Search PubMed⌕ Search

Biomedical subjects

Vu M Mai

Publications and source records attributed to Vu M Mai.

5 recordsLinked to original sources

Computing oxygen-enhanced ventilation maps using correlation analysis.

Correlation maps of oxygen-enhanced ventilation were obtained in nine healthy volunteers using complete and selected image series. The complete series included all images acquired with the subjects alternately inhaling room air and 100% oxygen. The selected series were the subsets of the complete series and included only co-registered images that showed matched diaphragmatic position at maximal expiration. Cross-correlation was computed between the time response function of each pixel and the input function representing the alternation between periods of room air and 100% oxygen inhalation. The confidence level for the correlation analysis was set to 0.01. Pulmonary parenchymal anatomy was consistently reproduced throughout the lung, even in anterior slices where published data have reported correlation problems. The overall average correlation coefficient was 0.66 +/- 0.07 for the complete series and 0.75 +/- 0.08 for the selected series. It was concluded that correlation analysis could be used to reconstruct qualitative oxygen-enhanced ventilation maps.

Adult↗

Influence of oxygen flow rate on signal and T(1) changes in oxygen-enhanced ventilation imaging.

PURPOSE: To investigate the optimal oxygen flow rate for oxygen-enhanced MR ventilation imaging. MATERIALS AND METHODS: Using a cardiac-triggered nonselective inversion recovery (IR) half Fourier single-shot fast spin echo sequence, series of images were acquired with the subject alternately inhaling room air and 100% oxygen. Oxygen flow rates of 5 L/min, 10 L/min, 15 L/min, 20 L/min, and 25 L/min were studied, and signal intensity from the oxygen-enhanced ventilation images and T(1) of the lung were measured. RESULTS: The average signal intensity was 63.0 +/- 21.0 for 5 L/min, 98.7 +/- 26.8 for 10 L/min, 133.8 +/- 20.0 for 15 L/min, 138.7 +/- 19.7 for 20 L/min, and 139.2 +/- 37.9 for 25 L/min. The average T(1)'s of the lung were 1399 msec +/- 130 msec for room air, 1314 msec +/- 101 msec for 5 L/min, 1276 msec +/- 105 msec for 10 L/min, 1207 msec +/- 71 msec for 15 L/min, 1206 msec +/- 90 msec for 20 L/min, and 1207 msec +/- 42 msec for 25 L/min. CONCLUSION: The optimal flow rate is 15 L/min for oxygen-enhanced ventilation imaging.

Adult↗

Comparison of first-pass Gd-DOTA and FAIRER MR perfusion imaging in a rabbit model of pulmonary embolism.

PURPOSE: To compare the sensitivity of contrast-enhanced magnetic resonance imaging (MRI) and arterial spin labeling to perfusion deficits in the lung. MATERIALS AND METHODS: A rabbit model of pulmonary embolism was imaged with both flow-sensitive alternating inversion recovery with an extra radiofrequency pulse (FAIRER) arterial spin labeling and Gd-DOTA enhanced MRI. The signal-to-noise ratio (SNR) was measured in the area of the perfusion deficit and the normal lung for both techniques. RESULTS: The defect was readily visible in all images. The normal lung had an average of 3.8 +/- 1.2 times the SNR of the unperfused lung with the arterial spin labeling technique, and approximately 13.7 +/- 3.3 times the SNR with the contrast-enhanced technique. CONCLUSION: Gd-DOTA enhanced MRI provides higher SNR in pulmonary perfusion imaging; however, arterial spin labeling is also adequate and may be used when repeated studies are indicated.

Animals↗

MR assessment of left ventricular function: quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient echo cine technique.

PURPOSE: To evaluate the agreement of fast imaging employing steady-state acquisition (FIESTA) cine technique with segmented k-space fast gradient echo (GRE) cine technique when using them for assessment of cardiac function. MATERIALS AND METHODS: Eleven MR cine studies were performed on six healthy volunteers and five patients, using FIESTA and fast GRE techniques. The quantitative measurements of ventricular function obtained from the two techniques were compared. The data analysis was performed by two observers independently. RESULTS: Compared to fast GRE cine technique, FIESTA cine technique consistently resulted in higher end-diastolic volume (10.2%) and end-systolic volume (21.6%), but lower myocardial mass of left ventricle (19.2%) and ejection fraction (9.9%). The stroke volume obtained from the two techniques was very close. The primary explanation for this variability is that the two techniques have different mechanisms on establishing signal contrast. CONCLUSION: Compared to fast GRE technique, FIESTA provides significantly different results when using it for assessment of left ventricular function. It is important to consider this difference in the assessment of cardiac function.

Adult↗

Ventilation-perfusion ratio of signal intensity in human lung using oxygen-enhanced and arterial spin labeling techniques.

This study investigates the distribution of ventilation-perfusion (V/Q) signal intensity (SI) ratios using oxygen-enhanced and arterial spin labeling (ASL) techniques in the lungs of 10 healthy volunteers. Ventilation and perfusion images were simultaneously acquired using the flow-sensitive alternating inversion recovery (FAIR) method as volunteers alternately inhaled room air and 100% oxygen. Images of the T(1) distribution were calculated for five volunteers for both selective (T(1f)) and nonselective (T(1)) inversion. The average T(1) was 1360 ms +/- 116 ms, and the average T(1f) was 1012 ms +/- 112 ms, yielding a difference that is statistically significant (P < 0.002). Excluding large pulmonary vessels, the average V/Q SI ratios were 0.355 +/- 0.073 for the left lung and 0.371 +/- 0.093 for the right lung, which are in agreement with the theoretical V/Q SI ratio. Plots of the V/Q SI ratio are similar to the logarithmic normal distribution obtained by multiple inert gas elimination techniques, with a range of ratios matching ventilation and perfusion. This MRI V/Q technique is completely noninvasive and does not involve ionized radiation. A limitation of this method is the nonsimultaneous acquisition of perfusion and ventilation data, with oxygen administered only for the ventilation data.

Adult↗