Search PubMed⌕ Search

Biomedical subjects

Vadim Backman

Publications and source records attributed to Vadim Backman.

At least 19 recordsLinked to original sources

One chromatin, many structures: From ensemble contact maps to single-cell 3D organization.

Understanding how chromatin folds in three dimensions remains challenging because most experimental assays capture low-dimensional projections of an underlying, highly heterogeneous polymer. Here, we present an ensemble-based interpretive framework built on the previously introduced Self-Returning Excluded Volume (SR-EV) model, a minimal generator of chromatin conformations using a nucleosome-indexed coarse-grained representation based on stochastic return rules and excluded-volume geometry. Despite its simplicity, SR-EV recapitulates key experimental signatures across scales: heterogeneous nanoscale packing domains resembling ChromEMT and ChromSTEM observations, sparse and highly variable single-configuration contact patterns analogous to single-cell chromosome conformation capture (Hi-C), and robust ensemble-level contact enrichment consistent with topologically associating domains (TADs). In this framework, Hi-C loop and TAD signatures are interpreted as ensemble-level statistical enrichments rather than invariant features of single-cell conformations. SR-EV is explicitly designed to generate large ensembles of complete three-dimensional chromatin configurations that can be projected consistently onto two-dimensional contact maps and one-dimensional genomic profiles. By introducing architectural-protein effects only through ensemble selection rather than explicit forces, SR-EV supports a separation between intrinsic polymer geometry and regulatory bias and suggests that TAD-like features can emerge as statistical enrichments rather than deterministic three-dimensional structures. Coordination number and probe-based accessibility computed directly from SR-EV provide a unified link between three-dimensional packing, two-dimensional contact maps, and one-dimensional genomic profiles. The main contribution of this work is to show, within a single coarse-grained framework, how these multimodal observables arise as linked projections of the same heterogeneous chromatin ensemble through averaging and conditional sampling. Together, these results establish SR-EV as a minimal and geometrically grounded mesoscale reference framework for interpreting how heterogeneous chromatin ensembles give rise to multimodal experimental observables while remaining consistent with the fact that chromatin organization is realized in individual cells.

Chromatin↗

Origin of low-coherence enhanced backscattering.

The origin of low-coherence enhanced backscattering (EBS) of light in random media when the spatial coherence length of illumination is much smaller than the transport mean free path has been poorly understood. We report that in weakly scattering discrete random media low-coherence EBS originates from time-reversed paths of double scattering. Low spatial coherence illumination dephases the time-reversed waves outside its finite coherence area, which isolates the minimal number of scattering events in EBS from higher-order scattering. Moreover, we show the first experimental evidence that the minimal number of scattering events in EBS is double scattering, which has been hypothesized since the first observation of EBS.

Algorithms↗

Risk stratification of colon carcinogenesis through enhanced backscattering spectroscopy analysis of the uninvolved colonic mucosa.

INTRODUCTION: Our group has been interested in applying advances in biomedical optics to colorectal cancer risk stratification. Through a recent technological breakthrough, we have been able to harness information from enhanced backscattering spectroscopy, an optics phenomenon that allows quantitative, depth-selective analysis of the epithelial microscale/nanoscale architecture. In the present study, we investigated the ability of enhanced backscattering analysis of the preneoplastic mucosa to predict risk of colon carcinogenesis. METHODS: Enhanced backscattering analysis was done on intestinal mucosa at preneoplastic time points from two experimental models of colorectal cancer: the azoxymethane-treated rat and the multiple intestinal neoplasia (MIN) mouse. Data were analyzed using two previously validated spectral markers: spectral slope and principle components. We then did a pilot study on mucosal biopsies from 63 subjects undergoing screening colonoscopy. RESULTS: In the azoxymethane-treated rat, when compared with saline-treated controls, significant changes in the enhanced backscattering markers were observed as early as 2 weeks after azoxymethane treatment (before the development of aberrant crypt foci and adenomas). Enhanced backscattering markers continued to progress over time in a manner consonant with future neoplasia. These data were replicated in the preneoplastic MIN mouse mucosa. In humans, spectral slopes in the endoscopically normal cecum, midtransverse colon, and rectum were markedly reduced in patients harboring adenomas when compared with those who were neoplasia free. CONCLUSIONS: We show, for the first time, that enhanced backscattering analysis of an aliquot of uninvolved mucosa has the potential for predicting neoplastic risk throughout the colon in both experimental colorectal cancer models and humans.

Animals↗

Backscattering enhancement of light by nanoparticles positioned in localized optical intensity peaks.

We report what we believe to be a novel backscattering phenomenon associated with localized optical intensity peaks (spanning as little as 43 nm) arising at the shadow-side surfaces of plane-wave-illuminated dielectric microcylinders of noncircular cross sections. Namely, for nanometer-scale dielectric particles positioned within the localized intensity peaks, their backscattering of visible light is enhanced by several orders of magnitude relative to the case of isolated nanoparticles (i.e., Rayleigh scattering). The positions of the localized intensity peaks can be quickly scanned along the microcylinder surface by changing either the incident wavelength or angle. This combination of giant backscattering enhancement of nanoparticles and ease and rapidity of scanning may present advantages relative to the use of fragile, mechanically scanned, near-field probes. Potential applications include visible-light detection, characterization, and manipulation of nanoparticles.

Light↗

Highly efficient optical coupling and transport phenomena in chains of dielectric microspheres.

Using the generalized multiparticle Mie theory, we investigate optical coupling and transport through chains of dielectric microspheres. We identify two distinct coupling mechanisms of optical transport in terms of the coupling efficiency between neighboring microspheres, namely, evanescent coupling and nanojet coupling. We demonstrate that perfect whispering gallery mode propagation through a chain of evanescently coupled microspheres can be achieved. However, optical coupling and transport through a chain of nanojet-inducing microspheres is less efficient due to the radiative nature of photonic nanojets. Understanding these two optical coupling mechanisms is critical for selecting appropriate microspheres to build coupled resonator optical waveguides and other photon-manipulation devices for effective and low-loss guiding of photons.

Journal Article↗

Superenhanced backscattering of light by nanoparticles.

We report a physical explanation for the phenomenon wherein the backscattering of light by dielectric particles of sizes between 100 and 1 nm is enhanced by 7-11 orders of magnitude. The phenomenon involves complex composite interactions between a dielectric microsphere and a nanoparticle positioned in close proximity to the microsphere. We provide both analytical and perturbation analyses that show that the enhanced backscattering intensity of a nanoparticle is proportional to the third power of its size parameter. Potential applications of this phenomenon include visible-light detection, characterization, and manipulation of particles as small as a few nanometers.

Biosensing Techniques↗

Assessment of blood supply in superficial tissue by polarization-gated elastic light-scattering spectroscopy.

We report the feasibility of monitoring both hemoglobin oxygen saturation and hemoglobin concentration in the superficial layer of tissue using polarization-gated elastic light-scattering spectroscopy. We detail our analysis technique, the experimental validation of our analysis, and the detection of an early increase in blood supply to the superficial layer of colon tissue in human patients with colonic adenomas as well as in an animal model of colon carcinogenesis. To the best of our knowledge, this study represents the first evidence that polarization gating can be used as a spectroscopic tool to quantify hemoglobin concentration as well as oxygen saturation in the uppermost tissue layer.

Animals↗

Elastic backscattering spectroscopic microscopy.

The spectral properties of elastic light-scattering signals have been shown to provide a wealth of information on nanostructures and microstructures. We present elastic backscattering spectroscopic microscopy that allows simultaneous acquisition of microscopic images and backscattering spectra at each pixel. Within a single homogeneous micrometer-scale particle we observe two distinct and highly localized spectral oscillation features that arise from different optical paths: (1) surface waves (e.g., the ripple structure) and (2) a not previously reported anomalous ripple structure that is due to the interference of waves scattered from front and back surfaces at the particle's center. We also demonstrate that the spectroscopic data can provide nanoscale structural information beyond what conventional microscopy reveals.

Equipment Design↗

Development of a bioengineered tissue model and its application in the investigation of the depth selectivity of polarization gating.

Understanding the propagation of polarized light in tissue is crucial for a number of biomedical optics applications. Here we report the development of a bioengineered connective tissue model fabricated by the combination of scaffolding and cross-linking techniques to study light transport in biological tissue. It demonstrates great similarity to real connective tissue in its optical properties as well as microarchitecture. Moreover, the optical properties of the model can be reproducibly controlled. As an example, we report the utilization of this model to study the effect of epithelium and the underlying connective tissue on the depth selectivity of polarization gating.

Animals↗

Quantitative analysis of depolarization of backscattered light by stochastically inhomogeneous dielectric particles.

We determine the relationship between the depolarization properties of inhomogeneous particles and the statistical parameters of their internal refractive-index distributions. Our analysis demonstrates that the linear depolarization ratio of backscattered light by an inhomogeneous particle is approximately proportional to both the squared standard deviation and the squared correlation length of the particle's internal refractive-index distribution. We verify this result by conducting rigorous numerical studies using the finite-difference time-domain method. This improved understanding of light depolarization by inhomogeneous structures may enhance polarization-based biomedical optical imaging techniques.

Journal Article↗

Depth-resolved low-coherence enhanced backscattering.

The phenomenon of enhanced backscattering (also known as coherent backscattering), an object of substantial scientific interest, has awaited application to tissue optics for the past two decades. Here we demonstrate, for the first time to our knowledge, depth-resolved spectroscopic elastic light scattering measurements in tissue by use of low-coherence enhanced backscattering (LEBS). We achieve the depth resolution by exploiting the nature of the LEBS peak that contains information about a wide range of tissue depths. We further demonstrate that depth-resolved LEBS spectroscopy has the potential to identify the origin of precancerous transformations in the colon at an early, previously undetectable stage.

Adenoma↗

Low-coherent backscattering spectroscopy for tissue characterization.

Although the phenomenon of coherent backscattering (CBS) in nonbiological media has generated substantial research interest, observing CBS in biological tissue has been extremely difficult. Here we show that the combination of low-spatial-coherence, broadband illumination, and low-temporal-coherence, spectrally resolved detection significantly facilitates CBS observation in biological tissue and other random media with long-transport mean-free path lengths, which have been previously beyond the reach of conventional CBS investigations. Furthermore, we demonstrate that depth-selective, speckle-free, low-coherent backscattering spectroscopy has the potential to diagnose the earliest, previously undetectable, precancerous alterations in the colon by means of probing short light paths.

Animals↗

Exact solution of Maxwell's equations for optical interactions with a macroscopic random medium: addendum.

This Addendum provides a revised set of figures containing converged numerical data for total scattering cross section (TSCS), replacing the figures in our recent publication [Opt. Lett. 29, 1393 (2004)]. Due to the use of an overly large time step, our original TSCS data exhibited a systematic, nonphysical diminution above 150 THz for all cases studied. We have determined that numerical convergence in the temporal sense for the pseudospectral time-domain (PSTD) algorithm employed previously requires limiting the time step to no more than 1/60th of the sinusoidal period at the maximum frequency of interest, which in the previous case was 300 THz. This is an important point that we hereby report to future users of PSTD simulations in electrodynamics and optics. Note that all our original conclusions remain valid.

Algorithms↗

Spectral markers in preneoplastic intestinal mucosa: an accurate predictor of tumor risk in the MIN mouse.

BACKGROUND: We have reported recently that microarchitectural analysis of the histologically normal mucosa using a novel optics technology, four-dimensional elastic light scattering fingerprinting (ELF), provided unprecedented sensitivity for early detection of colon carcinogenesis. In the present study, we explored the ability of four-dimensional ELF to identify an inherited predisposition to colorectal cancer, an issue of considerable importance for optimizing population screening strategies. METHODS: We used the MIN mouse, a model whose germ line adenomatous polyposis coli truncation leads to spontaneous intestinal tumorigenesis, thus replicating the human syndrome, familial adenomatous polyposis. Spectral markers were assessed by four-dimensional ELF analysis in MIN mice at preneoplastic time points and compared with age-matched controls (C57BL6 mice with wild-type adenomatous polyposis coli). To assess the responsiveness of spectral markers to chemopreventive agents, a subset of MIN mice was supplemented with celecoxib 1,500 ppm. RESULTS: Spectral slope, fractal dimension, and principal component 3 were dramatically altered in the uninvolved MIN mouse mucosa at the earliest time points. Furthermore, alteration in spectral variables increased over time, consonant with the microarchitectural underpinnings of subsequent tumorigenesis. Additionally, these markers spatially correlated with future adenoma development (small intestine > colon). Short-term treatment with the potent chemopreventive agent, celecoxib, resulted in near normalization of fractal dimension and principal component 3. CONCLUSIONS: We report, for the first time, that spectral markers, assayed by four-dimensional ELF, were able to sensitively identify a genetic predisposition for intestinal tumorigenesis before the occurrence of phenotypic manifestations. Moreover, the reversal of spectral markers by celecoxib treatment supports the neoplastic relevance.

Animals↗

Equiphase-sphere approximation for light scattering by stochastically inhomogeneous microparticles.

We report the development and validation of the equiphase-sphere (EPS) approximation for calculating the total-scattering cross-section (TSCS) spectra of inhomogeneous microparticles having complex interior structures. We show that this closed-form, analytical approximation can accurately model the TSCS of randomly inhomogeneous spherical particles having internal refractive index variations with geometrical scales spanning from nanometers (i.e., subwavelength) to microns (i.e., suprawavelength). Moreover, we derive an easy-to-use criterion for the range of validity of the EPS approximation in modeling TSCS of inhomogeneous particles. The work discussed in this paper may positively impact tissue optical imaging and diagnostic applications.

Journal Article↗

Coherent backscattering spectroscopy.

Coherent backscattering (CBS) of light in random media has been previously investigated by use of coherent light sources. Here we report a novel method of CBS measurement that combines low spatial coherence, broadband illumination, and spectrally resolved detection. We show that low spatial coherence illumination leads to an anomalously broad CBS peak and a dramatic speckle reduction; the latter is further facilitated by low temporal coherence detection. Thus CBS can be observed in biological tissue and other media that previously were beyond the reach of conventional CBS measurements. We also demonstrate, for the first time to our knowledge, spectroscopic analysis of CBS. CBS spectroscopy may find important applications in probing random media such as biological tissue in which depth-selective measurements are crucial.

Animals↗

Equiphase-sphere approximation for analysis of light scattering by arbitrarily shaped nonspherical particles.

We extend the previously proposed concept of equiphase sphere (EPS) to analyze light-scattering properties of arbitrarily shaped particles. Our analyses based on the Wentzel-Kramers-Brillouin technique and numerical studies based on the finite-difference time-domain method demonstrate that a wide range of irregularly shaped particles can be approximated as their equivalent equiphase ellipsoids to determine their total scattering cross-section (TSCS) spectra. As a result, a simple expression given by the EPS approximation can be used to calculate the TSCS spectra of these particles. We find that the accuracy of the EPS approximation is influenced by both the magnitude and the geometric scale of the surface perturbation of the particle, and we derive validity conditions of the EPS approximation to guide the practical application of this method.

Journal Article↗

Exact solution of Maxwell's equations for optical interactions with a macroscopic random medium.

We report what we believe to be the first rigorous numerical solution of the two-dimensional Maxwell equations for optical propagation within, and scattering by, a random medium of macroscopic dimensions. Our solution is based on the pseudospectral time-domain technique, which provides essentially exact results for electromagnetic field spatial modes sampled at the Nyquist rate or better. The results point toward the emerging feasibility of direct, exact Maxwell equations modeling of light propagation through many millimeters of biological tissues. More generally, our results have a wider implication: Namely, the study of electromagnetic wave propagation within random media is moving toward exact rather than approximate solutions of Maxwell's equations.

Computer Simulation↗