Search PubMed⌕ Search

Biomedical subjects

W A Wells

Publications and source records attributed to W A Wells.

At least 19 recordsLinked to original sources

Let's make Golgi.

Does the Golgi self-organize or does it form around an instructive template? Evidence on both sides is piling up, but a definitive conclusion is proving elusive.

ADP-Ribosylation Factors↗

Searching for a spindle matrix.

New evidence supports the idea of a nonmicrotubule spindle matrix, but the debate about the reality of this structure continues.

Animals↗

Quantitative hemoglobin tomography with diffuse near-infrared spectroscopy: pilot results in the breast.

The authors describe what is, to the best of their knowledge, the first quantitative hemoglobin concentration images of the female breast that were formed with model-based reconstruction of near-infrared intensity-modulated tomographic data. The results in 11 patients, including two with breast tumors with pathologic correlation, are summarized. Hemoglobin concentration appears to correlate with tumor vascularity without the need for exogenous contrast material and thereby has intrinsic diagnostic value.

Adult↗

Pathologists' agreement with experts and reproducibility of breast ductal carcinoma-in-situ classification schemes.

Several histologic classifications for breast ductal carcinoma in situ (DCIS) have been proposed. This study assessed the diagnostic agreement and reproducibility of three DCIS classifications (Holland [HL], modified Lagios [LA], and Van Nuys [VN]) by comparing the interpretations of pathologists without expertise in breast pathology with those of three breast pathology experts, each a proponent of one classification. Seven nonexpert pathologists in New Hampshire and three experts evaluated 40 slides of DCIS according to the three classifications. Twenty slides were reinterpreted by each nonexpert pathologist. Diagnostic accuracy (nonexperts compared with experts) and reproducibility were evaluated using inter- and intrarater techniques (kappa statistic). Final DCIS grade and nuclear grade were reported most accurately among nonexpert pathologists using HL (kappa = 0.53 and 0.49, respectively) compared with LA and VN (kappa = 0.29 and 0.35, respectively, for both classifications). An intermediate DCIS grade was assessed most accurately using HL and LA, and a high grade (group 3) was assessed most accurately using VN. Diagnostic reproducibility was highest using HL (kappa = 0.49). The VN interpretation of necrosis (present or absent) was reported more accurately than the LA criteria (extensive, focal, or absent; kappa = 0.59 and 0.45, respectively), but reproducibility of each was comparable (kappa = 0.48 and 0.46, respectively). Intrarater agreement was high overall. Comparing all three classifications, final DCIS grade was reported best using HL. Nuclear grade (cytodifferentiation) using HL and the presence or absence of necrosis were the criteria diagnosed most accurately and reproducibly. Establishing one internationally approved set of interpretive definitions, with acceptable accuracy and reproducibility among both pathologists with and without expertise in breast pathology interpretation, will assist researchers in evaluating treatment effectiveness and characterizing the natural history of DCIS breast lesions.

Breast Neoplasms↗

Mammography in 53,803 women from the New Hampshire mammography network.

PURPOSE: To describe measures of mammography performance in a geographically defined population and evaluate the interpreter's use of the Breast Imaging Reporting and Data System (BI-RADS). MATERIALS AND METHODS: Mammographic data from 47,651 screening and 6,152 diagnostic examinations from November 1, 1996, to October 31, 1997, were linked to 1,572 pathologic results. Mammographic outcomes were based on BI-RADS assessments and recommendations reported by the interpreting radiologist. The consistency of BI-RADS recommendations was evaluated. RESULTS: Screening mammography had a sensitivity of 72.4% (95% CI: 66.4%, 78.4%), specificity of 97.3% (95% CI: 97.25%, 97.4%), and positive predictive value of 10.6% (95% CI: 9.1%, 12.2%). Diagnostic mammography had higher sensitivity, 78.1% (95% CI: 71.9%, 84.3%); lower specificity, 89.3% (95% CI: 88.5%, 90.1%); and better positive predictive value, 17.1% (95% CI: 14.5%, 19.8%). The cancer detection rate with screening mammography was 3.3 per 1,000 women, with a biopsy yield of 22.4%, whereas the interval cancer rate was 1. 2 per 1,000. Nearly 80% of screening-detected invasive malignancies were node negative. The recall rate for screening mammography was 8. 3%. Ultrasonography was used in 3.5% of screening and 17.5% of diagnostic examinations. BI-RADS recommendations were generally consistent, except for probably benign assessments. CONCLUSION: The sensitivity of screening mammography in this population-based sample is lower than expected, although other performance indicators are commendable. BI-RADS "probably benign" assessments are commonly misused.

Adult↗

Perfusion weighted imaging during migraine: spontaneous visual aura and headache.

Using perfusion weighted imaging, we studied 28 spontaneous migraine episodes; 7 during visual aura (n = 6), 7 during the headache phase following visual aura (n = 3), and 14 cases of migraine without aura (n = 13). The data were analyzed using a region-of-interest-based approach. During aura, relative cerebral blood flow (rCBF) was significantly decreased (27% +/- 0.07) in occipital cortex contralateral to the affected hemifield. rCBV was decreased (15% +/- 0.12) and mean transit time increased (32% +/- 0.3), persisting up to 2.5 h into the headache phase. Other brain regions did not show significant perfusion changes. During migraine without aura, no significant hemodynamic changes were observed. In one patient who experienced both migraine with and without aura, perfusion deficits were observed only during migraine with aura. These findings suggest that decremental blood flow changes in occipital lobe are most characteristic of migraine with aura.

Adult↗

Focal aneurysmal dilatation of subchorionic vessels simulating chorioangioma.

Subchorionic vascular aneurysms of the placenta are rare lesions and may present confusion with chorioangioma or focal mesenchymal dysplasia on sonography. To our knowledge, the findings of placental aneurysms have not been reported in the ultrasound literature. We present a case with detailed sonographic evaluation, including spectral and color Doppler and pathological analysis, that was mistaken for chorioangioma prenatally. Knowledge of this benign entity may allow the sonologist to recommend conservative management in similar cases.

Adult↗