The effect of density on the 10MV photon beam penumbra.

An investigation into the density dependence of the penumbra of the Varian Clinac 18/10 10MV photon beam has been carried out. A water/lung phantom was constructed of polystyrene (r = 1.04 g cm-3) and cork (r = 0.23 g cm-3), in which interfaces exist both parallel and perpendicular to the beam axis. The irradiation of the phantom was also simulated using the EGS4 Monte Carlo system with a cartesian voxel geometry. Experimental (TLD) and Monte Carlo dose profiles are in close agreement, and show a large degree of penumbral broadening in the lung region. This broadening is due primarily to lateral electronic disequilibrium occurring at a larger distance from the geometric beam edge in lung than in water. This disequilibrium can also cause the dose in lung to drop below the dose in water at the same depth and off axis distance, even though the radiological depth is less in lung. Monte Carlo simulations were also performed where the dose is separated into primary and scattered components, for homogeneous media of densities 0.25, 0.50, 0.75 and 1.00 g cm-3. The penumbral width of the primary dose profile was found to be almost constant with depth for a point source of photons (after the initial build-up region), where the lateral distances from the 95-50% and 50-5% dose levels on the dose profile (normalised to the dose at the central axis) are equal in all cases. Also, primary penumbra width was found to be almost inversely proportional to density. The primary penumbra for a unit density material can be fitted accurately by an exponential forming function with empirical determined coefficients. The penumbral shape for the lower densities can then be closely fitted by scaling the coefficients in proportion to density. This scaling method has application in treatment planning, where the predicted primary penumbra shape should take account of inhomogeneities, and is particularly important in matching adjacent fields. When the scattered dose component is added to give the total dose, penumbral width increases because the scattered dose penumbra is wider than that of the primary dose. Also, the inverse proportionality of the penumbra width with density does not hold for the scattered dose. The relative contribution of the scattered dose increases with density. Therefore, the inverse proportionality of penumbra width with density does not hold for the total dose.

Densitometry

Fourier coefficient description of left ventricular shape.

A method of quantifying the shape of the left ventricle of the heart as seen in 2D echocardiograms was developed. It is based on describing the shape in terms of the coefficients a fifth-order trigonometric Fourier series. Such a series has eleven Fourier coefficients which is too large a number for clinical application so pairs of coefficients are combined to give six coefficients (alpha 0, alpha 1, ... , alpha 5). A trial was conducted to test the ability of the coefficient description to classify subjects as having normal right ventricles or ventricles with an apical abnormality. The tests showed that one of the coefficients (alpha 2) was higher for the subjects with an apical abnormality and that this difference increased with exercise. This is as was expected. However, it was found to be difficult to get a reliable estimate of alpha 2 from a single scan of a patient and that it is therefore probably necessary to average data from several scans to obtain a reliable alpha 2 value for a single patient.

Coronary Angiography

Ultrasonic beam-plotting with very small spheres.

A method of pulse-echo ultrasonic beam plotting is described. It differs from traditional pulse-echo beam plotting in that the ultrasonic pulses are scattered off a totally isolated sphere rather than a sphere suspended on a wire. The method also allows extremely small spheres to be used thus providing greater resolution. It is demonstrated that pulse-echo beam plotting using spheres of different size produces different iso-echo amplitude curves.

Transducers

Electron contamination in 4 MV and 10 MV radiotherapy x-ray beams.

A thin window parallel-plate ionization chamber was constructed for dose measurement in the build-up region of high energy radiotherapy photon beams. The chamber is an integral part of a perspex block. The entrance window is 12 microns Melinex foil with a thin aluminium surface. Cavity thickness is 1.45 mm. Surface doses for varying field sizes were found to increase almost linearly with the side length of a square field. The surface dose for a 10x10 cm 4 MV photon beam is 12.1% for an open field and this increases to 14.1% with a polycarbonate block tray in the beam. Similarly for a 10 MV photon beam the surface dose is 10.6% for an open field and this increases to 12.4% with a polycarbonate block tray. The difference between the dose for an open field and a field with a polycarbonate block tray inserted becomes more significant for larger field sizes. Electron contamination depth dose curves are determined for a 4 MV and 10 MV photon beam. This is achieved by subtracting a pure photon beam build-up curve generated by an EGS4 Monte Carlo simulation from the experimental build-up curve. The EGS4 curve is a theoretical, electron contamination free curve. The electron contamination curve (of the 10 MV photon beam) has depth dose characteristics similar to that of a broad low energy electron beam.

Electrons

Beam hardening of 10 MV radiotherapy x-rays: analysis using a convolution/superposition method.

Total and primary polyenergetic dose spread arrays (PDSA) have been generated for a high energy 10 MV radiotherapy photon beam using the electron gamma shower (EGS) Monte Carlo code. By considering the attenuation of fluence per energy interval, PDSA have been produced at radiological depths of 0 cm (the surface PDSA) and 40 cm (the beam hardened PDSA). By comparing primary PDSA produced at these different depths, the effect of beam hardening on the PDSA has been quantified. Calculations show that the mean electron range due to the surface primary PDSA is 6.67 mm and the mean electron range of the beam hardened primary PDSA is 8.24 mm. In comparison, a 3 MeV primary monoenergetic dose spread array (MDSA) has a much smaller mean electron range of 4.81 mm. A radiotherapy x-ray beam computation method is introduced which involves a single superposition of the surface generated PDSA or beam hardened PDSA with a polyenergetic TERMA. The mean percentage difference between depth-dose curves obtained using super-position of surface and beam hardened PDSA is only 0.1%. The mean percentage difference from experimental data for these superposition curves is 2.8% down to 40 cm in a homogeneous phantom. The superposition process is shown to be forgiving to spectral differences when calculating the PDSA, but sensitive to the incident photon energy spectrum used to calculate the TERMA.

Biophysical Phenomena

The production of body analogs for use in radiation physics.

Bone, muscle and lung analog materials have been produced in-house, and dosimetry phantoms have been produced. A method using computed tomography (CT) has been developed to check that the analogs produced match the radiation properties of body tissues. The relative electron densities and ratio of electron cross sections are calculated from elemental compositions of the analogs. Using these data the theoretical CT numbers are calculated and these numbers are compared with experimental CT numbers for the analogs produced. The experimental CT numbers are found by scanning the samples on a Siemens DRH CT scanner. Results show the maximum difference between theoretical and experimental CT numbers for the analogs is 18 Hounsfield units, which relates to a delta NCT of less than 1%. Comparison of analog CT numbers with CT numbers for the related patient tissues also shows a close match.

Body Composition

Superposition dose calculation in lung for 10MV photons.

Currently available radiotherapy treatment planning systems employ scatter function models such as ETAR and Batho dSAR for dose calculation. Errors using these models for high energy photon irradiation occur in and beyond lung tissue for small fields. For larger fields, central axis dose is correctly predicted but penumbral broadening in lung is underestimated. The major source of error is the assumption that lateral electronic equilibrium is always established. A superposition algorithm has been developed for 10MV photons which calculates the dose by convolving the TERMA (Total Energy Released per unit MAss by primary photons) with a dose spread array formed using the EGS4 Monte Carlo code. TERMA and dose spread arrays are both generated using a 10 component photon energy spectrum. Dose in inhomogeneous media is calculated using dose spread arrays generated for different density media and by scaling dose spread arrays according to density variations. This method ensures that electronic disequilibrium is modelled in situations where it exists. Superposition results in a lung phantom for a 5 x 5 cm field agree with EGS4 Monte Carlo results to within 2% for p = 0.20 gcm-3 and p = 0.30 gcm-3 lung. Profiles generated by superposition for a 10 x 10 cm field at mid-lung and compared with film measurements show that penumbral broadening in low density material is also correctly predicted.

Algorithms

3-D superposition for radiotherapy treatment planning using fast Fourier transforms.

Currently used radiotherapy treatment planning algorithms based on effective path length or scatter function methods do not model electron ranging from photon interaction sites. The superposition (or convolution) technique does model this effect, which is especially important at higher (linear accelerator) energies since the electron range is significant. Another advantage of this method is that it is conceptually simple and models the physical processes directly, rather than using empirically derived methods. A major disadvantage of superposition lies in the large amount of computer time required to generate a plan, especially in three dimensions. To help solve this problem, superposition using an invariant dose spread array (kernel) can be achieved by performing a convolution in Fourier space using fast Fourier transforms (FFTs). A method for 3 dimensional calculation of dose using FFTs is presented. Dose spread arrays are calculated using the EGS Monte Carlo code, and convolved with the TERMA (total energy released per unit mass). In both cases a 10 MV nominal beam energy is modelled by a 10 component spectrum, which is compared to the result obtained using monochromatic energy only (3.0 MeV at the surface). The FFT technique is shown to be significantly faster than standard convolution for medium to large TERMA and dose spread array sizes. The method is shown to be highly accurate for small fields in homogeneous media. For larger fields the central axis depth dose is accurate but the profile shape in the penumbral region becomes slightly distorted. This is because photons incident near the beam edges are not parallel to the cartesian coordinate system used as the convolution framework. However, this effect is sufficiently small to indicate that the convolution method is suitable for use in routine treatment planning.

Fourier Analysis

Modelling polychromatic high energy photon beams by superposition.

A unified three dimensional superposition approach to dose calculations used in treatment planning of polychromatic high energy photon beams in radiotherapy is developed. The approach we have used involves computing the dose at all points in a medium by superposing the dose spread array (DSA) from the interaction of a photon at a point in the medium with an array of data representing the TERMA (photon fluence times the photon energy) at points in the beam. The polychromatic nature of the beam is accounted for by modelling the beam as having ten spectral components. A "polychromatic dose spread array" (PDSA) for an interaction from a beam with this spectrum was derived. The TERMA array is calculated from a weighted average of the TERMA arrays for the ten photon energies to give a "polychromatic TERMA array". Thus the method accounts for the effect of beam hardening of the TERMA. But it does not account for the effect of beam hardening on the PDSA since a single PDSA (usually for the spectrum at the surface of the medium) is used at all depths. However, by considering measured and calculated beam central axis data, this model is shown to be adequate for computing depth doses for beams in a homogeneous medium penetrating to extreme radiological depths. A computation time advantage is gained because only one superposition per beam is required.

Humans

Modification of spectra of pulses from ultrasonic transducers by scatters in non-attenuating and in attenuating media.

When an ultrasonic pulse is scattered off a particle, the spectrum of the scattered pulse differs from that which was transmitted. A mathematical analysis is presented to show that the center frequency of the backscattered pulse is greater than that of the transmitted pulse and that the bandwidth decreases slightly when the spectrum of the pulse is Gaussian in shape. The results of measurements designed to test the theory are presented. The magnitude of the shift in center frequency for pulses backscattered off subwavelength-diameter wires is found to be similar to that predicted by the analysis. It is shown that characteristics of the spectra of the backscattered pulses can differ from those predicted if the shape of the spectrum is not truly Gaussian (as is assumed in most published analyses, including that introduced here). In medical ultrasonic imaging, the pulses are modified by scattering and absorption. The analysis is extended to account for the effects of both interactions. This allows the bandwidth and center frequency of pulses backscattered from tissues and received by medical ultrasonic scanners to be predicted.

Scattering, Radiation

Superposition on a multicomputer system.

Superposition (convolution using a noninvariant kernel) has been shown to be a highly promising technique for use in calculating dose distributions in radiotherapy treatment planning. However, one major difficulty that currently prevents use in routine planning is the computational effort required to perform the calculation in three dimensions. To help solve this problem the superposition technique has been implemented on a parallel processor multicomputer in order to examine the performance characteristics of such a system. Up to eight elements have been connected in a pipeline (linear array), and tree networks of three and seven processors have also been constructed (using INMOS T800 transputers). The significant results obtained with these networks are: (1) Both topologies provide near-linear speedup with increasing processor number (8 processors provide 7.81 times the computing power of a single processor when using an optimal communication packet size); (2) increasing communication packet size from 1 voxel to an optimum of approximately 40 voxels significantly reduces communication overhead per processor. Overhead per processor for a 7-element linear array is 6.9% when using 1-voxel packets, but only 1.8% when using 40-voxel packets; (3) the topology of the network has some effect on communication overhead: Arranging 7 processors in a 1-2-4 binary tree reduces overhead to 80.1% of that encountered using a 7-element linear array (with packet size of 1 voxel).

Algorithms