Search PubMedSearch

Biomedical subjects

W Göpel

Publications and source records attributed to W Göpel.

At least 19 recordsLinked to original sources

Bioelectronic noses: a status report. Part II.

The present state of the art to record or to mimic electronically the human senses of olfaction and taste is characterized. In this part II, strategies are outlined to utilize chemical and biological structures with their different complexities which serve as sensor elements in (bio-) electronic noses. Finally a survey is given on the computer-science aspects of odor recognition based on these elements.

Animals

Bioelectronic noses: a status report. Part I.

The present state of the art to record or mimic electronically the human senses of olfaction and taste is characterized. In this part I, an introduction to our present understanding in the development of electronic and bioelectronic noses is given. Finally the natural olfactory system is described in detail.

Brain

Biosensor development.

Current biosensor developments can be summarised by different trends. For traditional enzymatic biosensors such as glucose sensors, steady improvements of well known basic principles have been made in order to achieve better sensor stability. On the other hand, new affinity sensors such as nucleic acid sensors, transmembrane sensors, and sensors utilising whole cells or even cell networks have become of increasing interest. New ways to miniaturise biosensors and to control their interfaces down to the molecular level have been introduced (the bioelectronics approach). High-throughput screening based on various signal transduction principles has become of increasing importance.

Antigen-Antibody Reactions

Chiral discrimination of inhalation anesthetics and methyl propionates by thickness shear mode resonators: new insights into the mechanisms of enantioselectivity by cyclodextrins.

The discrimination of the enantiomers of methyl lactate, methyl 2-chloropropionate, and the inhalation anesthetics enflurane, isoflurane, and desflurane in the gas phase has been performed using thickness shear mode resonators. The selective coating was a modified perpentylated gamma-cyclodextrin derivative dissolved in a polysiloxane matrix. A new model for the sorption of the chiral compounds into the cyclodextrin cavities and into the polymer matrix was established for the purpose of characterizing the sensor responses. This characterization included the fitting of the sensor responses (preferential and nonpreferential sorption) according to the model and extracting the characteristic parameters. In particular we attempted to explain the observed variation of the chiral discrimination factor alpha with changing analyte or cyclodextrin concentrations and search for an invariable parameter, characteristic for a certain analyte-cyclodextrin combination. The process of chiral or "molecular" recognition was thoroughly investigated.

Anesthetics, Inhalation

Chiral discrimination using piezoelectric and optical gas sensors.

Odour perception in humans can sometimes discriminate different enantiomers of a chiral compound, such as limonene. Chiral discrimination represents one of the greatest challenges in attempts to devise selective and sensitive gas sensors. The importance of such discrimination for pharmacology is dear, as the physiological effect of enantiomers of drugs and other biologically active molecules may differ significantly. Here we describe two different sensor systems that are capable of recognizing different enantiomers and of qualitatively monitoring the enantiomeric composition of amino-acid derivatives and lactates in the gas phase. One sensor detects changes in mass, owing to binding of the compound being analysed (the 'analyte'), by thickness shear-mode resonance; the other detects changes in the thickness of a surface layer by reflectometric interference spectroscopys. Both devices use the two enantiomers of a chiral polymeric receptor, and offer rapid on-line detection of chiral species with high selectivity.

Alanine

Quartz crystal microbalances for quantitative biosensing and characterizing protein multilayers.

The use of quartz crystal microbalances (QCMs) for quantitative biosensing and characterization of protein multilayers is demonstrated in three case studies. Monolayers of QCM-based affinity biosensors were investigated first. Layers of a thiol-containing synthetic peptide constituting an epitope of the foot-and-mouse-disease virus were formed on gold electrodes via self-assembly. The binding of specific antibodies to epitope-modified gold electrodes was detected for different concentrations of antibody solutions. Oligolayers were studied in a second set of experiments. Dextran hydrogels were modified by thrombin inhibitors. The QCM response was used in a competitive binding assay to identify inhibitors for thrombin at different concentrations. Multilayers of proteins formed by self-assembly of a biotin-conjugate and streptavidin were investigated next. The QCM frequency response was monitored as a function of layer thickness up to 20 protein layers. A linear frequency decay was observed with increasing thickness. The decay per layer remained constant, thus indicating perfect mass coupling to the substrate. Frequency changes a factor of four higher were obtained in buffer solution as compared to measurements in dry air. This indicates a significant incorporation of water (75% weight) in the protein layers. This water behaves like a solid concerning the shear mode coupling to the substrate. The outlook discusses briefly the need for controlled molecular engineering of overlayers for subsequent QCM analysis, and the importance of an additional multiparameter analysis with other transducer principles and with additional techniques of interface analysis to characterize the mechanical coupling of overlayers as biosensor coatings. A promising trend concerns the use of QCM-arrays for screening experiments.

Biosensing Techniques

Odor, drug and toxin analysis with neuronal networks in vitro: extracellular array recording of network responses.

Neurons, by virtue of intrinsic electrophysiological mechanisms, represent transducers that report the dynamics of cell death, receptor-ligand interactions, alterations in metabolism, and generic membrane perforation processes. In cell culture, mammalian neurons form fault-tolerant, spontaneously active systems with great sensitivity to their chemical environment and generate response profiles that are often concentration- and substance-specific. Changes in action potential patterns are usually detected before morphological changes and cell damage occur, which provides sensitivity and reversibility. Such biological systems can be used to screen rapidly for novel pharmacological substances, toxic agents, and for the detection of certain odorants. Existing simple culture preparations can already be employed effectively for the detection of chemical compounds. So far, three strategies have been investigated in pilot experiments: (1) Substance-dependent major changes in spontaneous native activity patterns. All synaptically active agents (e.g. glutamate, strychnine, N-methyl D-aspartic acid) as well as metabolic poisons generate such changes. (2) Substance-dependent changes in network oscillations via disinhibition. The regularized, oscillatory activity is altered by synaptically and metabolically active substances, ion channel blockers, and toxins. (3) Detection of paroxysmal responses indicating major, pathological membrane currents in large subpopulation of cells. We have explored these three strategies via 64 channel array recordings using spontaneously active murine spinal cord cultures. The glycine receptor blocker strychnine reliably generated increased multichannel bursting at 5-20 nM and regular, coordinated bursting above 5 microM. During biculline-induced network oscillations many compounds alter oscillation frequencies or terminate activity in a substance-specific manner. Finally, the gp120 protein of the AIDS virus (at 1 microgram/ml) produces massive, unique paroxysmal discharges that may last as long as 2 min. These results indicate that cultured neuronal networks are practical systems that can be used for the detection and identification of a great variety of chemical substances. The concept of dynamic fingerprinting to identify specific compounds is discussed.

Animals

Characterization and optimization of microelectrode arrays for in vivo nerve signal recording and stimulation.

Revealing the complex signal-processing mechanisms and interconnection patterns of the nervous system has long been an intriguing puzzle. As a contribution to its understanding the optimization of the impedance behavior of implantable electrode arrays with via holes is discussed here. Peripheral axons will regenerate through these holes allowing for simultaneous nerve stimulation and signal recording. This approach is part of the ESPRIT project INTER and may eventually lead to devices driving sensory motor prosthesis with closed loop control. In the first set of experiments, micromachined platinum electrode arrays were prepared, characterized and optimized for nerve signal recording. The results of these studies are based on impedance spectroscopy and microscopic techniques. Equivalent circuits were modeled describing formally the electrical response behavior with ohmic resistances between 500 omega and 10 k omega. To attain low impedances for all electrodes on the INTER device, platinum from H2PtCl6 was electrodeposited, and sputter technology as well as electrochemical deposition from H2IrCl6 solution were used to produce thin iridium films. For the former, a lift-off process was established at one of the institutes to generate electrode structures with a line width of 5 microns. As a result in all three cases the electrodes showed almost constant impedances over the entire frequency range (10 Hz-1 kHz), which is relevant for nerve signal recording. In the second set of experiments, electrodes were optimized to allow for nerve stimulation. For this purpose, the charge delivery capacity (CDC) had to be increased and the impedance had to be decreased. Iridium oxide is the material of choice, because its CDC is much higher than the CDC of platinum at 75 microC/cm2 (Ziaie et al., 1991, IEEE Sensors & Actuators Transducers, 6, 124-127). A significant increase of the electrochemically active surface of the electrode structures could be observed by measuring the surface roughness. In first experiments, an activated iridium oxide film was formed with cyclic voltammetry and was evaluated using scanning force microscopy and impedance spectroscopy. The evaluation of the cyclic voltammograms showed a CDC up to 400 mC/cm2 for sputter deposited and oxidatively treated iridium films. Further investigations are directed towards increasing the stability of the iridium oxide electrodes with regard to long-term implants. Parallel experiments aim at the controlled axon adhesion without changing the impedance behavior of the described electrodes.

Electric Impedance

Strychnine analysis with neuronal networks in vitro: extracellular array recording of network responses.

Neurons, by virtue of intrinsic electrophysiological mechanisms, represent transducers that report the dynamics of cell death, receptor-ligand interactions, alterations in metabolism and generic membrane perforation processes. In cell culture, mammalian neurons form fault-tolerant, spontaneously active systems with great sensitivity to their chemical environment and generate response profiles that are often concentration- and substance-specific. Changes in action potential patterns are usually detected before morphological changes and cell damage occur. This provides sensitivity and reversibility. Such biological systems may be used to screen rapidly for novel pharmacological substances, toxic agents and certain odorants. This paper reports on substance-dependent major changes in spontaneous native activity patterns by the synaptically active (glycine receptor blocker) strychnine. Via 64-channel array recordings of spontaneously active murine spinal cord cell cultures, increased multichannel bursting at 5-20 nM strychnine and regular, coordinated bursting above 5 microM could be reliably generated. By artificial neural network analysis a quantitative correlation of network signals and strychnine concentration could be evaluated for small concentrations of strychnine. The results indicate that cultured neuronal networks already represent reliable and practical systems which can be used for the detection of chemical substances and the characterization of their biological influences.

Animals

A 'mixed' self-assembled monolayer for an impedimetric immunosensor.

A synthetic peptide with the amino acid sequence 135-154 of the capsid protein VP1 of the foot-and-mouth-disease virus was modified with omega-hydroxyundecanethiol and applied together with non-derivatised omega-hydroxyundecanethiol for consecutive adsorption onto gold electrodes according to self-assembling procedures. The binding of a specific antibody to prepared recognition layers could be monitored by measurement of impedance or capacitance. In order to avoid non-specific effects, all measurements were performed in the presence of BSA. The complex between the antigenic peptide and the antibody was split by applying 6 M urea solution. The gold electrodes were mounted into an optimised flow-through system in order to perform capacitance-time measurements. The immobilised peptide can be recognised repeatedly by specific antibodies.

Amino Acid Sequence

The gene for the thyrotropin receptor (TSHR) as a candidate gene for congenital hypothyroidism with thyroid dysgenesis.

According to the central role of the TSH receptor for thyroid function and growth the gene for the TSH receptor is a possible candidate gene for mutations which result in an impairment of thyroid growth and function (Vassart and Dumont 1992). First evidence for the role of TSH receptor defects in the pathogenesis of congenital thyroid disorders was elucidated by the presence of activating germline mutations leading to congenital hyperthyroidism (Duprez et al., 1994). After the finding of partial loss-of-function mutations leading to hyperthyrotropinemia (Sunthornthepvarakul et al., 1995) it was speculated that a more severe phenotype with hypothyroidism and hypoplasia of the gland (thyroid dysgenesis) would be the result, if complete loss-of-function mutations like the isoleucine167 to asparagine mutation would occur in a homozygote or compound heterozygote state. The screening of TSHR gene mutations by SSCP in a well defined cohort of 100 children with congenital hypothyroidism (CH), diagnosed and followed since 1978 in the Childrens Hospital of Berlin, revealed one patient with hypoplasia of the thyroid to be positive for two compound heterozygote inactivating mutations of the TSHR gene, indicating thereby that the clinical approach to define phenotypes of interest could be helpful to understand the fundamental process of thyroid development.

Animals

Earliest prevention of endemic goiter by iodine supplementation during pregnancy.

During pregnancy complex changes of maternal thyroid function occur and they are influenced by the maternal iodine supply. It has been demonstrated that with decreasing iodine supply maternal goiter and hypothyroxinemia as well as fetal and neonatal hypothyroidism become more prevalent. Therefore iodine supplementation during pregnancy is now strongly recommended also in areas of moderate iodine deficiency. To monitor the success of iodine supplementation and its theoretical risk of increasing the frequency of thyroid autoantibodies, we have investigated the thyroid volume, thyroid function, urinary iodine excretion and antibodies to thyroid peroxidase at 10-12 weeks of gestation and postpartum in 38 mothers receiving 300 micrograms potassium iodide/day and in 70 mothers without iodine supplementation. In all of their newborns thyroid volume was determined by ultrasound. The thyrotropin (TSH) levels and antibodies to thyroid peroxidase (TPO-ab) in the neonates were measured in dried blood spots on filter paper from their newborn screening. Urinary iodine excretion was increased significantly after iodine supplementation in mothers (p < 0.001) and their newborns (< 0.05). No hypo- or hyperthyroidism was observed in the mothers or newborns. Interestingly, no difference of maternal thyroid volumes was observed between the two groups after pregnancy, but the volumes of the thyroid glands in newborns of mothers who received iodine were significantly (p < 0.004) lower (0.7 +/- 0.4 ml) than in the control group (1.5 +/- 1.1 ml). There was no change in the frequency of TPO-ab in either group after pregnancy. In four mothers transplacental passage of these antibodies was documented by positive measurement in the blood sample of the newborn. This study documents that iodine supplementation during pregnancy in an area of moderate iodine deficiency results in a lower size of neonatal thyroid volume and that this supplementation was not accompanied by an increase in the frequency of TPO-ab.

Autoantibodies

Interface analysis in biosensor design.

In a survey, the analytical tools to characterise and optimise properties and stabilities of interfaces in thin film biosensors are discussed. After an introduction to microscopic and spectroscopic techniques and different transducers, case studies are presented. They concern bioaffinity sensors with particular emphasis on biomimetic recognition structures, catalytic sensors, transmembrane sensors, cell sensors, and the ambitious goal of addressing individual biomolecular function units.

Biosensing Techniques

Optimized biosensor for whole blood measurements using a new cellulose based membrane.

We used bacterial cellulose membranes as outer membranes for glucose sensors based upon amperometric detection of glucose oxidase reaction products. We found a long-term stability in 1:10 diluted blood of about 200 h. In comparison a Cuprophan membrane was stable for only 30 h under the same conditions. Comparing the two membranes in undiluted human blood, a similar trend was found in the long-term stability; Cuprophan was stable for only 3-4 h and the glucose sensor with the bacterial cellulose membrane was stable for more than 24 h. In addition, the measuring range of the glucose sensor could be extended up to 170 mM glucose by treating the bacterial cellulose membrane with a polyamide.

Ascorbic Acid