Respiration and measurement of cardiac output by thermodilution and central or peripheral dye dilution.

Cardiac output as measured by indicator dilution methods during artificial ventilation shows differences up to +/- 35%. We studied the influence of spontaneous breathing on measurement of cardiac output by thermodilution (TD) and central (CDD) and peripheral dye dilution (PDD) in seven anesthetized dogs. Injection of indicator was timed at one of five chosen moments in a respiratory cycle. The indicator for TD was also used as solvent for indocyanine green. Results were normalized by the value obtained with injection at inspiratory onset. Results of the central dilution methods showed a slight but not significant difference between values measured with injection at 25 and 75% of the respiratory cycle: 105.7 and 98.0%, respectively, (TD) and 102.3 and 97.2% (CDD). Mean cardiac output determined by TD, CDD, or PDD was not significantly different. We conclude that 1) a reasonable estimate of cardiac output may be obtained by means of a single indicator-dilution curve and 2) the choice of the dilution method may be determined by practical considerations.

Animals

Distribution of systemic blood flow in lambs with an aortopulmonary shunt during strenuous exercise.

We studied regional blood flows with radioactive-labeled microspheres in 12 7-wk-old lambs with an aortopulmonary left-to-right shunt [59 +/- 3% (SE) of left ventricular (LV) output] and in 11 control lambs, at rest and during exercise at 80% of predetermined peak O2 consumption. At rest, systemic blood flow was similar in the two groups. Blood flow to the heart and diaphragm was substantially higher in the shunt than in the control lambs. Blood flow to the other organs was not significantly different between the two groups. During exercise, systemic blood flow increased substantially but less in shunt (81%) than in control lambs (134%). Blood flow to the heart and diaphragm increased, that to the heart still being higher in shunt than in control lambs. Blood flow to the brain did not change, whereas that to the kidneys and splanchnic organs decreased to the same extent (25%) in shunt and control lambs. Intrahepatic and intrarenal blood flow redistribution in the shunt lambs persisted during exercise. In conclusion, myocardial blood flow is not increased at the expense of one particular organ, nor is it associated with an essential change in exercise-induced redistribution in shunt lambs.

Aging

Measurement of total bodywater volume with deuterated water in newborn infants.

D2O and H2(18)O are often used as tracers for the determination of total body water (TBW). For newborn infants, the commonly used noninvasive method has not been validated. In this study TBW was calculated from D2O concentrations in blood and compared with TBW calculated from D2O concentrations in urine. TBW calculated from all urine portions voided at least 6 h after D2O administration on average was 1.0% lower. TBW calculated from only three urine portions voided 6, 12, and 24 h after D2O administration was 0.6% (mean) lower compared to TBW calculated from D2O concentrations in blood. This study indicates that the noninvasive method to measure TBW can be considered a reliable method when used in newborn infants.

Body Water

Blood volume and body fluid compartments in lambs with aortopulmonary left-to-right shunts.

A left-to-right shunt is accompanied by an increased plasma and blood volume. Since this is likely realized through renin/aldosterone-mediated salt and water retention, other body fluid compartments may be changed too. Therefore, we studied blood volume and body fluid compartments by a single-injection, triple-indicator dilution technique in nine 8-wk-old lambs with an aortopulmonary left-to-right shunt (55 +/- 3% of left ventricular output; mean +/- SEM) and in 11 control lambs, 2.5 wk after surgery. Systemic blood flow was maintained at the same level as in control lambs, but the aortic pressure of the shunt lambs was lower. Blood volume in shunt lambs was larger than in control lambs (110 +/- 6 vs. 84 +/- 7 ml/kg, P < 0.001) through an increase in plasma volume, which correlated significantly with the magnitude of the left-to-right shunt (r = 0.81, P < 0.01). Red blood cell volume was equal to that of control lambs. Evidence was obtained that the increase in plasma volume was induced by a transient increase in renin (8.0 +/- 2.2 vs. 1.6 +/- 0.2 nmol.l-1.h-1; P < 0.02) and aldosterone (0.51 +/- 0.14 vs. 0.24 +/- 0.09 nmol/liter) concentrations. Interstitial water volume, however, was not significantly different from that in control lambs. The amount of intravascular protein was significantly higher than in control lambs (5.0 +/- 0.3 vs. 3.5 +/- 0.2 g/kg body mass, P < 0.001). There were no significant differences in intracellular and total body water volumes between the two groups. We conclude that the increased amount of intravascular protein confines the fluid retained by the kidneys to the vascular compartment.

Aldosterone

A fiberoptic reflection densitometer with cardiac output calculator.

A catheter-tip densitometer for indocyanine green is described consisting of a cardiac catheter containing optical fibers, an incandescent light source, a light detection unit and a processing unit. Half of the optical fibers guide the light to the blood at the tip of the catheter, the other half the back-scattered (reflected) light to the detection unit. In the detection unit the light is measured by two silicium barrier layer photocells after it has been split into two beams by a beam splitter. In the measuring channel the light passes an 800 nm filter before reaching the photocell. When fiberoptic catheters with glass fibers are employed, the other channel, used for compensation of non-specific effects such as blood flow variations, contains no filter, thus measuring light in a broad spectral band. It is shown that in this way compensation of flow effects may be about two times better than when a 920 nm filter is used. When using plastic optical fibers a 950 nm filter must be used, because above lambda = 850 nm plastic fibers transmit only a band around that wavelength (950 nm). At zero dye concentration the densitometer output or ratio of compensating and measuring photocell output R/R800 is almost insensitive to changes in haemoglobin concentration. When the blood contains dye, however, the influence of haemoglobin concentration is considerable. The densitometer output R/R800 is linearly related to dye concentration up to 50 mg . 1-1, the output R920/R800 up to 30 mg . 1(-1). The output R/R800 decreases with decreasing oxygen saturation; the slope of the calibration line, however, appears to be unaffected. The processing unit also contains an analog cardiac output calculator consisting of an integrator and a divider. Central dye dilution curves recorded from the pulmonary artery after injection of dye into the right atrium or a caval vein come down to the baseline. At this moment the reading of a digital voltmeter displaying the divider output calibrated in 1 . min-1 can be held and the reading taken.

Animals

Decomposition on freezing of reagents used in the ICSH-recommended method for the determination of total haemoglobin in blood; its nature, cause and prevention.

The decomposition on freezing of reagents used for the determination of total haemoglobin in blood was reinvestigated. When these reagents containing hexacyanoferrate(III) (ferricyanide) and cyanide are frozen and then thawed, hexacyanoferrate(III) is reduced to hexacyanoferrate(II) (ferrocyanide), cyanide being oxidized to (CN)2. At higher concentrations of the reactants than those present in the ICSH-recommended reagents, this reaction proceeds also at room temperature. During the process of freezing the reaction proceeds at low overall concentration of the reactants because the reactants become highly concentrated at the moving phase boundary. There is no evidence that the reaction that takes place on freezing can be prevented by the addition of ethanol, methanol, ethylene glycol or glycerol. Addition of these compounds does not affect the suitability of the reagent for use in haemoglobinometry.

Chromatography, Gas

Incomplete cardiac vagal blockade with atropine in the anesthetized dog.

In dogs in neurolept-anesthesia the successive administration of alpha- and beta-adrenergic blocking agents and atropine, which should cause the functional equivalent of surgical denervation of the heart, always results in a marked tachycardia. The same is observed in conscious dogs, but not during methoxyflurane anesthesia. Bilateral vagotomy and administration of hexamethonium abolish the tachycardia. These observations demonstrate the presence of a vagally mediated chronotropic effect which becomes manifest when the inhibitory vagal effect is eliminated through blockade of the muscarinic receptors with atropine.

Anesthesia

Spectrophotometric determination of oxygen saturation of blood independent of the presence of indocyanine green.

The strong absorbance of indocyanine green in a broad band around lambda = 800 nm invalidates the usual spectrophotometric two-wavelength methods for measuring oxygen saturation operating in the red and near infrared region. By proper wavelength selection, however, the effect of the dye can be eliminated. With the two-wavelength method utilising lambda = 660 and 860 nm oxygen saturation is measured virtually independent of the presence of indocyanine green.

Animals

A new reference method for the determination of the total CO2 concentration in biological fluids.

It appeared that a part of a measuring system recently developed for the determination of the oxygen content of blood (Dijkhuizen, P., Kwant, G. and Zijlstra, W.G. (1976) Clin. Chim. Acta 68, 79), was perfectly suitable for measuring the total CO2 content of blood, plasma or other fluids. CO2-free room air is pumped through an extraction vessel in which all the CO2 of the sample is set free by an acid reagent, and swept by the carrier gas to a titration vessel containing a BaCl2 solution. CO2 is bound as BaCO3 and the ensuing H+ titrated with an NaOH solution. The method was tested by measuring a series of Na2CO3 reference solutions. The values measured by titration amounted to 99.4 +/- 0.8% of the concentration of the reference solutions (range 10--50 mmol 1(-1). The coefficient of variation was 1.8% for 5 mmol 1(-1) solutions and 0.2% for 50 mmol 1(-1) solutions. In measuring a series of 60 blood samples the coefficient of variation as calculated from duplicate determinations was 1%.

Barium

A fiberoptic reflection oximeter.

A catheter tip oximeter is described consisting of a cardiac catheter containing optical fibers, and incandescent light source, a light detection unit and a processing unit. Half of the optical fibers guide the light to the blood at the tip of the catheter, the other half the backscattered (reflected) light to the detection unit. The detection unit contains a dichroic mirror, transmitting most of the light with lambda less than 800 nm and reflecting most of the light with lambda greater than 900 nm, thus splitting the light into two beams. These pass through interference filters with nominal wavelengths of 640 and 920 nm respectively, and are focused on silicium barrier layer photocells. The photocell signals are amplified and fed into a divider giving the ratio of measuring (R640) and compensating (R920) photocell output. The relationship between log R640/R920 and oxygen saturation is represented by a slightly curved line. The relation may be linearized by subtracting a constant voltage from the divided output before taking the logarithm. The slope of the calibration line is dependent on the total haemoglobin concentration. Nonetheless an average calibration line can be used between 70 and 100% oxygen saturation. For 78 measurements of pig blood samples in this range (haemoglobin concentration between 96 and 161 g.1(-1)), the standard deviation of the difference between the fiberoptic oximeter and a Radiometer OSM1 oxygen saturation meter was 1.9% saturation, for 152 samples over the entire saturation range the standard deviation of the difference was 3.1% saturation. The influence of the flow velocity of blood on the light reflection depends on wavelength as well as on oxygen saturation. Therefore, complete compensation for the flow effect is not possible by simple means.

Animals

Carboxyhaemoglobin. Spectrophotometric determination tested and calibrated using a new reference method for measuring carbon monoxide in blood.

The spectrophotometric determination of HbCO at lambda = 562 and 540 nm in the system HbCO/HbO2 was reinvestigated using a new reference method for measuring CO in blood. This reference method is based on the conversion of CO from HbCO into CO2 which is determined by titration. Plotting the absorbance ratio A562/A540 against the titrimetrically determined HbCO fractions of 46 blood samples demonstrated a linear relationship up to 90% HbCO and yielded more accurate values for the constants in the equation for calculating the HbCO fraction from A562/A540. The standard deviation of the differences between the spectrophotometric and the titrimetric method was 1.2% HbCO. It is shown that the influence of other haemoglobin derivatives and other possible sources of error is either negligible or can be prevented by simple precautions.

Carbon Monoxide

Sulfhaemoglobin. Absorption spectrum, millimolar extinction coefficient at lambda = 620 nm, and interference with the determination of haemoglobin and of haemiglobincy anide.

The spectrophotometry properties of sulfhaemoglobin (SHb) and some derivatives were investigated using an improved technique for measuring the SHb fraction induced in human blood samples. The millimolar extinction coefficient of SHb at lambda = 620 nm was found to be 20.8 (S.D. 1.48; S.E. = 0.44; n = 11). In addition it was demonstrated that the spectral changes occurring in SHb containing haemoglobin solutions upon the addition of KCN, K3Fe(CN)6 and K3Fe(CN)6 +KCN invalidate the KCN addition method for the determination of haemiglobin. The influence of clinically occurring SHb fractions on the internationally standarized total haemoglobin determination were shown to be insignificant.

Ferricyanides