METHODS: We studied 100 consecutive patients with both GdMRI and a newer MRI screening study utilizing unenhanced T2-weighted fast spin echo (fse) MRI. Acquired images were randomly assessed by a panel of three neuro-radiologists. RESULTS: We found that the screening (fse) MRI was as sensitive and specific when detecting cerebellopontine angle tumors. CONCLUSIONS: We conclude that T2-weighted fse MRI is a safe and cost-effective alternative to GdMRI and offers better diagnostic utility when compared to auditory brain stem response (ABR) and CT scans.

Brain Stem↗

Novel 2D and 3D multiple-quantum bi-directional HCNCH experiments for the correlation of ribose and base protons/carbons in 13C/15N labeled RNA.

Multiple-quantum 2D and 3D bi-directional HCNCH experiments are presented for the correlation of base and ribose protons/carbons in 13C/15N labeled HIV-1 TAR RNA. In both 2D and 3D experiments, the magnetization of H1' is transferred to H6/H8 and H1' through H1'-C1'-N1/9-C6/8-H6/8 and H1'-C1'-N1/9-C1'-H1' pathways, and the magnetization of H6/8 is transferred to H1' and H6/8 through H6/8-C6/8-N1/9-C1'-H1' and H6/8-C6/8-N1/9-C6/8-H6/8 pathways. Chemical shifts of four different nuclei (H1', C1', C6/8 and H6/8) are sampled in the 2D experiment. The correlation of base and ribose protons/carbons is established by the rectangular arrangement of crossover and out-and-back peaks in the proton/carbon correlated spectrum. The rectangular connections can be further resolved using the nitrogen dimension in a 1H/13C/15N 3D experiment. Furthermore, by taking advantage of the well separated chemical shifts of N1 (pyrimidine) and N9 (purine), the 2D spectrum can be simplified into two sub-spectra based on their base type. Both experiments were tested on a 13C/15N labeled 27-mer HIV-1 TAR RNA containing a UUCG hairpin loop.

Carbon Isotopes↗

Peptide-triggered conformational switch in HIV-1 RRE RNA complexes.

We have used NMR spectroscopy to determine the solution structure of a complex between an oligonucleotide derived from stem IIB of the Rev responsive element (RRE-IIB) of HIV-1 mRNA and an in vivo selected, high affinity binding Arg-rich peptide. The peptide binds in a partially alpha-helical conformation into a pocket within the RNA deep groove. Comparison with the structure of a complex between an alpha-helical Rev peptide and RRE-IIB reveals that the sequence of the bound peptide determines the local conformation of the RRE peptide binding site. A conformational switch of an unpaired uridine base was revealed; this points out into the solvent in the Rev peptide complex, but it is stabilized inside the RNA deep groove by stacking with an Arg side chain in the selected peptide complex. The conformational switch has been visualized by NMR chemical shift mapping of the uridine H5/H6 atoms during a competition experiment in which Rev peptide was displaced from RRE-IIB by the higher affinity binding selected peptide.

Amino Acid Sequence↗

Simultaneous ion-exclusion chromatography and cation-exchange chromatography of anions and cations in environmental water samples on a weakly acidic cation-exchange resin by elution with pyridine-2,6-dicarboxylic acid.

A non-suppressed conductivity detection ion chromatographic method using a weakly acidic cation-exchange column (Tosoh TSKgel OApak-A) was developed for the simultaneous separation and determination of common inorganic anions (Cl-, NO3- and SO4(2-)) and cations (Na+, NH4+, K+, Mg2+ and Ca2+). A satisfactory separation of these anions and cations on the weakly acidic cation-exchange column was achieved in 25 min by elution with a mixture of 1.6 mmol L-1 pyridine-2,6-dicarboxylic acid and 8.0 mmol L-1 18-crown-6 at flow rate of 1.0 mL min-1. On this weakly acidic cation-exchange resin, anions were retained by an ion-exclusion mechanism and cations by a cation-exchange mechanism. The linear range of the peak area calibration curves for all analytes were up to two orders of magnitude. The detection limits calculated at S/N = 3 ranged from 0.25 to 1.9 mumol L-1 for anions and cations. The ion-exclusion chromatography-cation-exchange chromatography method developed in this work was successfully applied to the simultaneous determination of major inorganic anions and cations in rainwater, tap water and snow water samples.

Chromatography, Ion Exchange↗