A method for correctly setting the rf flip angle.

Currently the accepted method for setting the correct rf power levels to achieve 90 degrees and 180 degrees rf pulses for MR imaging is to peak the echo amplitude of a rf spin-echo sequence. The echo amplitude of this alpha-2 alpha pulse sequence is proportional to sin3 (alpha) and has a relatively broad maximum. Recently another method for setting the rf flip angle by maximizing the ratio of the stimulated echo to the primary echo amplitudes (in a 3 alpha sequence) demonstrated accuracy similar to that of the spin-echo method using a shorter repetition time. We present a new, more sensitive, and more accurate method for setting the correct rf power levels for 90 degrees and 180 degrees rf pulses. In this method, based upon the stimulated echo pulse sequence, we are able to accurately set the rf power to within +/- 0.1 dB by minimizing the signal amplitude of the third spin echo. This null method works for both selective and nonselective rf pulses of flip angle 90 degrees or 180 degrees, allowing the user to accurately adjust the relative amplitudes of the four rf pulse types within a single pulse sequence.

Calibration↗

Multiple short-echo (2.5-ms) quantitation of in vivo sodium T2 relaxation.

The MR behavior of the sodium-23 nucleus in vivo is a complex problem which has generated considerable interest over the last 20 years. Early studies on excised tissue samples revealed that the sodium nucleus exhibited a two-component T2 relaxation. This biexponential T2 relaxation was characterized by a short component with a T2 = 0.7-4.8 ms, and a long component with a T2 = 7.0-26.0 ms. We have developed a 3D pulse sequence capable of performing multiple Hahn echo in vivo sodium-23 imaging at echo times as short as 2.5 ms. This sequence obtains the shorter spin echo times by presaturating the spins outside of the desired imaging region, allowing the use of nonselective rf pulses. Using this sequence we have been able to quantify the long and short T2 components of normal brain tissue, vitreous humor of the eye, and a rabbit VX-2 carcinoma. We found that gray matter and white matter of normal brain have a monoexponential T2 relaxation with T2 = 17.6 +/- 2.4 ms. The vitreous humor T2 relaxation is also monoexponential with T2 = 56.8 +/- 2.1 ms. However, we find that some of the rabbit VX2 carcinomas exhibit a biexponential T2 decay with a short component of 3.3 +/- 4.6 ms and a long component of 22.0 +/- 9.0 ms.

Absorption↗

Projection flow imaging by bolus tracking using stimulated echoes.

Previous investigators have employed the concept of bolus tracking using either spin echoes or gradient echoes. In this paper we introduce two methods of bolus tracking using planar- and volume-selective stimulated echoes. The planar method employs a selective 90 degrees rf pulse which tags all spins in a particular plane. At a time tau 1 later, a nonselective 90 degrees rf pulse is employed, followed after a time tau 2, by another nonselective rf pulse. Only spins which experience all three rf pulses form a stimulated echo at time tau 1 after the third rf pulse. A balanced pair of flow-compensated dephasing (crusher) gradients further ensures that the stimulated echo is due only to the effect of all three rf pulses while minimizing flow dephasing. The first part of this gradient pair is applied after the initial rf pulse in the first tau 1 period to dephase the tagged spins. The second part of this gradient pair is applied after the third rf pulse to rephase the spins. Since the plane of the excited slice is orthogonal to the readout direction, flowing spins are imaged in an angiographic manner as they move away from the excited slice. A modification to this basic sequence excites only a small volume. In this manner, the suppression of stationary spins is effected by volume-selective excitation. In both the planar- and the volume-selective techniques, the excited spins undergo T1 and T2 relaxation during the tau 1 period but only T1 relaxation in the tau 2 period. In blood, where T1 is much greater than T2, keeping tau 1 as short as possible minimizes signal loss due to T2 dephasing. These methods demonstrate increased sensitivity compared to similar bolus tracking methods using either spin echoes or gradient echoes.

Blood Flow Velocity↗

Clinical and experimental sodium magnetic resonance imaging.

In conclusion, sodium MR imaging has potential for providing physiologic information relevant to cell mitosis, cell energy state, rCBV, and seizures. Considerable technical and experimental development is necessary, however, before sodium MRI becomes a routine examination in the clinical setting.

Brain Chemistry↗

Experimental and human brain neoplasms: detection with in vivo sodium MR imaging.

Elevations of intracellular sodium concentration have been observed in rapidly proliferating cells and malignant neoplasms. Sodium magnetic resonance (MR) imaging (with repetition times of 133 msec and echo times of 13, 26, 39, and 42 msec) was performed in ten patients and three dogs with central nervous system neoplasms. In all instances the neoplasms were associated with an increased sodium signal compared with that of normal brain. Unfortunately, the available echo times did not enable discrimination of intracellular sodium from extracellular sodium, which was present in high concentrations in adjacent vasogenic edema fluid. Further study is necessary to establish the utility of sodium MR imaging for the investigation of malignant neoplasms.

Animals↗

Magnetic resonance imaging of gadolinium-labeled monoclonal antibody polymers directed at human T lymphocytes implanted in canine brain.

Two different murine monoclonal anti-human T cell antibodies, that were coupled to gadolinium (Gd), bind specifically to human T lymphocyte cells implanted in canine brain. This binding was at a concentration of Gd sufficient to detect the implanted cells and to distinguish them from the surrounding brain tissue with magnetic resonance imaging (MRI) at a field strength of 1.5 Tesla. These Gd-labeled immunoglobulin preparations did not bind bovine T cells at a concentration sufficient to be detected on MRI. A protein solution containing the immunoglobulins (100 micrograms), gelatin (2 mg), and bovine serum albumin (2.5 mg) was reacted with the dianhydride of diethylenetriaminepentaacetic acid (DTPA); the DTPA serves as a metal chelator and as a protein crosslinking agent. The DTPA-protein complex was reacted with Gd chloride. There were approximately 10 DTPA residues per protein molecule in the modified protein mixture. Isolated human or bovine monocytes (approximately 12 million cells) were implanted in the brains of anesthetized dogs in a volume of 40 microliters. The blood-brain barrier was then disrupted by the intra-arterial injection of hyperosmotic mannitol, and the Gd-labeled antibodies were injected through a catheter placed at the branch of the internal and external carotid arteries. The brains were imaged 48 to 72 hours later. The MRI scans revealed a markedly decreased T1 relaxation time with a high signal intensity (TE = 25 msec, TR = 200 msec) related to the human T cell implants. There was no evidence of decreased T1 at the site of the bovine T cells. Neither control murine gamma globulin coupled to Gd-DTPA nor anti-human T cell antibodies uncoupled to Gd modified the MRI contrast of the human T cells in the brain.

Animals↗

Clinical and experimental vasogenic edema: in vivo sodium MR imaging. Work in progress.

To investigate the sodium magnetic resonance (MR) imaging characteristics of acute vasogenic edema, an experimental canine model was developed. Vasogenic edema was produced in the hemisphere of the dogs by the intraarterial infusion of hypertonic mannitol (25%). This solution opens the blood-brain barrier, allowing the influx of water, electrolytes, and proteins into the brain. The main advantage of this model over the established "cold injury" model is the lack of associated brain necrosis. Two patients with chronic vasogenic edema secondary to well-circumscribed meningiomas also underwent MR imaging. The sodium signal was markedly elevated in both clinical and experimental studies of vasogenic edema fluid compared with signal in healthy brain tissue. Extracellular sodium associated with vasogenic edema displayed MR imaging characteristics similar to that of sodium in serum. There was a trend toward a shortened T2 in edema fluid secondary to the presence of serum macromolecules.

Animals↗

Methodology of in vivo human sodium MR imaging at 1.5 T.

The methodology of sodium-23 (Na-23) imaging is reported in relationship to the physiological factors that determine the chemical environment of the Na-23 nucleus. Contrast resolution is given as a function of imaging time and spatial resolution. Data showing the optimal relaxation time for sodium imaging are given, and the linear quantitative relationship between sodium concentration and voxel intensity for our imaging system is confirmed. The major problem facing in vivo sodium imaging is the ability to differentiate intracellular sodium from extracellular sodium. The sodium in blood serum (extracellular) and packed red blood cells (intracellular) both exhibit biexponential T2 decay. These results indicate that T2 measurements alone will be insufficient for discriminating extracellular from intracellular sodium. Instead, other methods based on the underlying physiological properties of in vivo sodium imaging, such as the diffusion coefficient, will be necessary to truly separate extracellular from intracellular sodium.

Brain Neoplasms↗

Contrast manipulation in NMR imaging.

The past few years have shown rapid growth of NMR imaging in both image quality and diagnostic usefulness. It has become apparent, as the images have been published, that both inter- and intra-group imaging of the same underlying pathology produces images which can have vastly differing appearance. This effect is mainly due to imaging techniques which use different pulse sequence types and timings thus varying the relative contribution of the protpn density, T1, and T2 properties of the tissues. In this paper we investigate the contrast manipulation effects and methods for SNR optimization for the saturation recovery, inversion recovery, spin echo, and inversion recovery spin echo pulse sequences when applied to three clinically relevant imaging tasks.

Cerebral Infarction↗

Left ventricular volume: physical basis for attenuation corrections in radionuclide determinations.

Absolute left ventricular volume has been calculated from gated blood pool studies by estimating an attenuation correction for left ventricular counts. We studied the physical basis of these corrections by evaluating x-ray photon attenuation from CT scans of the thorax (10 second scans, no gating). CT numbers were converted to linear attenuation coefficients (LACs) at 140 keV, and LACs from the center of the left ventricle or esophagus to the chest wall (40 degrees left anterior oblique position) were determined in 12 patients of various body habitus. The mean LACs were virtually identical (0.13 cm-1 +/- 0.02 cm-1 SD), but were less than the LAC of water (0.15 cm-1). However, the esophagus was 66% further from the chest wall than the center of the left ventricle. These results suggest that conventional methods overestimate attenuation and show that LAC variability between individuals can be large. Better methods of attenuation correction may improve count-based estimates of left ventricular volume.

Adult↗

Electrical conductivity in lipid bilayer membranes induced by pentachlorophenol.

Electrical conductivity induced in thin lipid bilayer membranes by pentachlorophenol has been studied. The membranes were formed from phosphatidyl choline, phosphatidyl ethanolamine, or phosphatidyl glycerol and various amounts of cholesterol. The position and the magnitude of the maximum of the conductivity vs. pH curve depend on the type of lipids and cholesterol content. At low pentachlorophenol concentrations and low pH the concentration dependence of conductivity is quadratic and becomes linear at higher pH. Above 10(-5) M of pentachlorophenol the concentration dependence of the membrane conductivity tends to saturate. Presence of pentachlorophenol enhances membrane transport of nonactin-K+ complex. Increase of cholesterol content increases pentachlorophenol induced conductivity in all membranes and shifts the conductivity toward lower pH. For phosphatidyl choline the largest rate of change of membrane conductivity with cholesterol occurs at 1:1 phospholipid to cholesterol molar ratio. Pentachlorophenol is found to be a class II uncoupler and the experimental results are consistent with the hypothesis that the membrane permeable species are dimers formed by combination of neutral and dissociated pentachlorophenol molecules. Several schemes of membrane conduction, including dimer formation in the aqueous phase as well as at the membrane-water interface have been considered. Arguments are given in favor of the formation of dimers within the membrane surface.

Electric Conductivity↗

Correlation of cocarcinogenic activity among n-alkanes with their physical effects on phospholipid micelles.

N-alkanes from C12 to C28 were tested for their cocarcinogenic or promoting activities to evaluate a correlation of their biologic activity with their effects on transport properties of phospholipid micelles. On this basis, we had predicted that the C18 and C20 homologues would be more active than the better known dodecane. The C12, C16, C18, and C20 n-alkanes, at various dilutions from 6 to 40% by volume in decahydronaphthalene (Decalin), were tested for their relative activity in a cocarcinogenic relationship to benzo[a]pyrene. At a 20% alkane concentration level, the solutions containing octadecane and eicosane induced tumors most rapidly. A 40% dodecane concentration was required to produce this level of cocarcinogenic activity. The activity of octadecane paralleled its physical effects on transport kinetics closely in the 6-40% (by volume) concentration. The C18, C20, and C28 n-alkanes and the C30 olefin squalene at dilutions from 10 to 40% in Decalin (by volume) were tested for their relative promoting activity after a single application of 7,12-dimethylbenz[a]anthracene in benzene. At comparable mole fractions in Decalin, the three n-alkanes had essentially the same promoting activity; squalene, at 20%, showed only borderline activity. Thus the high biologic activity of the C18, C20, and C28 n-alkanes correlated well with their physical effects on the structure of phospholipid micelles (chain-chain interactions of the alkanes with the acyl chains of the lipid). This correlation was interpreted as a strong indication that the liquid crystalline region of the phospholipid assembly (adjacent to the aqueous interface) in the membranes of latent (initiated) cancer cells was the site of action of hydrocarbon cocarcinogens. Application of a modified physical model to pristane, a branched-chain C19 alkane from coal and Colorado shale, indicated higher cocarcinogenic activity than that of n-C18H38. Applied to purified samples of docosane and tetracosane, activity comparable to that of octadecane was indicated.

9,10-Dimethyl-1,2-benzanthracene↗

Hybrid DANTE and phase-contrast imaging technique for measurement of three-dimensional myocardial wall motion.

Characterization of myocardial stress and strain is necessary for a complete understanding of myocardial function. The precise quantification of regional myocardial strain is complicated by its time-varying pattern and regional variation resulting from the anisotropy of the myocardium and by complex torsional and shortening motions of the heart during the cardiac cycle. The authors have developed a technique for point-specific tracking of myocardial motion along all three axes in a constant selected section of myocardium by combining prospective section selection with in-plane DANTE (delays alternating with nutations for tailored excitation) tissue tagging and phase-contrast detection of motion perpendicular to the image plane. With this technique, it is possible to determine point-specific myocardial strain values in vivo.

Animals↗

Regional T2 and sodium concentration estimates in the normal human brain by sodium-23 MR imaging at 1.5 T.

We have analyzed multiple spin echo Na magnetic resonance (MR) images of the normal human brain in four volunteer subjects. Utilizing the much slower T2 decay of the CSF, we obtained images that separate cortex from the surrounding CSF and measured regional T2 of cortex, white matter, CSF, vitreous humor, and superior sagittal sinus. Assuming a sodium concentration of 145 mM in the vitreous humor, we normalized the extrapolated equilibrium magnetization (M0) for each region to the M0 of the vitreous humor to estimate regional sodium concentration. We found that regional T2 measurements more consistently distinguish the high signal regions of cortex, CSF, and blood than do our regional sodium estimates, whereas regional sodium estimates adequately distinguish white matter from cortex. The T2 values of white matter and cortex, on the other hand, are nearly identical. Our work addresses the problems encountered in establishing norms for clinical application of Na MR and represents a step toward establishing those norms.

Adult↗

Pulse sequence generated oblique magnetic resonance imaging: applications to cardiac imaging.

A pulse sequence procedure for producing oblique magnetic resonance images is described. Using this procedure we present a new, accurate method to obtain true short-axis views and true long-axis views (both parallel and perpendicular to the septal plane) of the heart. The method is accurate regardless of the orientation of patient's heart. The method does not require the patient to be rotated, nor otherwise moved, and does not require any additional hardware. The method is experimentally verified with both human and phantom studies. The phantom study indicates accuracy of approximately 1 degree with a commercial scanner that reports angular measurements to a precision of 1 degree. Application of the short-axis views to measurement of left ventricular volume, and possible advantages of Gauss-Legendre integration for this measurement are discussed. Finally, multiphase oblique cardiac images are presented.

Biophysical Phenomena↗

Evaluation of a prototype dual-energy computed tomographic apparatus. II. Determination of vertebral bone mineral content.

A prototype dual-energy computed tomographic (CT) scanner (Siemens Somatom DR3) with rapid kVp switching and prereconstruction processing has been used to measure vertebral bone mineral density. With this approach misregistration and beam hardening inaccuracies can be reduced considerably. Basis material images of aluminum- and Lucite-equivalent density enable measurements of bone mineral density that are nearly independent of the amount of marrow fat. To simulate variable marrow fat, alcohol-water mixtures were used as media in calibration standards. A section of dried trabecular bone was also scanned immersed in varying alcohol-water mixtures. In both simulations it was shown that the dual-energy measurement is nearly independent of marrow composition whereas the single-energy measurement would be strongly influenced by marrow fat. Dual-energy CT was compared to dual-photon absorptiometry (153Gd) for the measurement of bone mineral mass of ten excised human vertebrae. There was a high degree of correlation between the two measurements (r = 0.97). Dual-energy and single-energy CT measurements on 17 patients with suspected metabolic bone disease strongly support the conclusion that the influence of fat can lead to significant errors in single-energy determinations of the mineral density of trabecular bone.

Bone Marrow↗

Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies.

We report the evaluation of a prototype dual-energy implementation using rapid kVp switching on a clinical computed tomographic scanner. The method employs prereconstruction basis material decomposition of the dual-energy projection data. Each dual-energy scan can be processed into conventional single-kVp images, basis material density images, and monoenergetic images. Phantom studies were carried out to qualitatively and quantitatively evaluate and validate the approach.

Biometry↗