Search PubMed⌕ Search

Biomedical subjects

Victor M Ugaz

Publications and source records attributed to Victor M Ugaz.

18 recordsLinked to original sources

Development of a miniature calorimeter for identification and detection of explosives and other energetic compounds.

The development of versatile systems capable of providing rapid, portable, and inexpensive detection of explosives and energetic compounds are critically needed to offer enhanced levels of protection against current and future threats to homeland security, as well as satisfying a wide range of applications in the fields of forensic analysis, emergency response, and industrial hazards analysis. Calorimetric techniques have been largely overlooked in efforts to develop advanced chemical analysis technology, largely because of limitations associated with the physical size of the instruments and the relatively long timescales (>30 min) required to obtain a result. This miniaturized calorimeter circumvents these limitations, thereby creating a first-of-its-kind system allowing thermal analysis to be performed in a portable format that can be configured for use in a variety of field operations with a significantly reduced response time (approximately 2 min). Unlike current explosives detectors, this system is based on calorimetric techniques that are inherently capable of providing direct measurements of energy release potential and therefore do not depend on prior knowledge of familiar compounds.

Calorimetry↗

Multivortex micromixing.

The ability to mix liquids in microchannel networks is fundamentally important in the design of nearly every miniaturized chemical and biochemical analysis system. Here, we show that enhanced micromixing can be achieved in topologically simple and easily fabricated planar 2D microchannels by simply introducing curvature and changes in width in a prescribed manner. This goal is accomplished by harnessing a synergistic combination of (i) Dean vortices that arise in the vertical plane of curved channels as a consequence of an interplay between inertial, centrifugal, and viscous effects, and (ii) expansion vortices that arise in the horizontal plane due to an abrupt increase in a conduit's cross-sectional area. We characterize these effects by using confocal microscopy of aqueous fluorescent dye streams and by observing binding interactions between an intercalating dye and double-stranded DNA. These mixing approaches are versatile and scalable and can be straightforwardly integrated as generic components in a variety of lab-on-a-chip systems.

Animals↗

Collection, focusing, and metering of DNA in microchannels using addressable electrode arrays for portable low-power bioanalysis.

Although advances in microfluidic technology have enabled increasingly sophisticated biosensing and bioassay operations to be performed at the microscale, many of these applications employ such small amounts of charged biomolecules (DNA, proteins, and peptides) that they must first be preconcentrated to a detectable level. Efficient strategies for precisely handling minute quantities of biomolecules in microchannel geometries are critically needed; however, it has proven challenging to achieve simultaneous concentration, focusing, and metering capabilities with current-generation sample-injection technology. By using microfluidic chips incorporating arrays of individually addressable microfabricated electrodes, we demonstrate that DNA can be sequentially concentrated, focused into a narrow zone, metered, and injected into an analysis channel. This technique transports charged biomolecules between active electrodes upon application of a small potential difference (1 V) and is capable of achieving orders of magnitude concentration increases within a small device footprint. The collected samples are highly focused, with sample zone size and shape defined solely by electrode geometry.

DNA↗

Separation performance of single-stranded DNA electrophoresis in photopolymerized cross-linked polyacrylamide gels.

Considerable effort has been directed toward optimizing performance and maximizing throughput in ssDNA electrophoresis because it is a critical analytical step in a variety of genomic assays. Ultimately, it would be desirable to quantitatively determine the achievable level of separation resolution directly from measurements of fundamental physical properties associated with the gel matrix rather than by the trial and error process often employed. Unfortunately, this predictive capability is currently lacking, due in large part to the need for a more detailed understanding of the fundamental parameters governing separation performance (mobility, diffusion, and dispersion). We seek to address this issue by systematically characterizing electrophoretic mobility, diffusion, and dispersion behavior of ssDNA fragments in the 70-1,000 base range in a photopolymerized cross-linked polyacrylamide matrix using a slab gel DNA sequencer. Data are collected for gel concentrations of 6, 9, and 12%T at electric fields ranging from 15 to 40 V/cm, and resolution predictions are compared with corresponding experimentally measured values. The data exhibit a transition from behavior consistent with the Ogston model for small fragments to behavior in agreement with the biased reptation model at larger fragment sizes. Mobility data are also used to estimate the mean gel pore size and compare the predictions of several models.

Acrylic Resins↗

An inexpensive microslab gel DNA electrophoresis system with real-time fluorescence detection.

In this paper, we describe the construction of a simple yet powerful gel electrophoresis apparatus that can be used to perform size-selective separations of DNA fragments in virtually any laboratory. This system employs a microslab gel format with a novel gel casting technique that eliminates the need for delicate combs to define sample loading wells. The compact size of the microslab gel format allows rapid separations to be performed at low voltages using submicroliter sample volumes. Real time fluorescence detection of the migrating DNA fragments is accomplished using an inexpensive digital microscope that directly connects to any PC with a USB interface. The microscope is readily adaptable for this application by replacing its white light source with a blue light-emitting diode (LED) and adding an appropriate emission filter. Both polyacrylamide and agarose gels can be used as separation matrices. Separation performance was characterized using standard dsDNA ladders, and correct sizing of a 191 bp PCR product was achieved in 15 min. The low cost and simplicity of this system makes it ideally suited for use in a variety of laboratory and educational settings.

DNA↗

Using in situ rheology to characterize the microstructure in photopolymerized polyacrylamide gels for DNA electrophoresis.

Photopolymerized cross-linked polyacrylamide hydrogels are attractive sieving matrix formulations for DNA electrophoresis owing to their rapid polymerization times and the potential to locally tailor the gel pore structure through spatial variation of illumination intensity. This capability is especially important in microfluidic systems, where photopolymerization allows gel matrices to be precisely positioned within complex microchannel networks. Separation performance is also directly related to the nanoscale gel pore structure, which is in turn strongly influenced by polymerization kinetics. Unfortunately, detailed studies of the interplay among polymerization kinetics, mechanical properties, and structural morphology are lacking in photopolymerized hydrogel systems. In this paper, we address this issue by performing a series of in situ dynamic small-amplitude oscillatory shear measurements during photopolymerization of cross-linked polyacrylamide electrophoresis gels to investigate the relationship between rheology and parameters associated with the gelation environment including UV intensity, monomer and cross-linker composition, and reaction temperature. In general, we find that the storage modulus G' increases with increasing initial monomer concentration, cross-linker concentration, and polymerization temperature. The steady-state value of G', however, exhibits a more complex dependence on UV intensity that varies with gel concentration. A simple model based on rubber elasticity theory is used to obtain estimates of the average gel pore size that are in surprisingly good agreement with corresponding data obtained from analysis of DNA electrophoretic mobility in gels cast under identical polymerization conditions.

Acrylic Resins↗

Polymerase chain reaction in miniaturized systems: big progress in little devices.

A critical need exists for advanced technologies that enable genomic-based DNA analysis to be performed with significantly higher throughput and at a significantly lower cost than is attainable with current hardware. Miniaturized polymerase chain reaction systems offer an attractive platform to address these needs, combining the ability to perform rapid thermocycling with a portable device format that can be inexpensively mass produced. We review recent efforts aimed at developing these next-generation systems and discuss some of the practical considerations involved in adapting this technology for routine laboratory use.

Electrophoresis, Microchip↗

DNA mutation detection and analysis using miniaturized microfluidic systems.

Identification of genetic sequence variations occurring on a population-wide scale is key to unraveling the complex interactions that are the underlying cause of many medical disorders and diseases. A critical need exists, however, for advanced technology to enable DNA mutation analysis to be performed with significantly higher throughput and at significantly lower cost than is currently attainable. Microfluidic systems offer an attractive platform to address these needs by combining the ability to perform rapid analysis with a simplified device format that can be inexpensively mass-produced. This paper will review recent progress toward developing these next-generation systems and discuss challenges associated with adapting these technologies for routine laboratory use.

DNA Mutational Analysis↗

Fluid mixing in planar spiral microchannels.

Mixing of fluids at the microscale poses a variety of challenges, many of which arise from the fact that molecular diffusion is the dominant transport mechanism in the laminar flow regime. While considerable progress has been made toward developing strategies to achieve improved mixing in microfluidic systems, many of these techniques introduce additional complexity to device fabrication and/or operation processes. In this work, we explore the use of compact spiral-shaped flow geometries designed to achieve efficient mixing in a format that can be constructed using a single planar soft lithography step without the need for multilayer alignment. A series of 150 microm-wide by 29 microm-tall channels were constructed, each of which incorporated a series of spiral shaped sections arrayed along the flow path. Five spiral designs with varying channel lengths were investigated, and mixing studies were carried out at flow rates corresponding to Reynolds numbers ranging from 0.02 to 18.6. Under appropriate conditions, transverse Dean flows are induced that augment diffusive transport and promote enhanced mixing in considerably shorter downstream distances as compared with conventional planar straight channel designs. Mixing efficiency can be further enhanced by incorporating expansion vortex effects via abrupt changes in cross-sectional area along the flow path.

Equipment Design↗

Thermoplastic elastomer gels: an advanced substrate for microfluidic chemical analysis systems.

We demonstrate the use of thermoplastic elastomer gels as advanced substrates for construction of complex microfluidic networks suitable for use in miniaturized chemical analysis systems. These gels are synthesized by combining inexpensive polystyrene-(polyethylene/polybutylene)-polystyrene triblock copolymers with a hydrocarbon extender oil for which the ethylene/butylene midblocks are selectively miscible. The insoluble styrene end blocks phase separate into localized nanodomains, resulting in the formation of an optically transparent, viscoelastic, and biocompatible gel network that is melt-processable at temperatures in the vicinity of 100 degrees C. This unique combination of properties allows microfluidic channels to be fabricated in a matter of minutes by simply making impressions of the negative relief structures on heated master molds. Melt processability allows multiple impressions to be made against different masters to construct complex geometries incorporating multi-height features within the same microchannel. Intricate interconnected multilayered structures are also easily fabricated owing to the ability to bond and seal multiple layers by briefly heating the material at the bond interface. Thermal and mechanical properties are tunable over a wide range through proper selection of gel composition.

Biocompatible Materials↗

Reactions and fluidics in miniaturized natural convection systems.

Buoyancy-driven convection offers a novel and greatly simplified mechanism for generating continuous nonpulsatile flow fields and performing thermally activated biochemical reactions. In this paper, we build on our previous work by constructing a multiwell device incorporating an array of 35-microL cylindrical cavities to perform polymerase chain reaction (PCR) amplification of a 191-base pair fragment associated with membrane channel proteins M1 and M2 of the influenza-A virus in as little as 15 min with performance comparable to conventional thermocyclers. We also describe entirely new adaptations of convective flows by conducting a series of coordinated flow visualization and computational studies to explore the design of closed-loop systems to execute tunable thermocycling, pumping, and mixing operations in a format suitable for integration into miniaturized biochemical analysis systems. Using 15-microL convective flow loops, we are able to perform PCR amplification of the same 191-base pair fragment associated with the influenza-A virus, as well as a 295-base pair segment of the human beta-actin gene in a format offering an enhanced degree of control and tunability. These convective flow devices can be further scaled down to nanoliter volumes and are ideally suited as a platform for a new generation of low-power, portable microfluidic DNA analysis systems.

Actins↗

Printed circuit technology for fabrication of plastic-based microfluidic devices.

One of the primary advantages of using plastic-based substrates for microfluidic systems is the ease with which devices can be fabricated with minimal dependence on specialized laboratory equipment. These devices are often produced using soft lithography techniques to cast replicas of a rigid mold or master incorporating a negative image of the desired surface structures. Conventional photolithographic micromachining processes are typically used to construct these masters in either thick photoresist, etched silicon, or etched glass substrates. The speed at which new masters can be produced using these techniques, however, can be relatively slow and often limits the rate at which new device designs can be built and tested. In this paper, we show that inexpensive photosensitized copper clad circuit board substrates can be employed to produce master molds using conventional printed circuit technology. This process offers the benefits of parallel fabrication associated with photolithography without the need for cleanroom facilities, thereby providing a degree of speed and simplicity that allows microfluidic master molds with well-defined and reproducible structural features to be constructed in approximately 30 min in any laboratory. Precise control of channel heights ranging from 15 to 120 microm can be easily achieved through selection of the appropriate copper layer thickness, and channel widths as small as 50 microm can be reproducibly obtained. We use these masters to produce a variety of plastic-based microfluidic channel networks and demonstrate their suitability for DNA electrophoresis and microfluidic mixing studies.

DNA↗

Microfabricated electrophoresis systems for DNA sequencing and genotyping applications: current technology and future directions.

Many routine genomic-analysis assays rely on gel electrophoresis to perform size-selective fractionation of DNA fragments in the size range below 1 kb in length. Over the past decade, impressive progress has been made towards the development of microfabricated electrophoresis systems to conduct these assays in a microfluidic lab-on-a-chip format. Since these devices are inexpensive, require only nanolitre sample volumes, and do not rely on the availability of a pre-existing laboratory infrastructure, they are readily deployable in remote field locations for use in a variety of medical and biosensing applications. The design and construction of microfabricated electrophoresis devices poses a variety of challenges, including the need to achieve high-resolution separations over distances of a few centimetres or less, and the need to easily interface with additional microfluidic components to produce self-contained integrated DNA-analysis systems. In this paper, we review recent efforts to develop devices to satisfy these requirements and live up to the promise of fulfilling the growing need for inexpensive portable genomic-analysis equipment.

DNA↗

Integrated microsystems for controlled drug delivery.

Efficient drug delivery and administration are needed to realize the full potential of molecular therapeutics. Integrated microsystems that incorporate extremely fast sensory and actuation capabilities can fulfill this need for efficient drug delivery tools. Photolithographic technologies borrowed from the semiconductor industry enable mass production of such microsystems. Rapid prototyping allows for the quick development of customized devices that would accommodate for diverse therapeutic requirements. This paper reviews the capabilities of existing microfabrication and their applications in controlled drug delivery microsystems. The next generation of drug delivery systems--fully integrated and self-regulating--would not only improve drug administration, but also revolutionize the health-care industry.

Chemical Engineering↗

A versatile microfabricated platform for electrophoresis of double- and single-stranded DNA.

We demonstrate a versatile microfabricated electrophoresis platform, incorporating arrays of integrated on-chip electrodes, heaters, and temperature sensors. This design allows a range of different sieving gels to be used within the same device to perform separations involving both single- and double-stranded DNA over distances on the order of 1 cm. We use this device to compare linear and cross-linked polyacrylamide, agarose, and thermo-reversible Pluronic-F127 gels on the basis of gel casting ease, reusability, and overall separation performance using a 100 base pair double-stranded DNA ladder as a standard sample. While cross-linked polyacrylamide matrices provide consistently high-quality separations in our system over a wide range of DNA fragment sizes, Pluronic gels also offer compelling advantages in terms of the ability to remove and reload the gel. Agarose gels offer good separation performance, however, additional care must be exercised to ensure consistent gel properties as a consequence of the need for elevated gel loading temperatures. We also demonstrate the use of denaturing cross-linked polyacrylamide gels at concentrations up to 19% to separate single-stranded DNA fragments ranging in size from 18 to 400 bases in length. Primers differing by 4 bases at a read length of 30 bases can be separated with a resolution of 0.9-1.0 in under 20 min. This level of performance is sufficient to conduct a variety of genotyping assays including the rapid detection of single nucleotide polymorphisms (SNPs) in a microfabricated platform. The ability to use a single microelectrophoresis system to satisfy a wide range of separation applications offers molecular biologists an unprecedented level of flexibility in a portable and inexpensive format.

Acrylic Resins↗

Cross-linked polyacrylamide gel electrophoresis of single-stranded DNA for microfabricated genomic analysis systems.

Microfabricated devices are poised to offer inexpensive self-contained alternatives to conventional benchtop-scale laboratory equipment for performing a variety of important DNA analysis assays. In order to realize the dramatic cost savings possible through photolithographic fabrication techniques, these devices must occupy an extremely compact footprint on the silicon wafer. This requirement implies that electrophoretic separations must be performed over ultrashort distances. Employing cross-linked polyacrylamide gels in place of conventional uncross-linked sieving media offers a convenient strategy to achieve this goal. In this paper, we show how the increased resolving power offered by cross-linked polyacrylamide gels, along with improved sample injection techniques, can be exploited to enhance separation performance in microscale systems. We use these techniques to perform high-resolution gel electrophoresis of single-stranded DNA fragments in microfabricated devices over separation distances of 1.5 cm or less. The results presented here are in agreement with theoretical predictions and suggest that it is possible to perform DNA sequencing on compact microchips. More importantly, the separation performance demonstrated in this work is already more than adequate to perform a number of important genomic assays imposing less stringent resolution requirements than sequencing. Successfully adapting even a few of these assays to the microdevice format has the potential to provide a new generation of inexpensive and portable devices suitable for direct end-user applications.

Acrylic Resins↗

Microdevice-based measurements of diffusion and dispersion in cross-linked and linear polyacrylamide DNA sequencing gels.

We use microfabricated gel electrophoresis devices incorporating integrated on-chip electrodes, heaters, and temperature sensors to measure diffusion and dispersion of single-stranded DNA fragments in cross-linked and uncross-linked polyacrylamide gels. The microdevice format allows a complete set of diffusion and dispersion data to be collected in approximately one hour. These results are compared with corresponding data obtained in a macroscale DNA sequencer, and the effects of gel composition and initiation chemistry are explored. Although the diffusion and dispersion data exhibit similar qualitative trends both on chip and on the macroscale, the magnitudes of the coefficients measured in the microdevice are somewhat higher. This discrepancy is likely due to altered polymerization kinetics arising as a consequence of using a UV-initiated polymerization chemistry to cast the on-chip gels as opposed to the standard chemical polymerization employed on the macroscale. We also find that reductions in the magnitudes of diffusion and dispersion coefficients are achieved at higher polymer concentrations and at operating temperatures in the vicinity of 50 degrees C. Finally, we find that cross-linked polyacrylamide gels yield significantly lower diffusion and dispersion coefficients than linear polyacrylamide. These findings can be used to identify rational strategies to improve separation performance in both micro- and macroscale gel electrophoresis systems.

Cross-Linking Reagents↗