Search PubMed⌕ Search

Biomedical subjects

Vitalii V Itskovich

Publications and source records attributed to Vitalii V Itskovich.

11 recordsLinked to original sources

Gradient echo acquisition for superparamagnetic particles with positive contrast (GRASP): sequence characterization in membrane and glass superparamagnetic iron oxide phantoms at 1.5T and 3T.

Iron oxides are used for cell trafficking and identification of macrophages in plaque using MRI. Due to the negative contrast, differentiation between signal loss caused by iron and native low signal in tissue may be problematic. It is, therefore, preferable to achieve positive contrast. The purpose of this study was to test the efficacy of a new MRI sequence GRASP (GRe Acquisition for Superparamagnetic Particles) to generate a positive signal in phantoms containing iron. Membrane phantoms were constructed containing Ferumoxide at 7 concentrations. Standard GRE sequences were modified with user controlled z-gradient rephasing (+/- 100%). CNR values were determined as a function of echo time (TE) and % rephasing at 1.5T and 3T. T(2)* values were determined using multiple double-echo GRE. The GRASP sequence generated positive signal enhancement in phantoms containing iron. For all rephasing values <or=30%, positive contrast was observed. The CNR generated at 1.5T was greater than the values at 3T for all concentrations tested. Correlation between CNR at 0% and 100% rephasing was observed at 1.5T(R = 0.84). Additionally, correlation between field change across the volume and CNR was observed. In conclusion, GRASP sequences may be used to generate positive signal enhancement in the presence of iron using MRI.

Artifacts↗

Carotid black blood MRI burden of atherosclerotic disease assessment correlates with ultrasound intima-media thickness.

The aim of this study was to correlate carotid black blood MRI based measurements with those obtained by ultrasound intima-media thickness (IMT). Seventeen patients with intermediate to high Framingham cardiovascular risk score underwent both carotid ultrasound and rapid extended coverage double inversion recovery black blood carotid MRI. Overall, there was good correlation between wall area, wall thickness, and plaque index measured by MRI and the IMT measurements obtained from the ultrasound images (max r2 = 0.72, p < 0.05). Patients with mean IMT > or = 1.2 mm had significantly higher values of wall area, plaque index and wall thickness compared to patients with mean IMT < 1.2 mm. Vessel wall measurements assessed by black-blood MRI may be potentially used clinically to evaluate plaque progression and regression.

Aged↗

Comparison of gated and non-gated fast multislice black-blood carotid imaging using rapid extended coverage and inflow/outflow saturation techniques.

PURPOSE: To comparatively analyze two fast in vivo multislice black-blood carotid artery vessel wall imaging techniques with and without cardiac gating. MATERIALS AND METHODS: Eight subjects with carotid artery atherosclerosis, and four healthy subjects were studied using two black-blood multislice techniques: rapid extended coverage double inversion recovery (REX-DIR), and inflow/outflow saturation band (IOSB) rapid acquisition with relaxation enhancement (RARE) multislice acquisitions. Quantitative, qualitative, and morphometric analyses were performed on images. RESULTS: Gating produced significantly lower values for the REX-DIR sequence with respect to signal intensity in muscle and the carotid artery wall, whereas it had no effect on flow suppression compared to non-gated images. For the IOSB sequences, gating had no significant effect on signal intensity of muscle and the carotid artery wall, but worsened flow suppression. REX-DIR and IOSB sequences were statistically different with respect to signal intensity of muscle (with REX-DIR sequences having lower values), while no statistical significance was observed for flow suppression and wall delineation. A morphologic analysis of the vessel wall and lumen comparing REX-DIR gated, IOSB gated, REX-DIR non-gated, and IOSB non-gated sequences revealed no significant differences between the acquisition techniques tested. CONCLUSION: Non-gated sequences may be used instead of gated sequences in atherosclerotic vessel wall imaging without compromising image quality. This may shorten examination time and improve patient comfort.

Adolescent↗

Serial studies of mouse atherosclerosis by in vivo magnetic resonance imaging detect lesion regression after correction of dyslipidemia.

OBJECTIVE: We determined the effects of sustained normocholesterolemia on advanced mouse atherosclerosis and whether changes in plaque size and composition can be detected noninvasively by MRI. METHODS AND RESULTS: Aortic arch segments containing advanced lesions from apolipoprotein E-deficient (apoE-/-) mice (total cholesterol 1281+/-97 mg/dL) were transplanted into syngeneic wild-type (WT; 111+/-11 mg/dL) or apoE-/- (702+/-74 mg/dL) recipient mice on chow diet. Mice underwent serial MRI at 3, 5, 7, and 9 weeks after transplantation. Compared with 3 weeks, correction of dyslipidemia in WT recipient mice resulted in a monotonic decrease (regression) in arterial wall volume, whereas in apoE-/- recipient mice, further plaque progression was noted (P<0.05). MRI and histological measurements were closely correlated (R=0.937). The lesional content of macrophages decreased >90% (P<0.001), and smooth muscle cells increased in the WT recipient mice. In vivo T(1)-, T(2)-, and proton density-weighted images of the mouse thoracic aorta differentiated intraplaque lipid and collagen. CONCLUSIONS: Plaque changes can be noninvasively monitored by serial in vivo MRI of a mouse regression model. Our ability to image the thoracic aorta and perform in vivo plaque characterization will further enhance atherosclerosis studies. Serial in vivo MRI of mouse arterial plaque after correction of dyslipidemia revealed a monotonic decrease in lesion size (regression) and changes in lesion composition consistent with a stable plaque phenotype. Serial in vivo MRI will enhance studies of plaque regression in animal models in response to therapeutic interventions.

Animals↗

Lipid-rich atherosclerotic plaques detected by gadofluorine-enhanced in vivo magnetic resonance imaging.

BACKGROUND: MRI of specific components in atherosclerotic plaque may provide information on plaque stability and its potential to rupture. We evaluated gadofluorine in atherosclerotic rabbits using a new MR sequence that allows plaque detection within 1 hour after injection and assessed enhancement in lipid-rich and non-lipid-rich plaques. METHODS AND RESULTS: Twelve rabbits with aortic plaque and 6 controls underwent MRI before and up to 24 hours after gadofluorine injection (50 micromol/kg). Two T1-weighted, segmented gradient-echo sequences (TFL) were compared to enhance vessel wall delineation after injection: (1) an inversion-recovery prepulse (IR-TFL) or (2) a combination of inversion-recovery and diffusion-based flow suppression prepulses (IR-DIFF-TFL). With the use of IR-TFL at 1 hour after injection, the vessel wall was not delineated because of poor flow suppression; at 24 hours after injection, the enhancement was 37% (P<0.01). IR-DIFF-TFL showed significant enhancement after versus before contrast (1 hour: 164% [P<0.005]; 24 hours: 207% [P<0.001]). At 1 hour and 24 hours after injection, the contrast-to-noise ratio was higher with the use of IR-DIFF-TFL than with IR-TFL (1 hour: 13.0+/-7.7 versus -19.8+/-10.3 [P<0.001]; 24 hours: 15.2+/-5.9 versus 11.4+/-8.9, respectively [P=0.052]). There was no enhancement in the vessel wall after gadofluorine injection in the control group. A strong correlation was found (r2=0.87; P<0.001) between the lipid-rich areas in histological sections and signal intensity in corresponding MR images. This suggests a high affinity of gadofluorine for lipid-rich plaques. CONCLUSIONS: Gadofluorine-enhanced MRI improves atherosclerotic plaque detection. The IR-DIFF-TFL method allows early detection of atherosclerotic plaque within 1 hour after gadofluorine injection.

Animals↗

Prenatal detection of embryo resorption in osteopontin-deficient mice using serial noninvasive magnetic resonance microscopy.

Appropriate temporal and spatial expression of osteopontin (OPN) in the female genital tract may be critical for successful embryo implantation and maintenance of gestation. Traditionally, experimental assessments of reproductive success have been limited to ex vivo dissection at a single time point to determine embryo number and size and are inadequate for ongoing study of the effect(s) of genetic manipulation on any individual gestation. To investigate the role of OPN in the maintenance of gestation, we developed a noninvasive, in vivo method of pregnancy surveillance suitable for murine application using magnetic resonance microscopy (MRM). Gravid wild-type mice (n =7) and mice with targeted disruption of one or both OPN alleles (OPN(-/-), n = 9; OPN(+/-), n = 3) underwent MRM on postcoital days 10.5, 15.5, and 19.5. Prenatal MRM images were used to determine embryo numbers and sizes. There were no significant differences in embryo numbers determined independently by two blinded observers (mean difference between observers = 0.04 embryos; p = 0.87). There was a significant effect of genotype on embryo size, with OPN(-/-) embryos significantly smaller at all gestational ages. However, targeted disruption of one or more OPN alleles had no effect on embryo number at any gestational age. Thus, MRM may be a powerful noninvasive method for in vivo prenatal developmental study of genetically engineered mice.

Animals↗

Parallel and nonparallel simultaneous multislice black-blood double inversion recovery techniques for vessel wall imaging.

PURPOSE: To reduce long examination times of black-blood vessel wall imaging by acquiring multiple slices simultaneously and by using parallel acquisition techniques. MATERIALS AND METHODS: DIR-rapid acquisition with relaxation enhancement (RARE) techniques imaging up to 10 simultaneous slices per acquisition with single and multiple 180 degrees -reinversion pulses were developed. A slab-selective reinversion multislice DIR-RARE sequence incorporating generalized autocalibrating partially parallel acquisitions (GRAPPA) imaging was implemented. Four-channel and eight-channel carotid coils were built to test these sequences. A total of 11 subjects were studied. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) efficiency factor (SEF, SNR/unit time/slice) were measured from aortic images of three healthy subjects to determine optimal MR parameters. The DIR-RARE-GRAPPA sequence was run on aortas and carotid arteries of the five remaining healthy subjects and three atherosclerotic patients with optimal parameters (acquisition times 12-21 seconds). RESULTS: SEFs of slab-selective protocols were significantly higher than those of slice-selective protocols, and SEFs of DIR-RARE-GRAPPA protocols were significantly higher than corresponding non-GRAPPA protocols (P < 0.05). CNR was not significantly different for all imaging protocols. The DIR-RARE-GRAPPA multislice sequence showed 8.35-fold time improvement vs. single-slice DIR-2RARE sequence. CONCLUSION: Future MRI atherosclerotic plaque studies can be performed in substantially shorter times using these methods.

Adult↗

Quantification of human atherosclerotic plaques using spatially enhanced cluster analysis of multicontrast-weighted magnetic resonance images.

One of the current limitations of magnetic resonance imaging (MRI) is the lack of an objective method to classify plaque components. Here we present a cluster analysis technique that can objectively quantify and classify MR images of atherosclerotic plaques. We obtained three-dimensional (3D) images from 12 human coronary artery specimens on a 9.4T imaging system using multicontrast-weighted fast spin-echo (T1-, proton density-, and T2-weighted) imaging with an isotropic voxel size of 39 micro. Spatially enhanced cluster analysis (SECA) was performed on multicontrast MR images, and the resulting segmentation was evaluated against histological tracings. To visualize the overall structure of plaques, the MR images were rendered in 3D. The specimens exhibited lesions of American Heart Association (AHA) plaque classification types I-VI. Both MR images and histological sections were independently reviewed, categorized, and compared. Overall, the classification obtained from the cluster-analyzed MR and histopathology images showed very good agreement for all AHA types (92%, Cohen's kappa = 0.89, P < 0.0001). All plaque types were identified and quantified by SECA with a high degree of correlation between cluster-analyzed MR and manually traced histopathology data. MRI combined with SECA provides an objective method for atherosclerotic plaque component characterization and quantification.

Analysis of Variance↗

Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging.

A two-dimensional rapid extended coverage (REX) rapid acquisition with relaxation enhancement (RARE) pulse sequence for simultaneous multisection double inversion-recovery (DIR) black-blood vessel wall magnetic resonance (MR) imaging was developed. Aortic vessel wall MR imaging was performed in five healthy subjects (mean age, 33 years +/- 4 [SD]) and five patients with atherosclerotic disease (mean age, 67 years +/- 11.7). Shortening of blood inversion time and imaging of multiple sections after single DIR block resulted in simultaneous acquisition of up to 20 aortic wall sections in less than 1 minute (spatial resolution, 0.97 x 0.97 x 3 mm(3)). Higher signal-to-noise ratios per unit time per section (16.0 +/- 2.45 vs 7.5 +/- 1.10, P <.05), no significant changes in contrast-to-noise ratios (15.0 +/- 5.3 vs 20.1 +/- 3.9, P >.05), and 17-fold improvement in acquisition time compared with those at conventional single-section DIR RARE imaging was achieved. Use of the REX method significantly shortened aortic imaging acquisition times without degrading image quality.

Adult↗

Serial, noninvasive, in vivo magnetic resonance microscopy detects the development of atherosclerosis in apolipoprotein E-deficient mice and its progression by arterial wall remodeling.

PURPOSE: To test the ability of serial, in vivo magnetic resonance microscopy (MRM) to detect the development of atherosclerosis and quantify its progression in apolipoprotein E-deficient mice. MATERIALS AND METHODS: The abdominal aortae of six ApoE(-/-) and three wild-type (WT) control mice were imaged by MRM at 9.4T. Proton density weighted images were obtained (TR = 2000, TE = 9 msec) using four signal averages. The image resolution was 109 x 109 x 500 microm(3). The six ApoE(-/-) mice underwent serial MRM three to five times over a period < or = 44 weeks. Multiple, anatomically aligned MRM slices (N = 6-11 per time point, total 202) were compared serially in each animal. RESULTS: The abdominal aorta remained free of atherosclerosis until 20 weeks of age but thereafter, atherosclerosis was identified in all ApoE(-/-) mice (P < 0.05 to P < 0.001), but no WT controls. Lesion progression was accompanied by positive remodeling in which atherosclerosis within the aortic wall was accommodated by an increase in total cross sectional area (P < 0.01), while lumen area was unchanged. CONCLUSION: Serial MRM demonstrated the development and progression of atherosclerosis in mouse aorta. Importantly, progression of atherosclerosis could be identified within individual animals. By following the same aortic lesions over time, MRM demonstrated that progression of atherosclerosis in mice is associated with positive arterial remodeling.

Animals↗

Magnetic resonance microscopy quantifies the disease progression in Marfan syndrome mice.

PURPOSE: To use noninvasive magnetic resonance microscopy (MRM) to examine aneurysmal disease in the mouse model of Marfan syndrome (MFS). MATERIALS AND METHODS: A total of eight wild-type (WT) and MFS mice were imaged using MRM; four of them at three different time points over an 8-week period and the remaining animals were imaged at one time point. The maximal cross-sectional area of the aorta was measured by manual tracing and by automated means from combined cardiac and respiratory-gated bright-blood images. Relationships between aortic size and age and the differences between WT and mutant mice aortic size were established. RESULTS: Maximal cross-sectional aortic areas differed significantly (P < 0.05) between WT and mutant mice for all time points, with MFS mice having larger aortic size. There was a positive correlation between aortic size and age in MFS mice (r = 0.80) with a significant increase from the 14th to the 22nd week (P < 0.05). CONCLUSION: MRM detected the differences in aortic size between WT and mutant mice over time, demonstrating a potential for noninvasive technique for the assessment of potential therapies in MFS mice.

Analysis of Variance↗