Search PubMed⌕ Search

Biomedical subjects

W DeBois

Publications and source records attributed to W DeBois.

4 recordsLinked to original sources

MAST system: a new condensed cardiopulmonary bypass circuit for adult cardiac surgery.

There have been many refinements in cardiopulmonary bypass (CPB) techniques over the past few decades specific to design, materials and function. Despite these improvements, use of the standard length circuit tubing and pump oxygenator alter cellular, biochemical and rheological properties by inducing a systemic inflammatory response, persisting well into the early postoperative phase. We have designed a new condensed CPB circuit, the MAST system, where the oxygenator and the pumps are brought closer to the operating table (within 30 inches) with the help of a series of telescopic swivel steel poles to which they are attached. The control console is retained at the usual remote location of 2ft behind the MAST system. This configuration accomplishes a decrease in tubing length, priming volume and blood circulatory time within the extracorporeal circuit. Early experience of a hundred consecutive cases utilizing the MAST CPB system is presented along with a comparative analysis of prime volume, hemodilution and transfusion parameters of MAST system vs the low prime system, which is another newly developed CPB circuit utilizing a pediatric oxygenator to reduce prime volume and hemodilution.

Adult↗

Isolated extra-corporeal coronary perfusion circuit for use during off-pump coronary artery bypass grafting.

Cardiovascular surgery would not have developed into its present form without the heart-lung machine. In coronary artery bypass grafting (CABG), cardiopulmonary bypass allows accurate, all site, complete revascularization in a way convenient to the surgeon. The aim of this circuit is to find new ways to reduce invasiveness of CABG and to create new basis conditions for successful coronary bypass grafting on the beating heart. Manipulation of the heart compromises collateral coronary flow, especially to critically narrowed coronaries. This circuit standardizes our method for perfusing blood through the coronary bypass grafts with controlled positive pressure as each distal anastomosis is made, and it preserves collateral coronary flow, while facilitating construction of the remaining distal anastomoses.

Cardiopulmonary Bypass↗

Retrograde autologous priming for cardiopulmonary bypass: a safe and effective means of decreasing hemodilution and transfusion requirements.

OBJECTIVES: The obligatory hemodilution resulting from crystalloid priming of the cardiopulmonary bypass circuit represents a major risk factor for blood transfusion in cardiac operations. We therefore examined whether retrograde autologous priming of the bypass circuit would result in decreased hemodilution and red cell transfusion. METHODS: Sixty patients having first-time coronary bypass were prospectively randomized to cardiopulmonary bypass with or without retrograde autologous priming. Retrograde autologous priming was performed at the start of bypass by draining crystalloid prime from the arterial and venous lines into a recirculation bag (mean volume withdrawal: 880 +/- 150 ml). Perfusion and anesthetic techniques were otherwise identical for the two groups. The hematocrit value was maintained at a minimum of 16% and 23% during and after cardiopulmonary bypass, respectively, in all patients. Patients were well matched for all preoperative variables, including established transfusion risk factors. Subsequent hemodynamic parameters, pressor requirements, and fluid requirements were equivalent in the two groups. RESULTS: The lowest hematocrit value during cardiopulmonary bypass was 22% +/- 3% versus 20% +/- 3% in patients subjected to retrograde autologous priming and in control patients, respectively (p = 0.002). One (3%) of 30 patients subjected to retrograde autologous priming had intraoperative transfusion, and seven (23%) of 30 control patients required transfusion during the operation (p = 0.03). The number of patients receiving any homologous red cell transfusions in the two groups during the entire hospitalization was eight of 30 (27%; retrograde autologous priming) versus 16 of 30 (53%; control) (p = 0.03). CONCLUSIONS: These data suggest that retrograde autologous priming is a safe and effective means of significantly decreasing hemodilution and the number of patients requiring red cell transfusion during cardiac operations.

Aged↗

Intraoperative autologous blood donation preserves red cell mass but does not decrease postoperative bleeding.

BACKGROUND: Postoperative bleeding and transfusion remain a source of morbidity and cost after open heart operations. The benefit of the acute removal and reinfusion of fresh autologous blood around the time of cardiopulmonary bypass-a technique known as intraoperative autologous donation (IAD)-has not been universally accepted. We sought to more clearly evaluate the effects of IAD on allogeneic transfusion and postoperative bleeding by removing, preserving, and reinfusing a calculated maximum volume of fresh autologous whole blood. METHODS: Ninety patients undergoing coronary artery bypass grafting or valvular operations were prospectively randomized to either have (IAD group) or not have (control group) calculated maximum volume IAD performed. Treatment was otherwise identical. Transfusion guidelines were uniformly applied to all patients. RESULTS: An average volume of 1,540 +/- 302 mL of fresh autologous blood was removed and reinfused in the IAD group. Postoperative hematocrits were significantly greater at 12 and 24 hours postoperatively in the IAD group versus the control group despite a significant decrease in both the percentage of patients in whom allogeneic red blood cells were transfused (17% versus 52%; p < 0.01) and the number of red blood cell units transfused per patient per group (0.28 +/- 0.66 and 1.14 +/- 1.19 units; p < 0.01). Conversely, chest tube output, incidence of excessive postoperative bleeding, postoperative prothrombin time, and platelet and coagulation factor transfusion requirement did not differ between groups. CONCLUSIONS: These results indicate that intraoperative autologous donation serves to preserve red blood cell mass. Its routine use in eligible patients is therefore justified. However, the removal and reinfusion of an individually calculated maximum volume of fresh autologous blood had no effect on postoperative bleeding or platelet and coagulation factor transfusion requirement. This lack of hemostatic effect belies the beliefs of many about the primary action of IAD, helps to delineate the optimal way in which to perform IAD, and carries implications regarding the use of allogeneic platelet and coagulation factors for the treatment of early postoperative bleeding.

Adult↗