Search PubMed⌕ Search

Biomedical subjects

W A Wells

Publications and source records attributed to W A Wells.

49 records · Page 3Linked to original sources

Accuracy of prenatal sonography for detecting circumvallate placenta.

OBJECTIVE: We determined the accuracy of prenatal sonography for detecting placental circumvallation, a placental abnormality associated with increased fetal morbidity and mortality. MATERIALS AND METHODS: We analyzed 62 healthy pregnant (range, 18-36 weeks) patients with focused placental sonography for detection of morphologic abnormality using the published criteria for circumvallate placenta (irregular edge, uplifted margin, or placental sheet or shelf). Placental marginal sonograms were taken at 30 degrees intervals around the entire placental margin. Five experienced sonologists who were unaware of the pathologic findings independently reviewed the placental images and graded the placentas from 1 (definitely normal) to 5 (definitely circumvallate). Receiver operating characteristic (ROC) curves and area under the ROC curve were calculated for each reader. Gross and microscopic pathology was used as the gold standard for all cases. RESULTS: In the 62 patients, sonography revealed 49 normal placentas (79%), 12 partially circumvallate placentas (19%), and one completely circumvallate placenta (2%). ROC curves for the reviewers resulted in values for area under the curve ranging from .39 to .58. The sonologist who achieved the highest value for the area under the curve classified the 13 cases of proven circumvallation as one case of definite circumvallation, four cases as uncertain or equivocal, and eight cases as probably or definitely normal placentas. Of the normal placentas, 35% were graded as probably or definitely circumvallate by at least one sonologist. All sonologists misgraded the case of complete circumvallation as normal. CONCLUSION: Focused placental sonograms interpreted by experienced sonologists fail to detect the placental edge abnormality in most cases of circumvallation. In our study, 17 of 49 normal placentas were diagnosed as probably or definitely circumvallate by one or more observers. Our sonologists' interpretations of sonograms showed that complete circumvallation was difficult to assess. Although our study had a limited number of patients, the accuracy of sonography of the placenta for revealing circumvallation appears to be limited.

Case-Control Studies↗

The breakthrough.

Explore the source record for details and available documents.

Ethics, Medical↗

The spindle-assembly checkpoint: aiming for a perfect mitosis, every time.

Checkpoints reduce the frequency of errors in cell division by delaying the progress of the cell cycle until certain processes are complete. The spindle-assembly checkpoint prevents the onset of anaphase until a bipolar spindle is present and all chromosomes are attached to the spindle. Evidence from yeast and mammalian cells suggests that kinetochores are at least one source of the signal that stops the cell cycle. Recent studies in budding yeast have begun to define the signal-transduction pathway involved in the spindle-assembly checkpoint, but details of the endpoint of the pathway, where these signals interact with the cell-cycle machinery, remain to be characterized.

Journal Article↗

Sonography of the placenta with emphasis on pathological correlation.

The placenta is a most interesting but unfortunately often ignored and misunderstood organ. Included in its many functions are fetal oxygenation and nutrition as well as a myriad of endocrinological contributions and protein synthesis. The sonologist is strongly encouraged to study this amazing structure with ultrasound because significant pathology afflicts the placenta, often before affecting the fetus. Placental abnormalities, therefore, can be an "early warning system" for fetal problems. Recognition of clinically important lesions (abruption, accreta) as well as important anatomical variants (intervillous thrombosis, septal cyst) is crucial for the physician who performs and interprets prenatal ultrasound. This article discusses the common abnormalities of the placenta and highlights some correlative pathological processes, which will serve to enhance the reader's understanding of sonographic findings. A practical approach is presented with respect to assessment of the hypoechoic lesion, placental infarction, thick placenta, placenta previa, abruption, placenta accreta, and placental tumors.

Female↗

Aberrantly segregating centromeres activate the spindle assembly checkpoint in budding yeast.

The spindle assembly checkpoint is the mechanism or set of mechanisms that prevents cells with defects in chromosome alignment or spindle assembly from passing through mitosis. We have investigated the effects of mini-chromosomes on this checkpoint in budding yeast by performing pedigree analysis. This method allowed us to observe the frequency and duration of cell cycle delays in individual cells. Short, centromeric linear mini-chromosomes, which have a low fidelity of segregation, cause frequent delays in mitosis. Their circular counterparts and longer linear mini-chromosomes, which segregate more efficiently, show a much lower frequency of mitotic delays, but these delays occur much more frequently in divisions where the mini-chromosome segregates to only one of the two daughter cells. Using a conditional centromere to increase the copy number of a circular mini-chromosome greatly increases the frequency of delayed divisions. In all cases the division delays are completely abolished by the mad mutants that inactivate the spindle assembly checkpoint, demonstrating that the Mad gene products are required to detect the subtle defects in chromosome behavior that have been observed to arrest higher eukaryotic cells in mitosis.

Cell Cycle↗

The New Hampshire Mammography Network: the development and design of a population-based registry.

OBJECTIVE: Some authors have proposed a national mammography registry to improve and monitor breast diagnostic practices. However, issues such as confidentiality, accuracy, and direct and indirect costs are practical barriers to implementing such a registry. This paper describes the development and design of a population-based mammography registry in New Hampshire. The project's objectives are to assess the accuracy of mammography by comparing interpretive results with pathology and tumor-registry reports and to improve mammographic performance by reporting findings to facilities, radiologists, and pathologists statewide. MATERIALS AND METHODS: We recruited radiologists and pathologists through professional associations and facilities through site visits. Data used to develop and design the registry were collected during site visits, using structured face-to-face interview methods. Only one site refused to provide site-specific information. RESULTS: Facilities in New Hampshire estimated the annual mammographic volume to be approximately 148,000. We have noted a great deal of variability in mammography practices. Their principal methods for determining screening versus diagnostic mammograms were by patient self-reports (44% of practices), referring physicians' reports (38%), and radiologists' reports (18%). Although 71% of practices have computers, only 16% have radiology information systems or hospital information systems that offer computerized patient-tracking capabilities. More than 90% of New Hampshire radiologists exclusively use freehand dictation for reporting, and although almost 50% codify reports, only 11% use the American College of Radiology lexicon. These data and concerns expressed by radiologists, pathologists, technologists, and administrators helped shape the New Hampshire registry. CONCLUSION: Heterogeneity of radiologic practices poses major challenges for implementing a population-based mammography registry. Issues such as confidentiality, the difficulty of assessing diagnostic acumen, and the time involved in providing data to a registry must be adequately addressed. For the registry to succeed in such diverse settings, researchers, radiologists, pathologists, technologists, and administrative staff must collaborate and cooperate.

Adult↗

Ultrasound placental cysts associated with massive placental stem villous hydrops, diploid DNA content, and exomphalos.

A pregnancy associated with antenatally detected placental cysts and an anterior abdominal wall defect is described. The anterior abdominal wall defect proved to be an exomphalos in which a short segment of normal cord intervened between the herniated sac and the cord insertion. The placental cysts detected antenatally by ultrasound were shown subsequently to be massive main stem villous hydrops with cisternal formation but no evidence of trophoblastic hyperplasia. Antenatal placental biopsy and amniocentesis revealed a normal male karyotype. Confined placental mosaicism for triploidy was excluded by DNA flow cytometry. This case was not associated with Beckwith-Wiedemann syndrome.

Adult↗