Search PubMedSearch

Biomedical subjects

W E May

Publications and source records attributed to W E May.

10 recordsLinked to original sources

Determination of glycyrrhetinic acid in human plasma by high-performance liquid chromatography.

A high-performance liquid chromatographic (HPLC) method has been developed for measuring 18 beta-glycyrrhetinic acid (GRA) in human plasma in the range of 0.1-3 micrograms/ml. The acetate ester of GRA is added to the plasma as an internal standard, plasma proteins are denatured with urea to release GRA, and the GRA and the internal standard are extracted in an ion-pairing solid-phase extraction process. An isocratic, reversed-phase HPLC separation is used, followed by ultraviolet absorbance detection at 248 nm. The results from the analysis of five GRA-fortified plasma pools show a mean relative standard deviation of 7% and are accurate to within 10%. With evaporative concentration of the extract, the limit of detection for GRA in plasma is approximately 10 ng/ml.

Chromatography, High Pressure Liquid

Chromatographic analysis of hydrocarbons in marine sediments and seawater.

The low concentration of hydrocarbons anticipated in pollution baseline studies necessitates the development of analytical techniques sensitive at the sub-microgram per kilogram concentration level. The method of analysis developed in this laboratory involves dynamic headspace sampling for volatile hydrocarbon components of the sample, followed by coupled-column liquid chromatography for the non-volatile components. These techniques require minimal sample handling, reducing the risk of sample component loss and/or sample contamination. Volatile sample components are separated from the matrix in a closed system and concentrated on a TENAX-GC packed pre-column, free from large amounts of solvent and ready for GC/GC-MS analysis. Non-volatile compounds, such as the benzpyrenes, may be extracted from large volumes of water and concentrated on a Bondapak C18 packed pre-column for coupled-column liquid chromatographic separation and analysis. Results of the application of these techniques to the analysis of samples from sites of known low level hydrocarbon contamination are presented and discussed.

Chromatography

Design and implementation of a collaborative study of the mutagenicity of complex mixtures in Salmonella typhimurium.

In 1987, the International Programme on Chemical Safety (IPCS) in collaboration with the U.S. Environmental Protection Agency (U.S. EPA) and the U.S. National Institute of Standards and Technology (U.S. NIST) initiated an international collaborative study of the mutagenicity of complex environmental mixtures in the Ames Salmonella typhimurium mutation assay. The objectives of this study were: (1) to estimate the inter- and intra-laboratory variability associated with the extraction of mixtures for bioassay, (2) to estimate the inter- and intra-laboratory variability associated with the Salmonella typhimurium bioassay when applied to complex mixtures, and (3) to determine whether standard reference complex mixtures would be useful in mutagenicity studies and to evaluate whether reference or certified mutagenicity values determined from this collaborative study should be reported. The complex mixtures used in this study were selected from standard reference materials (SRMs) which had previously been issued by the U.S. NIST as SRM 1597 (coal tar), SRM 1649 (diesel particulate matter) and SRM 1650 (urban air particulate matter) with certified values for polycyclic aromatic hydrocarbons. These SRM complex mixtures are available to scientists as reference standards for analytical chemistry research and are under consideration as SRMs for mutagenicity studies of complex environmental mixtures. This paper briefly describes the final study design, protocol, selection of the complex mixtures, and implementation of this international study.

Laboratories

Standard reference materials for chemical and biological studies of complex environmental samples.

Standard Reference Materials (SRMs) from the National Institute of Standards and Technology (NIST) are often used in methods development and interlaboratory comparison studies since they are homogeneous and readily available to the scientific community. SRM 1649 (urban dust/organics), SRM 1650 (diesel particulate matter), and SRM 1597 (complex mixture of polycyclic aromatic hydrocarbons from coal tar) are three environmental samples which have been used by the scientific community for these purposes. These SRMs were originally developed to assist laboratories in validating analytical procedures for the determination of polycyclic organic compounds in complex mixtures. In addition, these SRMs have been valuable for the comparison of methodologies for bacterial bioassays and the development of bioassay-directed fractionation and bioassay-directed chemical analysis techniques. Most recently these SRMs were chosen for use as test samples in a collaborative study coordinated by the World Health Organization--International Programme on Chemical Safety. This paper provides a summary of much of the work to date (published and unpublished) on the chemical and biological characterization of these three SRMs. Information regarding the availability of other NIST SRMs that might be useful for these types of studies are provided also.

Air Pollutants