Search PubMed⌕ Search

Biomedical subjects

W F Harris

Publications and source records attributed to W F Harris.

At least 19 recordsLinked to original sources

Sequential tilt and tilted power of thin lenses.

PURPOSE: The purposes of this article were, for any sequence of tilts applied to a thin lens, to calculate an equivalent turn and single tilt, to show how to use the equivalent turn and tilt to calculate the tilted power of the lens, and, given the desired tilted power, to calculate the power of the untilted lens necessary to compensate for the effects of tilt. The untilted lens may be stigmatic (spherical) or astigmatic (spherocylindrical). METHODS: The analysis makes use of rotation matrices to represent rotation in space and previous work in third-order optics on oblique central refraction. RESULTS: Equations are presented for calculating the combination of turn and tilt that is equivalent to any sequence of tilts. They are specialized for the particular case of combinations of faceform and pantoscopic tilts and allow the decomposition of an arbitrary tilt into a combination of turn and pantoscopic and faceform tilts. The equations also lead to a procedure for calculating or compensating for the tilted power of a sequentially tilted thin lens. CONCLUSIONS: Previous work on the effect of tilt on thin lenses has been generalized to handle combinations of arbitrary tilts.

Equipment Design↗

Effect of tilt on the tilted power vector of a thin lens.

PURPOSE: The purpose of this study is to derive the equation for the effect of tilt on the tilted power vector of a possibly astigmatic thin lens. METHODS: The analysis makes use of the equation for tilted power in terms of the dioptric power matrix. RESULTS: A simple equation is obtained for the tilted power vector of a thin lens in terms of the untilted power vector of the lens. A solution of the equation provides a means for compensating spectacle lenses for tilt. Numerical examples are presented in the (available online at www.optvissci.com). CONCLUSIONS: The equation gives insight and is useful for researchers and clinicians working in terms of power expressed as power vectors.

Astigmatism↗

Curvature of ellipsoids and other surfaces.

From differential geometry one obtains an expression for the curvature in any direction at a point on a surface. The general theory is outlined. The theory is then specialised for surfaces that are represented parametrically as height over a transverse plane. The general ellipsoid is treated in detail as a special case. A quadratic equation gives the principal directions at the point and, hence, the principal curvatures associated with them. Equations are obtained for ellipsoids in general that are generalisations of Bennett's equations for sagittal and tangential curvature of ellipsoids of revolution. Equations are also presented for the locations of umbilic points on the ellipsoid.

Humans↗

Error cells for spherical powers in symmetric dioptric power space.

PURPOSE: : The purpose of this article is to analyze the geometry and examine the implications of the error cells of purely spherical powers in symmetric dioptric power space. METHODS: : In the context of spherocylindrical data spherical data typically implies a cylindrical component that is less than some particular amount (often 0.125 D) in magnitude. This error or uncertainty in cylinder is over and above the error in sphere itself. The two components of error are used to define the error cells in symmetric dioptric power space. RESULTS: : Error cells of spherical powers are constructed and presented as stereopairs. They are also shown in relation to error cells of powers in general. CONCLUSIONS: : An understanding of error cells can help the researcher avoid pitfalls in the analysis of spherocylindrical data. Perhaps surprisingly, the error cells of spherical powers are not invariant under spherocylindrical transposition.

Humans↗

Reduction of artefact in scatter plots of spherocylindrical data.

Round-off of spherocylindrical powers, to multiples of 0.25 D (for example) in the case of sphere and cylinder, and 1 or 5 degrees in the case of axis, represents a type of distortion of the data. The result can be artefacts in graphical representations, which can mislead the researcher. Lines and clusters can appear, some caused by moiré effects, which have no deeper significance. Furthermore artefacts can obscure meaningful information in the data including bimodality and other forms of departure from normality. A process called unrounding is described which largely eliminates these artefacts; each rounded power is replaced by a power chosen randomly from the powers that make up what is called the error cell of the rounded power.

Artifacts↗

Realizability of optical systems of given linear optical character.

The linear optical character of an optical system is represented by a particular type of 5 x 5 matrix. This article shows that the converse is also true, namely, that an optical system can be constructed in principle with linear optical character represented by any matrix of this type. In other words, every matrix of this type is realizable as an optical system. The system may have astigmatic and decentered elements.

Linear Models↗

The average eye.

For statistical and other purposes one needs to be able to determine an average eye. An average of refractive errors is readily calculated as an average of dioptric power matrices. A refractive error, however, is not so much a property of the eye as a property of the compensating lens in front of the eye. As such, it ignores other aspects of the optical character of the eye. This paper discusses the difficulties of finding a suitable average that fully accounts for the first-order optics of a set of optical systems. It proposes an average based on ray transferences and logarithms and exponentials of matrices. Application to eyes in particular is discussed.

Eye↗

Stigmatic optical systems.

There would appear to be little disagreement on what constitutes an astigmatic system in the case of a thin lens: the cylinder is not zero. A spherical thin lens is stigmatic or not astigmatic. The issue is less clear in the case of a thick system. For example, is an eye stigmatic merely because its refraction is stigmatic (spherical)? In this article, a system is defined to be stigmatic if and only if, through the system, every point object maps to a point image. Every other system is astigmatic. Thus, a system is astigmatic if and only if there exists a point object for which the image is not a point. This article is restricted to linear optics. The optical character of a system is completely determined by the ray transference of the system. The objective here is to find those conditions on the transference for which the system is stigmatic or astigmatic. The result is that, for a stigmatic system, all the 2 x 2 submatrices are scalar multiples of a common orthogonal matrix. For a system to be stigmatic, it is not sufficient that its power be stigmatic. An eye may be astigmatic despite having a stigmatic refraction.

Astigmatism↗

Proper and improper stigmatic optical systems.

Stigmatic optical systems are of two classes: proper and improper stigmatic systems. The purpose of the article is to explore the nature of the two classes. The image may be rotated in the case of proper stigmatic systems and is reflected in a line in the image plane in improper stigmatic systems. Chirality is preserved through proper stigmatic systems but reversed in improper systems. The image also undergoes magnification that is the same in all meridians and, in the case of decentered systems, a transverse translation. Negative magnification implies inversion in a point. The magnification depends on the distance of the object plane from the system, whereas the rotation and reflection do not. The article shows how to identify a system as astigmatic or proper or improper stigmatic from the transference and how to construct the transference of a system that will achieve a particular magnification and rotation or reflection.

Astigmatism↗

Image size magnification and power and dilation factors for optical instruments in general.

Traditional treatments of spectacle magnification for distant objects consider only stigmatic spectacle lenses and they compare the retinal image size in a refractively fully compensated eye with the image size in the uncompensated eye. Spectacle magnification is expressed as a product of two factors, the power and shape factors of the lens. The power factor depends on the position of the entrance pupil of the eye. For an eye with an astigmatic cornea, however, the position of the entrance pupil is not well defined. Thus, the traditional approach to spectacle magnification does not generalize properly to allow for astigmatism. Within the constraints of linear optics and subject to the restriction that the eye's iris remains the aperture stop, this paper provides a complete, unified and exact treatment for optical instruments in general. It compares retinal image size in a generalized sense (including image shape and orientation) for any instrument in front of an eye with that of the eye alone irrespective of whether the instrument compensates or not. The approach does not make use of the concept of the entrance pupil at all and it allows for astigmatism and for non-alignment of refracting elements in the instrument and in the eye. The concept of spectacle magnification generalizes to the concept of instrument size magnification. Instrument size magnification can be expressed as the product of two matrix factors one of which can be interpreted as a power factor (as back-vertex power) and the other factor for which the name dilation factor is more appropriate in general. The general treatment is then applied to a number of special cases including afocal instruments, spectacle lenses (including obliquely crossing thick bitoric lenses), contact lenses, stigmatic systems and stigmatic eyes. In the case of spectacle lenses, the dilation factor reduces to the usual shape factor.

Astigmatism↗

Proximity factor in image size magnification for optical instruments in general.

A general expression is derived for the proximity factor in near image size magnification for an arbitrary instrument in front of an arbitrary eye. The proximity factor is a 2 x 2 matrix. The instrument and eye may be astigmatic and have decentred elements. The image on the retina may be blurred or not. The analysis is exact within the limitations of linear optics. The general results are specialized for the case of a stigmatic instrument and a stigmatic eye. The results are applied to the case of a thick, possibly bitoric, spectacle lens. The Appendix treats two numerical examples.

Astigmatism↗

Near image size magnification for optical instruments in general.

A previous article derives expressions for coefficients and magnifications for an arbitrary optical instrument in front of an arbitrary eye and for near object points. The purpose of this note is to correct an error in the interpretation of a parameter in that article, to show that the expression derived there for near image size magnification holds only under particular conditions, and to modify the expression so that it holds in general.

Accommodation, Ocular↗

Relation between anterior and posterior converter systems.

A corrected or uncorrected human eye may be astigmatic and noncoaxial. The first-order (i.e., paraxial) character of arbitrary astigmatic and noncoaxial optical systems can be compared quantitatively in terms of the ray transference of either an anterior or a posterior converter system. This article derives equations that give the relationships between the transferences of the anterior and posterior converter systems.

Astigmatism↗

Tilted power of thin lenses.

Tilting changes the effective power of a thin lens. Blendowske has recently provided an elegant matrix expression for the tilted power in the case of tilt about a vertical axis (faceform tilt). He makes use of what can be called a tilt matrix. He shows that the same expression holds in the case of tilt about a horizontal axis (pantoscopic tilt) if one makes use of a different tilt matrix. The purpose of this note is to derive a general tilt matrix that makes Blendowske's equation valid for tilt about any axis. The general tilt matrix reduces to the particular tilt matrices in the case of rotation about the horizontal and vertical axes. The lens may be stigmatic or astigmatic and may be in air or in some other medium.

Eyeglasses↗

Determining the power of a thin toric intraocular lens in an astigmatic eye.

Astigmatism poses a number of special difficulties when attempting to achieve a desirable refractive outcome during cataract surgery and intraocular lens implantation. One of the most pertinent difficulties is that traditional Gaussian theoretical formulas are simply unable to handle general astigmatic optical systems, that is, systems in which the principal meridians of the refracting interfaces do not lie in two mutually orthogonal planes. This means that the traditional approach falls short when the cornea is treated as bitoric or when other toric optical devices are already present in the eye. In this paper, the modified step-along procedure is utilized in a demonstration of the derivation of the traditional Gaussian theoretical formulas for the determination of intraocular lens power in a stigmatic eye. Matrices are then used to derive a general formula for the determination of the power of a thin toric intraocular lens in an astigmatic eye. This formula is then modified to allow the user to determine the power of the secondary intraocular lens required to compensate for any residual refraction in a phakic or pseudophakic astigmatic eye. The formulas hold under all conditions, including the case when the cornea is treated as thick and bitoric and when other toric optical devices are already present in the eye. Worked examples are provided.

Astigmatism↗

Analysis of astigmatism in anterior segment surgery.

PURPOSE: To demonstrate techniques for analyzing astigmatism in the context of anterior segment surgery. The techniques are applied to refractive and corneal astigmatism and to astigmatism associated with the surgery. METHOD: The analysis is based on the 3-dimensional first-order ray optics known as linear optics, in which astigmatism is axial. Anterior segment surgery, whose only direct effect is to change corneal curvature, is optically equivalent to placing a thin lens immediately in front of the (preoperative) eye; the surgery can be described as anterior thin-lens equivalent. In principle, however, surgery may also change the relative axial positions of refracting elements. In such cases, anterior segment surgery is anterior thick-system equivalent and the analysis of astigmatism is considerably more complicated, with astigmatism manifesting in power and in other ways. Fundamentally, the method is based on the ray transference, a 4 x 4 matrix that contains the 4 fundamental optical properties of a system. Each property may contain an antistigmatic component, and it is this component that is analyzed. RESULTS: The data are not consistent with the anterior thin-lens model of anterior segment surgery but rather with the anterior thick-lens model. Many components of refraction and corneal power, their means, and their surgically induced changes were calculated and are presented in tabular and graphical form. Graphical representations include polar profiles and stereo-pair scatterplots in dioptric power space. Results are also presented for all the fundamental properties of the surgery. CONCLUSION: Ocular astigmatism can manifest in more ways than just refraction and corneal power. Traditional approaches, which treat astigmatism as cylinder in some sense and only as manifested in power, are unsatisfactory. In particular, current approaches weight astigmatism too heavily relative to stigmatism and to other optical phenomena and are inadequate for thick systems such as the eye. The ray transference and the 4 fundamental properties it contains provide the basis for the only methods that can adequately cope with analysis of astigmatism in general and in surgically induced astigmatism in particular.

Adult↗

Optical effects of ocular surgery including anterior segment surgery.

Ocular surgery may alter the refraction and the corneal power of an eye. However, refraction and corneal power are not fundamental optical properties of the eye as such. Refraction is a fundamental property of a lens in front of the eye and an indirect or derived property of the eye, while corneal power is a fundamental property of only part of the eye. Nor are they the only clinically relevant paraxial optical effects of surgery. There are also effects on size, shape, and orientation of retinal images, for example, which are not simply related to refraction and corneal power. Quantitative analyses of the effects of surgery on the eye that account only for refraction and corneal power are necessarily incomplete. This paper offers an approach to the analysis of the optical effects of surgery that is complete within the limitations of paraxial optics. The key is the concept of the ray transference, which contains the 4 fundamental optical properties of an optical system. The surgery is represented by a hypothetical optical system, the anterior surgery-equivalent system, in front of the preoperative eye. The transference of this system, the anterior surgical transference, is a complete paraxial quantification of the optics of the surgery and is what needs to be studied in analyses of surgery. In this approach, ocular surgery in general is optically equivalent to a thick system placed in front of the preoperative eye. A simple model is developed for the case of anterior segment surgery in particular. In terms of the model, anterior segment surgery is shown to be equivalent to placing a thick bitoric lens in front of the preoperative eye. In particular cases, the surgery may be equivalent to an anterior thin lens. Astigmatism is an aspect of optical effects in general. It is not directly amenable to quantitative analysis in isolation; quantitative analyses of astigmatism should be done in terms of the concept of antistigmatism. In thin systems, astigmatism manifests only in power. However, in thick systems such as the eye, astigmatism can manifest in 4 fundamentally different ways. Among them are some phenomena currently described as irregular astigmatism. The foundation is laid for the complete analysis of paraxial astigmatism in general and in ocular surgery in particular.

Astigmatism↗