Search PubMed⌕ Search

Biomedical subjects

Vincent Dousset

Publications and source records attributed to Vincent Dousset.

6 recordsLinked to original sources

Diffusion-weighted MR imaging with apparent diffusion coefficient and apparent diffusion tensor maps in cervical spondylotic myelopathy.

PURPOSE: To evaluate diffusion-weighted magnetic resonance (MR) imaging in patients with cervical spondylosis and/or myelopathy. MATERIALS AND METHODS: A multishot echo-planar imaging sequence with calculation of apparent diffusion coefficient (ADC) and apparent diffusion tensor (ADT) was applied in 36 patients with symptomatic cervical spondylosis. Diffusion-weighted images read by two neuroradiologists were compared with T2-weighted fast spin-echo images read independently by three neuroradiologists with regard to clinical status (n = 36). MR findings in a selected subgroup of 20 patients whose clinical status was confirmed by electrophysiologic examination also were compared. Sensitivity, specificity, positive predictive value, and negative predictive value of both T2-weighted imaging and diffusion-weighted imaging (ADC and ADT) were calculated and compared. RESULTS: Patients with myelopathy had abnormal ADC (17 of 21) and ADT (15 of 19) maps with increased ADC and ADT values and decreased anisotropy. For the detection of myelopathy, diffusion-weighted ADC maps had a sensitivity of 80% (17 of 21), while T2-weighted images had a sensitivity of 61% (13 of 21). The negative predictive value was 63% (seven of 11) and 60% (12 of 20) for ADC maps and T2-weighted images, respectively. Conversely, the specificity of diffusion-weighted images (53%; seven of 13) was lower than that of T2-weighted images (92%; 12 of 13). In patients with myelopathy confirmed at electrophysiologic examination, the sensitivity of diffusion-weighted images increased to 92% (12 of 13) and the negative predictive value increased to 75% (three of four), while T2-weighted images had a 53% (seven of 13) sensitivity and a 50% (six of 12) negative predictive value. CONCLUSION: Diffusion weighting improved the sensitivity of imaging in cervical spondylotic myelopathy.

Adult↗

Intraosseous lidocaine provides effective analgesia for percutaneous vertebroplasty of osteoporotic fractures.

PURPOSE: To assess the safety and efficacy of intraosseous lidocaine (IL), in comparison with iv nalbuphine and propacetamol (NP) for analgesia during percutaneous vertebroplasty (PV) in order to avoid general anesthesia in elderly patients. METHODS: Patients (age 68 +/- 13 yr, weight 66 +/- 6 kg) undergoing PV for osteoporotic fractures were randomized prospectively into two groups: NP (n=50) and IL (n=50). All patients were premedicated (oral hydroxyzine 1 mg.kg(-1)) and had skin infiltration with 5 mL of 1% lidocaine prior to vertebral puncture. Thirty minutes before the procedure, Group NP received, in a blinded manner, 50 mL of iv nalbuphine (0.3 mg.kg(-1)) and propacetamol (30 mg.kg(-1)) while Group IL received 50 mL of iv saline. During vertebral puncture, Groups NP and IL received, in a blinded manner, 1 mL.10 kg(-1) of intraosseous saline and 1% lidocaine respectively. Pain was assessed during vertebral puncture and cement injection with a four-point verbal rating scale. Additionally, lidocaine plasma kinetics were obtained in 11 IL patients. RESULTS: Analgesic efficacy was similar in the IL and NP groups (85 vs 84%). Group NP had more side effects. Lidocaine peak recorded concentration was 2.6 +/- 0.1 microg.mL(-1) i.e., about three times less than the reported toxic limits. CONCLUSION: IL is as effective as the association of iv NP for analgesia in PV. However, considering that both protocols were insufficient in about 15% of cases, other modalities are needed to further improve analgesia and avoid general anesthesia during vertebroplasty.

Adult↗

Lack of agreement between direct magnetic resonance imaging and statistical determination of a subthalamic target: the role of electrophysiological guidance.

OBJECT: The goal of this study was to determine the most suitable procedure(s) to localize the optimal site for high-frequency stimulation of the subthalamic nucleus (STN) for the treatment of advanced Parkinson disease. METHODS: Stereotactic coordinates of the STN were determined in 14 patients by using three different methods: direct identification of the STN on coronal and axial T2-weighted magnetic resonance (MR) images and indirect targeting in which the STN coordinates are referred to the anterior commissure-posterior commissure (AC-PC) line, which, itself, is determined either by using stereotactic ventriculography or reconstruction from three-dimensional (3D) MR images. During the surgical procedure, electrode implantation was guided by single-unit microrecordings on multiple parallel trajectories and by clinical assessment of stimulations. The site where the optimal functional response was obtained was considered to be the best target. Computerized tomography scanning was performed 3 days later and the scans were combined with preoperative 3D MR images to transfer the position of the best target to the same system of stereotactic coordinates. An algorithm was designed to convert individual stereotactic coordinates into an all-purpose PC-referenced system for comparing the respective accuracy of each method of targeting, according to the position of the best target. CONCLUSIONS: The target that is directly identified by MR imaging is more remote (mainly in the lateral axis) from the site of the optimal functional response than targets obtained using other procedures, and the variability of this method in the lateral and superoinferior axes is greater. In contrast, the target defined by 3D MR imaging is closest to the target of optimal functional response and the variability of this method is the least great. Thus, 3D reconstruction adjusted to the AC-PC line is the most accurate technique for STN targeting, whereas direct visualization of the STN on MR images is the least effective. Electrophysiological guidance makes it possible to correct the inherent inaccuracy of the imaging and surgical techniques and is not designed to modify the initial targeting.

Adult↗

Iron particle labeling of haematopoietic progenitor cells: an in vitro study.

We present a method for labeling bone marrow haematopoietic progenitor cells with iron particles. Labeling was assessed by magnetic resonance imaging and electron microscopy. Labeling with iron particles could allow the following by imaging techniques of haematopoietic cells in physiologic and pathologic conditions such as the engraftment of haematopoietic progenitor cells or the migration of myelomonocytic cells in inflammatory diseases.

Animals↗