Search PubMed⌕ Search

Biomedical subjects

W Heinrichs

Publications and source records attributed to W Heinrichs.

At least 19 recordsLinked to original sources

[Combined simulation training: a new concept and workshop is useful for crisis management in gastrointestinal endoscopy].

INTRODUCTION: Crisis management as well as realistic emergency situations can be trained in the new developed simulation workshop "Gastrointestinal Endoscopy and Crisis Resource Management" by combining a full-scale simulator and the Erlanger Endoscopy Trainer. The aim of the current study was to evaluate the efficiency of the newly developed simulation workshop. METHODS: Endoscopists with more than 12 months experience can train their endoscopic skills and crisis resource management with the help of different simulators. In addition, two different scenarios (GI bleeding with significant blood loss and sedation overdoses) embedded in a realistic surrounding (emergency room) have to be managed by the participants. Vital parameters, endoscopic skills, as well as personal interactions were recorded and graded. RESULTS: 100 participants took part in the newly developed workshop (between June and December 2003). The participants showed a significantly better endoscopic performance and a significantly better crisis management after the standardized training program. CONCLUSIONS: Simulation training plays an essential role in aviation and minimizes the risk for human errors. In the current study it is clearly shown that simulation training is also useful in gastrointestinal endoscopy. The newly developed workshop may thus be of crucial importance to improve personal crisis management. Simulation also leads to an improvement of endoscopic and emergency skills. Accordingly, simulation training should be recommended or offered as an education option in gastrointestinal endoscopy.

Computer-Assisted Instruction↗

High-frequency oscillatory ventilation and an interventional lung assist device to treat hypoxaemia and hypercapnia.

A male patient accidentally aspirated paraffin oil when performing as a fire-eater. Severe acute respiratory distress syndrome (Pa(o(2))/Fi(o(2)) ratio 10.7 kPa) developed within 24 h. Conventional pressure-controlled ventilation (PCV) with high airway pressures and low tidal volumes failed to improve oxygenation. Hypercapnia (Pa(co(2)) 12 kPa) with severe acidosis (pH<7.20) ensued. Treatment with high-frequency oscillatory ventilation (HFOV) and a higher adjusted airway pressure (35 cm H(2)O) improved the Pa(o(2))/Fi(o(2)) ratio within 1 h from 10.7 to 22.9 kPa, but the hypercapnia and acidosis continued. Stepwise reduction of the mean airway pressure (26 cm H(2)O), and oscillating frequencies (3.5 Hz), as well as increasing the oscillating amplitudes (95 cm H(2)O) resulted in an unchanged Pa(co(2)), but oxygenation worsened. The new pumpless extracorporeal interventional lung assist device (ILA, NovaLung, Hechingen, Germany) was therefore used for carbon dioxide elimination to enable a less aggressive ventilation strategy. Pa(co(2)) normalized after initiation of ILA. HFOV with a mean airway pressure of 32 cm H(2)O was maintained, but with a higher oscillatory frequency (9 Hz) and very low oscillatory amplitude (25 cm H(2)O). After 6 days, the patient was transferred to a conventional ventilator, and ILA was discontinued after 13 days without complications.

Adult↗

Gastric insufflation pressure, air leakage and respiratory mechanics in the use of the laryngeal mask airway (LMA) in children.

BACKGROUND: The objective of the present study was to evaluate the prelaryngeal position of the laryngeal mask airway (LMA(TM)) in children, and to determine the influence of mask positioning on gastric insufflation and oropharyngeal air leakage. METHODS: A total of 100 children, 3-11 years old, scheduled for surgical procedures in the supine position under general anaesthesia were studied. After clinically satisfactory LMA placement, tidal volumes were increased stepwise until air entered the stomach, airway pressure exceeded 30 cmH(2)O, or air leakage from the mask seal prevented further increases in tidal volume. LMA position in relation to the laryngeal entrance was verified using a flexible bronchoscope. RESULTS: The insertion of the LMA with a clinically satisfactory position was achieved in all patients at the first attempt. Gastric air insufflation occurred in five of 49 patients with malpositioned LMA. No incident of gastric air insufflation was observed in 51 patients with correctly positioned LMA. The minimum inspiratory pressure leading to mask leakage was 17 cmH(2)O for incorrectly positioned LMA, and 25 cmH(2)O for correctly positioned LMA. Clinically unrecognized LMA malposition was associated with a significantly increased incidence of either oropharyngeal leakage (r = 0.59; P = 0.0001) or gastric insufflation (r = 0.25; P = 0.01). CONCLUSIONS: Clinically undetected LMA malpositioning is a significant risk factor for gastric air insufflation in children between 3 and 11 years, undergoing positive pressure ventilation, especially at inspiratory airway pressures above 17 cmH(2)O.

Air↗

Intention tremor, parkinsonism, and generalized brain atrophy in male carriers of fragile X.

The authors report five elderly men with the fragile X premutation who had a progressive action tremor associated with executive function deficits and generalized brain atrophy. These individuals had elevated fragile X mental retardation 1 gene (FMR1) messenger RNA and normal or borderline levels of FMR1 protein. The authors propose that elevations of FMR1 messenger RNA may be causative for a neurodegenerative syndrome in a subgroup of elderly men with the FMR1 premutation.

Aged↗

Temporal dynamics of lung aeration determined by dynamic CT in a porcine model of ARDS.

We used dynamic CT to identify two different time constants of lung aeration and their individual contribution to the total increase in cross-sectional lung area in healthy and experimentally damaged lungs. In five healthy pigs, inflation and deflation between 0 and 50 cm H2O was imposed during dynamic (250 ms/image) CT acquisition, and repeated after experimental lung injury by saline lavage. The fractional areas of density ranges, which represent aerated lung parenchyma, were determined planimetrically, and their time for expansion during the manoeuvre was fitted using a bi-exponential model. Thus, two compartments, their sizes, i.e. their relative contributions to lung area aerated by the manoeuvre, and their specific time constants (tau) were sought. Healthy lungs were characterized best by a one-compartmental behaviour with one tau only, both during inflation (median tau=0.5 s; range 0.4-0.6 s) and deflation (1.2 s; 1.1-1.3 s). In damaged lungs two compartments were found both during inspiration and expiration, with 86% (78-87%) of the recruitable lung area following a short tau of 0.5 s (0.5-0.6), and 14% (13-22%) following a longer tau of 9.1 s (8-16.8 s) during inflation. During expiration, damaged lungs had a short tau of 0.8 s (0.5-1.0 s) for 94% (84-100%) of deflated lung area, and a longer tau of 26.5 s (7.1-34.3 s) for 6% (0-16%). We conclude that dynamic CT indicates the relative size and temporal behaviour of functional compartments in normal and abnormal lungs. Our findings suggest that after lung damage, cyclic ventilation with inspiratory periods of <10 s duration will not achieve maximum recruitment for a chosen inspiratory pressure. In ARDS, the short expiratory tau predisposes to atelectasis formation if expiratory times are >1 s.

Animals↗

Component analysis of verbal fluency in patients with schizophrenia.

OBJECTIVE: Clustering and-switching components of phonemic fluency performance were compared in patients with schizophrenia and healthy normal controls. BACKGROUND: These components were selected to provide evidence for a specific anatomic locus for the breakdown of language processes or for a multiple-disease model of schizophrenia. METHOD: As part of a larger battery of neuropsychological tests, phonemic fluency tests were administered on an individual basis. On separate 60-second trials, participants were instructed to generate words beginning with the letters C, F, and L, excluding proper names and variants of the same word. Three scores were obtained for each participant: (1) number of words generated, excluding errors and repetitions; (2) mean cluster size; and (3) raw number of switches. RESULTS: The patients showed small but significant impairments in clustering and larger impairments in switching relative to normal controls. CONCLUSIONS: This pattern suggests a relatively greater deficit in functioning in the frontal lobe than in the temporal lobe. However, neither measure was able to completely discriminate patients with schizophrenia from controls. Moreover, differences in fluency performance were observed among subtypes of schizophrenia. Taken together, the findings of impaired performance for both aspects of fluency, differences between subtypes, and the failure to completely discriminate patients with schizophrenia from controls indicate that there is not a single marker of the disease, at least among these fluency variables. Instead, the current findings are more supportive of a multiple-disease model of schizophrenia.

Adult↗

Successful treatment of a patient with ARDS after pneumonectomy using high-frequency oscillatory ventilation.

High frequency oscillatory ventilation (HFOV) was used in a patient who developed the acute respiratory distress syndrome 5 days following a right pneumonectomy for bronchogenic carcinoma. When conventional pressure-controlled ventilation failed to maintain adequate oxygenation, HFOV dramatically improved oxygenation within the first few hours of therapy. Pulmonary function and gas exchange recovered during a 10-day period of HFOV. No negative side effects were observed. Early use of HFOV may be a beneficial ventilation strategy for adults with acute pulmonary failure, even in the postoperative period after lung resection.

Airway Resistance↗

Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size.

OBJECTIVES: To determine whether individualized selection of double-lumen tubes or alternatives based on three-dimensional reconstruction of the tracheobronchial image from routine preoperative computed tomography (CT) scans leads to clinically appropriate choices. DESIGN: Prospective observational study; comparison to historic controls. SETTING: Anesthesia and radiology facilities of a university medical center. PARTICIPANTS: Forty-nine patients undergoing thoracic surgery requiring one-lung ventilation. INTERVENTIONS: Three-dimensional image reconstruction of individual tracheobronchial anatomy was performed from routine preoperative spiral CT scans as well as from scans of five left-sided and four right-sided double-lumen tubes. Results of image-based tube size selection were compared with literature recommendations. Prospectively, individualized tube selection was performed by superimposition of printed transparencies of tubes over the tracheobronchial system and was validated using bronchoscopic and clinical criteria (n = 24). MEASUREMENTS AND MAIN RESULTS: Three-dimensional reconstruction visualized individual anatomy with good accuracy and resolution. Correlations between patient morphology and tracheobronchial dimensions were weak (height versus mainstem bronchial diameters: r < 0.50). In 11 of 48 patients (23%). CT-fitted double-lumen tube sizes would have differed from a conventional height-based and gender-based selection. Individual, prospective, CT-based double-lumen tube selection was associated with (1) good fit and positioning confirmed by fiberoptic bronchoscopy, (2) adequate bronchial cuff seal volumes, (3) complete lung separation, and (4) oxygenation and ventilation parameters during one-lung ventilation similar to those with conventional size selection. In one patient, three-dimensional CT study allowed noninvasive evaluation of a tracheal stenosis precluding double-lumen tube placement. CONCLUSION: Individualized selection of double-lumen tube size using CT-based reconstructions of tracheobronchial anatomy leads to clinically appropriate choices. Risks resulting from variations in tracheobronchial morphology are recognized in advance.

Adolescent↗

[Multi-rotation CT during continuous ventilation: comparison of different density areas in healthy lungs and in the ARDS lavage model].

PURPOSE: In this animal study, density ranges for CT-based quantification of ventilated lung area were determined. Healthy lungs and ARDS lungs were compared during artificial respiration. MATERIAL AND METHODS: CT-scans were performed in 5 anesthetized pigs using a dynamic multiscan CT option on a predefined transverse slice (slice thickness 1 mm; effective temporal resolution, 250 ms). During continuous CT acquisition, airway pressure was increased or decreased in a stepwise manner. In all images, areas of defined HU ranges were determined planimetrically. The lower threshold was set to -910 HE in all images. The upper threshold was varied from -800 HE to -200 HE in steps of 100 HE. RESULTS: During inspiration in healthy lungs the HU-range of -910 to -700 HU showed the largest increase in area. During inspiration in ARDS lungs the HU range from -910 to -300 HU allowed the most sensitive assessment of area changes. These findings can be explained by recruitment of atelectases (HU-range > -300 HU) and their transition to a HU range from -700 to -300 HU. CONCLUSION: Dynamic multiscan CT acquisitions are a useful method to determine changes of ventilated lung area during a respiratory cycle. Different HU-ranges are required to access volume changes in healthy lungs and in ARDS lungs.

Animals↗

Adaptive lung ventilation (ALV) during anesthesia for pulmonary surgery: automatic response to transitions to and from one-lung ventilation.

UNLABELLED: Adaptive lung ventilation is a novel closed-loop-controlled ventilation system. Based upon instantaneous breath-to-breath analyses, the ALV controller adjusts ventilation patterns automatically to momentary respiratory mechanics. Its goal is to provide a preset alveolar ventilation (V'A) and, at the same time, minimize the work of breathing. Aims of our study were (1) to investigate changes in respiratory mechanics during transition to and from one-lung ventilation (OLV), (2) to describe the automated adaptation of the ventilatory pattern. METHODS: With institutional approval and informed consent, 9 patients (33-72 y, 66-88 kg) underwent ALV during total intravenous anesthesia for pulmonary surgery. The ALV controller uses a pressure controlled ventilation mode. V'A is preset by the anesthesiologist. Flow, pressure, and CO2 are continuously measured at the DLT connector. The signals were read into a IBM compatible PC and processed using a linear one-compartment model of the lung to calculate breath-by-breath resistance (R), compliance (C), respiratory time constant (TC), serial dead space (VdS) and V'A. Based upon the results, the controller optimizes respiratory rate (RR) and tidal volume (VT) such as to achieve the preset V'A with the minimum work of breathing. In addition to V'A, only PEEP and FIO2 settings are at the anesthesiologist's discretion. All patients were ventilated using FIO2 = 1,0 and PEEP = 3 cm H2O. Parameters of respiratory mechanics, ventilation, and ABG were recorded during three 5-min periods: 10 min prior to OLV (1), 20 min after onset of OLV (II), and after chest closure (III). Data analyses used nonparametric comparisons of paired samples (Wilcoxon, Friedman) with Bonferroni's correction. Significance was assumed at p < 0.05. Values are given as medians (range). RESULTS: 20 min after onset of OLV (II), resistance had approximately doubled compared with (1), compliance had decreased from 54 (36-81) to 50 (25-70) ml/cm H2O. TC remained stable at 1.4 (0.8-2.4) vs. 1.2 (0.9)-1.6) s. Institution of OLV was followed by a reproducible response of the ALV controller. The sudden changes in respiratory mechanics caused a transient reduction in VT by 42 (8-59)%, with RR unaffected. In order to reestablish the preset V'A, the controller increased inspiratory pressure in a stepwise fashion from 18 (14-23) to 27 (19-39) cm H2O, thereby increasing VT close to baseline (7.5 (6.6-9.0) ml/kg BW vs. 7.9 (5.4-11.7) ml/kg BW). The controller was, thus, effective in maintaining V'A. The minimum PaO2 during phase II was 101 mmHg. After chest closure, respiratory mechanics had returned to baseline. CONCLUSIONS: Respiratory mechanics during transition to and from OLV are characterized by marked changes in R and C into opposite directions, leaving TC unaffected. The ALV controller manages these transitions successfully, and maintains V'A reliably without intervention by the anesthesiologist. VT during OLV was found to be consistently lower than recommended in the literature.

Adult↗

Laryngeal mask airway position and the risk of gastric insufflation.

UNLABELLED: A potential risk of the laryngeal mask airway (LMA) is an incomplete mask seal causing gastric insufflation or oropharyngeal air leakage. The objective of the present study was to assess the incidence of LMA malpositions by fiberoptic laryngoscopy, and to determine their influence on gastric insufflation and oropharyngeal air leakage. One hundred eight patients were studied after the induction of anesthesia, before any surgical manipulations. After clinically satisfactory LMA placement, tidal volumes were increased stepwise until air entered the stomach, airway pressure exceeded 40 cm H2O, or air leakage from the mask seal prevented further increases in tidal volume. LMA position in relation to the laryngeal entrance was verified using a flexible bronchoscope. The overall incidence of LMA malpositions was 40% (43 of 108). Gastric air insufflation occurred in 19% (21 of 108), and in 90% (19 of 21) of these patients, the LMA was malpositioned. Oropharyngeal air leakage occurred in 42%, and was independent of LMA position. We conclude that clinically unrecognized LMA malposition is a significant risk factor for gastric air insufflation. IMPLICATIONS: Routine placement of laryngeal mask airways does not require laryngoscopy. In our study, fiberoptic verification of mask position revealed suboptimal placement in 40% of cases. Such malpositioning considerably increased the risk of gastric air insufflation.

Adult↗

[Automated anesthesia record systems].

The introduction of electronic anaesthesia documentation systems was attempted as early as in 1979, although their efficient application has become reality only in the past few years. The advantages of the electronic protocol are apparent: Continuous high quality documentation, comparability of data due to the availability of a data bank, reduction in the workload of the anaesthetist and availability of additional data. Disadvantages of the electronic protocol have also been discussed in the literature. By going through the process of entering data on the course of the anaesthetic procedure on the protocol sheet, the information is mentally absorbed and evaluated by the anaesthetist. This information may, however, be lost when the data are recorded fully automatically-without active involvement on the part of the anaesthetist. Recent publications state that by using intelligent alarms and/or integrated displays manual record keeping is no longer necessary for anaesthesia vigilance. The technical design of automated anaesthesia records depends on an integration of network technology into the hospital. It will be appropriate to connect the systems to the internet, but safety requirements have to be followed strictly. Concerning the database, client server architecture as well as language standards like SQL should be used. Object oriented databases will be available in the near future. Another future goal of automated anaesthesia record systems will be using knowledge based technologies within these systems. Drug interactions, disease related anaesthetic techniques and other information sources can be integrated. At this time, almost none of the commercially available systems has matured to a point where their purchase can be recommended without reservation. There is still a lack of standards for the subsequent exchange of data and a solution to a number of ergonomic problems still remains to be found. Nevertheless, electronic anaesthesia protocols will be required in the near future. The advantages of accurate documentation and quality control in the presence of careful planning outweight cost considerations by far.

Anesthesia↗