Search PubMed⌕ Search

Biomedical subjects

W Dietrich

Publications and source records attributed to W Dietrich.

At least 55 records · Page 3Linked to original sources

Growing blood clot mimicking an aneurysm on postoperative computerized tomography and magnetic resonance imaging studies. Case report and review of the literature.

The authors describe the case of a 15-year-old boy who underwent resection of a large left temporal tumor. During a normal postoperative course, computerized tomography (CT) scanning demonstrated a spherically hyperdense structure near the internal carotid artery, enlarging on a control CT scan. A suspected false aneurysm was confirmed on magnetic resonance imaging; angiographic studies were negative. The authors believed they were dealing with a thrombosed false aneurysm and they performed operative revision. Intraoperatively the "aneurysm" could be dissected off the internal carotid artery and no lesion of the arterial wall was obvious. Histological findings showed a fresh blood clot. This case demonstrates that a blood clot may mimic an aneurysm on CT and magnetic resonance studies, which has not been described earlier. The origin of the blood clot remains unclear.

Adolescent↗

[Effect of stomach motility on measuring stomach permeability with saccharose in vivo].

Determination of the urinary excretion of sucrose after an oral dose has been used as a noninvasive test to measure gastric permeability in several clinical studies. Regarding different contact times of sucrose solution within the gastric mucosa, the present study investigates a possible influence of the gastric emptying rate on the sucrose permeability test. Urinary sucrose excretion and the gastric emptying rate of liquids using 13C-acetate breath test were determined in twelve healthy volunteers. Furthermore, in seven volunteers gastric emptying was accelerated by intravenous erythromycin and prolongated by oral anticholinergic propantheline in nine healthy controls. Breath samples were measured using infrared spectroscopy. The half-emptying time and Lag-phase were correlated with the urinary sucrose excretion. Erythromycin caused a significant (p = 0.02) reduction of the half-emptying time (median 35.0 min) compared with untreated controls (median 59.9 min), whereas propantheline significantly increased the half-emptying time (median 69.4 min, p = 0.01). After pharmacological increase of the half-emptying time the urinary sucrose excretion only slightly differs from the sucrose excretion of controls (median [range] 0.057 [0.034-0.106]% versus 0.031 [0.017-0.162]%), but there was an increase of urinary sucrose excretion in probands following reduction of the half-emptying time with erythromycin (0.077 [0.023-0.221]%. The present study shows that gastric motility has a possible influence on the sucrose permeability test. The sucrose permeability has to be interpreted critically concerning its clinical use especially in patients with altered gastric motility.

Adult↗

Influence of high- and low-dose aprotinin on activation of hemostasis in open heart operations.

BACKGROUND: The protease inhibitor aprotinin reduces hemostatic activation and blood loss after cardiac operations. The aim of the present study was to investigate the influence of two different aprotinin doses on hemostatic activation and to identify the most effective dose to reduce the postoperative bleeding tendency. METHODS: In a prospective, randomized, double-blind clinical trial, 230 patients scheduled for routine open heart operations received either high-dose (group H) or low-dose (group L) aprotinin. Primary outcome measures were the level of F(1+2) prothrombin fragments as a marker of thrombin generation, the level of D-dimers as an indicator of fibrinolysis, and the amount of postoperative blood loss. Allogeneic blood transfusion was recorded as a secondary outcome measure. RESULTS: Aprotinin plasma concentrations 5 minutes after the onset of cardiopulmonary bypass were 166 +/- 45 kallikrein inactivator units per milliliter in group H and 118 +/- 30 kallikrein inactivator units per milliliter in group L (p < 0.05). Fibrinolytic activation was reduced significantly in group H compared with group L: the level of D-dimers at the end of CPB was 1,027 +/- 781 ng/mL and 1,977 +/- 1,001 ng/mL, respectively, in the two groups (p < 0.05). However, thrombin generation (F(1+2) fragments) did not differ between the two groups (7.4 +/- 3.5 nmol/L in group H and 8.6 +/- 4.3 nmol/L in group L). Twenty-four-hour postoperative blood loss was 663 +/- 461 mL in group H compared with 877 +/- 513 mL in group L (p < 0.05), and the corresponding allogeneic blood requirement was 1.3 +/- 1.9 U in group H and 1.9 +/- 2.3 U in group L (p < 0.05). CONCLUSIONS: A high-dose aprotinin regimen was significantly more effective than a low-dose regimen in attenuating fibrinolysis and reducing the bleeding tendency and allogeneic blood requirements, but not in reducing F(1+2) prothrombin fragments. High-dose aprotinin therapy appears to be superior to low-dose therapy.

Aprotinin↗

Activation of hemostasis during cardiopulmonary bypass and pediatric aprotinin dosage.

BACKGROUND: Cardiopulmonary bypass results in inappropriate activation of the coagulation and fibrinolytic systems. Factors such as a greater degree of hemodilution, use of deep hypothermic circulatory arrest, the impact of cyanosis on coagulation, and the immature coagulation system of the newborn will increase the risk of problematic perioperative bleeding. METHODS: This article describes the characteristics of the hemostatic system in children undergoing cardiac operations and addresses the effect of aprotinin on hemostasis. Hemostatic parameters were measured in 96 pediatric patients using three different doses of aprotinin. The high-dose group (group 1) received 30,000 KIU/kg (4.2 mg/kg) of aprotinin after induction of anesthesia and an additional bolus of 30,000 KIU/kg (4.2 mg/kg) into the pump prime. In the low-dose group (group 2), both the initial bolus and the pump-prime dose of aprotinin were halved to 15,000 KIU/kg (2.1 mg/kg). Group 3 received the high dose with an additional bolus of aprotinin to the pump prime. RESULTS: Plasma levels of aprotinin in both groups 1 and 2 were lower than the 200 KIU/mL (0.03 mg/mL) value usually reached in adults with high-dose aprotinin treatment. Group 3 patients had levels greater than 200 KIU/mL (0.03 mg/mL) throughout the procedure. Biochemical indices of fibrinolysis (fibrin[ogen] degradation products, D-dimers) revealed significant and dose-dependent inhibition at all three aprotinin concentrations. In contrast, significant changes in coagulation activation markers (prothrombin fragments F1.2, thrombin-antithrombin III complex, and fibrin monomers) were found only in group 3. CONCLUSIONS: The inverse relationship between a small patient's blood volume and the large pump-prime volume requires additional aprotinin to be added to the prime to achieve plasma levels sufficient to inhibit activation of the coagulation cascade.

Age Factors↗

Incidence of hypersensitivity reactions.

BACKGROUND: Aprotinin is a naturally occurring serine protease inhibitor derived from bovine lung. In common with all foreign proteins, it possesses antigenic properties and has the possibility of allergic reactions on reexposure. METHODS: Data are presented on the incidence of adverse reactions to aprotinin and the time course of antibody development after initial exposure. Recommendations for reducing the risk and sequelae of these adverse reactions are emphasized and case reports are reviewed. RESULTS: The incidence rates of aprotinin-related reactions to date (May 1997) at the German Heart Center are 2.7% in the adult population in reexposures (5/183) and 1.2% in the pediatric population (3/254), with an overall incidence of 1.8% (8/437). CONCLUSIONS: With the recommended precautions, reexposure to aprotinin in patients with a high risk of bleeding is justified, and the benefits of aprotinin treatment outweigh the relative risk of a serious allergic reaction.

Adolescent↗

Frameless stereotactic lesion contour-guided surgery using a computer-navigated microscope.

BACKGROUND: The Zeiss MKM System is a recently developed computerized operating microscope for image-guided neurosurgery. The clinical advantages, reliability, accuracy, and limitations of this technique were investigated. METHODS: Since February 1995, 78 consecutive frameless stereotactic image-guided procedures were performed in 73 patients (30 males, 43 females; mean age, 46.9 years; range, 16-77 years) for tumor surgery (50/64.1%), cavernoma removal (16/20.5%), and functional procedures (12/15.4%). Skin markers (74 cases) or bone markers (4 cases) and a standard imaging protocol (2-mm cranial computed tomography (CCT) in 59 cases/1.5-mm magnetic resonance imaging (MRI) in 19 cases) were used. RESULTS: The main advantages were pre-operative skin incision, craniotomy and corticotomy planning, and determination of lesion boundaries. Useful registration and system reliability were noted in 97% (76/78) of the procedures. A significant improvement in registration accuracy was observed over the test period from a mean of 4.8 mm (SD = 3.36; Cases 1-25) to a mean of 2.2 mm (SD = 0.86; Cases 26-78). This resulted in an improvement in application accuracy from <5 mm in 71% (Cases 1-25) to <2 mm in 95% (Cases 26-78) of cases, and the accuracy led to successful localization of the lesion in every case. Accuracy was reliable at the beginning of every procedure, but degraded to values >5 mm by the end of the procedure in 29% (22/78) of cases. MRI cases achieved higher application accuracy values (2.1 mm mean) than CT cases (3.7 mm mean). CONCLUSIONS: The system offers a reliable alternative to frame-assisted stereotactic craniotomies in lesion targeting, but would need an intraoperative image update for resection guidance.

Adolescent↗

Image-guided neurosurgery comparing a pointer device system with a navigating microscope: a retrospective analysis of 208 cases.

A retrospective analysis of neuronavigation procedures performed at the Vienna Neurosurgical Clinic was undertaken to elucidate the advantages of 2 technically different navigation systems in clinical use. In a 30-month period, 208 frameless stereotactic procedures were performed using a stereotactic microscope (MKM System, Zeiss; 92 procedures in 87 patients; 47 female, 40 male; mean age, 46 yrs) and a light emitting diode (LED) based pointer navigation device (Easy Guide Neuro (EGN), Philips; 116 procedures in 114 patients; 63 female, 51 male; mean age 46.4 yrs). The navigating microscope was exclusively used for cranial navigation, the pointer device system in 107 cases for cranial and in 9 cases for spinal navigation. Procedures were CCT-guided in 109 cases, MRI-guided in 95, and both CT/MRI guided in 4 cases. Skin fiducials were used in all these procedures. The MKM system provided coordinate-based navigation, similar to frame systems. This allowed surgical planning and performance using stereotactic coordinates for target calculation. Additionally, tumor volumes were defined by contours and projected into the ocular of the microscope, allowing guidance during targeting and resection of lesions. Both of these features proved beneficial in tumor surgery (60.8% MKM cases), cavernoma surgery (21.8% MKM cases), and epilepsy surgery (14.1% MKM cases). In contrast to the microscope, the pointer navigation system could be employed for intuitive correlation of image points with points of interest in the operating field by using a LED-equipped pointer device. This permitted image guidance during a wide spectrum of neurosurgical procedures, in tumor surgery (68.1% EGN cases), cavernoma surgery (5.1% EGN cases), epilepsy surgery (14.1% EGN cases), vascular surgery (3.4% EGN cases), spinal surgery (7.8% EGN cases), and guidance for burr holes and drainages (6.9% EGN cases), without calculating stereotactic coordinates. This analysis showed clear differences in the application of the two systems and may facilitate the decision as to which system best meets the individual demands of a neurosurgical department.

Adult↗

Frameless stereotactic-directed tissue sampling during surgery of suspected low-grade gliomas to avoid histological undergrading.

Detection of anaplastic tumor foci for precise grading of gliomas is crucial for prognostic assessment and appropriate postoperative treatment planning. To avoided undergrading in large suspected low-grade gliomas, we employed frameless sterotaxy during open surgery for tissue sampling of radiologically suspected anaplastic foci. In nine patients (mean age 44 years, range 10-67) with large supratentorial suspected low-grade gliomas (32.4 ccm mean vol, range 17.9-68.6 ccm) with small contrast enhancing areas (7.7% mean of total volume, range 0.7-15.3%), a neuronavigation system with a pointer device (Easy Guide System Philips) or a navigating microscope (MKM System Zeiss) was used to target small enhancing tumor parts for cytological investigation during open surgery. Consecutive cytological smears revealed anaplastic tumor foci in all patients, correlating with neuroradiologically demonstrated small contrast enhancing areas, although biopsies from all other tumor parts showed low-grade tumors. Final neuropathological diagnosis confirmed anaplasia within the neuroradiologically suspected low-grade gliomas in all patients (2 grade IV, 5 WHO grade III and 2 grade II-III tumors, WHO classification). In our experience frameless stereotactic-directed intraoperative tissue sampling during open surgery of large suspected low-grade gliomas helps to identify small anaplastic areas in mostly large low-grade tumors, and therefore, permits optimum planning of postoperative treatment.

Adolescent↗

The arterial to end-tidal carbon dioxide gradient increases with uncorrected but not with temperature-corrected PaCO2 determination during mild to moderate hypothermia.

UNLABELLED: End-tidal carbon dioxide (PETCO2) monitoring is recommended as a basic standard of care and is helpful in adjusting mechanical ventilation. Gas solubility changes with temperature, which might affect the PaCO2 and thereby the gradient between PaCO2 and PETCO2 (PA-ETCO2) under hypothermic conditions. We investigated whether the PA-ETCO2 changes during mild to moderate hypothermia (36 degrees C-32 degrees C) using PaCO2 measured at 37 degrees C (uncorrected PaCO2) and PaCO2 corrected to actual body temperature. We preoperatively investigated 19 patients. After anesthesia had been induced, controlled ventilation was established to maintain normocarbia using constant uncorrected PaCO2 to adjust ventilation (alpha-stat acid-base regimen). Body core temperature was reduced without surgical intervention to 32 degrees C by surface cooling. Continuous PETCO2 was monitored with a mainstream PETCO2 module. The PA-ETCO2 was calculated using the uncorrected and corrected PaCO2 values. During body temperature reduction from 36 degrees C to 32 degrees C, the gradient between PETCO2 and uncorrected PaCO2 increased 2.5-fold, from 4.1 +/- 3.7 to 10.4 +/- 3.8 mm Hg (P < 0.002). The PA-ETCO2 remained unchanged when the corrected PaCO2 was used for the calculation. We conclude that when the alpha-stat acid-base regimen is used to adjust ventilation, the PA-ETCO2 calculated with the uncorrected PaCO2 increases and should be added to the differential diagnosis of widened PA-ETCO2. In contrast, when the corrected PaCO2 is used for the calculation of the PA-ETCO2, the PA-ETCO2 remains unaltered during hypothermia. IMPLICATIONS: We investigated the impact of induced hypothermia (36 degrees C-32 degrees C) on the gradient between PaCO2 and PETCO2 (PA-ETCO2). The PA-ETCO2 increased 2.5-fold when CO2 determinations were not temperature-corrected. Hypothermia should be added to the differential diagnosis of an increased PA-ETCO2 when the alpha-stat acid-base regimen is used.

Adult↗

Frameless stereotactic guided neurosurgery: clinical experience with an infrared based pointer device navigation system.

An infrared based frameless stereotactic navigation device (Easy Guide Neuro) was investigated for its clinical applicability, registration/application accuracy and limitations in a standard operating room set-up. In a five-month period 40 frameless stereotactic procedures (23 female, 17 male, mean age 46.4, yrs range 10-83) including 36 craniotomies and 4 spinal surgery procedures were performed. Image registration, data transfer and operation planning using skin fixed fiducials (between 5-10, mean 6.6) and CCT in 12 patients/MRI in 28 patients, generally was done the day before surgery. Clinical applicability was proven in all procedures with an additional time for pre-operative imaging and system application in the OR of 50 min mean (35-120 range). A useful registration was achieved in 39/40 patients (97.5%) with a registration accuracy of 3.4 mm (range 1.8-6.7) for brain surgery cases and 14.4 mm (6.8-25) for spine cases. This resulted in intra-operative application accuracy values for brain surgery of 4.2 mm mean (range 1-12). Enhanced registration/application accuracy values over the test period from 4.2/3.8 mm mean (Cases 1-20) up to 3.2/2 mm mean (Cases 21-40) was observed. In spinal surgery an application accuracy of 11.3 mm mean (range 5-20) was found. An intra-operative re-calibration because of system-head drift was necessary in none of the patients, nevertheless, application accuracy degradation due to brain shift was detected in every case. In conclusion, the system allowed a time sufficient accurate frameless intra-operative localisation guidance in cavernoma, meningioma, glioma, and brain metastasis surgery. In spinal surgery, the application accuracy exceeded clinical usefulness due to high registration inaccuracy using skin markers.

Adolescent↗

Prevalence of anaphylactic reactions to aprotinin: analysis of two hundred forty-eight reexposures to aprotinin in heart operations.

The efficacy of aprotinin to reduce intraoperative bleeding tendency in cardiac operations has been demonstrated in several studies. Aprotinin is a polybasic polypeptide and has antigenic properties. Anaphylactic reactions to aprotinin have been described. The aim of the present study was to evaluate the prevalence of adverse reactions to reexposure to high-dose aprotinin. The clinical outcome of all patients undergoing heart operations in our institution between 1988 and 1995 with at least two exposures to aprotinin was investigated. There were 248 reexposures to aprotinin in 240 patients: 101 adult and 147 pediatric cases. The total aprotinin doses were 4.9 x 10(6) (interquartile range 2 x 10(6)) KIU (adults) and 1.3 x 10(6) (interquartile range 1.2 x 10(6)) KIU (pediatric patients). The time between the first and second aprotinin exposures was 344 (interquartile range 1039) days. Seven adverse reactions to aprotinin were found (2.8%). The severity of the reaction ranged from mild (no intervention) to severe (longer-lasting circulatory depression despite vasopressor therapy). All patients survived the event. Patients with an interval less than 6 months since the previous exposure had a statistically higher incidence of adverse reactions than patients with a longer interval (5/111 or 4.5% vs 2/137 or 1.5%, p < 0.05). Two patients reacted to a test dose of 10,000 KIU aprotinin. Pretreatment with antihistaminics was done in 60% of the patients. We recommend the following procedure for reexposure with high-dose aprotinin: (1) delay of the first bolus injection of aprotinin until the surgeon is ready to begin cardiopulmonary bypass, (2) test dose of 10,000 KIU aprotinin in all patients with aprotinin treatment, (3) H1/H2 blockade in known or possible reexposures, and (4) avoidance of reexposure within the first 6 months after the previous exposure to aprotinin. With these precautions a reexposure to aprotinin in patients with a high risk of bleeding is justified, because the benefits of aprotinin treatment outweigh the relative risk of a serious allergic reaction.

Adolescent↗

Recurrent aneurysmal subarachnoid haemorrhage: bleeding pattern and incidence of posthaemorrhagic ischaemic infarction.

This report is based on a consecutive series of 162 patients with aneurysmal subarachnoid haemorrhage (SAH), including 22 patients (14%) with recurrent SAH, who were treated within 72 h after the most recent bleed. Of the 22 patients with recurrent haemorrhage: 68% were in poor clinical condition (Hunt & Hess grade 4-5); 73% presented with intracerebral haemorrhage (ICH); 41% developed delayed ischaemic infarctions from chronic arterial spasm; 14% made a good recovery, while 41% died. Of the 140 patients with a single bleed: 34% were in poor clinical condition (Hunt & Hess grade 4-5); 33% presented with ICH; 22% developed delayed ischaemic infarctions; 53% made a good recovery, while 19% died. Our results suggest that a high incidence of intracerebral haemorrhage in conjunction with a more severe course of chronic arterial spasm substantially contributes to the high morbidity and mortality associated with recurrent SAH. In poor grade patients not suitable for acute open surgery, endovascular treatment should receive consideration for the prevention of early rebleeding.

Adolescent↗

Contour-guided brain tumor surgery using a stereotactic navigating microscope.

OBJECTIVE: The benefit of intraoperative radiological data integration in approach planning and resection of brain tumors using a computer navigating microscope (MKM Zeiss) was investigated. METHODS: Since February 1995, out of 86 MKM-guided surgical procedures, 53 contour-guided tumor cases (24 females, 29 males, mean age 51.6) including 16 metastasis, 14 glioblastomas, 10 low-grade gliomas, 6 anaplastic gliomas, 3 meningiomas and 4 others were performed. The preoperative planning was based on CT in 42 cases and Magnetic Resonance Tomography (MRT) in 11 cases using skin markers (4-9, mean 6). Neuroradiologically defined tumor contours were transferred into the ocular of the microscope and projected into the operating field during the procedure. RESULTS: The advantages of the system were: (1) preoperative approach planning; (2) minimal, accurate skin incision and craniotomy; (3) intraoperative detection of deep seated lesions or lesion components; (4) determination of lesion boundaries; (5) minimized traumatization in/near eloquent areas. Mean registration accuracy improved from 5.3 mm for the first 10 cases up to 2 mm for the last 18 cases. In glioma surgery, the system provided exact definition of radiologically planned resection borders. In meningioma surgery, it allowed a tailored craniotomy, dura opening and resection, lowering the risk of recurrence. In metastasis surgery, it provided a safe approach to deep and eloquent located lesions. CONCLUSION: Contour-guided operation planning and resection guidance using the investigated navigating microscope provides additional security to avoid some potential risks in brain tumor surgery.

Adult↗

Reducing thrombin formation during cardiopulmonary bypass: is there a benefit of the additional anticoagulant action of aprotinin?

During cardiopulmonary bypass (CPB), contact-phase activation of factor XII, prekallikrein, and high molecular weight kininogen initiates the intrinsic pathway of coagulation. To prevent gross clot formation during CPB, heparin is commonly used as an anticoagulant. There is a wide variability in the sensitivity of individual patients to the actions of heparin. We did not find a significant correlation between plasma heparin levels and concentrations of D-dimers, thrombin-antithrombin III complexes (TAT), and prothrombin fragments F1+2 as markers of fibrinolysis and coagulation activation. In addition, heparin cannot completely inhibit thrombin formation and action and may play a central role in the coagulation disorders associated with CPB. F1+2 and TAT rise throughout the course of CPB and fibrin monomers are generated. Attempts to improve anti-coagulation using heparin-coated bypass circuits and specific inhibitors of thrombin have not thus far proven successful. The serine protease inhibitor aprotinin can inhibit contact-phase activation, as evidenced by generation of significantly fewer prothrombin fragments F1+2, thrombin-antithrombin III complexes, fibrinopeptide A, and fibrin monomers in aprotinin-treated patients undergoing cardiac surgery. Studies performed with a simulated CPB system have shown attenuation of plasma kallikrein C1 inhibitor complex (PKC1 I) with aprotinin and the recombinant Arg 15 aprotinin. This action of aprotinin to inhibit contact-phase activation may influence the degree of anticoagulation with heparin. Patients treated with aprotinin require approximately 20% less heparin to achieve an activated clotting time (ACT) of 400 s than control patients. Despite lower plasma concentrations of heparin, aprotinin-treated patients had significantly lower concentrations of the markers of coagulation activation (thrombin-antithrombin III complex, fibrin monomers, and antiplasmin-plasmin complex). We have also investigated the role of aprotinin in contact-phase [correction of contact phase] activation of fibrinolysis. Patients treated with aprotinin showed higher concentrations of single-chain urinary type plasminogen activator (scuPA) at the end of CPB compared with control patients, indicating reduced contact- phase [correction of contact phase] activation.

Anticoagulants↗

Analysis of the in vitro secretory activity of human pituitary adenomas: modification of corticotropin release from adenoma tissue explant cultures by addition of a human plasma ultrafiltrate bioactive fraction.

The lack of control of tumour behaviour is manifested in different ways, depending primarily on the type of tumour. This results in numerous problems of tumour diagnosis and therapy. In the case of "benign" tumours, like pituitary adenomas, in vitro studies are often used for evaluation of the tumour. The use of tissue explant cultures of human pituitary adenomas and the comparison of the feature of cultured tumours with their behaviour in vivo showed that corticotropin is released not only from the tumours associated with Cushing's disease, but also from clinically non-functioning tumours. Hence, it was supposed that the release of corticotropin in vivo from non-secreting tumours is probably under the influence of certain neuroendocrine and/or systemic humoral factors. To test this possibility, samples of 22 tumours were cultured in plain culture medium or in the presence of the "human plasma ultrafiltrate bioactive fraction" (tentatively termed as TBP) prepared by anion-exchange chromatography. In the presence of TBP the release of corticotropin was strongly inhibited in adenomas showing relatively high spontaneous secreting activity in vitro (> 200 ng/l in 24 hours), while immunohistochemistry of these tumours indicated accumulation of corticotropin inside the cells. In contrast, TBP stimulated corticotropin release from tumours that showed relatively low basic corticotropin release (< 200 ng/l in 24 hours), with no obvious change in cellular corticotropin immunoreactivity. Such a dual activity of TBP was not observed for 8 samples of adenomas cultured in the presence of surrounding pituitary tissue, probably because TBP did not affect corticotropin secretion by the normal pituitary cells (as indicated by immunohistochemistry). From these results, it appears that TBP could be one of the humoral factors involved in the regulation of corticotropin release from pituitary adenoma tissue. Its possible involvement in the regulation of corticotropin release from normal pituitary tissue, however, is uncertain.

Adenoma↗