Search PubMed⌕ Search

Biomedical subjects

W Bautz

Publications and source records attributed to W Bautz.

At least 55 records · Page 3Linked to original sources

Gamna-Gandy bodies of the spleen detected with MR imaging: a case report.

We report a case of a female patient with portal hypertension due to liver cirrhosis. In this case, MR imaging revealed small siderotic nodules of the spleen, called Gamna-Gandy bodies. These lesions are found in patients with portal vein or splenic vein thrombosis, hemolytic anemia, leukemia, or lymphoma, patients receiving blood transfusions, acquired hemochromatosis, or paroxysmal nocturnal hemoglobinuria. There are only few reports in the literature about these siderotic nodules which are not very familiar. MR imaging seems to be the superior imaging method for detection of these lesions. It is important to consider Gamna-Gandy bodies in the differential diagnosis of portal hypertension and the other diseases mentioned above.

Aged↗

[Dose reduction in spiral-CT: detection of pulmonary coin lesions with and without anatomically adjusted modulation of tube current].

PURPOSE: To investigate the potential of projection angle-dependent anatomical adaptation of tube current to reduce dose in spiral CT examinations of the thorax without loss in detectability of pulmonary nodules and image quality. PATIENTS AND METHODS: Dose can be reduced for non-circular patient cross-sections without an increase in noise if the tube current is reduced at those angular positions where the patient diameter and, consequently, attenuation are small. The examinations were dose with SOMATOM Plus 4 (Siemens AG). CT projection data were analysed to determine the optimum tube current for each projection angle in real time. We compared image quality, done, and detection rates of pulmonary nodules for thoracic spiral CT examinations with and without online anatomically adapted tube current control in a group of 38 patients. Three radiologists counted all intrapulmonary nodules in consensus separated in three different groups (< 5 mm, 5-10 mm, > 10 mm). Image quality was evaluated in a scale from 1-3 (1 = very good, 2 = good, 3 = worse). RESULTS: On average, the dose was reduced by 21% (15-34%). With a constant tube current, 704 pulmonary nodules were detected, with tube current modulation 707 pulmonary nodules. For three patients we saw more pulmonary nodules (five) with tube current modulation, for two patients we saw less pulmonary nodules (two). In a direct comparison, the missed intrapulmonary nodules were also detected in the respective method. Thus, the detection rate of intrapulmonary nodules was uninfluenced. In general, no deterioration of image quality was observed. CONCLUSION: On average, 21% dose reduction was achieved by an anatomically adapted tube current modulation in spiral CT examinations of the thorax without a loss in detectability of pulmonary nodules and image quality. This method is an important contribution to dose reduction in spiral CT.

Diagnosis, Differential↗

[CT-guided percutaneous core biopsy: Effective accuracy, diagnostic utility and effective costs].

PURPOSE: The value of a diagnostic technique does not only depend on its sensitivity, specificity and accuracy, but also on how its results affect clinical management. This effect is represented by the values effective accuracy and the diagnostic utility which were determined for CT-guided coaxial core biopsies in this study. MATERIALS AND METHODS: 180 consecutive biopsies were analyzed. The results were analyzed with the help of a logistic regression analysis with regard to the organ regions biopsied, the size of the needle used, and the number of tissue cores taken. Correct results that were not accepted as diagnostic clinically and resulted in additional biopsies were scored together with the false results under negative utility coefficients. RESULTS: The sensitivity, specificity and accuracy of all the tests amounted to 91.1 %, 100 %, and 93.3 %, respectively. The diagnostic utility of the biopsies varied between 66 % for the liver and pancreatic lesions, and 88 % for the non-organ related retroperitoneum. In those cases where more than three tissue cores were taken the results were statistically significantly better in terms of effective accuracy and diagnostic utility. No significant differences were found with regard to different needle sizes in the biopsied organ regions. The lowest clinical acceptance was observed for the histological findings "scar tissue" and "inflammation". CONCLUSION: CT-guided coaxial biopsies offer a high degree of sensitivity, specificity and accuracy, as well as a low rate of therapeutically relevant complications. With increasing use of differentiated strategies in therapy for malignomas percutaneous biopsies play a very important role in the management of these diseases. Prospective studies should further evaluate the effective accuracy and diagnostic utility of core biopsies also in comparison to fine needle aspiration biopsies (FNAP).

Adult↗

[Fully automated floating table MR angiography of pelvic and leg arteries: initial clinical results].

The aim of this study was to obtain first clinical experiences with magnetic resonance angiography (MRA) with digital subtraction (MR-DSA) using an automatic floating table for visualization peripheral arteriosclerotic occlusive disease (paod). We examined 10 patients on a 1.5 T MR unit applying a fast MRA technique (3D FLASH) with intravenous application of positive contrast agent. MR-DSA examinations were compared with the gold standard intraarterial (i.a.) DSA. MR-DSA proved to be useful for routine application which could be performed sufficiently in all patients. MR-DSA and i.a. DSA showed comparable results for imaging of the pelvic and upper leg arteries. Looking at the thighs image quality of MR-DSA did not match the image quality of i.a. DSA in every case. This was due to venous overlap and in comparison to i.a. DSA reduced signal-to-noise ratios. However, clinical findings, obtained with MR-DSA, were sufficient for adequate therapy planning. Our preliminary results reveal the potential of this new technique to become a realistic, robust, and non-invasive alternative to i.a. DSA in the diagnosis of paod.

Aged↗

Experimental investigations of image quality in X-ray mammography with conventional screen film system (SFS), digital phosphor storage plate in/without magnification technique (CR) and digital CCD-technique (CCD).

Comparison of image quality in X-ray mammography between conventional film screen film system (SFS), digital phosphor storage plate in and without magnification technique (CR) and digital CCD-technique (CCD). Radiograms of an RMI-mammography phantom were acquired using a conventional screen film system, three digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed regarding contrast and included in the comparison. The detectability of details was best with the digital mammography in CCD-technique. After confirming these promising results in clinical studies, digital mammography should be able to replace conventional screen film technique.

Breast Neoplasms↗

Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.

BACKGROUND: We investigated the applicability and image quality of contrast-enhanced coronary artery visualization by multislice spiral CT using retrospective ECG gating. METHODS AND RESULTS: Twenty-five patients in sinus rhythm (significant coronary artery stenoses ruled out by invasive angiography) were studied with a multislice spiral CT (Siemens SOMATOM Volume Zoom). In inspiration (mean breath-hold, 37 seconds), a volume data set of the heart was acquired (intravenous contrast agent; 4 x 1-mm slice thickness; 500-ms rotation; table feed, 1.5 mm/360 degrees ). Simultaneous recording of the ECG permitted retrospective reconstruction of contiguous cross sections in intervals of 1 mm at any desired interval of the cardiac cycle. The mean duration of the image reconstruction window was 185 ms. Next to 3-dimensional reconstructions of the heart and coronary arteries, multiplanar reconstructions were rendered to determine the visualized length of the coronary arteries, the contrast-to-noise ratio, and the correlation of coronary artery diameters to quantitative coronary angiography. CONCLUSIONS: The coronary arteries could be visualized over long segments (left main, 9+/-4 mm; left anterior descending, 112+/-34 mm; left circumflex, 80+/-29 mm; right coronary artery, 116+/-33 mm). On average, 78+/-16% of these distances were visualized free of motion artifacts. The mean contrast-to-noise ratio was 9.3+/-3.3. Coronary artery diameters in multislice spiral CT showed close correlation to quantitative coronary angiography (CT, 3.3+/-1.0 mm; angiography, 3. 2+/-0.9 mm; mean difference, 0.38 mm; r=0.86). Contrast-enhanced multislice spiral CT permits visualization of the coronary artery lumen. Further studies are necessary to determine whether image quality is sufficient to reliably detect coronary artery stenoses.

Adult↗

Dedicated phased-array coil for peripheral MRA.

In this paper we introduce a phased-array coil dedicated for MRA of peripheral arteries which covers the upper and lower legs. The structure of this coil includes a solid cabinet with four flexible wings forming a "T." The flexibility of the wings allows adaptation to the individual leg size. There are eight circularly polarized channels, four on each side. This coil is compatible with other surface coils. For MRA of peripheral arteries, it is combined with the body phased-array coil and the spine array coil which cover the lower abdomen and the pelvis. We examined six patients using this coil combination. The image quality, the signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of these examinations were compared with that of peripheral MRA examinations obtained with the body resonator. Image quality with the array coil was considerably improved in comparison with the body resonator examinations. The SNR and CNR increased approximately 100%. The handling of this coil was very quick and simple, similar to the procedure with other surface coils. The use of dedicated phased-array coils for peripheral MRA may be an important step toward the establishment of MR digital subtraction angiography (DSA) as a non-invasive alternative to intra-arterial DSA in the visualization of peripheral arteries. Its potential has to be evaluated in future studies.

Aged↗

Head and neck tumors: imaging recurrent tumor and post-therapeutic changes with CT and MRI.

OBJECTIVE: To evaluate criteria for detection of tumor recurrence and post-treatment changes in patients with head and neck malignancies in computed tomography (CT) and magnetic resonance imaging (MRI). METHODS AND MATERIALS: Thirty-nine patients with head and neck carcinoma receiving radiochemotherapy were examined before, during and after therapy with MRI. Changes in signal intensity were correlated to histology or clinical course. Three hundred and thirty-one patients with head and neck malignancies were examined with CT after therapy. CT diagnoses were correlated with histology or clinical course. RESULTS: Main criteria for recurrent/residual tumor in MRI was infiltrative mass with high signal intensity in T2-weighted images and enhancement after Gd-DTPA in T1-weighted images. Radiation-induced changes led to false positive diagnosis in 46% in the interval up to 3 months after therapy and in 58% in the interval 3-6 months after therapy. The combination of a circumscribed, infiltrative mass with contrast enhancement in CT had a sensitivity of 86% and a specificity of 80%. CONCLUSION: CT could accurately demonstrate postoperative changes and tumor recurrence. MRI had advantages in differentiation of tumor and scar, but edema after radiation therapy can spoil diagnosis.

Combined Modality Therapy↗

Fluoroscopically triggered contrast-enhanced 3D MR DSA and 3D time-of-flight turbo MRA of the carotid arteries: first clinical experiences in correlation with ultrasound, x-ray angiography, and endarterectomy findings.

The aim of this article was to obtain initial experiences with fluoroscopically triggered contrast-enhanced (CE) 3D MR DSA with elliptical centric k-space order and 3D time-of-flight (TOF) turbo MRA of the carotid arteries. In this prospective study we examined 16 consecutive patients with suspicion of atherosclerotic disease involving the carotid arteries. Ultrasound was available in all, x-ray angiography in 12, surgical correlation in 9, and intraoperative x-ray angiography in 4 patients. All examinations were done on a 1.5 T unit applying: transverse plain 3D TOF turbo MRA and coronal CE MRA with fluoroscopic triggering. Combining head and neck array coils allowed the visualization of supraaortic arteries from the aortic arch to the circle of Willis. MRA results (maximum intensity projections) were compared with x-ray angiography, ultrasound, and inspection of endarterectomy specimens. Volume rendering was performed in selected cases additionally. Agreement between CE MRA, 3D TOF turbo MRA and x-ray angiography regarding stenoses of the internal and external carotid artery was very good. CE MRA was able to detect correctly intracranial stenoses, but delineation of the aortic arch and proximal common carotid arteries was sometimes reduced. Volume rendering was suited for visualization of MRA images providing a realistic three-dimensional impression. In conclusion, high-resolution fluoroscopically triggered CE MRA as non-invasive technique is another important step on the way to replace invasive x-ray angiography for the evaluation of atherosclerotic carotid artery disease. High resolution 3D TOF turbo MRA might be a helpful adjunct to increase the diagnostic reliability for the carotid bifurcation.

Aged↗

[Diagnosis of glomus jugulare tumor recurrence with dynamic contrast medium flow in MRI].

PURPOSE: To evaluate the ability of dynamic MRI to differentiate residual tumor from scar after glomus jugulare (GJ) surgery. METHODS: 26 patients after GJ surgery were examined with dynamic contrast medium MRI on a 1.5 T Philips-Gyro-Scan NT. A T1-weighted TFE sequence was performed to localise the 5 slices for the dynamic study. Subsequently, a T1-weighted TFE sequence was used for the dynamic contrast medium study. We started contrast medium administration and TFE sequence at the same time. The time until acquisition of the first image was 7.4 s, and the interval between two images 7 s (total time 2.24 min). Intensity versus time studies were performed in the region of interest. RESULTS: 2 typical intensity versus time graphs were observed: residual tumors showed a rapid increase in signal intensity, followed by a "wash-out" phase, and a plateau phase in the later course. Scar showed a moderate increase in signal intensity, followed by a plateau phase on a low intensity level. In 9 patients, in whom tumor removal was subtotal, we saw the typical graph of a GJ tumor. 4 of 17 patients with complete tumor removal showed a typical graph like that of residual tumor, 13 of 17 patients showed the typical graph of a scar. CONCLUSION: With dynamic contrast medium MRI studies, differentiation between residual tumor and scar is possible in patients with prior GJ surgery.

Cicatrix↗

[Experimental studies on image quality in conventional film screen system, digital phosphor storage plate mammography in mangnification technique and digital mammography in CCD-technique].

UNLABELLED: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. MATERIALS AND METHODS: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were postprocessed emphasizing contrast and included in the comparison. RESULTS: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. CONCLUSIONS: Based on these results there is the possibility to replace the conventional film screen system by further studies--this has to be confirmed.

Breast Neoplasms↗

Modern imaging methods versus clinical assessment in the evaluation of hospital in-patients with suspected pancreatic disease.

OBJECTIVE: Various modern imaging procedures such as endoscopic retrograde cholangiopancreatography (ERCP), computed tomography (CT), and endoscopic ultrasonography (EUS) have been shown to be highly accurate in the diagnosis of specific disorders of the pancreas. However, prior information often causes bias in the interpretation of these results. Little information is available concerning the value of these examinations in the primary and differential diagnosis of suspected pancreatic disease-particularly in comparison with clinical evaluation, including laboratory tests and transabdominal ultrasound (TUS). METHODS: Clinical and imaging information (EUS, ERCP, and CT) was collected for 184 inpatients who were referred over a 5-yr period for evaluation of suspected pancreatic disease. On the basis of patient history, laboratory tests, and the results of routine TUS, one gastroenterologist, who was unaware of any of the other procedures or the final diagnosis, made a presumptive clinical diagnosis. CT and ERCP images and EUS videotapes were then analyzed by three different and independent examiners, who had the same clinical information except for the TUS results, but were completely blinded to the results of the other examinations and the patients' diagnoses. The final diagnoses were obtained by surgery, histology, and cytology, plus a follow-up of at least 1 yr (mean 35 months) in all noncancer cases. RESULTS: The final diagnoses were: normal pancreas (n = 36), chronic pancreatitis without a focal inflammatory mass (n = 53) or with a focal inflammatory mass (n = 18), and pancreatic malignancy (n = 77). Clinical evaluation, including ultrasonography, achieved a sensitivity for pancreatic disease of 94% but a specificity of only 35%. The figures for the sensitivity and specificity of the three imaging procedures were 93% and 94%, respectively, for EUS; 89% and 92% for ERCP; and 91% and 78% for CT (p < 0.05 for the specificity of clinical assessment vs all three imaging tests, p > 0.05 for comparison of the three imaging procedures). In the differential diagnosis between cancer and chronic pancreatitis as well as between malignant and inflammatory tumors, there was no difference among clinical assessment and the three imaging tests. CONCLUSIONS: In a group of patients with a high suspicion of pancreatic disease, little additional sensitivity in the diagnosis of pancreatic disease is provided by sophisticated imaging procedures such as EUS, ERCP, and CT, in comparison with clinical assessment including laboratory values and TUS. However, the specificity can be substantially improved. To confirm the diagnosis, one of the three examinations is needed, depending on the suspected disease and local expertise. The imaging procedures should be performed in a stepwise fashion for specific purposes, such as exclusion of pancreatic disease and the planning of treatment in chronic pancreatitis and pancreatic cancer.

Adolescent↗