Search PubMed⌕ Search

Biomedical subjects

Volker Hietschold

Publications and source records attributed to Volker Hietschold.

6 recordsLinked to original sources

External compression increases forearm perfusion.

Application of compression stockings to the lower extremities is a widely used therapeutic intervention to improve venous return, but there is little information about the effects of compression on local arterial perfusion. Therefore, we tested the hypothesis that a positive external pressure increases forearm perfusion. The relation of increasing external pressure induced by standardized compression to the arterial inflow and arterial flow reserve of the forearm was critically evaluated in a group of healthy young men (n = 9). Flow was measured with venous occlusion plethysmography after a 10-min application of six different stockings with compression pressure increasing from 13 to 23 mmHg. During compression, the arterial inflow increased significantly from 3.7 +/- 0.85 to 8.8 +/- 2.01 ml.min(-1).100 ml tissue(-1) (P < 0.001) and the arterial flow reserve increased from 17.7 +/- 4.7 to 28.3 +/- 7.0 ml.min(-1).100 ml tissue(-1). The flow increase was persistent after 3 h of constant application of external pressure and also during simultaneous low-intensity hand grip. Similar results obtained with occlusion plethysmography were seen with MRI. During the interventions, forearm temperature was unchanged, and the volunteers reported no discomfort. In conclusion, 1) arterial perfusion of the human forearm increases more than twofold during application of external compression over a pressure range of 13-23 mmHg, and 2) the result is interpreted as an autoregulatory response following the decrease of the vascular transmural pressure gradient.

Adult↗

MR perfusion measurements on pharyngeal tumors: comparison of quantification strategies.

For the case of pharyngeal carcinomas, the clinical value as well as the stability of several evaluation methods of MR tomographic perfusion measurement are compared. Eighteen patients suffering from histologically proven squamous cell carcinomas were investigated by MR tomography (1.5 T, 0.2 mmol/kg Gd-DTPA) prior to and during radiation therapy. Perfusion measurements were performed using a double-echo FLASH sequence. Parameters describing regional blood flow, blood volume, mean transit time, and interstitial concentration of contrast medium (CM) were calculated, applying seven different combinations of correction approaches (separating the shortening of T1 and T2*, arterial input function (AIF), and tumor shunts). Their correlations to MR independent tumor physiological parameters were analyzed (metabolic activity measurements using 18F-FDG-PET, polarographical pO2 measurement, tumor volume). Significant improvements of the correlation between perfusion-dependent and other tumor physiological parameters could be achieved by decoupling the shortening of T1 and T2* and by applying of the tumor shunt model. Deconvolution from the AIF deteriorated the correlation. Therefore, the elimination of the T1 shortening due to interstitial CM proves to be essential for MR perfusion measurements on contrast medium uptaking lesions. Depending on the measurement conditions (temporal resolution, signal-to-noise ratio), the consideration of the AIF can even make the results significantly worse by introducing additional measuring errors.

Adult↗

MRI of the coronary arteries: flip angle train optimization for 3D sequences.

Application of contrast agents in MRI of coronary arteries improves contrast-to-noise ratio (CNR), but widens the range of T1 relaxation times of the tissues to be imaged. The flip angle train, generated for the measurement of all phase-encoding steps in the 3rd spatial dimension of the navigator echo FLASH sequence used, is optimal only for one T1. Computer simulations show that it is not advisable to optimize the sequence on the basis of an extremely short T1 relaxation time (such as in the case of contrast-enhanced vessels) because the imaging of the surrounding tissue would be negatively influenced. A sequence optimization to a T1 of approximately 200 ms seems to allow a CNR improvement of > or = 50%.

Computer Simulation↗

MR evaluation in patients with isolated anosmia since birth or early childhood.

BACKGROUND AND PURPOSE: Anosmias with chromosomal disorders has been well investigated. However, isolated anosmia (IA) has received less attention, although it occurs more frequently. We compared frontobasal structures in patients with IA since birth or early childhood with those in control subjects. METHODS: Imaging findings obtained in 16 patients with IA were compared with those obtained in eight control subjects. Imaging was performed with a standard quadrature head coil at 1.5 T. T1-weighted spin-echo (coronal plane perpendicular to frontal skull base; section thickness, 3 mm; pixels, 0.43 x 0.39 mm) and sagittal T1-weighted magnetization-prepared rapid gradient-echo (voxels, 1.0 x 1.0 x 1.0 mm) sequences were performed. We assessed the length and depth of the olfactory sulcus, olfactory bulb volume, and olfactory sulcus depth in the plane of the posterior tangent through the eyeballs (PPTE). RESULTS: Five patients with IA had bilateral hypoplastic olfactory bulbs. Three patients with IA had hypoplastic olfactory bulbs on the right and aplastic olfactory bulbs on the left. Eight patients with IA had bilaterally aplastic olfactory bulbs. The depth of the olfactory sulcus at the level of the PPTE was smaller in patients with IA than in control subjects. The depth of the olfactory sulcus was greater on the right than on the left, and there was no overlap. Among patients with IA, the depth of the olfactory sulcus differed significantly between those with and those without visible olfactory tracts. CONCLUSION: The depth of the olfactory sulcus at the level of the PPTE reflects the presence of olfactory tracts. The presence or absence of the olfactory tract may therefore have some association with cortical growth of the olfactory sulcus region. The olfactory sulcus is deeper on the right than on the left, particularly in patients with IA. We speculate that olfaction may be processed predominantly in the right hemisphere.

Adolescent↗

Gadomer-17-enhanced 3D navigator-echo MR angiography of the pulmonary arteries in pigs.

The goal of this study was visualisation and quality assessment of the pulmonary arteries in pigs with modified navigator-echo magnetic resonance angiography using an intravascular contrast agent. Five sedated pigs were examined in a clinical 1.5-T system with modified three-dimensional navigator-echo magnetic resonance angiography (slice thickness 3 mm, pixel size 2.4x1.8 mm2) to evaluate the pulmonary arteries. Using a phased-array four-element thorax coil the entire thorax was scanned before and after intravenous infusion of a gadolinium-based intravascular contrast agent. Assessment of image quality, enhancement-related contrast-to-noise ratio (CNR) measurements and improvement of visibility of peripheral pulmonary vessels was performed. Improvement of quality using Gadomer-17 was found for smaller vessels; pulmonary trunks and the main pulmonary arteries were sufficiently imaged without enhancement. Mean rise of CNR measured in the pulmonary trunks was 28.64% ( P=0.0002), mean rise of CNR in the main pulmonary arteries and the segmental arteries were 79.6% and 148.2%, respectively. Mean distance between the visible peripheral end of 60 sub-segmental arteries and the inner thoracic wall was 12.2 +/- 0.4 mm, and was significantly ( P=0.00002) reduced after contrast infusion to 8.0 +/- 0.4 mm. The combination of inherent flow sensitivity of navigator-echo angiography and Gadomer-17 proved effective for imaging of the pulmonary arteries. In contrast to standard contrast-enhanced pulmonary MRA studies, breath holding is not required. Further studies and the evaluation of findings of patients suffering from pulmonary embolism are needed to evaluate the possible benefits of a higher spatial resolution which is achievable using navigator-echo techniques in contrast to the higher temporal resolution of ultra-fast pulmonary MRA.

Animals↗