Complications of third-generation implantable cardioverter defibrillator therapy.

To determine the incidence of complications of third-generation implantable cardioverter defibrillator (ICD) therapy, 144 patients were prospectively studied who underwent first implant of third-generation devices (i.e., ICD systems with biphasic shocks, ECG storage capability, and nonthoracotomy lead systems). During 21 +/- 15 months of follow-up, 41 (28%) patients had one or more complications. No patient died perioperatively (30 days) and no ICD infection was observed during follow-up. Complications included bleeding or pocket hematoma (hemoglobin drop > 2 g/dL) in 5 (3%) patients, prolonged reversible ischemic neurological deficit in 1 (1%) patient, postoperative deep venous thrombosis of leg in 1 (1%) patient, pneumothorax in 2 (1%) patients, difficulty to defibrillate ventricular fibrillation intraoperatively in 2 (1%) patients, generator malfunction in 1 (1%) patient, arthritis of the shoulder in 3 (2%) patients, and allergic reaction to prophylactic antibiotics in 2 (1%) patients. A total of seven lead related complications were observed in six (4%) patients including endocardial lead migration in four (3%) patients. Twenty-three (16%) patients received inappropriate shocks for supraventricular tachyarrhythmias (n = 13), non-sustained ventricular tachycardia (VT) (n = 7), or myopotential oversensing (n = 3). We conclude that serious complications such as perioperative death or ICD infection are rare in patients with third-generation ICDs. Lead-related problems and inappropriate shocks during follow-up are the most frequent complications of third-generation ICD therapy. Recognition of these complications should promote advances in ICD technology and management strategies to avoid their recurrence.

Defibrillators, Implantable↗

Transient QT prolongation with torsades de pointes tachycardia after ablation of permanent junctional reciprocating tachycardia.

INTRODUCTION: Catheter ablation with radiofrequency energy is a curative therapy in patients with permanent junctional reciprocating tachycardia (PJRT). METHODS AND RESULTS: For the first time, we report a case of transient QT prolongation with torsades de pointes tachycardia 18 hours after successful radiofrequency energy ablation of PJRT in a 25-year-old woman with tachycardia-induced cardiomyopathy. Of note, the torsades de pointes occurred in the absence of bradycardia, electrolyte disturbances, or QT-prolonging drugs. This patient initially was thought to have a hereditary long QT syndrome that was unmasked by PJRT ablation. Therefore, the patient received an implantable defibrillator in addition to beta-blocker therapy, which was discontinued 6 months later. Surprisingly, the QT interval completely normalized within 1 week after PJRT ablation, and the patient remained free of arrhythmias during a follow-up period of 4.5 years. CONCLUSION: Patients with incessant tachyarrhythmias should undergo ECG monitoring for at least 24 hours following successful radiofrequency catheter ablation because transient QT prolongation with torsades de pointes may occur even in the absence of bradycardia, QT-prolonging drugs, or electrolyte disturbances.

Adult↗

Simplified implantation of single-lead pectoral cardioverter defibrillators using device-based testing.

Device-based testing of single-lead pectoral defibrillators (defibrillation efficacy testing without an external defibrillation system after complete implantation of the device) resulted in an adequate defibrillation threshold (< or = 20 J) in 45 of 50 study patients (90%). Mean surgical implantation time (skin to skin) was 62 +/- 29 minutes without perioperative mortality and without implantable cardioverter defibrillator infection during follow-up. Thus, device-based testing appears to be a simple and safe method to test defibrillation efficacy of single-lead pectoral defibrillators.

Adolescent↗

[Artificial bradycardias due to tape-running problems of old long-term ECG records].

Artificial bradycardias due to tape-running alterations of old long-term ECG recorders were observed with increasing frequency in the last 2 years at our hospital. To document the extent of this problem, 115 consecutive 24-hour long-term ECG recordings of 10 still used tape recorders with an age of 12 +/- 4 years were examined. Analysis of the tapes with a new analysis system revealed artificial bradycardias with rates of 10 to 40/min in 22 of 115 long-term ECG recordings (19%). These artificial bradycardias were observed in 4 out of 10 examined tape recorders (40%). Three of 4 concerned recorders were 14 years old at the time of examination, and one recorder was only 5 years old. Artificial bradycardias were caused by extensive alterations of tape-running speed in all cases. Diagnostic proof of artificial bradycardias due to tape running alterations on long-term ECG are simultaneous with prolonged RR-intervals occurring increases in all ECG times including P-width. PQ-time, QRS-width and QT-duration with otherwise unchanged ECG morphology. To avoid prolonged hospital stays or therapeutic mistakes like unnecessary pacemaker implantation, especially older long-term ECG-tape recorders should be checked regularly and, if necessary, be replaced by new devices.

Artifacts↗

Programmed ventricular stimulation for arrhythmia risk prediction in patients with idiopathic dilated cardiomyopathy and nonsustained ventricular tachycardia.

OBJECTIVES: This study investigated the role of programmed ventricular stimulation (PVS) for arrhythmia risk prediction in patients with idiopathic dilated cardiomyopathy (IDC) and spontaneous nonsustained ventricular tachycardia (VT). BACKGROUND: Nonsustained VT in patients with IDC has been associated with a high incidence of sudden cardiac death. METHODS: Over the course of 4 years, 34 patients with IDC, a left ventricular (LV) ejection fraction < or = 35%, and spontaneous nonsustained VT underwent PVS. All patients were prospectively followed for 24+/-13 months. RESULTS: Sustained ventricular arrhythmias were induced in 13 patients (38%). Sustained monomorphic VT was induced in three patients (9%), and polymorphic VT or ventricular fibrillation (VF) in another 10 patients (29%). No sustained ventricular arrhythmia could be induced in 21 study patients (62%). Prophylactic implantation of third-generation defibrillators (ICDs) with electrogram storage capability was performed in all 13 patients with inducible sustained VT or VF, and in nine of 21 patients (43%) without inducible sustained VT or VF. There were no significant differences between the additional use of amiodarone, d,I-sotalol, and beta-blocker therapy during follow-up in patients with and without inducible VT or VF. During 24+/-13 months of follow-up, arrhythmic events were observed in nine patients (26%) including sudden cardiac deaths in two patients and ICD shocks for rapid VT or VF in seven patients. Arrhythmic events during follow-up occurred in four of 13 patients with inducible ventricular arrhythmias compared with five of 21 patients without inducible ventricular arrhythmias at PVS (31% vs. 24%, p=NS). CONCLUSION: PVS does not appear to be helpful for arrhythmia risk stratification in patients with IDC, a left ventricular ejection fraction < or =35%, and spontaneous nonsustained VT. Due to the limited number of patients, however, the power of this study is too small to exclude moderately large differences in outcome between patients with IDC with and without inducible VT or VF.

Adolescent↗

Failure of third-generation implantable cardioverter defibrillators to abort shock therapy for nonsustained ventricular tachycardia due to shortcomings of the VF confirmation algorithm.

Unnecessary shocks by ICDs for rhythms other than sustained VT or VF have been described as the most frequent adverse event in ICD patients. To avoid unnecessary shocks for self-terminating arrhythmias, the third-generation Jewel PCD defibrillators 7202, 7219, and 7220 Plus use a specially designed VF confirmation algorithm after charge end. The purpose of this study was to determine the ability of this VF confirmation algorithm to recognize nonsustained VT, and to analyze the reasons for failure of the PCD device to abort shock therapy for nonsustained VT despite use of this VF confirmation algorithm. Analysis of stored electrograms of electrical events triggering high voltage capacitor charging in the programmed VF zone of the device showed 36 spontaneous episodes of nonsustained VT (227 +/- 21 beats/min) during 18 +/- 7 months follow-up in 15 patients who had a Jewel PCD implanted at our hospital. Intracardiac electrogram recordings and simultaneously retrieved marker channels demonstrated that the ICD shock was appropriately aborted according to the VF confirmation algorithm in 24 (67%) of 36 episodes of nonsustained VT. Twelve episodes (33%) of nonsustained VT, however, were followed by spontaneous ICD shock in 6 (40%) of the 15 study patients. The only reason for all 12 shocks for sustained VT was the inability of the device to recognize the absence of VT after charge end due to shortcomings of the VF confirmation algorithm: 11 of the 12 shocks for nonsustained VT were triggered by the occurrence of paced beats during the VF confirmation period and 1 shock for nonsustained VT was triggered by the occurrence of 2 premature beats after charge end. Thus, better VF confirmation algorithms need to be incorporated in future PCD devices to avoid unnecessary shocks for nonsustained VT.

Defibrillators, Implantable↗

Heart rate variability during head-up tilt testing in patients with suspected neurally mediated syncope.

The relation between heart rate variability (HRV) and outcome of head-up tilt testing (HUT) in patients with neurally mediated syncope (NMS) was studied in 30 patients with presumed NMS (33 +/- 13 years) and in 11 age-matched controls. After 15 minutes of baseline supine observation, patients were tilted to 60 degrees for 45 minutes or until syncope occurred. HRV parameters included RR intervals, standard deviation of normal-to-normal RR intervals (SDNN), and root mean square successive differences (RMSSD). HRV analysis was performed during 5-minute intervals in the supine position immediately after onset of HUT and before syncope or after 30-35 minutes of tilt in patients without syncope. Syncope occurred after a mean tilt duration of 32 minutes in 14 (47%) of 30 patients with presumed NMS, whereas all controls had an uneventful HUT. In the supine position, RR intervals and RMSSD were comparable among HUT-positive patients, HUT-negative patients, and controls (RR intervals: 799 +/- 92, 854 +/- 137, and 818 +/- 128 ms, P = NS; RMSSD: 43 +/- 40, 36 +/- 34, and 53 +/- 42 ms, P = NS). Baseline SDNN was also comparable in HUT-positive patients versus HUT-negative patients with presumed NMS (50 +/- 26 vs 52 +/- 20 ms, P = NS). Within 5 minutes preceding syncope or after 30-35 minutes of tilt, RR intervals and RMSSD were shorter in HUT-positive patients compared to HUT-negative patients, or to controls (RR intervals: 606 +/- 86 vs 710 +/- 117 and 739 +/- 123 ms, P < 0.05; RMSSD: 12 +/- 5 vs 23 +/- 19 and 40 +/- 32 ms, P < 0.05). Thus, HRV analysis in the baseline supine position was not a predictor of HUT outcome in patients with suspected NMS. Syncope during HUT seemed to be preceded by increased sympathetic activity manifested by an increase in heart rate and by a decreased parasympathetic tone manifested by a decrease in RMSSD measured for 5 minutes before the event, in comparison with HUT-negative patients and with controls.

Adult↗

Baroreflex sensitivity and heart rate variability in coronary disease compared to dilated cardiomyopathy.

This study was designed to compare baroreceptor sensitivity and heart rate variability as measures of cardiac autonomic tone in patients with coronary disease (CAD, n = 49) and idiopathic dilated cardiomyopathy (IDC, n = 130). Time domain heart rate variability, including SDNN, SDANN, and pNN50, was determined during 24-hour Holter ECG. Baroreflex sensitivity was analyzed nonivasively using the phenylephrine method. Baroreflex sensitivity and heart rate variability were comparable between patients with CAD versus IDC (baroreflex sensitivity: 6.1 +/- 3 vs 6.9 +/- 5 ms/mmHg; SDNN: 97 +/- 40 vs 114 +/- 41 ms; SDANN: 83 +/- 33 vs 99 +/- 41 ms; pNN50: 3.9 +/- 4 vs 9.6 +/- 13 ms, P = NS for all comparisons). Likewise, a subgroup analysis of patients with a left ventricular ejection fraction (LVEF) < or = 30% showed no significant difference in baroreceptor sensitivity and heart rate variability between IDC and CAD patients. Patients with CAD and an LVEF > 30% had a decreased heart rate variability but not a decreased baroreflex sensitivity compared to patients with IDC and LVEF > 30% (baroreflex sensitivity: 6.4 +/- 4 vs 8.3 +/- 6 ms/mmHg, P = NS; SDNN: 98 +/- 19 vs 128 +/- 42 ms, P < 0.05; SDANN: 86 +/- 21 vs 112 +/- 43 ms, P < 0.05; pNN50: 4.2 +/- 3 vs 12.3 +/- 8 ms, P < 0.05). Patients with a markedly depressed LVEF show comparable alterations in cardiac autonomic tone whether they have CAD or IDC. Patients with CAD and preserved LV function, however, have a decreased heart rate variability compared to patients with IDC and preserved LV function. The prognostic significance of these findings will be determined prospectively in a large patient cohort at our institution.

Baroreflex↗

Noninvasive arrhythmia risk stratification in idiopathic dilated cardiomyopathy: design and first results of the Marburg Cardiomyopathy Study.

The Marburg Cardiomyopathy Study (MACAS) is a prospective, observational study designed to determine the value of the following potential noninvasive arrhythmia risk predictors in at least 200 patients with idiopathic dilated cardiomyopathy (IDC) over a 5-year follow-up period: NYHA-class, left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter, left bundle branch block and atrial fibrillation on ECG, QT/JT dispersion on 12-lead ECG, signal-averaged ECG, ventricular arrhythmias and heart rate variability (HRV) on 24-hour Holter ECG, baroreflex sensitivity, and microvolt T wave alternans during exercise. This article describes the findings among the first 159 patients with IDCs enrolled in MACAS until May 1998 (40 women, 119 men; age: 49 +/- 12 years; LVEF: 32 +/- 10%). Twenty-nine patients (18%) had atrial fibrillation and 130 patients (82%) were in sinus rhythm. Patients with sinus rhythm were further stratified according to LVEF < 30% (n = 54) versus LVEF > or = 30% (n = 76). Compared to patients with LVEF > or = 30%, patients with LVEF < 30% more often had left bundle branch block (43% vs 25%, P < 0.05), nonsustained VT (44% vs 22%, P < 0.05), decreased HRV (SDNN: 95 +/- 39 vs 128 +/- 42 ms, P < 0.01), decreased baroreflex sensitivity (5.6 +/- 4 vs 8.3 +/- 6 ms/mmHg, P < 0.01), and T wave alternans (59% vs 37%, P < 0.05). The prognostic significance of these findings will be determined by multivariate Cox analysis at the end of a 5-year follow-up. Primary endpoints in MACAS are overall mortality and arrhythmic events (i.e., sustained VT or VF, or sudden cardiac death).

Arrhythmias, Cardiac↗

Heart block in patients with obstructive sleep apnoea: pathogenetic factors and effects of treatment.

Heart block during sleep has been described in up to 10% of patients with obstructive sleep apnoea. The aim of this study was to determine the relationship between sleep stage, oxygen desaturation and apnoea-associated bradyarrhythmias as well as the effect of nasal continuous positive airway pressure (nCPAP)/nasal bi-level positive airway pressure (nBiPAP) therapy on these arrhythmias in patients without electrophysiological abnormalities. Sixteen patients (14 males and two females, mean age 49.6+/-10.4 yrs) with sleep apnoea and nocturnal heart block underwent polysomnography after exclusion of electrophysiological abnormalities of the sinus node function and atrioventricular (AV) conduction system by invasive electrophysiological evaluation. During sleep, 651 episodes of heart block were recorded, 572 (87.9%) occurred during rapid eye movement (REM) sleep and 79 (12.1%) during nonrapid eye movement (NREM) sleep stages 1 and 2. During REM sleep, the frequency of heart block was significantly higher than during NREM sleep: 0.69+/-0.99 versus 0.02+/-0.04 episodes of heart block x min(-1) of the respective sleep stage (p<0.001). During apnoeas or hypopnoeas, 609 bradyarrhythmias (93.5%) occurred with a desaturation of at least 4%. With nCPAP/ nBiPAP therapy, apnoea/hypopnoea index (AHI) decreased from 75.5+/-39.6 x h(-1) to 3.0+/-6.6 x h(-1) (p<0.01) and the number of arrhythmias from 651 to 72 (p<0.01). We conclude that: 1) 87.9% of apnoea-associated bradyarrhythmias occur during rapid eye movement sleep; 2) the vast majority of heart block episodes occur during a desaturation of at least 4% without a previously described threshold value of 72%; and 3) nasal continuous positive airway pressure or nasal bi-level positive airway pressure is the therapy of choice in patients with apnoea-associated bradyarrhythmias.

Adult↗

Extension of the International Conference on Harmonization Tripartite Guideline for Stability Testing of New Drug Substances and Products to countries of climatic zones III and IV.

The International Conference on Harmonization (ICH) Tripartite Guideline "Stability Testing of New Drug Substances and Products" sets out the stability testing requirements for a registration application within the three areas of the European Union, Japan, and the United States. These areas are assigned to climatic zone II with the storage condition of 25 degrees C/60% RH. This paper describes the adjustments that are necessary to extend the guideline to countries of climatic zones III and IV. At first storage conditions were derived with 30 degrees C/35% RH for climatic zone III and 30 degrees C/70% RH for climatic zone IV. Both conditions contain a margin of safety compared to calculated and measured data in warehouses. Furthermore, they cover the extreme temperatures above 30 and 40 degrees C which may arise in these climatic zones. Six months at 40 degrees C/75% RH was fixed as storage condition for accelerated testing to assess organoleptic and physicochemical test criteria and to make predictions for chemical stability. The predictive factor is 3.3 for 30 degrees C (6 months at 40 degrees C corresponds to 20 months at 30 degrees C). Extreme temperatures which may arise during shipment are covered by the results of stress investigations (e.g., 3 months at 50 degrees C). The next adjustment is necessary for the selection of the packaging containers. They must reflect the requirements for solid, semisolid, and liquid dosage forms caused by the two storage conditions. In the evaluation the temperature difference of 10 degrees C (40-30 degrees C) instead of 15 degrees C has to be considered, which limits the preliminary shelf lives in critical cases to 18 months instead of 24 months. Finally, statement/labeling must reflect the storage conditions. All of the other basic principles for the drug substances and drug products, such as selection and number of batches, test criteria, test procedures, specifications, testing frequency, and storage period can be applied without any change.

Climate↗

Effect of amiodarone on QT dispersion in the 12-lead standard electrocardiogram and its significance for subsequent arrhythmic events.

BACKGROUND AND HYPOTHESIS: QT dispersion, measured as interlead variability of QT intervals in the surface electrocardiogram, has been demonstrated to provide an indirect measurement of the inhomogeneity of myocardial repolarization. The purpose of the present study was twofold: (1) to analyze the effect of amiodarone on QT dispersion measured in the 12-lead standard ECG, and (2) to examine the association between QT dispersion on amiodarone and subsequent arrhythmic events. METHODS: To determine the effect of amiodarone on QT dispersion and its clinical significance for subsequent arrhythmic events, QT dispersion was measured in the 12-lead standard electrocardiogram (ECG) in 52 patients before and after administration of empiric amiodarone for ventricular tachyarrhythmias. RESULTS: QT intervals increased from 401 +/- 44 ms before amiodarone to 442 +/- 53 ms after amiodarone therapy, and rate corrected QT intervals (QTc) increased from 452 +/- 43 ms to 477 +/- 37 ms, respectively (p < 0.01). QT dispersion, QTc dispersion, and adjusted QTc dispersion, which take account of the number of leads measured, were not significantly different before and after initiation of amiodarone therapy (58 +/- 24 ms vs. 61 +/- 26 ms, 68 +/- 29 vs. 66 +/- 26 ms, and 22 +/- 8 vs. 22 +/- 8 ms, respectively, p = NS). During 31 +/- 25 months follow-up after initiation of amiodarone therapy, arrhythmic events defined as sustained ventricular tachycardia, ventricular fibrillation, or sudden death occurred in 11 of 52 study patients (21%). QT dispersion, QTc dispersion, and adjusted QTc dispersion on amiodarone were not different between patients with and without arrhythmic events during follow-up (65 +/- 14 vs. 59 +/- 29 ms, 73 +/- 15 vs. 64 +/- 28 ms, and 25 +/- 6 vs. 21 +/- 8 ms, respectively, p = NS). CONCLUSIONS: We conclude that (1) amiodarone increases QT intervals and QTc intervals during sinus rhythm but does not significantly change measures of QT dispersion; and (2) QT dispersion measured in the 12-lead standard ECG after initiation of amiodarone therapy does not appear to be a useful marker for subsequent arrhythmic events.

Amiodarone↗

[Long-term ECG].

Explore the source record for details and available documents.

Bradycardia↗

High dose naloxone does not improve cerebral or myocardial blood flow during cardiopulmonary resuscitation in pigs.

In a prospective, randomized, placebo-controlled, double-blind trial we tested the hypothesis that naloxone given during cardiopulmonary resuscitation (CPR) enhances cerebral and myocardial blood flow. Twenty-one anesthetized, normoventilated pigs were instrumented for measurements of right atrial and aortic pressures, and regional organ blood flow (radiolabeled microspheres). After 5 min of untreated fibrillatory arrest, CPR was commenced using a pneumatic chest compressor/ventilator. With onset of CPR, an i.v. bolus of 40 micrograms/kg b.w. of epinephrine was given, followed by an infusion of 0.4 micrograms/kg per min. After 5 min of CPR, either naloxone, 10 mg/kg b.w. (group N, n = 11) or normal saline (group S, n = 10) was given i.v. Prior to, and after 1, 15, and 30 min of CPR, hemodynamic and blood flow measurements were obtained. After 30 min of CPR, mean arterial pressure was significantly higher in group N (26 +/- 5 vs. 13 +/- 3 mmHg, P < 0.05). Groups did not differ with respect to myocardial perfusion pressure or arterial blood gases at any time during the observation period. Regional brain and heart blood flows were not different between N and S at any point of measurement. We conclude that high-dose naloxone does not augment cerebral or myocardial blood flow during prolonged closed-chest CPR.

Acid-Base Equilibrium↗

Increase in DNA single-strand break rejoining by continuous exposure of human mononuclear blood cells to radioiodine ((131)I) in vitro.

Radioiodine ((131)I) induced a dose- and time-dependent increase in DNA single-strand breaks (DNA-ssb) in human (G0) mononuclear blood cells (MNC) in vitro. Incubation of MNC with 22MBq (131)I/ml at 4 degrees C caused a linear, time-dependent induction of DNA-ssb (increase in elution rate: 24.7 x 10(-3) h(-1) per 100 min incubation with (131)I). However, if MNC were incubated at 37 degrees C a decrease in the slope of the time effect curve was observed after about 300 min incubation with 22 or 30 MBq (131)I/ml. The goodness of fit of different regression models was assessed by Akaike's Information Criterion (AIC). The best fit was obtained for a non-linear model (y=a+bx+cx(0.5); AIC=53.5; where x is incubation time and y is elution rate), whereas other models including the linear regression model y=a+bx; AIC=38.6) were worse. As the total induction of DNA-ssb at 4 degrees C was constant with time, the decrease in the slope of the time effect curve (DNA-ssb versus time) at 37 degrees C can be interpreted as an increase in rejoining of DNA-ssb. Inhibition of both RNA and protein synthesis clearly increased the extent of DNA-ssb observable after incubation with (131)I. Thus, during continuous exposure of MNC to (131)I, proteins were synthesized which rejoined DNA-ssb. However, incubation of MNC with (131)I (44 MBq/ml) at 37 degrees C under conditions expected to lead to inhibition of RNA and/or protein synthesis still resulted in a decrease of the slope of the time effect curve, indicating a stimulation of DNA-ssb rejoining. Thus, we favour the hypothesis that the increase in the activity of DNA-ssb rejoining, besides de novo synthesis of repair enzymes, is also caused by a post-translational stimulation of DNA-repair enzymes and that this stimulation possibly is mediated by DNA-fragments.

DNA Repair↗

Syncope recurrence can better be predicted by history than by head-up tilt testing in untreated patients with suspected neurally mediated syncope.

BACKGROUND: Head-up tilt testing is widely used in the evaluation of patients with suspected neurally mediated syncope. Although it remains unclear which patients require medical therapy to prevent recurrent syncope, most centres initiate empiric medical therapy in all patients in whom neurally mediated syncope has been diagnosed. To determine the natural history of this condition, we followed 80 untreated patients. METHODS: All 80 study patients fulfilled the following inclusion criteria: (1) > or = 1 syncope in the upright position, (2) absence of structural heart disease, (3) unremarkable work-up for other known causes of syncope. Thirty-nine patients had a history of one episode of syncope (group A) and 41 > or = 2 episodes of syncope (group B). Head-up tilting was performed in all patients at 60 degrees for a maximum of 45 min without medical provocation ('Westminster Protocol'). RESULTS: Suspected neurally mediated syncope could be reproduced by tilt testing in four of 39 patients from group A vs 10 of 41 patients from group B (10% vs 24%, P = 0.1). Independent of the result of head-up tilt testing, all patients were prospectively followed without medical therapy. During 23 +/- 8 months follow-up, syncope recurred in four of 39 group A patients vs 22 of 41 group B patients (10% vs 54%, P < 0.05). The incidence of syncope during follow-up was not significantly different between patients with and without positive baseline tilt test (43% vs 30%, P = ns). CONCLUSIONS: (1) 90% of patients with a single episode of syncope remain free of recurrent syncope without medical therapy irrespective of the result of tilt testing. (2) About half of patients with a history of > or = 2 syncopal episodes have recurrent syncope and, thus, may be appropriate candidates for prophylactic medical therapy. (3) Although head-up tilt testing at 60 degrees for up to 45 min does not appear to be useful to predict recurrent syncope in untreated patients, it is still a useful test in its evaluation.

Adolescent↗

Magnetic resonance imaging and signal-averaged electrocardiography in patients with repetitive monomorphic ventricular tachycardia and otherwise normal electrocardiogram.

Early or localized forms of arrhythmogenic right ventricular dysplasia (ARVD) have been proposed as the arrhythmogenic substrate of repetitive monomorphic ventricular tachycardia (RMVT) originating in the right ventricular outflow tract in patients without any underlying cardiac abnormality on clinical examination and echocardiography. To further examine this hypothesis, magnetic resonance imaging (MRI) and signal-averaged electrocardiography (SAECG) were performed on 23 patients with RMVT and normal 12-lead standard ECG of conducted sinus beats. MRI was performed using ECG-gated turbo spin-echo images of the heart in order to detect signs of early or localized forms of ARVD, such as localized wall thickness reductions, signal intensity increase indicating adipose tissue infiltrates, and regional bulgings or aneurysms. MRI was normal in 22 (96%) of 23 study patients. In the remaining patient (4%), MRI demonstrated signal intensity increase in the intraventricular septum but not in the right ventricular outflow tract. Time-domain analysis of the SAECG was normal in 21 (91%) of 23 patients and revealed ventricular late potentials in 2 study patients (9%). Frequency-domain analysis of the SAECG was normal in 22 (96%) of 23 patients and revealed ventricular late potentials in one study patient (4%). We conclude that normal MRI findings of the heart and absence of ventricular late potentials in the SAECG in most patients with RMVT and otherwise normal ECG do not support the hypothesis that early or localized forms of ARVD create the arrhythmogenic substrate in the majority of these patients.

Action Potentials↗

Does the initial presentation of patients with implantable defibrillator influence the outcome?

The influence of the clinical presentation on the long-term outcome in 213 consecutive patients with ICDs, ECG storage capability, and nonthoracotomy leads, was analyzed. Sixty-six patients presented with cardiac arrest (CA), 81 patients with hemodynamically stable VT, and 66 patients with syncope (SY). Patient characteristics were: mean age CA 62, VT 61, SY 61 years; mean ejection fraction CA 31%, VT 29%, SY 30%; coronary artery disease CA 71%, VT 71%, SY 64% (all P > 0.05 Fisher's exact test); female gender CA 40%, VT 14%, SY 19% (CA vs VT and SY, P < 0.005); inducibility by programmed stimulation CA 50%, VT 84%, SY 61% (VT vs CA and SY, P < 0.001, CA vs SY, P > 0.05). During a mean follow-up of 14.5 months, 29 patients died: CA 12%, VT 14%, SY 9% (P > 0.05). Comparing Kaplan-Meier curves, no difference in the time course of overall mortality was found (log-rank P > 0.05). In the CA, VT, and SY groups, 543, 1,630, and 189 ICD therapies (including antitachycardia pacing, low energy cardioversion, and defibrillation) were observed, respectively. Actuarial analysis showed a shorter interval between implantation and first ICD therapy for VT versus CA and SY (log-rank P < 0.005). Patients presenting with VT experienced earlier and more frequent ICD therapies than patients with CA or SY independent of age, ejection fraction, and heart disease. No difference in overall mortality and time course of fatal events was observed among the three groups.

Actuarial Analysis↗