Search PubMed⌕ Search

Biomedical subjects

Valérie Chabbert

Publications and source records attributed to Valérie Chabbert.

15 recordsLinked to original sources

Pulmonary angiomyolipoma.

Extrarenal angiomyolipoma are benign lesions that have rarely been described in the thorax. We present the clinical, radiographic, and pathologic findings of a pulmonary angiomyolipoma in a 63-year-old woman who had no diagnosis of tuberous sclerosis or lymphangioleiomyomatosis. We believe that this report is one of the first descriptions of angiomyolipoma of the lung.

Angiomyolipoma↗

Endovascular repair of traumatic rupture of the aortic isthmus: midterm results.

OBJECTIVE: The endovascular management of aortic traumatic ruptures has been proposed as an alternative to classical surgical procedures. The aim of this work was to report the midterm results of the endovascular treatment of traumatic ruptures of the isthmic aorta. METHODS: Between January 1996 and July 2005, endovascular repair of blunt traumatic aortic ruptures was performed in 33 patients (mean age, 40 +/- 17 years). The stent grafts used were either Talent Medtronic (n = 27), Gore Excluder (n = 4), or Boston Vanguard (n = 2) grafts. Follow-up was 94.9% complete and averaged 32.4 +/- 28.8 months (maximum, 8 years). RESULTS: Stent graft deployment was successful in all cases without need for surgical conversion. Except for one iliac rupture, which was treated with an iliofemoral bypass during the same procedure, there was no major perioperative complication. The early complications consisted of 3 primary endoleaks (1 type I and 2 type IV), 1 transient paraparesis, 1 occlusion of the main left bronchus, 1 thrombosis, and 2 pseudoaneurysms of the brachial artery. All the primary endoleaks healed within the first month. No patient died, and no aortic reinterventions were performed. The midterm complications were a mild circumferential thrombus at the distal part of the stent graft and a fracture of the nitinol stent. Both complications were asymptomatic and were discovered on systematic computed tomographic scan examination. Actuarial freedom from complication at 1 year was 96.1% +/- 3.8% and 85.5% +/- 10.6% at 3 and 5 years, respectively. CONCLUSION: This study demonstrates that the endovascular treatment of blunt thoracic aortic traumatisms is a safe and effective therapeutic method without increased midterm morbidity and mortality rates.

Adult↗

Midterm results of endovascular treatment of atherosclerotic aneurysms of the descending thoracic aorta.

OBJECTIVE: We sought to determine the midterm results of endovascular repair of atherosclerotic aneurysms of the thoracic descending aorta by using second-generation, commercially available stent grafts. METHODS: Between 1996 and 2005, 45 patients (mean age, 68 +/- 11 years) with aneurysms of the descending thoracic aorta underwent endovascular repair. Aortic dissections, penetrating ulcers, and traumatisms were excluded. The mean follow-up was 24.7 +/- 21.6 months (maximum, 6.7 years). RESULTS: No patients died, and no conversion to surgical intervention was required during the procedures. Three (6.7%) patients died during the first month, and 6 (14.7%) died later on. The main complications were strokes (13.3%), vascular access complications (8.9%), aortic complications (6.6%), paraplegia (4.4%), and sudden deaths (4.4%). Nineteen (42%) primary endoleaks were encountered: 3 required reinterventions, 15 spontaneously thrombosed, and 1 patient died. Except for 2 sudden unexplained deaths, no aortic complications were observed after 1 month. Actuarial survival estimates at 1, 3, and 5 years were 87.6% +/- 5.3%, 76.9% +/- 7.4%, and 70.6% +/- 9.2%, respectively. Actuarial freedom from death related to the treated aortic disease was 94.3% +/- 4.0%, 94.3% +/- 4.0%, and 86.4% +/- 8.4% at 1, 3, and 5 years, respectively. Aspirin status of greater than 3 (P = .005), high aortic diameter (P = .007), and long covered lengths (P = .02) were determinant for mortality. Actuarial freedom from complication was 62.6% +/- 7.7%, 58.9% +/- 8.1%, and 58.9% +/- 8.1% at 1, 3, and 5 years, respectively. The location of the aneurysm (P = .05) and a high aortic diameter (P = .04) were both determinants for endoleaks. CONCLUSIONS: Stent grafting of atherosclerotic aneurysm of the thoracic descending aorta is safe and effective. Further studies are mandatory to determine the most relevant indications and the long-term efficacy of such treatment.

Aged↗

[Colonography].

Explore the source record for details and available documents.

Colonoscopy↗

Late perforation of a thoracic aortic dacron graft by a metallic stent-graft component.

PURPOSE: To describe a case involving perforation of a previously placed aortic Dacron graft by the uncovered proximal stent of a thoracic stent-graft. CASE REPORT: A 76-year-old man with a surgically treated type A dissection presented with residual type B dissection. Thoracic stent-grafting of the entry site was performed successfully. After 2 years, the patient was admitted for evaluation of a non-pulsating parasternal mass. Computed tomography showed a large, hypodense liquid-like mass affecting the mediastinum up to the subcutaneous tissue. A false aneurysm at the proximal end of the stent-graft was observed arising from an aortic perforation by the uncovered stent. One week later, the mass had almost completely resolved, and the patient has been scheduled for close surveillance. CONCLUSION: This case illustrated the importance of thoroughly examining the long-term durability and compatibility of prosthetic materials.

Aged↗

Diagnostic management of pulmonary embolism using clinical assessment, plasma D-dimer assay, complete lower limb venous ultrasound and helical computed tomography of pulmonary arteries. A multicentre clinical outcome study.

The objective of the study was to assess the clinical validity of a non-invasive diagnostic strategy for acute pulmonary embolism using clinical assessment combined with both ELISA D-dimer and complete lower limb ultrasound (US) examination of proximal and distal veins, before single-detector helical computed tomography (CT) of pulmonary arteries. We expected the strategy to have a high diagnostic exclusion power and to safely decrease the number of CT scans. This prospective, multicenter outcome study included 274 consecutive outpatients. All underwent a priori clinical probability, D-dimer and bilateral complete lower limb US assessments. Only patients with a high clinical probability and both tests negative, or positive D-dimer and negative US assessments, underwent CT. This was deemed necessary in 114 patients (42%). At baseline, venous thromboembolism (VTE) was detected in 110 patients (40%), either by US showing proximal (n=65) or distal (n=36) thrombosis, or by CT (n=9). Anticoagulant was withheld in the remaining patients with negative results in both D-dimer and US but a non-high clinical probability (n=59), or in both US and CT (n=90), or with negative US (n=6) and inadequate CT (n=9). All patients underwent a three-month clinical follow-up. VTE occurred in one patient with inadequate CT, yielding an incidence of 0.6% [95% confidence interval: 0.1-3.4]. No patient died from VTE or had major bleeding. Using clinical probability, ELISA D-dimer and complete US before helical CT is a safe strategy resulting in a substantial reduction in CT scans.

Adolescent↗

Improved clinical outcome using polytetrafluoroethylene-coated stents for TIPS: results of a randomized study.

BACKGROUND & AIMS: A 50% dysfunction rate at 1 year is one of the main drawbacks of the transjugular intrahepatic portosystemic shunt procedure. Preliminary experimental and clinical studies suggest that the use of stents covered with polytetrafluoroethylene could tremendously decrease this risk. METHODS: Eighty patients with cirrhosis and uncontrolled bleeding (n = 23), recurrent bleeding (n = 25), or refractory ascites (n = 32) were randomized to be treated by transjugular intrahepatic portosystemic shunts with either a polytetrafluoroethylene-covered stent (group 1; 39 patients) or a usual uncovered prosthesis (group 2; 41 patients). Follow-up Doppler ultrasound was scheduled at day 7, at 1 month, and then every 3 months for 2 years. Angiography and portosystemic pressure gradient measurements were performed 6, 12, and 24 months after the transjugular intrahepatic portosystemic shunt procedure and whenever dysfunction was suspected. Dysfunction was defined as a >50% reduction of the lumen of the shunt at angiography or a portosystemic pressure gradient >12 mm Hg. RESULTS: After a median follow-up of 300 days, 5 patients (13%) in group 1 and 18 (44%) in group 2 experienced shunt dysfunction (P < 0.001). Clinical relapse occurred in 3 patients (8%) in group 1 and 12 (29%) in group 2 (P < 0.05). Actuarial rates of encephalopathy were 21% in group 1 and 41% in group 2 at 1 year (not significant). Estimated probabilities of survival were 71% and 60% at 1 year and 65% and 41% at 2 years in groups 1 and 2, respectively (not significant). CONCLUSIONS: The use of polytetrafluoroethylene-covered prostheses improves transjugular intrahepatic portosystemic shunt patency and decreases the number of clinical relapses and reinterventions without increasing the risk of encephalopathy.

Adult↗

Mediastinal lymphadenopathy in congestive heart failure: a sequential CT evaluation with clinical and echocardiographic correlations.

The aim of this study was to evaluate the frequency and evolution after treatment of mediastinal lymphadenopathy associated with congestive left heart failure on CT scans in correlation with clinical and echocardiographic findings. Thirty-one consecutive patients with subacute left heart failure underwent a clinical evaluation using the NYHA classification, a CT examination, and transthoracic echocardiography at the time of initial presentation (T1). After initiation of medical treatment (T2), follow-up CT scans were systematically obtained together with a clinical evaluation. At T1, all patients showed severe (type III: n=12, 39%; type IV: n=12, 39%) to moderate (type I, n=1, 3%; type II, n=6, 19%) dyspnea with a mean ejection fraction of 39% (range 22-74%). On initial CT scans, enlarged mediastinal lymph nodes were seen in 13 patients (42%) with blurred contours in 5 patients (16%) and hazy mediastinal fat in 1 patient (3%). Significant decrease in the size of lymphadenopathy was observed between T1 and T2 (T1, n=13, 42% vs T2, n=10, 32%; p<0.05) with a concurrent decrease in the severity of dyspnea (grade III-IV dyspnea at T1, n=24, 78% vs grade I-II dyspnea at T2, n=26, 83.5%). Patients with enlarged lymph nodes at T1 showed: (a) a significantly lower ejection fraction at echocardiography than those without lymphadenopathy (mean+/-SD value: 34+/-12.9 vs 43+/-13.8%; p=0.04); (b) a significantly larger diameter of the right superior pulmonary vein (mean+/-SD value: 17+/-2.75 vs 14+/-3.9 mm; p=0.04); and (c) a higher frequency of abnormal peribronchovascular thickening ( n=5 vs n=1; p=0.06). Mediastinal lymphadenopathy associated with subacute left heart failure was observed in 13 patients (42%), showing regression after initiation of treatment in 8 of 13 patients (62%).

Aged↗

Midterm outcomes of thoracic aortic stent-grafts: complications and imaging techniques.

PURPOSE: To evaluate the midterm outcomes of thoracic aortic stent-grafting and the performance of computed tomographic angiography (CTA), radiography, and magnetic resonance angiography (MRA) in endograft surveillance. METHODS: Forty-seven patients with traumatic thoracic aortic ruptures (n=16), aneurysms (n=14), false aneurysms (n=3), penetrating ulcers (n=3), and dissections (n=11) treated with stent-grafts were monitored in follow-up using chest radiography and CTA in all patients and MRA in 23 patients. Two perpendicular maximal aortic diameters, the sum of these diameters, and the elliptical cross-sectional area were determined and compared to baseline for the entire group and in subgroup analyses according to lesion type. CTA, MRA, and radiography were compared for their ability to detect endoleak, monitor stent-graft configuration, and measure aortic diameters. RESULTS: The mortality rate was 8.5%. Severe complications were observed in 14.8% (6% neurological complications); 12 (25.5%) patients had primary endoleaks. Over a mean 11-month follow-up (range 0.25-46 months), the aortic diameters decreased for all patients without endoleak (p<0.001). In the diameter/area subgroup analyses, only the traumatic rupture cohort demonstrated significant decreases in all 4 measurements. CTA and MRA measurements correlated well, but chest radiography was superior to both for visualizing stent-graft shape. In terms of endoleak detection, MRA missed only 1 (12.5%) endoleak (type II) seen on CTA; there were no false positive results with MRA. CONCLUSIONS: Morbidity and mortality observed after thoracic stent-grafting are acceptable. Radiography is better for monitoring stent-graft conformation, while CTA provides the best overall morphological information. The performance of MRA in endoleak detection is encouraging.

Adolescent↗

[Imaging of the aorta].

Imaging of the aorta has greatly been improved by the recent development of helical computed tomography and magnetic resonance imaging. This report develops typical features of variety of aortic diseases including dissections, aneurysms, aortic rupture, non aneurismal atherosclerotic diseases, arteritis, aortic coarctation and postoperative aorta. The place for the different imaging modalities is discussed according to the disease involved.

Aortic Dissection↗

Endovascular treatment of aberrant systemic arterial supply to normal basilar segments of the right lower lobe: case report and review of the literature.

We report the case of a 17-year-old man with acute chest pain due to a partial thrombosis of a pseudosequestration. Unlike a true sequestration, there was a normal bronchial distribution and the involved lung parenchyma was normal on CT scan. A therapeutic transarterial embolization of the aberrant systemic artery from the proximal abdominal aorta was performed successfully. The patient did not suffer from further chest pain during the follow-up of 12 months. A contrast-enhanced CT scan 4 months later demonstrated complete occlusion of the embolized aberrant artery. Our case represents an alternative treatment to surgery for this rare abnormality.

Adolescent↗

A useful endovascular technique for treating modular limb disconnection in a bifurcated stent-graft.

PURPOSE: To report a technique for treating a type III endoleak owing to disconnection of an iliac graft limb from a modular aortic stent-graft. TECHNIQUE: A hydrophilic guidewire is introduced via a homolateral femoral access and passed through the thrombosed iliac extension. Once the errant graft limb is recanalized, wire exchange for an extra stiff guidewire facilitates passage of an angioplasty balloon into the stent. Inflated under low pressure, the balloon is used to push the thrombosed limb retrograde into the aneurysm sac. With the aortoiliac axis restored, a new covered stent can be deployed. CONCLUSIONS: This approach is one of several that may be used to treat a type III endoleak arising from a disconnected and occluded stent-graft limb. It avoids the bleeding complications of thrombolysis and restores the aortoiliac axis so that another stent-graft may be implanted to re-exclude the aneurysm.

Aged↗

Preliminary results of a new expanded-polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt procedures.

OBJECTIVE: The purpose of our study was to evaluate the feasibility and the safety of transjugular intrahepatic portosystemic shunts (TIPS) with a new expanded-polytetrafluoroethylene-covered stent and the influence of the covering on occlusion rate. SUBJECTS AND METHODS: Twenty cirrhotic patients (57 +/- 11 years old) admitted with a history of esophageal variceal bleeding (n = 11), refractory ascites (n = 5), or both (n = 4) were included. Five of the patients were treated for TIPS revision, and 15 as de novo TIPS placements. The endoprostheses used were composed of a 2-cm noncovered nitinol stent and a 4- to 8-cm expanded-polytetrafluoroethylene graft covering, and were placed from the portal vein to the ostium of the hepatic vein. Patients underwent Doppler sonography at discharge and again at 1, 3, 6, 9, 12, and 15 months and underwent venography with portosystemic pressure gradient measurement at 6 months and whenever necessary. RESULTS: At the time of this writing, complications included three TIPS restenoses and one recurrent ascites successfully treated by balloon dilation, two cases of segmentary liver ischemia, and one patient with encephalopathy that required shunt reduction. After TIPS placement, the portosystemic pressure gradient dropped from 18 +/- 5 to 5 +/- 4 mm Hg. Primary and secondary patency rates were 80% and 100%, respectively, at 387 days. CONCLUSION: These results clearly show the feasibility of TIPS placement with the Gore TIPS endoprosthesis stent-graft and its improved patency compared with results in the literature for bare stents. These preliminary results must be certified further with randomized comparative trials between covered and noncovered TIPS stents.

Adult↗

Stent-graft treatment of penetrating thoracic aortic ulcers.

PURPOSE: To evaluate the efficacy of stent-graft placement for the treatment of penetrating thoracic aortic ulcers. METHODS: Ten patients (7 men; mean age 73.8 years, range 69-79) were treated for penetrating thoracic aortic ulcers using Talent or Excluder stent-grafts. Preoperative examinations included computed tomographic angiography (CTA), transesophageal echography, and digital subtraction angiography (DSA). Follow-up included predischarge multimodal imaging and periodic CTA scans after discharge. Endoleaks, aortic diameter changes, and clinical complications were tracked. RESULTS: Technical success was achieved in 100%, but 1 major neurological complication led to death 3 months after the procedure. Radiological follow-up detected 4 early, endoleaks (3 type I and a type II), all of which spontaneously regressed, and 1 secondary type II endoleak. The mean aortic diameter decreased by 22% over a mean 9-month follow-up. CONCLUSIONS: Aortic ulcers are potentially lethal lesions. Considering its low morbidity and mortality, endovascular repair could widen the treatment options for these lesions.

Aged↗