Search PubMed⌕ Search

Biomedical subjects

Vincent J Cunningham

Publications and source records attributed to Vincent J Cunningham.

18 recordsLinked to original sources

Validation of a tracer kinetic model for the quantification of 5-HT(2A) receptors in human brain with [(11)C]MDL 100,907.

The positron emission tomography (PET) ligand [(11)C]MDL 100,907 has previously been introduced to image the serotonin 2A (5-HT(2A)) receptor in human brain. The aim of this work was to contribute to the verification of the tracer kinetic modelling in human studies. Five healthy volunteers were scanned twice after intravenous bolus injection of approximately 370 MBq [(11)C]MDL 100,907 using dynamic PET. One scan was performed under baseline condition, the other scan commenced 90 mins after a single oral dose of 30 mg of the antidepressant mirtazapine, which binds to the 5-HT(2A) receptor. There did not appear to be radiolabelled metabolites of [(11)C]MDL 100,907 in human plasma, which are likely to cross the blood-brain barrier. Total volumes of distribution VD in 11 different brain regions were estimated using a reversible, two tissue, four rate constants compartment model with a variable fractional blood volume term and the metabolite-corrected plasma input function. There were no significant changes of the VD in the cerebellum between the baseline and the blocked scans confirming the cerebellum as a region devoid of displaceable binding. Regional estimates of binding potential were then obtained indirectly using the cerebellar VD and occupancies calculated. The mean occupancy with this clinically effective dose of mirtazapine was 60% without significant regional differences. This study confirmed the use of an arterial input kinetic model for the quantification of 5-HT(2A) receptor binding with [(11)C]MDL 100,907 and the use of the cerebellum as a reference region for the free and nonspecific binding.

Adult↗

Characterization of the SPECT 5-HT2A receptor ligand 123I-R91150 in healthy volunteers: Part 1--pseudoequilibrium interval and quantification methods.

UNLABELLED: With the aim of characterizing radioiodinated 4-amino-N-1-[3-(4-fluorophenoxy)propyl]-4-methyl-4-piperidinyl]5-iodo-2-methoxybenzamide ((123)I-R91150) as a SPECT ligand for subtype 2A of the 5-hydroxytryptamine receptor (5-HT(2A)), tracer kinetic compartmental analyses were compared with the tissue ratio method (TR). The pseudoequilibrium interval after a single bolus injection was identified, and a reference database of specific uptake ratio (SUR) values was obtained. Within-scan and between-subject variability was also assessed. METHODS: Nineteen healthy men (mean age +/- SD, 24.4 +/- 3.3 y) were included and separated into 2 groups. Dynamic scans with venous blood sampling from 0 to 470 min after a single bolus injection of (123)I-R91150 was completed for 7 of the 9 subjects included in group A, and in one of them compartmental modeling was performed with an arterial blood input function using 1-tissue-compartment (1TC) and 2-tissue-compartment (2TC) models. Binding potential (BP) using the simplified reference tissue model (SRTM) (BP(SRTM)) and SUR values using TR over time were also calculated. The 10 remaining subjects (group B) underwent a single scan at pseudoequilibrium with the aim of improving the precision of mean normal SUR estimates. Regions of interest in cortical regions and basal ganglia for specific uptake, and in cerebellum for nonspecific uptake, were manually drawn on each subject's MR images and translated to the corresponding SPECT slices after coregistration. RESULTS: The 1TC model correlated well with the 2TC model (BP(2TC) = 1.04.BP(1TC) - 0.01, R(2) = 0.98), and both methods correlated with BP(SRTM) and SUR with little bias (BP(1TC) = 1.10 BP(SRTM) + 0.03, R(2) = 0.98; BP(2TC) = 1.15 BP(SRTM) + 0.01, R(2) = 0.98; BP(SRTM) = 0.99 SUR(mean) + 0.01, R(2) = 0.98). SUR values stabilized from 180 min after injection in most cortical regions, ranging from 0.51 +/- 0.10 in the orbitofrontal region to 0.27 +/- 0.09 in the parietal region. Within-scan and between-subject variability among regions ranged from 10% to 14.8%, and from 18.3% to 35.4%, respectively. CONCLUSION: (123)I-R91150 distribution agrees with autoradiography results, showing highly specific binding in cortical regions. The correlations found among 1TC, 2TC, SRTM, and TR outcome measurements support the use of TR for quantification of 5-HT(2A) receptor binding with (123)I-R91150 SPECT and a simple protocol avoiding arterial blood sampling and serial scanning over time.

Adult↗

Characterization of the SPECT 5-HT2A receptor ligand 123I-R91150 in healthy volunteers: part 2--ketanserin displacement.

UNLABELLED: As part of the radioiodinated 4-amino-N-1-[3-(4-fluorophenoxy)propyl]-4-methyl-4-piperidinyl]5-iodo-2-methoxybenzamide ((123)I-R91150) characterization study, ketanserin challenges were performed on healthy volunteers with the aim of assessing the specificity of (123)I-R91150 binding to subtype 2A of the 5-hydroxytryptamine receptor (5-HT(2A)), the sensitivity of (123)I-R91150 SPECT in measuring ligand displacement, the relationship between ketanserin plasma concentrations and (123)I-R91150 displacement, and the suitability of the cerebellum as a reference region for quantification. METHODS: Dynamic SPECT was performed on 6 healthy men (mean age +/- SD, 21 +/- 0.89 y) from the time of (123)I-R91150 injection until 470 min afterward. Ketanserin was administered intravenously at 210 min after injection at 3 doses: 0.1 mg/kg (n = 2), 0.05 mg/kg (n = 2), and 0.015 mg/kg (n = 2). Blood samples for measurement of ketanserin plasma concentrations were drawn. MRI was performed on all subjects and coregistered to the SPECT data for region-of-interest drawing on cortical regions and cerebellum. The simplified reference tissue model (SRTM) was considered the gold standard for quantification, and results were compared with those obtained with the tissue ratio method (TR). The percentage (123)I-R91150 displacement was calculated with both methods as the percentage difference between baseline and postketanserin scans. RESULTS: Depending on the cerebral regions with the maximum ketanserin dose studied, SRTM and TR mean displacements were 57.1%-95.4% and 71.9%-101.2%, respectively, for the 0.1 mg/kg dose; 51.7%-91.4% and 56.7%-102.8%, respectively, for the 0.05 mg/kg dose; and 7.7%-54.5% and 13.8%-47.0%, respectively, for the lowest dose, 0.015 mg/kg. A good correlation was found between the 2 methods. No ketanserin-induced displacement was observed in the cerebellum time-activity curves, supporting the use of the cerebellum as a reference region. The relationship between displacement and ketanserin plasma concentration fit with a rectangular hyperbola, with a 5.6 ng/mL concentration associated with 50% of the maximum displacement (EC(50)). EC(50) values calculated using occupancies derived both with SRTM and with TR were in good agreement. CONCLUSION: (123)I-R91150 SPECT is sensitive enough to measure ketanserin dose-dependent displacement in cerebral regions rich in 5-HT(2A) receptors. These results support the selectivity of (123)I-R91150 for 5-HT(2A) receptors and its use as a SPECT ligand for measurements of drug-induced 5-HT(2A) receptor occupancy in humans.

Adult↗

Behaviour of [11C]R(-)- and [11C]S(+)-rolipram in vitro and in vivo, and their use as PET radiotracers for the quantificative assay of PDE4.

Cyclic AMP (cAMP) is a continually produced nucleotide which is inactivated by hydrolysis to 5'AMP via phosphodiesterase 4 (PDE4) enzymes. Rolipram is a selective PDE4 inhibitor which exists in two enantiomeric forms, R(-) and S(+). Both of these enantiomers have previously been labelled with carbon-11 and used as positron emission tomography (PET) ligands for measuring PDE4 expression and function, and indirectly to explore the function of the cAMP second messenger, in vivo, using PET. The aim of these studies was to relate the in vitro affinities of the two rolipram enantiomers using standard pharmacological assays with the in vivo behaviour of the two enantiomers using PET. In vitro competition assays were performed using rat cortical membranes and [(3)H]R(-)- and [(3)H]S(+)-rolipram with increasing concentrations of either unlabelled R(-)- or S(+)-rolipram. In vivo, a series of PET studies were performed in the porcine brain using [(11)C]R(-)-rolipram with co-administration of increasing doses of either unlabelled R(-)- or S(+)-rolipram. Additional in vivo PET studies were performed using [(11)C]S(+)-rolipram with saturating doses of rolipram. In all studies, R(-)-rolipram exhibited a higher affinity for the PDE4 enzyme than S(+)-rolipram. The calculated affinity ratios were 7.97 from the in vitro studies; 12.5 from the in vivo studies using [(11)C]R(-)-rolipram; and 14.7 from the in vivo studies using [(11)C]S(+)-rolipram. To conclude, the in vitro affinities of R(-)- and S(+)-rolipram predict their apparent in vivo behaviour in the porcine brain, as measured by PET.

3',5'-Cyclic-AMP Phosphodiesterases↗

Parametrically defined cerebral blood vessels as non-invasive blood input functions for brain PET studies.

A non-invasive alternative to arterial blood sampling for the generation of a blood input function for brain positron emission tomography (PET) studies is presented. The method aims to extract the dimensions of the blood vessel directly from PET images and to simultaneously correct the radioactivity concentration for partial volume and spillover. This involves simulation of the tomographic imaging process to generate images of different blood vessel and background geometries and selecting the one that best fits, in a least-squares sense, the acquired PET image. A phantom experiment was conducted to validate the method which was then applied to eight subjects injected with 6-[18F]fluoro-L-DOPA and one subject injected with [11C]CO-labelled red blood cells. In the phantom study, the diameter of syringes filled with an 11C solution and inserted into a water-filled cylinder were estimated with an accuracy of half a pixel (1 mm). The radioactivity concentration was recovered to 100 +/- 4% in the 8.7 mm diameter syringe, the one that most closely approximated the superior sagittal sinus. In the human studies, the method systematically overestimated the calibre of the superior sagittal sinus by 2-3 mm compared to measurements made in magnetic resonance venograms on the same subjects. Sources of discrepancies related to the anatomy of the blood vessel were found not to be fundamental limitations to the applicability of the method to human subjects. This method has the potential to provide accurate quantification of blood radioactivity concentration from PET images without the need for blood samples, corrections for delay and dispersion, co-registered anatomical images, or manually defined regions of interest.

Adult↗

On the logic of hypothesis testing in functional imaging.

Statistics is nowadays the customary language of functional imaging. It is common to express an experimental setting as a set of null hypotheses over complex models and to present results as maps of p-values derived from sophisticated probability distributions. However, the growing interest in the development of advanced statistical algorithms is not always paralleled by similar attention to how these techniques may regiment the ways in which users draw inferences from their data. This article investigates the logical bases of current statistical approaches in functional imaging and probes their suitability to inductive inference in neuroscience. The frequentist approach to statistical inference is reviewed with attention to its two main constituents: Fisherian "significance testing" and Neyman-Pearson "hypothesis testing". It is shown that these conceptual systems, which are similar in the univariate testing case, dissociate into two quite different methods of inference when applied to the multiple testing problem, the typical framework of functional imaging. This difference is explained with reference to specific issues, like small volume correction, which are most likely to generate confusion in the practitioner. Further insight into this problem is achieved by recasting the multiple comparison problem into a multivariate Bayesian formulation. This formulation introduces a new perspective where the inferential process is more clearly defined in two distinct steps. The first one, inductive in form, uses exploratory techniques to acquire preliminary notions on the spatial patterns and the signal and noise characteristics. The (smaller) set of likely spatial patterns generated is then tested with newer data and a more rigorous multiple hypothesis testing technique (deductive step).

Algorithms↗

A bolus/infusion paradigm for the novel NMDA receptor SPET tracer [123I]CNS 1261.

We have previously performed quantitative kinetic modeling of [(123)I]CNS 1261, a new SPET ligand for the MK801 intrachannel site of the NMDA receptor. We now report a bolus-infusion protocol, which eliminates the need for arterial blood sampling. Dynamic SPET scanning and venous blood sampling were performed in 7 healthy volunteers. Good agreement was obtained between kinetic and equilibrium analysis. SPET scanning with a bolus-infusion protocol is a valid method to estimate the total volume of distribution for [(123)I]CNS 1261 in clinical populations.

Adult↗

Rank-shaping regularization of exponential spectral analysis for application to functional parametric mapping.

Compartmental models are widely used for the mathematical modelling of dynamic studies acquired with positron emission tomography (PET). The numerical problem involves the estimation of a sum of decaying real exponentials convolved with an input function. In exponential spectral analysis (SA), the nonlinear estimation of the exponential functions is replaced by the linear estimation of the coefficients of a predefined set of exponential basis functions. This set-up guarantees fast estimation and attainment of the global optimum. SA, however, is hampered by high sensitivity to noise and, because of the positivity constraints implemented in the algorithm, cannot be extended to reference region modelling. In this paper, SA limitations are addressed by a new rank-shaping (RS) estimator that defines an appropriate regularization over an unconstrained least-squares solution obtained through singular value decomposition of the exponential base. Shrinkage parameters are conditioned on the expected signal-to-noise ratio. Through application to simulated and real datasets, it is shown that RS ameliorates and extends SA properties in the case of the production of functional parametric maps from PET studies.

Algorithms↗

Kinetic modelling of [123I]CNS 1261--a potential SPET tracer for the NMDA receptor.

N-(1-napthyl)-N'-(3-[(123)I]-iodophenyl)-N-methylguanidine ([(123)I]CNS 1261) is a novel SPET ligand developed for imaging the NMDA receptor intra-channel MK 801/PCP/ketamine site. Data was acquired in 7 healthy volunteers after bolus injection of [(123)I]CNS 1261. Kinetic modeling showed reversible tracer binding. Arterial and venous time-activity curves overlapped after 90 min. The rank order of binding was: Thalamus > striatum > cortical regions > white matter. This distribution concurs with [(11)C]-ketamine and [(18)F]-memantine PET studies. These data provide a methodological basis for further direct in vivo challenge studies.

Adult↗

Analysis of D2 dopamine receptor occupancy with quantitative SPET using the high-affinity ligand [123I]epidepride: resolving conflicting findings.

Recent studies of limbic cortical dopamine D(2) receptor occupancy by clozapine using high-affinity PET and SPET radioligands have produced conflicting findings. It has been suggested that these divergent findings are due to between-study differences in the method used to estimate D(2) receptor-binding potential. We compared different methods for estimating striatal and temporal cortical D(2) receptor occupancy with high-affinity tracers. In vivo experimental SPET data, obtained with [(123)I]epidepride were analysed with reference tissue kinetic modeling and with the ratio method, applied to data corresponding to short (60 min) and long (240 min) acquisition times. Dopamine D(2) receptor occupancy by the atypical antipsychotic drug risperidone was evaluated. Simulation experiments were also performed, comparing occupancy values obtained for different receptor densities in relation to different data acquisition times. The simulation results revealed that previously published data regarding errors in occupancy estimation by analysis of time activity data acquired for 60 min cannot be extrapolated to studies performed over 240 min. The ratio method provided accurate temporal cortical D(2) receptor occupancy values when applied to data from a late time period, but underestimated the occupancy with earlier data. In striatum, both the late data ratio method and reference tissue kinetic modeling using all data underestimated D(2) receptor occupancy. However, more accurate analyses of striatal D(2) occupancy still showed selective limbic/cortical occupancy by risperidone. Our results substantiate the previous [(123)I]epidepride findings of high temporal cortical occupancy by other atypical antipsychotic drugs and suggest that a potential source of conflicting findings might be short scanning times imposed by [(11)C]FLB 457, leading to underestimation of temporal cortical D(2) receptor occupancy by this method.

Algorithms↗

On the undecidability among kinetic models: from model selection to model averaging.

This article deals with the problem of model selection for the mathematical description of tracer kinetics in nuclear medicine. It stems from the consideration of some specific data sets where different models have similar performances. In these situations, it is shown that considerate averaging of a parameter's estimates over the entire model set is better than obtaining the estimates from one model only. Furthermore, it is also shown that the procedure of averaging over a small number of "good" models reduces the "generalization error," the error introduced when the model selected over a particular data set is applied to different conditions, such as subject populations with altered physiologic parameters, modified acquisition protocols, and different signal-to-noise ratios. The method of averaging over the entire model set uses Akaike coefficients as measures of an individual model's likelihood. To facilitate the understanding of these statistical tools, the authors provide an introduction to model selection criteria and a short technical treatment of Akaike's information-theoretic approach. The new method is illustrated and epitomized by a case example on the modeling of [11C]flumazenil kinetics in the brain, containing both real and simulated data.

Carbon Radioisotopes↗

A linear wavelet filter for parametric imaging with dynamic PET.

This paper describes a new filter for parametric images obtained from dynamic positron emission tomography (PET) studies. The filter is based on the wavelet transform following the heuristics of a previously published method that are here developed into a rigorous theoretical framework. It is shown that the space-time problem of modeling a dynamic PET sequence reduces to the classical one of estimation of a normal multivariate vector of independent wavelet coefficients that, under least-squares risk, can be solved by straightforward application of well established theory. From the study of the distribution of wavelet coefficients of PET images, it is inferred that a James-Stein linear estimator is more suitable for the problem than traditional nonlinear procedures that are incorporated in standard wavelet filters. This is confirmed by the superior performance of the James-Stein filter in simulation studies compared to a state-of-the-art nonlinear wavelet filter and a nonstationary filter selected from literature. Finally, the formal framework is interpreted for the practitioner's point of view and advantages and limitations of the method are discussed.

Aged↗

In vivo metabolism and partitioning of 6-[18F]fluoro-L-meta-tyrosine in whole blood: a unified compartment model.

Physiological quantification of dynamic PET data requires the determination of an input function, preferably from plasma. A compartmental model relating a parent radiotracer, its radiolabelled metabolites and their exchange between plasma and erythrocytes is presented. This model allows for the time course of radioactivity measured in whole blood to be transformed into the time course of the radiotracer in plasma. The utility of this approach is illustrated with blood data collected on 30 human subjects injected with 6-[18F]fluoro-L-meta-tyrosine (FmT), a pre-synaptic dopaminergic radiotracer. A three-compartment four-parameter model is shown to yield significantly better fits to the blood data than related lower and higher order models. This model is found to be robust to measurement noise, and yet sensitive to metabolic changes induced by pretreatment with carbidopa. For FmT, the between-subject variations are shown to be small enough to warrant the use of a population-based correction; tissue time-activity curves were simulated to verify that this correction does not significantly affect the precision and accuracy of the derived rate constants. The unified blood model can be adapted for radiotracers other than FmT as long as the blood partition ratio of the parent radiotracer differs from that of its metabolites and/or the rate at which they equilibrate between plasma and erythrocytes is different.

Adult↗

Implementation and application of a brain template for multiple volumes of interest.

We present a region template and a protocol for transforming that template to define anatomical volumes of interest (VOIs) in the human brain without operator intervention, based on software contained in the SPM99 package (Statistical Parametric Mapping, Wellcome Department of Cognitive Neurology, London, UK). We used an MRI of a reference brain to create an anatomical template of 41 VOIs, covering the entire brain, that can be spatially transformed to fit individual brain scans. Modified software allows for the reslicing and adaptation of the transformed template to any type of coregistered functional data. Individually defined VOIs can be added. We present an assessment of the necessary spatial transformations and compare results obtained for scans acquired in two different orientations. To evaluate the spatial transformations, 11 landmarks distributed throughout the brain were chosen. Euclidean distances between repeat samples at each landmark were averaged across all landmarks to give a mean difference of 1.3 plus minus 1.0 mm. Average Euclidean distances between landmarks (MRI:transformed template) were 8.1 plus minus 3.7 mm in anterior-posterior commissure (ACPC) and 7.6 plus minus 3.7 mm in temporal lobe (TL) orientation. In this study, we use [(11)C]-flumazenil-(FMZ-)PET as an example for the application of the region template. Thirty-four healthy volunteers were scanned, 21 in standard ACPC orientation, 13 in TL orientation. All had high resolution MRI and FMZ-PET. The average coefficient of variation (CV) of FMZ binding for cortical regions was 0.15, comparable with CVs from manually defined VOIs. FMZ binding was significantly different in 6/19 anatomical areas in the control groups obtained in the different orientations, probably due to anisotropic voxel dimensions. This new template allows for the reliable and fast definition of multiple VOIs. It can be used for different imaging modalities and in different orientations. It is necessary that imaging data for groups compared are acquired in the same orientation.

Adult↗

Imaging the GABA-benzodiazepine receptor subtype containing the alpha5-subunit in vivo with [11C]Ro15 4513 positron emission tomography.

There is evidence of marked variation in the brain distribution of specific subtypes of the GABA-benzodiazepine receptor and that particular subtypes mediate different functions. The alpha5-containing subtype is highly expressed in the hippocampus, and selective alpha5 inverse agonists (which decrease tonic GABA inhibition) are being developed as potential memory-enhancing agents. Evidence for such receptor localization and specialization in humans in vivo is lacking because the widely used probes for imaging the GABA-benzodiazepine receptors, [11C]flumazenil and [123I]iomazenil, appear to reflect binding to the alpha1 subtype, based on its distribution and affinity of flumazenil for this subtype. The authors characterized for positron emission tomography (PET) a radioligand from Ro15 4513, the binding of which has a marked limbic distribution in the rat and human brain in vivo. Competition studies in vivo in the rat revealed that radiolabeled Ro15 4513 uptake was reduced to nonspecific levels only by drugs that have affinity for the alpha5 subtype (flunitrazepam, RY80, Ro15 4513, L655,708), but not by the alpha1 selective agonist, zolpidem. Quantification of [11C]Ro15 4513 PET was performed in humans using a metabolite-corrected plasma input function. [11C]Ro15 4513 uptake was relatively greater in limbic areas compared with [11C]flumazenil, but lower in the occipital cortex and cerebellum. The authors conclude that [11C]Ro15 4513 PET labels in vivo the GABA-benzodiazepine receptor containing the alpha5 subtype in limbic structures and can be used to further explore the functional role of this subtype in humans.

Animals↗

Positron emission tomography partial volume correction: estimation and algorithms.

Partial volume effects in positron emission tomography (PET) lead to quantitative under- and over-estimations of the regional concentrations of radioactivity in reconstructed images and corresponding errors in derived functional or parametric images. The limited resolution of PET leads to "tissue-fraction" effects, reflecting underlying tissue heterogeneity, and "spillover" effects between regions. Addressing the former problem in general requires supplementary data, for example, coregistered high-resolution magnetic resonance images, whereas the latter effect can be corrected for with PET data alone if the point-spread function of the tomograph has been characterized. Analysis of otherwise homogeneous region-of-interest data ideally requires a combination of tissue classification and correction for the point-spread function. The formulation of appropriate algorithms for partial volume correction (PVC) is dependent on both the distribution of the signal and the distribution of the underlying noise. A mathematical framework has therefore been developed to accommodate both of these factors and to facilitate the development of new PVC algorithms based on the description of the problem. Several methodologies and algorithms have been proposed and implemented in the literature in order to address these problems. These methods do not, however, explicitly consider the noise model while differing in their underlying assumptions. The general theory for estimation of regional concentrations, associated error estimation, and inhomogeneity tests are presented in a weighted least squares framework. The analysis has been validated using both simulated and real PET data sets. The relations between the current algorithms and those published previously are formulated and compared. The incorporation of tensors into the formulation of the problem has led to the construction of computationally rapid algorithms taking into account both tissue-fraction and spillover effects. The suitability of their application to dynamic and static images is discussed.

Algorithms↗

Positron emission tomography compartmental models: a basis pursuit strategy for kinetic modeling.

A kinetic modeling approach for the quantification of in vivo tracer studies with dynamic positron emission tomography (PET) is presented. The approach is based on a general compartmental description of the tracer's fate in vivo and determines a parsimonious model consistent with the measured data. The technique involves the determination of a sparse selection of kinetic basis functions from an overcomplete dictionary using the method of basis pursuit denoising. This enables the characterization of the systems impulse response function from which values of the systems macro parameters can be estimated. These parameter estimates can be obtained from a region of interest analysis or as parametric images from a voxel-based analysis. In addition, model order estimates are returned that correspond to the number of compartments in the estimated compartmental model. Validation studies evaluate the methods performance against two preexisting data led techniques, namely, graphical analysis and spectral analysis. Application of this technique to measured PET data is demonstrated using [11C]diprenorphine (opiate receptor) and [11C]WAY-100635 (5-HT1A receptor). Although the method is presented in the context of PET neuroreceptor binding studies, it has general applicability to the quantification of PET/SPECT radiotracer studies in neurology, oncology, and cardiology.

Artifacts↗