Search PubMed⌕ Search

Biomedical subjects

W Hauser

Publications and source records attributed to W Hauser.

At least 37 records · Page 2Linked to original sources

[Dynamic measurement of pressure distribution with flexible measuring mats--an innovative measuring procedure in sports orthopedics and traumatology. Development--use--value].

The results of this study provide the basis for an on-target use of measurement of pressure distribution with flexible mats in sports orthopaedics and traumatology and adjacent overlapping fields. Dynamic measurement of pressure distribution using a flexible mat as a capacitor can yield valuable additional information not available so far in this form, on the static and dynamic stress acting on the human locomotor system. In the future this method can be used to prevent injuries and to optimise performance in many disciplines of sport and will make a significant contribution to optimised treatment concepts with pressure-adjusted shoes or insoles, as well as to the control of functional surgery results in traumatology. The fundamentals are presented via a detailed description of the development, standardization and testing of this innovative measuring method. The questions of applicability, practicability and information supplied are discussed on the basis of extensive studies on reproducibility, on the amount of time and technical effort required for each measurement, and on a critical comparison with other methods. For the two fields of application presented here it was possible to standardize the working procedure enabling a largely problem-free application in practice. The first useful results were obtained in sports orthopaedics (alpine ski boots and sportshoe design). By applying the measuring of pressure distribution in alpine ski sports the influence the construction of ski boots on the stress exercised on the human leg could be objectively quantified in man for the first time. Marked differences were found between models where the heel can be turned down on entering, to conventionally fastened ski boots. This, as well as the results on the influence temperature, height of shaft and shaft stability or rigidity on the pressure distribution along the tibia, provide the basis for a new guideline for the testing of ski boots. A new method was developed for the quality testing of shoes, insoles and sport shoes. This method enables for the first time dynamic pressure measurements inside the shoe and under the foot within the shoe. First results have been obtained with different insoles and arch supports or instep-raisers, or with different shoe constructions in general. These results are discussed in respect of their importance for an assessment of the stress exercised on the human body, for a timely detection of unfavourable stress distribution, and for optimizing the performance by means of selecting the appropriate material and suitable design and construction.

Athletic Injuries↗

The College of American Pathologists Phantom Series--an assessment of current nuclear imaging capabilities.

Twelve sets of emission phantoms were distributed semiannually to laboratories of nuclear medicine from 1973 through 1978. This survey aimed to create a national peer group within which it might become possible to compare and standardize nuclear imaging technics, and to evaluate and define the current state of the art in a clinical setting. Results were analyzed in terms of sensitivity (percentage of true-positives), nonspecificity (percentage of false-positives), and performance indices (true-positive/false-negative ratios) for conventional gamma cameras and for rectilinear scanners. The chief determinants of target detectability proved to be target-to-surface depth, target diameter, and intrinsic target contrast. Operational variables and instrument type produced relatively minor effect upon subscriber performance. Gamma cameras tended to show slightly more sensitivity than rectilinear scanners, but were somewhat troubled by nonspecificity. Improvements in the intrinsic resolution of second- and third-generation gamma cameras increasingly employed since 1975 showed negligible impact on performance indices. A consideration of the overall survey performance indices. A consideration of the overall survey performance permits the beginning of a quantitative estimate of current detection capability in day-to-day nuclear imaging.

Evaluation Studies as Topic↗

Therapeutic effects of the bis-pyridinium salts HGG-12, HGG-42, and atropine, benactyzine in organophosphate poisoning of dogs.

Therapeutic properties of various combinations of the bispyridinium salts HGG-12 and HGG-42 against soman and sarin poisoning were investigated in male beagles. Best therapeutic efficiency was shown by HGG-42 in a dosage of 30 muMol/kg. Also good effects were produced by the combination of both oximes in a low dosage of 3 muMol/kg for each one. In soman poisoning no significant reactivation of cholinesterase in serum or erythrocytes was observed.

Animals↗

Results of the 1972 CAP/NBS study of radionuclide measurements.

In 1972 a pilot study was carried out to evaluate radioactivity assay procedures for in-vivo administration in nuclear medicine. The plan was to determine the accuracy with which a measured quantity of radioactivity can be administered to a patient. Delivered samples were returned to the National Bureau of Standards by 33 participants. The activity values of 47% of the participants were within plus or minus 10% and 81% were within plus or minus 20% of the activity value of the samples subsequently measured by the National Bureau of Standards. The analysis of the variability indicated that many of the difficulties encountered by the participants were due to two factors outside their control: differences in assay values of chromium-51 between radiopharmaceutical companies and poor calibration or instruction by the manufacturers of dose calibrators.

Chromium Radioisotopes↗