Search PubMed⌕ Search

Biomedical subjects

W A Friedman

Publications and source records attributed to W A Friedman.

At least 37 records · Page 2Linked to original sources

Image registration of BANG gel dose maps for quantitative dosimetry verification.

BACKGROUND: The BANG (product symbol SGEL, MGS Research Inc., Guilford, CT) polymer gel has been shown to be a valuable dosimeter for determining three-dimensional (3D) dose distributions. Because the proton relaxation rate (R2) of the gel changes as a function of absorbed dose, MR scans of the irradiated gel can be used to generate 3D dose maps. Previous work with the gel, however, has not relied on precise localization of the measured dose distribution. This has limited its quantitative use, as no precise correlation exists with the planned distribution. This paper reports on a technique for providing this correlation, thus providing a quality assurance tool that includes all of the steps of imaging, treatment planning, dose calculation, and treatment localization. METHODS AND MATERIALS: The BANG gel formulation was prepared and poured into spherical flasks (15.3-cm inner diameter). A stereotactic head ring was attached to each flask. Three magnetic resonance imaging (MRI) and computed tomography (CT) compatible fiducial markers were placed on the flask, thus defining the central axial plane. A high-resolution CT scan was obtained of each flask. These images were transferred to a radiosurgery treatment-planning program, where treatment plans were developed. The gels were irradiated using our systems for stereotactic radiosurgery or fractionated stereotactic radiotherapy. The gels were MR imaged, and a relative 3D dose map was created from an R2 map of these images. The dose maps were transferred to an image-correlation program, and then fused to the treatment-planning CT scan through a rigid body match of the MRI/CT-compatible fiducial markers. The fused dose maps were imported into the treatment-planning system for quantitative comparison with the calculated treatment plans. RESULTS: Calculated and measured isodose surfaces agreed to within 2 mm at the worst points within the in-plane dose distributions. This agreement is excellent, considering that the pixel resolution of the MRI dose maps is 1.56 x 1.56 mm, and the treatment-planning dose distributions were calculated on a 1-mm dose grid. All points within the dose distribution were well within the tolerances set forth for commissioning and quality assurance of stereotactic treatment-planning systems. Moreover, the quantitative evaluation presented here tests the accuracy of the entire treatment-planning and delivery process, including stereotactic frame rigidity, CT localization, CT/MR correlation, dose calculation, and radiation delivery. CONCLUSION: BANG polymer gel dosimetry coupled with image correlation provides quantitative verification of the accuracy of 3D dose distributions. Such quantitative evaluation is imperative to ensure the high quality of the 3D dose distributions generated and delivered by stereotactic and other conformal irradiation systems.

Gels↗

A comparison of 3-D data correlation methods for fractionated stereotactic radiotherapy.

PURPOSE: Stereotactic radiosurgery is currently used to treat patients who are not good candidates for conventional neurosurgical procedures. For treatments of nonvascular tumor cells, it appears that fractionation offers a radiobiological advantage between tumor and normal tissues. Therefore, fractionated stereotactic radiotherapy (FSR) is preferred because it minimizes normal tissue complications and maximizes local tumor control probability. We have implemented a methodology clinically to perform the noninvasive patient repositioning technique. The 3-D data correlation method for high-precision and multiple fraction stereotactic treatments has been presented. METHODS AND MATERIALS: Three different optimization algorithms (Hooke and Jeeves optimization, simplex optimization, and simulated annealing optimization) are evaluated to calculate the transformation parameters necessary for FSR. A least-square object function is created to perform the 3-D data matching process. By minimizing the unconstrained object function value the best fit can be approached for the reference 3-D data sets. Simulation shows that these algorithms deliver results that are comparable to the previously published correlation algorithm (1,2) (singular value decomposition [SVD] method). The advantage for optimization algorithms is easily understood and can be readily implemented by using a personal computer (PC). The mathematical framework provides a tool to calculate the transformation matrix which can be used to adjust patient position for fractionated treatments. Therefore, using these algorithms for a high-precision fractionated treatment is possible without an invasive repeat fixation device and has been implemented clinically. A bite plate system was incorporated to acquire 3-D patient data. With a 3-D digital camera localization device, the patient motion can be followed in real time with the system calibrated to the isocenter. RESULTS: Two types of data sets are utilized to study the correlation results. One is using the digitized patient data which were retrieved clinically. The other is using the randomly generated data sets. Simulation errors for the optimization algorithms are all less than 1 mm in translation and less than 1 degree in rotation. Currently, FSR is performed using special designed repeat fixation devices which assure reproducible patient position for multiple fractions of radiation treatment. Clinical results indicated that this technique provided excellent treatment results. CONCLUSION: Three optimization algorithms have been applied and evaluated in calculating the transformation parameters between two 3-D contours or digitized data points. The mathematical functions behind these optimization algorithms are straightforward and can be easily implemented. When incorporated with the proper CT/MR image data with an electronic portal imaging (EPI) system, this process can possibly verify the patient's treatment position whenever there is doubt about the movement during the treatment procedure.

Algorithms↗

Linear accelerator radiosurgery for nonacoustic schwannomas.

PURPOSE: To analyze the results of nonacoustic schwannomas treated with linear accelerator stereotactic radiosurgery. METHODS AND MATERIALS: Between August 1989 and October 1997, 18 patients with nonacoustic schwannomas underwent stereotactic radiosurgery at the University of Florida. Nine patients had schwannomas located in the jugular foramen region, seven in the trigeminal nerve, and two in the facial nerve. Nine patients had initial subtotal resections and nine did not undergo surgical intervention. One of the 9 patients with subtotal resection was treated with radiosurgery for a recurrent tumor. Tumor volumes ranged from 0.7 to 15.4 cm3 with a mean volume of 5.5 cm3. Minimal tumor doses ranged from 10.0 to 15.0 Gy with a mean dose of 13.1 Gy. Treatment dose was specified to the 80% isodose shell in 11 patients (58%) and to the 70% isodose shell in the remaining patients. Ten patients (56%) were treated with a single isocenter, 6 patients (33%) with 2-4 isocenters, and 2 patients (11%) with greater than 5 isocenters. Follow-up ranged from 5 to75 months and the mean follow-up was 32 months. Ten patients (56%) had follow-up beyond 2 years and none were lost to follow-up. Local control was defined as clinically stable neurological status and/or stable or decreased tumor size on yearly follow-up MR imaging. RESULTS: Eighteen evaluable patients (100%) had local control after treatment. All were alive and progression-free at last follow-up. Six of 10 patients with follow-up MRI 2 years or more after treatment had tumor regression and 4 patients had stable disease. Three additional patients with an MRI at 1 year showed no tumor change. Four complications in 3 patients included one worsening of a preexisting VII nerve palsy, 2 patients with new onset of hearing loss, and one with ataxia. No surgical intervention or prolonged steroid use was necessary for any patient with complications. Five patients had improvement in preexisting neurologic deficits. CONCLUSIONS: Excellent preliminary tumor control rates and a favorable toxicity profile support the effectiveness of linear accelerator stereotactic radiosurgery for patients with nonacoustic schwannomas.

Adolescent↗

Linac radiosurgery for benign meningiomas.

PURPOSE: To review outcomes for patients treated with linac radiosurgery for benign meningiomas. METHODS AND MATERIALS: Between January 1989 and July 1997, 70 patients with 76 meningiomas were treated with LINAC-based radiosurgery. In 38 patients, radiosurgery was the initial treatment. In 32 patients, radiosurgery followed surgery or conventional radiotherapy. The average treatment volume was 10.0 cm3 (range, 0.6 to 28.6 cm3). The mean peripheral dose was 12.7 Gy (range, 10 to 20 Gy). The mean clinical follow-up period was 23 months. No patient was lost to follow-up. RESULTS: No lesions enlarged during the follow-up period; of 48 lesions in patients who had follow-up for at least one year and hence had follow-up imaging, 27 tumors remained unchanged and 21 tumors were reduced in size. Two patients experienced transient radiation-induced neurological deficits. One was treated with surgical excision of the tumor; the other responded to prolonged steroid therapy. Both patients, treated early in our experience, received doses higher than we would currently recommend. CONCLUSIONS: Early results suggest that stereotactic radiosurgery is an effective treatment for meningiomas. Long-term follow-up will be necessary to fully evaluate its efficacy.

Adult↗

Analytic characterization of linear accelerator radiosurgery dose distributions for fast optimization.

Linear accelerator (linac) radiosurgery utilizes non-coplanar arc therapy delivered through circular collimators. Generally, spherically symmetric arc sets are used, resulting in nominally spherical dose distributions. Various treatment planning parameters may be manipulated to provide dose conformation to irregular lesions. Iterative manipulation of these variables can be a difficult and time-consuming task, because (a) understanding the effect of these parameters is complicated and (b) three-dimensional (3D) dose calculations are computationally expensive. This manipulation can be simplified, however, because the prescription isodose surface for all single isocentre distributions can be approximated by conic sections. In this study, the effects of treatment planning parameter manipulation on the dimensions of the treatment isodose surface were determined empirically. These dimensions were then fitted to analytic functions, assuming that the dose distributions were characterized as conic sections. These analytic functions allowed real-time approximation of the 3D isodose surface. Iterative plan optimization, either manual or automated, is achieved more efficiently using this real time approximation of the dose matrix. Subsequent to iterative plan optimization, the analytic function is related back to the appropriate plan parameters, and the dose distribution is determined using conventional dosimetry calculations. This provides a pseudo-inverse approach to radiosurgery optimization, based solely on geometric considerations.

Humans↗

Linear accelerator radiosurgery in brain tumor management.

This article begins with a brief introduction to the concepts and techniques of linear accelerator-based stereotactic radiosurgery. The expanding role of radiosurgery in the treatment of brain tumors is explored in depth, including detailed discussions of the five intracranial neoplasms most frequently treated with radiosurgery. These include both benign (i.e., vestibular schwannoma, meningioma, pituitary adenoma) and malignant (i.e., cerebral metastasis, malignant glioma) pathologies. For each of these, a thorough review of published radiosurgical results is presented along with a discussion of common treatment modalities. The role of radiosurgery in the treatment of brain tumors continues to be defined, but an effort is made to provide reasonable indications for and against radiosurgery based on the current state of the art.

Adenoma↗

Preliminary experience with frameless stereotactic radiotherapy.

PURPOSE: To report initial clinical experience with a novel high-precision stereotactic radiotherapy system. METHODS AND MATERIALS: Sixty patients ranging in age from 2 to 82 years received a total of 1426 treatments with the University of Florida frameless stereotactic radiotherapy system. Of the total, 39 (65%) were treated with stereotactic radiotherapy (SRT) alone, and 21 (35%) received SRT as a component of radiotherapy. Pathologic diagnoses included meningiomas (15 patients), low-grade astrocytomas (11 patients), germinomas (9 patients), and craniopharyngiomas (5 patients). The technique was used as means of dose escalation in 11 patients (18%) with aggressive tumors. Treatment reproducibility was measured by comparing bite plate positioning registered by infrared light-emitting diodes (IRLEDs) with the stereotactic radiosurgery reference system, and with measurements from each treatment arc for the 1426 daily treatments (5808 positions). We chose 0.3 mm vector translation error and 0.3 degrees rotation about each axis as the maximum tolerated misalignment before treating each arc. RESULTS: With a mean follow-up of 11 months, 3 patients had recurrence of malignant disease. Acute side effects were minimal. Of 11 patients with low grade astrocytomas, 4 (36%) had cerebral edema and increased enhancement on MR scans in the first year, and 2 required steroids. All had resolution and marked tumor involution on follow-up imaging. Bite plate reproducibility was as follows. Translational errors: anterior-posterior, 0.01 +/- 0.10; lateral, 0.02 +/- 0.07; axial, 0.01 +/- 0.10. Rotational errors (degrees): anterior-posterior, 0.00 +/- 0.03; lateral, 0.00 +/- 0.06; axial, 0.01 +/- 0.04. No patient treatment was delivered beyond the maximum tolerated misalignment. Daily treatment was delivered in approximately 15 min per patient. CONCLUSION: Our initial experience with stereotactic radiotherapy using the infrared camera guidance system was good. Patient selection and treatment strategies are evolving rapidly. Treatment accuracy was the best reported, and the treatment approach was practical.

Adolescent↗

IRLED-based patient localization for linac radiosurgery.

PURPOSE: Currently, precise stereotactic radiosurgery delivery is possible with the Gamma Knife or floor-stand linear accelerator (linac) systems. Couch-mounted linac radiosurgery systems, while less expensive and more flexible than other radiosurgery delivery systems, have not demonstrated a comparable level of precision. This article reports on the development and testing of an optically guided positioning system designed to improve the precision of patient localization in couch-mounted linac radiosurgery systems. METHODS AND MATERIALS: The optically guided positioning system relies on detection of infrared light-emitting diodes (IRLEDs) attached to a standard target positioner. The IRLEDs are monitored by a commercially available camera system that is interfaced to a personal computer. An IRLED reference is established at the center of stereotactic space, and the computer reports the current position of the IRLEDs relative to this reference position. Using this readout from the computer, the correct stereotactic coordinate can be set directly. RESULTS: Bench testing was performed to compare the accuracy of the optically guided system with that of a floor-stand system, that can be considered an absolute reference. This testing showed that coordinate localization using the IRLED system to track translations agreed with the absolute to within 0.1 +/- 0.1 mm. As rotations for noncoplanar couch angles were included, the inaccuracy was increased to 0.2 +/- 0.1 mm. CONCLUSIONS: IRLED technology improves the accuracy of patient localization relative to the linac isocenter in comparison with conventional couch-mounted systems. Further, the patient's position can be monitored in real time as the couch is rotated for all treatment angles. Thus, any errors introduced by couch inaccuracies can be detected and corrected.

Humans↗

Treatment planning optimization for linear accelerator radiosurgery.

PURPOSE: Linear accelerator radiosurgery uses multiple arcs delivered through circular collimators to produce a nominally spherical dose distribution. Production of dose distributions that conform to irregular lesions or conformally avoid critical neural structures requires a detailed understanding of the available treatment planning parameters. METHODS AND MATERIALS: Treatment planning parameters that may be manipulated within a single isocenter to provide conformal avoidance and dose conformation to ellipsoidal lesions include differential arc weighting and gantry start/stop angles. More irregular lesions require the use of multiple isocenters. Iterative manipulation of treatment planning variables can be difficult and computationally expensive, especially if the effects of these manipulations are not well defined. Effects of treatment parameter manipulation are explained and illustrated. This is followed by description of the University of Florida Stereotactic Radiosurgery Treatment Planning Algorithm. This algorithm organizes the manipulations into a practical approach for radiosurgery treatment planning. RESULTS: Iterative treatment planning parameters may be efficiently manipulated to achieve optimal treatment plans by following the University of Florida Treatment Planning Algorithm. The ability to produce conformal stereotactic treatment plans using the algorithm is demonstrated for a variety of clinical presentations. CONCLUSION: The standard dose distribution produced in linear accelerator radiosurgery is spherical, but manipulation of available treatment planning parameters may result in optimal dose conformation. The University of Florida Treatment Planning Algorithm organizes available treatment parameters to efficiently produce conformal radiosurgery treatment plans.

Algorithms↗

Potential clinical efficacy of intensity-modulated conformal therapy.

PURPOSE: The purpose of this study was to examine the potential benefit of using intensity-modulated conformal therapy for a variety of lesions currently treated with stereotactic radiosurgery or conventional radiotherapy. METHODS AND MATERIALS: Intensity-modulated conformal treatment plans were generated for small intracranial lesions, as well as head and neck, lung, breast, and prostate cases, using the Peacock Plan treatment-planning system (Nomos Corporation). For small intracranial lesions, intensity-modulated conformal treatment plans were compared with stereotactic radiosurgery treatment plans generated for patient treatment at the University of Florida Shands Cancer Center. For other sites (head and neck, lung, breast, and prostate), plans generated using the Peacock Plan were compared with conventional treatment plans, as well as beam's-eye-view conformal treatment plans. Plan comparisons were accomplished through conventional qualitative review of two-dimensional (2D) dose distributions in conjunction with quantitative techniques, such as dose-volume histograms, dosimetric statistics, normal tissue complication probabilities, tumor control probabilities, and objective numerical scoring. RESULTS: For small intracranial lesions, there is little difference between intensity-modulated conformal treatment planning and radiosurgery treatment planning in the conformation of high isodose lines with the target volume. However, stereotactic treatment planning provides a steeper dose gradient outside the target volume and, hence, a lower normal tissue toxicity index. For extracranial sites, objective numerical scores for beam's-eye-view and intensity-modulated conformal planning techniques are superior to scores for conventional treatment plans. The beam's-eye-view planning technique prevents geographic target misses and better excludes healthy tissues from the treatment portal. Compared with scores for the beam's-eye-view planning technique, scores for intensity-modulated conformal plans using the Peacock Plan were significantly better for the lung and head and neck cases studied, equivalent for prostate cases, and inferior for breast cases. CONCLUSION: Using the entire 3D data set to construct radiotherapy plans through virtual simulation is always advantageous, whether done for stereotactic radiosurgery, beam's-eye-view conformal therapy, or intensity-modulated conformal treatment. Intensity modulation of the photon beam further enhances treatment planning under specific conditions. In general, the intensity-modulated technique is advantageous for large, irregular targets with critical structures in close proximity. Intensity-modulated treatment planning does not appear advantageous for stereotactic radiosurgery or treatment of the intact breast.

Aged↗

The radiobiology of radiosurgery and stereotactic radiotherapy.

Radiation therapy has evolved into a complex amalgamation of treatment techniques that differ significantly according to the way the radiation is delivered to the patient and coincidentally according to the biologic effects that are observed with each technique. Although there are concepts within radiobiology that unify the field, it is not apparent that the biologic effects with one methodology of treatment resemble those of another. Radiosurgery, although initially developed in the 1950s, has become more commonly used in recent years. This treatment involves high-dose, single-fraction treatments with sharp dose gradients to small volumes of tissue. This contrasts with conventional external-beam radiotherapy which involves small-dose, multiple-fraction, broad-dose-gradient treatment to relatively large volumes of tissue. Stereotactic radiotherapy generally delivers small-dose, multiple-fraction treatments to small or intermediate volumes of tissue with a sharp dose gradient compared with conventional external-beam treatment. A discussion of these technique differences with reference to the radiobiologic implications may help elucidate the potential utility of the techniques in clinical radiotherapy.

Brain Neoplasms↗

Linac scalpel radiosurgery at the University of Florida.

Optimal implementation of stereotactic radiosurgery requires multidisciplinary input from neurosurgeons, radiation oncologists, and physicists. Clinical processes of most importance to the physics staff include stereotactic imaging, treatment planning, and radiation delivery. Careful attention to each of these details helps to ensure the quality of the overall process. Here we provide a practical review of the clinical processes involved in linac scalpel radiosurgery. The linac scalpel system is a linear-accelerator-based radiosurgery system that was developed at the University of Florida. It has been used at the University of Florida to treat more than 1000 patients since 1988. The aim of the linac scalpel system is to minimize all possible uncertainties in imaging and treatment delivery. Once these errors are minimized, truly conformal treatment plans can be generated and delivered with confidence, allowing clinicians to focus solely on the patient's problem. By following practical examples of this well established system, many pitfalls in the clinical process can be avoided.

Cerebral Angiography↗

Optic-guided stereotactic radiotherapy.

Stereotactic localization provides a powerful referencing system for radiation planning and treatment delivery. Although the standard approach of applying a rigid reference frame has been accepted for single-fraction therapy, a new, noninvasive approach is needed for fractionated therapy. The use of optical tracking allows a patient's position to be monitored in real time with a truly touch-free system. Our optical system provides high precision and accuracy for repeat fixation and can be applied to a wide spectrum of patients. With this system, a stereotactic radiation treatment can be delivered in the same length of time as a routine fractionated radiation treatment.

Brain Neoplasms↗

Calcified cystic lesions in a patient with epilepsy and progressive dementia.

A 67-year-old woman had intractable epilepsy and developed a progressive dementia with upper motor neuron signs over the last 6 years. Magnetic resonance imaging (MRI) revealed multiple areas of large calcified cysts, which increased in number and size over the last 3 years. Discussion includes the appearance of these lesions radiologically and pathologically, as well as their differential diagnosis and clinical significance, focusing on the increasing detection of these lesions with current imaging techniques.

Aged↗

The effect of LINAC stereotactic radiosurgery on epilepsy associated with arteriovenous malformations.

Reduction of seizures associated with arteriovenous malformations (AVMs) following radiosurgery has been reported. This investigation assessed the effect of LINAC radiosurgical treatment of AVMs on the associated epilepsies correlated to AVM location, size, seizure type, and postradiosurgical thrombosis. Of 100 patients with AVMs, 33 presented with seizures (11 generalized tonic-clonic seizures, 8 simple partial seizures, and 14 complex partial seizures with or without secondary generalization). Patients with AVMs >/=25.0 mm were more likely to have seizures. Patients with frontal lobe AVMs were the most likely to have associated epilepsy (72.7%). Following radiosurgery, 59% were seizure-free and 19% had marked reduction of seizure frequency. Seizure remission was most frequent for AVMs of the centrum (83.3%). Of 14 patients with 2-year follow-up angiography, 9 had complete thrombosis and 6 became seizure-free. Four of 5 patients without thrombosis also became seizure-free. We conclude that LINAC radiosurgery is effective for epilepsies associated with AVMs. Radiosurgery was most effective for generalized tonic-clonic and complex partial seizures. There was no statistically significant correlation between reduction in epilepsy and original AVM size. Four of 5 patients without thrombosis became seizure-free, suggesting that structural or biochemical alterations of epileptogenic neurons following radiosurgery may reduce epileptogenicity.

Adult↗