Shock occurrence in patients with an implantable cardioverter-defibrillator without spontaneous shocks before first generator replacement for battery depletion.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to W Grimm.
Explore the source record for details and available documents.
Local electrograms from 47 consecutive patients who underwent successful radiofrequency catheter ablation of 49 accessory atrioventricular (AV) connections were analyzed. One hundred twenty-two local electrograms were recorded at 27 successful and 95 unsuccessful sites immediately before radiofrequency catheter ablation of 27 manifest accessory AV connections during preexcited sinus rhythm or atrial pacing. Continuous electric activity was found in 96% of successful sites versus 71% of unsuccessful sites (p < 0.01). Possible accessory pathway (AP) potentials were present only in 15% of successful and 2% of unsuccessful sites, respectively (p < 0.05). All measured time intervals were significantly shorter for successful sites as compared to unsuccessful sites of ablation of manifest accessory AV connections. Unipolar electrograms from the tip of the ablation catheter of each successful and unsuccessful ablation site were available for the last 16 patients with manifest accessory AV connections. A PQS pattern of the unipolar electrogram was associated with a higher success rate, whereas a PrS pattern never resulted in successful ablation of an accessory AV connection. Multivariate logistic regression analysis of the local electrogram characteristics of rapidly conducting, concealed accessory AV connections revealed the interval between the onset of the local ventricular and atrial electrogram (VoAo interval) as the only independent variable associated with successful sites for radiofrequency catheter ablation. The only study patient with a slowly conducting, concealed accessory AV connection underwent successful ablation with the first lesion of radiofrequency energy at the site with the shortest VoAo interval. We conclude that (1) the shortest local AV intervals and local ventricular electrograms preceding the earliest onset of the delta wave in any surface lead are predictive of successful ablation of manifest accessory AV connections; (2) the shortest local VA intervals during orthodromic AV reentry tachycardia or right ventricular pacing are predictive of successful ablation of concealed accessory AV connections; and (3) unipolar recordings from the tip of the ablation catheter should be recorded routinely during mapping of manifest accessory AV connections to identify appropriate target sites for radiofrequency energy applications.
The legibility of three selected sets of optotypes: (1) letters; (2) Snellen E; and (3) KOLT test have been compared to the Landolt ring in a study based on the German Standard DIN 58220, Part 2 and the International Standard ISO 8597. The letters were printed in the standard typeface used on German street signs (sans serif Linear-Antiqua, Typeface B). The main results are: 1. A set of letters can be selected in such a way that the differences in legibility displayed between different letters in the set are smaller than the ISO/DIN allowance of 0.05 logarithmic units of the visual angle, although the letters are not constructed according to the traditional 5 by 5 or 5 by 4 construction principles. 2. The eight letters C, D, E, K, N, P, U, Z are proposed for standardized visual acuity tests because of their almost equal legibility. 3. The height of the typeface used for this selected set of letters should be 5% less than the diameter of the Landolt ring in order to achieve the same legibility as the latter. 4. Both shape optotypes (Snellen E and KOLT test) must be approximately 15% smaller than the diameter of the Landolt ring in order to obtain comparable visual acuity scores.
INTRODUCTION: Although intravenously administered procainamide has been used extensively during electropharmacologic testing for more than 10 years, there is little information available on the effects of incremental dosing of procainamide in patients with inducible, monomorphic ventricular tachycardia (VT). METHODS AND RESULTS: Twenty-nine patients with coronary artery disease had sustained monomorphic VT reproducibly induced in the baseline, drug-free state. Programmed stimulation was repeated 5 minutes after loading infusion (50 mg/min) of 7.5 and 15 mg/kg (all patients) and 22.5 mg/kg of procainamide (15 patients), while maintaining continuous infusion of 0.055, 0.11, and 0.165 mg/kg per minute after each increment in dose, respectively. Corresponding procainamide plasma concentrations were 5.6 +/- 2, 10.5 +/- 3, and 14.5 +/- 3 mg/L before, and 4.7 +/- 2, 9.6 +/- 3, and 14.6 +/- 4 mg/L after electrophysiologic study at each increment in dose of procainamide, respectively. Each incremental dose of procainamide resulted in significant prolongation of tachycardia cycle length and QRS duration during sinus rhythm and right ventricular pacing. Five (17%), 7 (24%), and 1 (7%) patients, respectively, had no inducible sustained VT following the incremental dosing of procainamide. Three of five patients who had no inducible VT at 7.5 mg/kg had VT induced again at a higher dose of procainamide. Four of 24 patients whose VT remained inducible at 7.5 mg/kg of procainamide had no VT induced at 15 mg/kg of procainamide. Twelve (41%), 15 (52%), and 6 (40%) patients, respectively, no longer had VT with baseline morphology induced following the incremental dosing of procainamide. VT with new morphology compared to baseline was induced in more than 40% of patients at one or more of the three different procainamide dosing regimens. The mean cycle length of VTs with new morphology was significantly shorter than the cycle length of tachycardias with baseline morphology at each particular dose of procainamide. CONCLUSION: Similar serum procainamide concentrations before and after programmed stimulation can be achieved at the described dosing regimen. Although 7.5 and 15 mg/kg of procainamide are both effective in suppressing induction of all VT in 20% to 25% of patients, non-inducibility at a particular dose of procainamide does not predict noninducibility at a respectively higher or lower dose. New morphologies of VT that are frequently faster than VTs with baseline morphology at a particular dose of procainamide can be induced in approximately half of the patients, and the clinical significance of these arrhythmias remains to be determined.
A 71-year-old group A, DC female, with anti-K4(-Kpb), -E, and -S was admitted for her second coronary artery surgery. Four units of autologous red blood cells (1BCs) were transfused perioperatively, and four units of homologous K:-4, E-, S- RBCs were transfused over the next 24 hours. Ten units of fresh frozen plasma and 28 units of platelets were also transfused. Continued bleeding necessitated calling donors from other states in AUStralia and from the International Panel of Donors of Rare Type, Bristol, UK, maintained by the World Health Organization. Four units of group 0, K:4, E-, S- KHCs were transfused in the next 24 hours while the K:-4 blood was in transit. No immediate signs of a transfusion reaction were noted. Blood pressure, temperature, bilirubin, and urinary output were normal, and an increase in hemoglobin was observed. A positive direct antiglobulin test was evident 3 days posttransfusion of the incompatible units and was still present 8 days later. Anti-A and anti-K4 were eluted from the patient's RBCs. The titer of anti-K4 increased from 8 preoperatively to 2,048 19 days posttransfusion of K:4 RBCs. Subsequent transfusions were not required, and the patient was discharged 3 weeks after the operation without further incident.
The term accelerated idioventricular rhythm describes an ectopic ventricular rhythm with 3 or more consecutive ventricular premature beats with a rate faster than the normal ventricular intrinsic escape rate of 30 to 40 beats per minute, but slower than ventricular tachycardia. Accelerated idioventricular rhythm differs from ventricular tachycardia by additional features such as the onset with a long coupling interval, the end by a gradual decrease of the ventricular rate or increase of the sinus rate and, last but not least, by a good prognosis. Clinically, accelerated idioventricular rhythm can occur in any form of structural heart disease and occasionally in adults or children without structural heart disease. Accelerated idioventricular rhythm most often can be seen in patients with coronary artery disease. Its occurrence after thrombolysis during acute myocardial infarction is a marker of successful reperfusion. Since accelerated idioventricular rhythm is usually hemodynamically well tolerated and not associated with malignant ventricular tachycardias; as a rule, no specific treatment other than care of the underlying heart disease is necessary. The present overview discusses electrocardiographic criteria, possible mechanisms, and the clinical significance of accelerated idioventricular rhythms.
Explore the source record for details and available documents.
During a follow-up of 24 +/- 20 months after treatment with an implantable cardioverter-defibrillator (ICD), 101 of 241 patients (42%) received > or = 1 spontaneous ICD shocks with documentation of the rhythm leading to shock by Holter or telemetry monitoring or stored electrograms by the device. Sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) was documented in 67 of the 101 patients (66%) with electrocardiographically documented shocks, nonsustained VT in 4 patients (4%), supraventricular tachyarrhythmias in 41 patients (41%), and normal sinus or pacemaker rhythm in 10 patients (10%). No, mild (palpitations and/or mild dizziness) and severe symptoms (presyncope/syncope) preceded spontaneous ICD shocks in 20 (30%), 33 (49%) and 27 (42%) of the 67 patients, respectively, with electrocardiographically documented VT or VF, and in 23 (56%), 16 (39%) and 1 (2%) of the 41 patients, respectively, with electrocardiographically documented supraventricular tachyarrhythmias. Three of the 4 patients with nonsustained VT had mild symptoms, and 1 patient with nonsustained VT had presyncope. None of the 10 patients with spurious discharges during normal sinus or pacemaker rhythm had symptoms preceding the ICD shocks. It is concluded that (1) most patients with either electrocardiographically documented VT/VF or a non-VT/VF rhythm preceding spontaneous ICD shocks have no or mild symptoms preceding the shock, and (2) severe symptoms preceding ICD shocks suggest sustained VT or VF as the underlying rhythm, although severe symptoms rarely occur in patients with supraventricular tachyarrhythmias or nonsustained VT.
In order to determine the incidence of complications of implantable cardioverter defibrillator (ICD) therapy, 241 patients with a total of 353 ICD implantations were followed for 24 +/- 20 months. Complications were defined as any untoward effects experienced by the patient related to the ICD implantation and function or death within 4 weeks of implant or before hospital discharge. During follow-up, 129 of 241 patients (53%) had a total of 166 complications. An operative procedure was required to correct the complication in 50 of the 241 patients (21%). No patient died intraoperatively, but eight patients died within 4 weeks postoperatively or before hospital discharge. ICD infection required removal of the device in 13 patients (5%). Twenty-six patients (11%) had postoperative respiratory complications. Postoperative bleeding and/or thrombosis occurred in 11 patients (4%). Endocardial lead migration was observed in nine patients (4%) and lead adapter or insulation break occurred in nine patients (4%). Fifty-four patients (22%) experienced ECG-documented discharges for non-VT rhythm. In conclusion, although perioperative mortality in ICD patients is low, the majority of patients have complications during follow-up. Recognition of these complications may allow for advances in ICD technology and management strategies to avoid their occurrence.
BACKGROUND: The purpose of this study was to determine the influence of clinical characteristics on shock occurrence and survival in 241 patients with implantable cardioverter-defibrillator (ICD) therapy. METHODS AND RESULTS: Two hundred forty-one consecutive patients underwent ICD implantation between November 1982 and November 1991 and were subsequently followed for 26 +/- 22 months (intention-to-treat analysis). Actuarial incidence of "appropriate" shocks was 13%, 42%, and 63%, and the incidence of any spontaneous shocks was 15%, 51%, and 76% at 1, 3, and 5 years of follow-up, respectively. Poor left ventricular function (ejection fraction < or = 30%) was associated with an earlier occurrence of both appropriate and any spontaneous ICD shocks (p = 0.001). Appropriate and any spontaneous shocks occurred significantly later in patients who presented with cardiac arrest and in patients in whom only ventricular fibrillation but no uniform ventricular tachycardia was induced during preoperative programmed stimulation. In addition, amiodarone treatment at implant was associated with later occurrence of any spontaneous shocks. Cumulative survival from all-cause mortality including perioperative mortality was 84%, 62%, and 57%, and survival from arrhythmic death was 97%, 89%, and 83% at 1, 3, and 5 years, respectively. Ejection fraction < or = 30% was the best predictor of both total arrhythmic death (p = 0.019) and total mortality (p = 0.003). Antiarrhythmic therapy with class 1 agents at implant was also associated with a higher total mortality during follow-up (p = 0.023) but not with total arrhythmic death. Age, sex, underlying heart disease, clinical presentation, and preoperative response to programmed stimulation did not predict long-term survival. In addition, survival curves were similar for patients with and without spontaneous shocks. CONCLUSIONS: The majority of patients receive shocks during long-term follow-up. The occurrence of appropriate or any spontaneous shocks during follow-up is not associated with increased arrhythmic or total mortality consistent with effective prevention of sudden cardiac death with ICD therapy in this high-risk patient population. Although low ejection fraction is the strongest predictor of both shock occurrence and mortality during follow-up, no easy algorithm can be derived from the analyzed clinical characteristics to predict which patients will benefit most from ICD implantation.
The incidence and cause of electrocardiographically documented spontaneous implantable cardioverter defibrillator (ICD) discharges for a rhythm other than ventricular tachycardia (VT) or fibrillation (VF) (unnecessary shocks) were determined in 241 patients who underwent ICD implantation between March 1983 and November 1991. During follow-up of 24 +/- 20 months, 54 of 241 patients (22%) received a total of 132 unnecessary ICD shocks confirmed by Holter or telemetry monitoring or stored electrograms (Egs) from the ICD. The rhythm preceding these unnecessary ICD shocks was atrial fibrillation in 30 patients, sinus or supraventricular tachycardia (SVT) in 11 patients, antitachycardia pacing triggered by atrial fibrillation or SVT resulting in VT in 5 patients, nonsustained VT in 3 patients, and normal sinus or pacemaker rhythm in 10 patients. Unnecessary ICD discharges occurred most frequently during the first week after implantation or generator replacement (18 of 54 patients [33%]). Unnecessary ICD discharges could be documented more often by stored Egs in patients with devices with Eg storage capability (Ventritex Cadence, 19 of 54 patients [35%]) than by Holter or telemetry monitoring in patients with devices without Egs storage capabilities (34 of 193 patients [18%], P < 0.01), despite a shorter mean follow-up duration of 14 +/- 9 months versus 26 +/- 21 months, respectively. Only six of 54 patients (11%) in whom unnecessary ICD discharges occurred had recurrent unnecessary shocks during 22 +/- 20 months of follow-up after treatment directed at the cause of the first episode or device reprogramming to preclude non-VT rhythm detection.(ABSTRACT TRUNCATED AT 250 WORDS)
Carrier-free 87Y is produced by cyclotron irradiation of Rb. It decays with a half-life of 80.3 h, transforming via 87mSr to stable 87Sr with the emission of gamma lines of 0.48 and 0.39 MeV. Experience in 6 patients shows good scan quality and correspondence between 99mTc-DPD and 87Y images useful in 90Y-citrate therapy for bone metastases. 87Y offers new possibilities of studying biological kinetics in 90Y therapy. To avoid contamination this should only be used in departments with possibilities of radioactive waste storage and controlled disposal.
A 19-year-old girl had for four weeks the clinical signs of recurrent pulmonary emboli and deep-vein thrombosis (tachycardia, dyspnoea, right inguinal pain), which had been misdiagnosed. The correct diagnosis was made only after drastic deterioration in her condition following appendicectomy for falsely diagnosed appendicitis. Urokinase infusion (80,000-160,000 IU/h for 11 days) having failed to bring about improvement, much greater than ultra-high much less than thrombolysis with streptokinase was begun (250,000 IU streptokinase over 30 min, followed by 9 million IU over 6 hours). Fatal pulmonary embolism occurred seven hours after the end of the infusion. Autopsy revealed extensive separation of thrombotic material in the pelvic veins. This observation and other reports should serve as a warning against using streptokinase in ultra-high doses if large veins, as those in the pelvis, are involved.
A novel plasmid of about 7.8 megadaltons (MDal) could be detected in a non-penicillinase-producing Neisseria gonorrhoeae strain isolated in Munich in 1987. As the strain showed no resistance against commonly used chemotherapeutic agents, at present the plasmid must be described as phenotypically "cryptic".
In many pacemaker patients bicycle and treadmill ergometry are not practicable. As an alternative, we performed a 6-minute walk on a 20-m corridor in 97 pacemaker patients, who were asked to walk as far as possible determining their speed by themselves. Results were compared with those of bicycle ergometry in 42 of these patients and with treadmill exercise of a group of 92 other pacemaker patients. In the 6-minute walk, performance and maximal heart rate were slightly lower (49 +/- 18 W; 96 +/- 23 beats/min) than in bicycle (57 +/- 16 W; 110 +/- 26 beats/min) and treadmill ergometry (50 +/- 37 W; 102 +/- 35 beats/min). A good correlation was found between walking and bicycling (r = 0.74) and in subgroups of patients with different pacemaker indications. All patients preferred the walk to bicycle ergometry considering it to be more related to daily physical activity. In conclusion, a 6-minute walk is a simple and physiological exercise test for nearly all pacemaker patients with good correlation to other types of exercise. It seems to be preferable to other tests because of its better acceptance and practicability.
UNLABELLED: Only few data are available about the course of symptoms, cardiac diseases, and spontaneous rhythm in pacemaker patients. Therefore, we followed the course of 308 paced patients (age 72 +/- 11 years) with a mean implantation time of 63 +/- 45 months. RESULTS: The symptom triad of syncope, dizziness, and dyspnea improved remarkably in 93% of patients. Thirty-nine percent suffered from coronary heart disease. The risk factors of hypertension (47%), nicotine (37%), and diabetes mellitus (25%) were found significantly more often than in a normal population with the same age and sex profile. In VVI paced patients with sick sinus syndrome (SSS, n = 67) atrial fibrillation (AF) occurred significantly more often (42%) than in patients with AV block (n = 80, 23%, P less than 0.05). Only one out of 41 DDD paced patients showed AF at follow-up. VVI stimulation seems to favor AF due to retrograde conduction in SSS. Only 3% of patients with SSS developed second- or third-degree AV block. Therefore, atrial pacing is preferable in most patients with SSS.
Eighty-four strains of Neisseria gonorrhoeae isolated in Munich between January 1987 and June 1988 were characterized in terms of their plasmid content, protein I serovar and susceptibility or resistance to four antimicrobial agents. Eighty two percent of the strains belonged to serogroup 1B, the three most prevalent serovars being 1B-1, 1B-2 and 1B-6. Among the serogroup 1A strains, 1A-2 was the commonest serovar. Fourteen strains (16.7%) lacked the 2.6 Md cryptic plasmid, although two of these strains contained the conjugative gonococcal plasmid. Although some degree of resistance to penicillin and tetracycline was noted, all the strains were sensitive to spectinomycin and cefotiam.
The activity concentrations of 99mTc-HMPAO in brain after intravenous injection were evaluated in 25 patients using SPECT. With additional first pass studies of heart and brain with the short lived isotope 195mAu, the cardiac output and the mean cerebral transit times of the patients were measured a short time before the HMPAO injection. The time dependence of 99mTc-HMPAO activity in the brain was registered during the first 5 min after injection over both hemispheres. Using a simplified three compartment model it was possible to calculate the mean retention fraction of HMPAO in brain from the time activity curves. It could be shown that the regional cerebral blood flow in ml/min per 100 g can be calculated from the activity concentration of HMPAO in the brain, the cardiac output and the retention fraction. In 15 of the 25 cases the rCBF was measured using the planar 133Xe inhalation method as a reference. We found a significant correlation between the mean hemisphere CBF from our method and the mean hemisphere grey matter CBF from the Xenon method with a correlation coefficient of 0.73.