[Clinical results of dual-energy radiography in thoracic studies].

Dual energy methods permit the reconstruction of either soft tissue or calcium density structures. The value of the technique is demonstrated in 220 patients. Demonstration of the thoracic organs without superimposition of the skeleton improves the recognition of pulmonary lesions. Opacities related to ribs no longer simulate pulmonary lesions. The mediastinal borders are demonstrated more clearly by double spectrum radiography than by any other radiographic method. Soft tissue calcification can be shown with a high degree of sensitivity. Skeletal changes which may be obscured by overlapping soft tissue shadows on conventional radiography can also be diagnosed by this technique.

Humans↗

Vertebral bone mineral analysis: an integrated approach with CT.

In the assessment of vertebral bone mineral density (BMD) with quantitative computed tomography, accuracy is limited by systematic errors caused by beam-hardening effects and unknown marrow and fat concentrations in trabecular bone. Reproducibility depends on precise repositioning of the patient, selection of the region of interest (ROI), and apparatus stability. In an integrated approach, these error sources were taken into account. Dual-energy methods are incorporated and tested to avoid systematic errors. Contour-detection algorithms for automated ROI determination that work reliably and offer improved reproducibility and efficiency are presented. A new design of reference phantom with solid tissue-equivalent materials provides calibration in BMD units and checks apparatus stability. Dual-energy methods are necessary to achieve accuracy of 5% or better. Automated ROI definition and reference phantom methods are mandatory for reproducibility of 2% or better.

Algorithms↗

Reduction of CT artifacts caused by metallic implants.

A technique to reduce metallic implant artifacts on computed tomography scans is presented. The implant boundaries are determined semiautomatically; the missing projection data are replaced by linear interpolation. The complete procedure requires 1-2 minutes per scan. Images with greatly improved quality were obtained in the presence of surgical clips and pelvic implants; success is limited in highly structured regions, such as the facial skull.

Algorithms↗

[Material selective imaging and determination of density using the dual energy method. II. Clinical use of dual energy radiography].

The use of dual energy methods in digital radiography allows selective imaging of soft tissues or calcified structures and contrast media. The value of this method is demonstrated on the basis of 400 patient examinations. The isolated imaging of soft tissues without skeletal superposition gives particular advantages in diagnosis of the chest and the cranio-cervical region. Soft tissue calcifications and calcium-containing concrements in the bile ducts and in the urinary tract are well demonstrated without soft tissue superposition. The disadvantages and the limits of the method are discussed, its potential and possible future developments are shown.

Bone Diseases↗

Studies of paranasal sinus ventilation by xenon-enhanced dynamic CT.

A new method to determine ventilation of the paranasal sinuses is presented. After insufflation of pure stable xenon into the sinus system via the nasal cavity the gas wash-out is detected by means of quantitative dynamic computerized tomography. The measured time density curves allow to derive gas exchange parameters for all paranasal sinuses. We report mean gas exchange times for the maxillary, sphenoidal and frontal sinuses as well as the posterior ethmoidal cells obtained from 17 patient studies. Some clinical examples are discussed in detail. Compared to existing procedures, xenon-enhanced dynamic CT is the only non-invasive quantitative method to determine ventilation of all paranasal sinuses.

Humans↗

[Digital radiography using a computed tomography instrument in comparison with conventional film-screen images].

Parameters of image quality, comprising spatial resolution and contrast, have been determined in the form of a contrast/detail diagram for a digital system (Topogram) and a film-screen system. The digital system was particularly examined concerning its contrast sensitivity in relation to quantum noise. The clinical implications of the comparison of the systems, where evaluated on chest x-rays of 250 patients. Despite lower image sharpness, the digital method is already able to produce equivalent or better diagnostic results in certain circumstances. The advantages and disadvantages of both systems are discussed in detail.

Breast Neoplasms↗

Bolus geometry and dynamics after intravenous contrast medium injection.

Studies of contrast medium bolus geometry and dynamics were carried out to provide data for optimizing the use of contrast medium in digital subtraction angiography (DSA) and dynamic CT. Apparatus for fast digital recording of x-ray attenuation profiles was used; this is a new digital imaging mode (Chronogram) available on a CT scanner. Variables studied were injection site, injection speed, contrast medium volume, and subsequent saline injection; peak time, full width at half maximum, and maximum contrast enhancement were recorded. Positioning of the catheter in the vena cava reduced peak time and increased enhancement. High injection speeds led to shorter peak times. An increase in speed from 4 to 8 ml/s caused markedly higher enhancement, while further increase did not add significantly to enhancement. For a given injection speed, enhancement was increased and the peak time delayed by using larger injection volumes. Injection of saline solution after intravenous contrast medium did not change results significantly. There was a statistically significant correlation between pulse rate and peak time; the faster the pulse rate the shorter the peak time.

Angiography↗

Digital scanned projection radiography: optimization of image characteristics.

Fast interactive programs for the investigation of the effects of different processing methods were developed in an attempt to optimize the diagnostic value of digital scanned projection radiography (SPR) data. Filters from two classes of functions with varied frequency characteristics were evaluated. Arbitrary combinations of filtered and unfiltered images were generated. Speed was achieved by implementing the filtering as a convolution operation with standard computed tomography hardware (20 sec/image). The criteria for the choice of the reconstruction parameters are discussed. The clinical results show that suppressing the low-frequency content of the image, as in smoothing, low-pass filtering, and subtracting the background from the original image, optimizes the diagnostic value of SPR images.

Filtration↗

Calculation of x-ray grid characteristics by Monte Carlo methods.

The performance of x-ray grids has generally been evaluated experimentally. A theoretical method has been developed by which photon histories are generated by Monte Carlo methods. The probability of penetrating the grid is calculated for each photon escaping from the object towards the detector. The scatter transmission of the grid is determined as the average of these individual probabilities. Results for linear and cross grids are in good agreement with measurements. The method is applicable to arbitrary irradiation and grid parameters. The dependence of scatter transmission values on the irradiation parameters is shown. Grids with linear and zigzag strip patterns are compared in order to demonstrate that even grids that cannot at present be manufactured can nevertheless be evaluated.

Monte Carlo Method↗

Fast digital recording of X-ray dilution curves: a preliminary evaluation.

A digital radiography apparatus that is implemented on a computed tomography (CT) scanner allows for the fast recording of dilution curves of thin sections of a CT scan. Densities are plotted vs. time, and structures can be allocated by reference to the corresponding CT image. Intravenous bolus passage in the larger vessels, and enhancement in the organs was determined in patients. Modulations that resulted from breathing posed problems, but those that resulted from pulsation may yield useful additional information. Possible clinical applications are discussed.

Angiography↗

Rapid protyping technology in medicine--basics and applications.

Using medical models built with Rapid Prototyping (RP) technologies represents a new approach for surgical planning and simulation. These techniques allow one to reproduce anatomical objects as 3D physical models, which give the surgeon a realistic impression of complex structures before a surgical intervention. The shift from the visual to the visual-tactile representation of anatomical objects introduces a new kind of interaction called 'touch to comprehend'. As can be seen, from the presented case studies of maxillo-cranio-facial surgery, the RP models are very well suited for use in the diagnosis and the precise preoperative simulation of skeleton modifying interventions.

Acrocephalosyndactylia↗

Perspective volume rendered motion: gaining insights virtually.

Since modern imaging modalities deliver huge amounts of data the visualization techniques utilized must emphasize the structures of interest. To compare them, the different visualization techniques are regressed to a common ground whereby their strengths and weaknesses can be revealed. Perspective, lighting, color and motion support the real world look and feel. Virtual 3D techniques allow the observer to move through 3D images of anatomy almost in real time. In virtual cisternoscopy this concept is applied to 3D data of the head to reveal a closer look at the cerebral vessels. The more realistic presentation of the 3D data allows for higher efficiency.

Brain↗

Measurement of paranasal sinus ventilation by xenon-enhanced dynamic computed tomography.

Ventilation of the paranasal sinuses plays an important role in the etiology of acute and chronic sinusitis. We present a new method to determine sinus ventilation. Two to three liters of pure stable xenon are insufflated into the sinus system, and the xenon washout is measured subsequently by dynamic CT. Gas exchange parameters for the different sinuses are obtained from the washout curves by an exponential fit. We report our preliminary clinical results. The method proved to be reliable and easy to apply. Compared with existing procedures it is the only noninvasive quantitative method for the determination of the ventilation of all paranasal sinuses.

Humans↗

Semiautomatic evaluation procedures for quantitative CT of the lung.

Accuracy, reproducibility, and objectivity are important in quantitative assessment of lung density and structure by CT, and the measurement has to be carried out under tightly controlled conditions. We therefore employ respiratory gating at defined levels of inspiration for CT scanning. In the evaluation process, we found operator-induced errors of 2-6 HU standard deviation for the relatively simple task of global lung density estimates; in regional evaluations, they frequently exceeded 10 HU. We therefore developed semi-automated evaluation algorithms that isolate lung parenchyma by fast contour tracking and define subregions by shrinking, radial segmenting, and anteroposterior subdividing of the left and the right lung. Global and regional mean density values and histogram parameters were extracted. Based on our clinical studies, we estimate that an overall precision of better than 5% can be achieved in quantitative CT of the lung with cooperative patients.

Algorithms↗

Standardized quantitative high resolution CT in lung diseases.

Twenty-seven patients with diffuse fibrosing alveolitis (DFA), 27 patients with granulomatous lung disease (GLD), 3 patients with homozygous alpha 1-proteinase inhibitor deficiency (alpha 1-PID), and 6 healthy volunteers (C) were studied using thin section high resolution CT (HRCT) at 50% of actual vital capacity (VC), determined and controlled spirometrically during each exposure. A fast contour tracing algorithm was used to isolate the lung parenchyma followed by a quantitative histogram analysis of the frequencies of CT values. Mean CT values enabled us to discriminate significantly between the groups of C and alpha 1-PID. Significant differences were found between the groups of GLD and DFA versus C by applying suitably selected intervals of CT values. Moreover, if the patients were assigned to four different groups according to their lung function results (normal, restrictive, obstructive, restrictive and obstructive), again significant differences existed with respect to defined intervals of CT values. Mean CT values showed a significant negative correlation with lung function tests representative of lung parenchymal disease, i.e., VC, diffusing capacity, and exercise PaO2. Moreover, CT values ranging from -899 to -800 HU correlated positively, whereas CT value frequencies above -699 HU correlated inversely with these same lung function parameters. These results indicated that certain intervals of CT values do reflect functionally different abnormalities of lung parenchyma. It is concluded that an analysis of frequencies of CT values determined by spirometrically standardized HRCT provides objective quantitative data that reflect changes of pulmonary structure corresponding to lung function impairments. Thus, spirometrically standardized HRCT may be helpful for evaluating and staging patients with diffuse pulmonary disease.

Adult↗

Brain perfusion studies by xenon-enhanced CT using washin/washout study protocols.

Very short inhalation times and short total examination times are desirable in cerebral blood flow measurements by xenon enhanced CT to minimize the possibility of flow activation and--more importantly for practical purposes--the probability of patient motion due to the effects of xenon. We have investigated washin/washout procedures and have compared them with conventional washin scanning protocols by simulation and in clinical studies. Examination protocols with only 3 min of inhalation and up to eight scans, all taken at 1 min intervals, provide flow estimates with smaller SDs than would be obtained for washin studies taken with the same total radiation dose. Compared with a standard 8 min washin procedure, a 3 min washin/5 min washout study using the same dose yields an SD reduction by a factor of 1.3 for low flow areas and of 1.8 for high flow gray matter. A 3 min washin/3 min washout study, employing only 78% of the dose of an 8 min washin study, will still provide an SD reduction factor of 1.7 in gray matter. These results have been confirmed qualitatively by studies carried out both in volunteers and in patients.

Cerebrovascular Circulation↗

A comparison of conventional and spiral CT: an experimental study on the detection of spherical lesions.

OBJECTIVE: It is accepted that spiral CT scanning may offer significant advantages in a number of clinical applications. There is still some concern with respect to image quality, however, since slice sensitivity profiles are slightly broadened due to the table motion. We carried out theoretical analysis, phantom measurements, and computer simulations to evaluate and to compare contrast and spatial resolution for conventional and for spiral scanning. Special emphasis was put on the task of detecting spherical lesions. MATERIALS AND METHODS: For standard test objects that measure only resolution in the scan plane, no significant difference between conventional and spiral scanning was observed. We therefore designed a phantom setup that allowed us to place spheres of arbitrary diameter and contrast in arbitrary positions to test three-dimensional (3D) resolution. RESULTS: For conventional CT, both lesion contrast and the degree of spatial separation of lesions observed depend on the relation of the start position of the scan series to the random location of a sphere or lesion. Spiral CT offers space-invariant resolution due to its continuous scanning. Small lesion contrast may be improved by up to a factor of 1.8 when compared with conventional CT since slices can be centered retrospectively. Measurements and simulations were in excellent agreement. CONCLUSION: We conclude that spiral CT can offer improved 3D contrast and spatial resolution. To exploit these advantages, images should be reconstructed in spiral CT at increments of less than half the distance traveled during one 360 degrees tube rotation. With four to five images per such interval, usually equal to the slice width, results very close to the theoretical optimum are achieved. Many of the presented considerations and results apply to other slice imaging modalities like MRI in analogous fashion.

Computer Simulation↗