Search PubMed⌕ Search

Biomedical subjects

Vincent Linder

Publications and source records attributed to Vincent Linder.

9 recordsLinked to original sources

Characterization of a microfluidic dispensing system for localised stimulation of cellular networks.

We present a 3-D microfluidic device designed for localized drug delivery to cellular networks. The device features a flow cell comprising a main channel for nutrient delivery as well as multiple channels for drug delivery. This device is one key component of a larger, fully integrated system now under development, based upon a microelectrode array (MEA) with on-chip CMOS circuitry for recording and stimulation of electrogenic cells (e.g. neurons, cardiomyocytes). As a critical system unit, the microfluidics must be carefully designed and characterized to ensure that candidate drugs are delivered to specific regions of the culture at known concentrations. Furthermore, microfluidic design and functionality is dictated by the size, geometry, and material/electrical characteristics of the CMOS MEA. Therefore, this paper reports on the design considerations and fabrication of the flow cell, including theoretical and experimental analysis of the mass transfer properties of the nutrient and drug flows, which are in good agreement with one another. To demonstrate proof of concept, the flow cell was mounted on a dummy CMOS chip, which had been plated with HL-1 cardiomyocytes. A test chemical compound was delivered to the cell culture in a spatially resolved manner. Envisioned applications of this stand-alone system include simultaneous toxicological testing of multiple compounds and chemical stimulation of natural neural networks for neuroscience investigations.

Algorithms↗

Microfluidics/CMOS orthogonal capabilities for cell biology.

The study of individual cells and cellular networks can greatly benefit from the capabilities of microfabricated devices for the stimulation and the recording of electrical cellular events. In this contribution, we describe the development of a device, which combines capabilities for both electrical and pharmacological cell stimulation, and the subsequent recording of electrical cellular activity. The device combines the unique advantages of integrated circuitry (CMOS technology) for signal processing and microfluidics for drug delivery. Both techniques are ideally suited to study electrogenic mammalian cells, because feature sizes are of the same order as the cell diameter, approximately 50 microm. Despite these attractive features, we observe a size mismatch between microfluidic devices, with bulky fluidic connections to the outside world, and highly miniaturized CMOS chips. To overcome this problem, we developed a microfluidic flow cell that accommodates a small CMOS chip. We simulated the performances of a flow cell based on a 3-D microfluidic system, and then fabricated the device to experimentally verify the nutrient delivery and localized drug delivery performance. The flow-cell has a constant nutrient flow, and six drug inlets that can individually deliver a drug to the cells. The experimental analysis of the nutrient and drug flow mass transfer properties in the flowcell are in good agreement with our simulations. For an experimental proof-of-principle, we successfully delivered, in a spatially resolved manner, a 'drug' to a culture of HL-1 cardiac myocytes.

Cell Culture Techniques↗

Space- and time-resolved spectrophotometry in microsystems.

This work describes a simple optical method for obtaining, in a single still-capture image, the continuous absorbance spectra of samples at multiple locations of microsystems. This technique uses an unmodified bright-field microscope, an array of microlenses, and a diffraction grating to disperse the light transmitted by samples of 10- to 500-microm dimensions. By analyzing in a single image the first-order diffracted light, it is possible to collect the full and continuous absorbance spectra of samples at multiple locations (to a spatial resolution of approximately 8 microm) in microwells and microchannels to examine dynamic chemical events (to a time resolution of <10 ms). This article also discusses the optical basis of this method. The simultaneous resolution of wavelength, time, and space at a scale <10 microm provides additional capabilities for chemical and biological analysis.

Light↗

Reagent-loaded cartridges for valveless and automated fluid delivery in microfluidic devices.

An important problem in the life sciences and in health care is simple and rapid detection of biomarkers. Although microfluidic devices are potentially useful in addressing this problem, current techniques for automating fluid delivery--which include valves and electroosmosis--require sophisticated microfabrication of the chip, bulky instrumentation, or both. In this paper, we describe a simple and reliable technique for storing and delivering a sequence of reagents to a microfluidic device. The technique is low-cost, requires minimal user intervention, and can be performed in resource-poor settings (e.g., outside of a laboratory) in the absence of electricity and computer-controlled equipment. In this method, cartridges made of commercially available tubing are filled by sequentially injecting plugs of reagents separated by air spacers. The air spacers prevent the reagents from mixing with each other during cartridge preparation, storage, and usage. As an example, we used this "plug-in cartridge" technology to complete a solid-phase immunoassay in a microchannel in 2 min with low-nanomolar sensitivity and demonstrate the diagnosis of HIV in 13 min.

Acquired Immunodeficiency Syndrome↗

Patterning multiple aligned self-assembled monolayers using light.

This work describes a method for patterning a gold substrate with multiple, aligned self-assembled monolayers (SAMs) using light at different wavelengths. It describes the synthesis and characterization of an alkanethiolate SAM that is photosensitive to light at both 220 and 365 nm. A photomask acts as an area-selective filter for light at 220 and 365 nm, and a single set of exposures at these two wavelengths through one photomask, without steps of alignment between the exposures, can produce three aligned SAMs on one gold substrate. We demonstrate the versatility of this method of photopatterning by modifying individual aligned SAMs chemically to produce surfaces having different properties. We characterize the modified SAMs using immunolabeling, matrix-assisted laser desorption/ionization time-of-flight mass spectroscopy, and surface plasmon resonance spectroscopy. We also describe the patterning of two aligned SAMs that resist the adsorption of proteins and a third region that does not resist the adsorption of proteins. The ability to produce multiple, aligned patterns of SAMs in a single step, without alignment of photomasks in separate steps, increases the versatility of SAMs for studying a range of physical phenomena.

Adsorption↗

Rapid prototyping of 2D structures with feature sizes larger than 8 microm.

This paper extends rapid prototyping for several types of lithography to the 8-25-microm size range, using transparency photomasks prepared by photoplotting. It discusses the technical improvement in photomask quality achieved by photoplotting, compared to the currently used image setting, and demonstrates differences in the resolution that can be obtained with photomasks with features in the 8-100-microm size range. These high-resolution photomasks were used to microfabricate microelectrodes, microlenses, and stamps for microcontact printing, following methods described previously.

Biological Assay↗

Electrokinetic characterization of poly(dimethylsiloxane) microchannels.

This paper characterizes the basic electrokinetic phenomena occurring within native poly(dimethylsiloxane) (PDMS) microchannels. Using simple buffers and current measurements, current density and electroosmosis data were determined in trapezoidal, reversibly sealed PDMS/PDMS and hybrid PDMS/glass channels with a cross-sectional area of 1035.5 microm(2) and about 6 cm length. This data was then compared to that obtained in an air-thermostated 50 microm inner diameter (1963.5 microm(2) cross-sectional area) fused-silica (FS) capillary of 70 cm length. Having a pH 7.8 buffer with an ionic strength (I) of 90 mM, Ohms's law was observed in the microchannels with electric field strengths of up to about 420 V/cm, which is about twice as high as for the FS capillary. The electroosmotic mobility (micro(EO)) in PDMS and FS is shown to exhibit the same general dependences on I and pH. For all configurations tested, the experimentally determined micro(EO) values were found to correlate well with the relationship micro(EO) = a + b log(I), where a and b are coefficients that are determined via nonlinear regression analysis. Electroosmotic fluid pumping in native PDMS also follows a pH dependence that can be estimated with a model based upon the ionization of silanol. Compared to FS, however, the magnitude of the electroosmotic flow in native PDMS is 50-70% smaller over the entire pH range and is difficult to maintain at acidic pH values. Thus, the origin of the negative charge at the inner wall of PDMS, glass, and FS appears to be similar but the density is lower for PDMS than for glass and FS.

Dimethylpolysiloxanes↗

Application of surface biopassivated disposable poly(dimethylsiloxane)/glass chips to a heterogeneous competitive human serum immunoglobulin G immunoassay with incorporated internal standard.

A microfluidic platform for a heterogeneous competitive immunoassay of human immunoglobulin G (IgG) employing Cy5-human IgG as tracer and Cy3-mouse IgG as internal standard was developed. The device consisted of microchannels made of poly(dimethylsiloxane) and glass which were patterned with antibodies against human IgG and mouse IgG. Electrokinetic sample transport was employed in order to exploit the small difference between the net mobilities of analyte and tracer, thereby achieving favorable conditions for the performance of the competitive immunoreaction. The overall quality of the disposable chip and performance of the immunoassay were controlled by monitoring the fluorescence of bound tracer and bound internal standard. Analyses with an insufficient internal standard response were discarded, and immunoassay data evaluation was based on the ratio of tracer and internal standard fluorescence. Using synthetic samples in the range from 0 to 80 microg/mL IgG and alkaline running conditions, a concentration-dependent response with reproducible Cy5/Cy3 signal ratios (average relative standard deviation of 6.8%) was obtained. Chips stored with solution in the channels at 4 degrees C over a two-month period were found to perform like freshly prepared chips, whereas chips stored dry at -20 degrees C and rehydrated prior to use could not be employed. The analysis of patient sera showed that the immunoassay platform behaved differently in the presence of serum-based samples. Using the same conditions as for the synthetic samples, no concentration dependence was noted. With a large excess of tracer, however, an IgG concentration dependence was observed, permitting distinction of samples of patients with normal IgG serum levels (8-16 mg/mL) from those with elevated IgG concentrations (>16 mg/mL).

Animals↗