Search PubMed⌕ Search

Biomedical subjects

W A Kalender

Publications and source records attributed to W A Kalender.

At least 19 recordsLinked to original sources

Exercise maintains bone density at spine and hip EFOPS: a 3-year longitudinal study in early postmenopausal women.

It is an important aim in the prevention of osteoporosis to stop or decelerate bone loss during the early postmenopausal years. Here we report on results of the 3-year EFOPS exercise trial in osteopenic women. The exercise strategy emphasized low-volume high-resistance strength training and high-impact aerobics. Forty-eight fully compliant women (55.1+/-3.3 years) with no medication or illness affecting bone metabolism participated in the exercise group (EG); 30 women (55.5+/-3.0 years) served as non-training controls (CG). At baseline there were no significant between-group differences with respect to physical fitness, bone mineral density, pain and nutritional status. The training consisted of two group training and two home training sessions per week. The study participants of both groups were individually supplemented with calcium and vitamin D (cholecalciferol). Bone mineral density (BMD) was measured by DXA at the lumbar spine, proximal femur and distal forearm and by QCT at the lumbar spine. Speed of sound and broadband ultrasound attenuation were determined at the calcaneus by quantitative ultrasound (QUS). Pain frequency and intensity at different skeletal sites were assessed via questionnaire. After 38 months, the following within-group changes were measured: DXA lumbar spine, EG: 0.8% n.s.; CG: -3.3% P<0.001; QCT trabecular ROI, EG: 1.1% n.s; CG: -7.7% P<0.001; QCT cortical ROI, EG: 5.3% P<0.001; CG: -2.6% P<0.001; DXA total hip: EG: -0.2% n.s; CG -1.9%, P<0.001; DXA distal forearm, EG: -2.8% P<0.001; CG: -3.8% P<0.001; BUA, EG: -0.3% n.s; CG -5.4% P<0.001; SOS, EG: 0.3% n.s; CG -1.0% P<0.001. At year 3 between-group differences relative to the exercise group were: DXA lumbar spine: 4.1% P<0.001; QCT trabecular ROI: 8.8% P<0.001; QCT cortical ROI: 7.9% P<0.001; DXA total hip: 2.1%, P<0.001; DXA distal forearm: 1.0% n.s.; BUA: 5.8% P<0.05; SOS: 1.3% P<0.001. Pain frequency and intensity in the spine significantly decreased in the exercise group and increased in the control group, while no between-group differences were detected in the main joints. In summary, over a period of 3 years our low-volume/high-intensity exercise program was successful to maintain bone mineral density at the spine, hip and calcaneus, but not at the forearm.

Aging↗

Power training is more effective than strength training for maintaining bone mineral density in postmenopausal women.

Physical exercise has a favorable impact on bones, but optimum training strategies are still under discussion. In this study, we compared the effect of slow and fast resistance exercises on various osteodensitometric parameters. Fifty-three postmenopausal women were randomly assigned to a strength training (ST) or a power training group (PT). Both groups carried out a progressive resistance training, a gymnastics session, and a home training over a period of 12 mo. During the resistance training, the ST group used slow and the PT group fast movements; otherwise there were no training differences. All subjects were supplemented with Ca and vitamin D. At baseline and after 12 mo, bone mineral density (BMD) was measured at the lumbar spine, proximal femur, and distal forearm by dual-energy X-ray absorptiometry. We also measured anthropometric data and maximum static strength. Frequency and grade of pain were assessed by questionnaire. After 12 mo, significant between-group differences were observed for BMD at the lumbar spine (P < 0.05) and the total hip (P < 0.05). Whereas the PT group maintained BMD at the spine (+0.7 +/- 2.1%, not significant) and the total hip (0.0 +/- 1.7%, not significant), the ST group lost significantly at both sites (spine: -0.9 +/- 1.9%; P < 0.05; total hip: -1.2 +/- 1.5%; P < 0.01). No significant between-group differences were observed for anthropometric data, maximum strength, BMD of the forearm, or frequency and grade of pain. These findings suggest that power training is more effective than strength training in reducing bone loss in postmenopausal women.

Aged↗

Reconstruction from truncated projections in CT using adaptive detruncation.

If the object exceeds the field of measurement (FOM) of a given CT scanner, severe artifacts may result. In this work, we propose an adaptive detruncation (ADT) method to reconstruct images from medical CT projections which are truncated in the transaxial direction. The truncated projections are extrapolated by estimating the convex hull of the patient. The ADT method allows us not only to achieve artifact-free images in the FOM but also to extend the images beyond the FOM, and can therefore be very attractive, for example, in PET/CT scanners for attenuation correction.

Algorithms↗

Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation.

The potential of online tube current modulation in subsecond multislice spiral CT (MSCT) examinations of children to reduce the dose without a loss in image quality is investigated in a controlled patient study. The dose can be reduced for oval patient sectional view without an increase in noise if the tube current is reduced where the patient diameter and, consequently, attenuation are small. We investigated a product version of an online control for tube current in a SOMATOM Sensation 4 (Siemens, Forchheim). We evaluated image quality, noise and dose reduction for examinations with online tube current modulation in 30 MSCT of thorax/abdomen and abdomen and compared mA s for tube current modulation to the mA s in standard weight-adapted children protocols. Image quality was rated as "very good," "good," "diagnostic" and "poor" in a consensus by three radiologists. Noise was assessed in comparison to 24 MSCT examinations without tube current modulation measured as SD in ROIs. The dose was reduced from 26 to 43% (mean 36%), depending on the patient's geometry and weight. In general, no loss of image quality was observed. Measured noise showed a decrease up to 26% and an increase up to 36%, although there was no decrease of image quality. Online tube current modulation is now used as a standard in MSCT at our institution. Dose in MSCT examinations of children can be reduced substantially in routine examinations by online tube current modulation without a loss of image quality.

Child↗

[Automatic exposure control to reduce the dose in subsecond multislice spiral CT: phantom measurements and clinical results].

PURPOSE: To investigate the potential of dose reduction in multislice spiral CT (MSCT) with automatic exposure control. MATERIALS AND METHODS: The study was performed on a Sensation 4 multislice scanner. This prototype implementation analyzed the distribution of the attenuation along the z-axis in the lateral and sagittal directions of the digital radiogram. Depending on this distribution of the attenuation, the tube current (mA) is defined for every tube rotation. In addition, the tube current was modulated during each tube rotation. First, a three step oval water phantom was measured to evaluate the potential of this method with respect to dose reduction and image quality. In a patient study (n = 26), four different scan regions (shoulder, thorax, abdomen, pelvis) were examined and dose (mAs) and image quality evaluated in comparison to examinations with a standard protocol for these regions in adults and a weight-adjusted standard protocol in children. The image quality was classified in consensus as good, sufficient and poor image quality. RESULTS: By adapting and modulating the tube current, we substantially reduced the variation of noise in one spiral scan and in one scan region of our patient collective. The dose (average mAs) was reduced by 31 % to 66 % in children (mean 44 %) and between 35 % and 64 % in adults (mean 53 %), depending on the scan region. The image quality was substantially improved in regions with high attenuation and did not suffer in low attenuation regions. CONCLUSION: The dose can be reduced substantially by an automatic exposure control including angular tube current modulation with the same or improved image quality.

Abdomen↗

The effect of habitual physical activity, non-athletic exercise, muscle strength, and VO2max on bone mineral density is rather low in early postmenopausal osteopenic women.

CONTEXT: Although the positive effect of well-designed exercise regimes on bone mineral density (BMD) is established the osteo-anabolic relevance of habitual physical activity and non-athletic exercise is still under discussion. OBJECTIVE: To determine the effects of habitual physical activity, non-athletic exercise muscle strength, VO2max and anthropometric parameters on BMD in early post-menopausal women. DESIGN: Cross-sectional study. METHODS: 150 early postmenopausal women (55.5+/-3.4 years), which were free of diseases or medication affecting bone metabolism and had no athletic history were investigated. The influence of weight, body composition, physical activity, isometric strength, VO2max, and nutritional intake on BMD was measured at multiple sites using different techniques. Further bone markers (Osteocalcin, CTX) were determined. Activity and weight-bearing activity were assessed by questionnaire. Maximum strength was measured isometrically. Aerobic capacity was measured with an spirometric system in a stepwise treadmill test and dietary intake was monitored over 5 days. RESULTS: Slight relationships between physical activity, exercise, muscle strength and VO2max with bone parameters were determined by univariate analysis. After adjusting for confounding variables in a stepwise regression analysis, significant relationships with BMD measured at the hip or the spine could no longer be detected for physical activity, exercise, and physical fitness (strength indices, VO2max). The same was true for osteocalcin and CTX. Arm strength explained 4.5% of the variation of forearm BMD (DXA). At the calcaneal site, osteogenic exercise was significantly related to the quantitative ultrasound index (r2 = 0.27). CONCLUSION: The isolated effect of habitual physical activity, unspecific exercise participation, and muscle strength on bone parameters is rather low in (early-) postmenopausal women. CLINICAL RELEVANCE: Women at risk should take specific exercise programs into consideration rather than to increasing the amount of habitual physical activity.

Biomarkers↗

[The use of flat-panel detectors for CT imaging].

Clinical CT has reached a very high performance level by now. The introduction of spiral scanning and of multirow detectors have allowed to image even large body sections in very short time and with isotropic, high spatial resolution of better than 1 mm. For further improvements with respect to detector technology the use of flat-panel detectors (FPD), which have been developed for radiographic applications, is currently under investigation. In this article we discuss the general demands on CT detectors and specifically the suitability of FPDs with respect to CT imaging. FPDs offer excellent performance for the imaging of high-contrast structures with high spatial resolution.Low-contrast resolution and dose efficiency, however, do not yet reach the level of performance of dedicated CT detectors; temporal resolution is also limited. FPDs appear primarily suited for special applications in CT as for example 3D angiography or intraoperative imaging which also allows for improvements in workflow. For standard diagnostic CT they are not to be recommended at present, last but not least for dose reasons. The respective technical developments will have to be reassessed constantly in the future. The development of detector systems which are equally suited for radiography and CT constitutes an attractive goal.

Angiography↗

[Improvement of the image quality of MSCT of the pelvis with a raw data-based, multidimensional filter].

PURPOSE: To evaluate the potential of raw data-based multidimensional adaptive filtering (MAF) by determining its effects on image noise and image quality in multi-slice spiral CT (MSCT) of the pelvis. MATERIALS AND METHODS: Fifty patients with rectal and bladder cancer were examined with MSCT using a high-resolution protocol. Reconstructions were performed with dedicated reconstruction software and a standard algorithm, both without and with MAF, with four different modification fractions selected from 5 % to 20 %. The noise was measured at six anatomic sites of the pelvis. Image quality and image noise were rated on a 5-point-scale. RESULTS: Modification fractions of 15 % (15 % MAF) and 20 % (20 % MAF) significantly reduced the noise level at all measurement points in comparison with lower modification fractions (p < 0.05). Overall quality of the reconstructed images was rated better with 15 % MAF and 20 % MAF than with other modification fractions (p < 0.05). No further improvement of the image quality was observed by changing from 15 % MAF to 20 % MAF (p > 0.05). 15 % MAF achieved a mean noise reduction of 33 %. All examinations showed an improved visualization of the rectal wall and perirectal lymph nodes. CONCLUSIONS: MAF improves the image quality by reducing the noise level and by removing noise structures. This technique offers new perspectives to radiation dose reduction in CT.

Humans↗

Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography.

BACKGROUND: Multislice spiral computed tomography (MSCT) with retrospectively ECG-gated image reconstruction permits coronary artery visualization. We investigated the method's ability to identify high-grade coronary artery stenoses and occlusions. METHODS AND RESULTS: A total of 64 consecutive patients were studied by MSCT (4x1 mm cross-sections, 500-ms rotation, table feed 1.5 mm/rotation, intravenous contrast agent, retrospectively ECG-gated image reconstruction). All coronary arteries and side branches with a luminal diameter >/=2.0 mm were assessed concerning evaluability and the presence of high-grade stenoses (>70% diameter stenosis) or occlusions. Results were compared with quantitative coronary angiography. Of 256 coronary arteries (left main, left anterior descending, left circumflex and right coronary artery, including their respective side branches), 174 could be evaluated (68%). In 19 patients (30%), all arteries were evaluable. Artifacts caused by coronary motion were the most frequent reason for unevaluable arteries. Overall, 32 of 58 high-grade stenoses and occlusions were detected by MSCT (58%). In evaluable arteries, 32 of 35 lesions were detected, and the absence of stenosis was correctly identified in 117 of 139 arteries (sensitivity, 91%; specificity, 84%). If analysis was extended to all stenoses with >50% diameter reduction, sensitivity was 85% (40 of 47) and specificity was 76% (96 of 127). CONCLUSIONS: MSCT with retrospective ECG gating permits the detection of coronary artery stenoses with high accuracy if image quality is sufficient, but its clinical use may presently be limited due to degraded image quality in a substantial number of cases, mainly due to rapid coronary motion.

Aged↗

Stereolithographic models simulating trabecular bone and their characterization by thin-slice- and micro-CT.

The analysis of bone structure in vivo is an important goal in osteoporosis, because the determination of bone mineral density alone is insufficient to predict whether an individual patient will eventually suffer an osteoporotic fracture or not. An additional structural analysis may significantly improve the statistical assessment of fracture risk. In this study we present a method to generate realistic although enlarged 3D phantoms of trabecular bone. These phantoms are useful in characterizing the potential of in vivo imaging procedures for the analysis of bone structure and to verify textural or structural analysis methods applied to these images. Our phantoms are based on a real trabecular bone specimen that was converted to a plastic model using the technique of stereolithography. The trabecular network is modeled by hydroxyapatite. Limitations of the stereolithographic process prevent the generation of exact 1:1 replicas of the real bone. A histomorphometric analysis of microCT scans of the phantoms showed that an excellent replication of the bone structure could be achieved in phantoms enlarged by a factor of 2.5 with "trabecular" hydroxyapatite concentrations up to 400 mg/cm3. In order to demonstrate the usefulness of our phantoms, we investigated one of them with various thin-slice CT protocols using clinical single- and multi-slice spiral CT scanners. The enlargement of the phantoms limits their use on high spatial resolution CT scanners (resolution >20 lp/cm). The limited hydroxyapatite concentration requires enhanced exposure rates for the phantoms scans to offset the larger impact of noise due to the lower contrast in the phantoms.

Bone and Bones↗

A high-resolution phantom for MRI.

Assessment of spatial resolution is an important step to test the performance of new sequence techniques-especially ultrafast techniques with dedicated k-space trajectories or interpolation algorithms. Measurement of the modulation transfer function (MTF) is a rather difficult procedure, but using suitable resolution phantoms allows a simple visual evaluation of spatial resolution. In contrast to commonly used test objects with a very restricted number of resolution patterns we developed a phantom containing resolution patterns from 0.1 to 1.5 mm in steps of 0.1 mm. One resolution pattern consists of five parallel Plexiglas strips with the distance of the strips being equal to their thickness. Together with a Plexiglas cuboid the resolution patterns are mounted on a Plexiglas plate on the bottom of the cylindrical phantom. An aqueous solution of manganese chloride is used to fill the phantom. High resolution cross sections (pixel size: 50 microm) through the resolution patterns were measured to confirm the correct dimensions of the phantom. To verify the appropriateness of the 0.1 and 0.2 mm stacks micro-CT images with a pixel size of 25 microm were acquired additionally for both patterns. Besides visual inspection evaluation of the profile function of signal intensity across the stacks demonstrates that the resolution patterns are sufficiently correct. T(1)-weighted SE sequences with slightly different pixel sizes as well as T(1)- and T(2*)- weighted gradient echo sequences were applied to demonstrate some possible applications of this phantom. In conclusion, the proposed phantom is well suited to assess the spatial resolution qualitatively (i.e., visually) and quantitatively over a wide range in steps of 0.1 mm.

Humans↗

[Dose reduction in spiral-CT: detection of pulmonary coin lesions with and without anatomically adjusted modulation of tube current].

PURPOSE: To investigate the potential of projection angle-dependent anatomical adaptation of tube current to reduce dose in spiral CT examinations of the thorax without loss in detectability of pulmonary nodules and image quality. PATIENTS AND METHODS: Dose can be reduced for non-circular patient cross-sections without an increase in noise if the tube current is reduced at those angular positions where the patient diameter and, consequently, attenuation are small. The examinations were dose with SOMATOM Plus 4 (Siemens AG). CT projection data were analysed to determine the optimum tube current for each projection angle in real time. We compared image quality, done, and detection rates of pulmonary nodules for thoracic spiral CT examinations with and without online anatomically adapted tube current control in a group of 38 patients. Three radiologists counted all intrapulmonary nodules in consensus separated in three different groups (< 5 mm, 5-10 mm, > 10 mm). Image quality was evaluated in a scale from 1-3 (1 = very good, 2 = good, 3 = worse). RESULTS: On average, the dose was reduced by 21% (15-34%). With a constant tube current, 704 pulmonary nodules were detected, with tube current modulation 707 pulmonary nodules. For three patients we saw more pulmonary nodules (five) with tube current modulation, for two patients we saw less pulmonary nodules (two). In a direct comparison, the missed intrapulmonary nodules were also detected in the respective method. Thus, the detection rate of intrapulmonary nodules was uninfluenced. In general, no deterioration of image quality was observed. CONCLUSION: On average, 21% dose reduction was achieved by an anatomically adapted tube current modulation in spiral CT examinations of the thorax without a loss in detectability of pulmonary nodules and image quality. This method is an important contribution to dose reduction in spiral CT.

Diagnosis, Differential↗

Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT.

In modern computed tomography (CT) there is a strong desire to reduce patient dose and/or to improve image quality by increasing spatial resolution and decreasing image noise. These are conflicting demands since increasing resolution at a constant noise level or decreasing noise at a constant resolution level implies a higher demand on x-ray power and an increase of patient dose. X-ray tube power is limited due to technical reasons. We therefore developed a generalized multi-dimensional adaptive filtering approach that applies nonlinear filters in up to three dimensions in the raw data domain. This new method differs from approaches in the literature since our nonlinear filters are applied not only in the detector row direction but also in the view and in the z-direction. This true three-dimensional filtering improves the quantum statistics of a measured projection value proportional to the third power of the filter size. Resolution tradeoffs are shared among these three dimensions and thus are considerably smaller as compared to one-dimensional smoothing approaches. Patient data of spiral and sequential single- and multi-slice CT scans as well as simulated spiral cone-beam data were processed to evaluate these new approaches. Image quality was assessed by evaluation of difference images, by measuring the image noise and the noise reduction, and by calculating the image resolution using point spread functions. The use of generalized adaptive filters helps to reduce image noise or, alternatively, patient dose. Image noise structures, typically along the direction of the highest attenuation, are effectively reduced. Noise reduction values of typically 30%-60% can be achieved in noncylindrical body regions like the shoulder. The loss in image resolution remains below 5% for all cases. In addition, the new method has a great potential to reduce metal artifacts, e.g., in the hip region.

Algorithms↗

Advanced single-slice rebinning for tilted spiral cone-beam CT.

Future medical CT scanners and today's micro CT scanners demand cone-beam reconstruction algorithms that are capable of reconstructing data acquired from a tilted spiral trajectory where the vector of rotation is not necessarily parallel to the vector of table increment. For the medical CT scanner this case of nonparallel object motion is met for nonzero gantry tilt: the table moves into a direction that is not perpendicular to the plane of rotation. Since this is not a special application of medical CT but rather a daily routine in head exams, there is a strong need for corresponding reconstruction algorithms. In contrast to medical CT, where the special case of nonperpendicular motion is used on purpose, micro CT scanners cannot avoid aberrations of the rotational axis and the table increment vector due to alignment problems. Especially for those micro CT scanners that have the lifting stage mounted on the rotation table (in contrast to setups where the lifting stage holds the rotation table), this kind of misalignment is equivalent to a gantry tilt. We therefore generalize the advanced single-slice rebinning algorithm (ASSR), which is considered a very promising approach for medical cone-beam reconstruction due to its high image quality and its high reconstruction speed [Med. Phys. 27, 754-772 (2000)], to the case of tilted gantries. We evaluate this extended ASSR approach (which we will denote as ASSR+, for convenience) in comparison to the original ASSR algorithm using simulated phantom data for reconstruction. For the case of nonparallel object motion ASSR+ shows significant improvements over ASSR, however, its computational complexity is slightly increased due to the broken symmetry of the spiral trajectory.

Algorithms↗