Three-point transformation for integration of multiple coordinate systems: applications to tumor, functional, and fractionated radiosurgery stereotactic planning.

The accuracy of an optimized three-point transformation method and its usefulness for integrating multiple independent coordinate systems has been described. Such integration can be implemented to accomplish complex stereotactic procedures which may require the use of multiple image data sets and combinations of frame-based and frameless stereotactic systems. This report details the application of an optimized transformation for intracranial lesion biopsy and/or resection, radiofrequency pallidotomy for treatment of Parkinson's disease, and fractionated stereotactic radiosurgery in a total of 68 patients. For approach to intracranial lesions, a noninvasive definition of image coordinate systems with multiple radiodense scalp markers was cross-registered with a standard stereotactic guidance system. This method allowed for elective acquisition of stereotactic image sets without requiring head frame fixation until the time of the operative procedure. In planning pallidotomy procedures, spatial cross-registration of CT and MR image coordinates were performed to target the posteroventral pallidum. CT coordinates were defined by the standard picket fence algorithm while MR images were referenced with multiple scalp markers. The addition of MR data sets improved anatomic resolution in the regions of the basal ganglia and commissures. Fractionated radiosurgery was accomplished by cross-registration of CT, MR, and plain radiographs using BRW localizers coupled with multiple scalp markers. A daily check of target positioning was performed with the BRW angiograph localizer. The average calculated error was 2.83 mm with a standard deviation of 1.66 mm which remained within the average scan slice thickness of 3.63 mm. In all cases surgical targets were reached without complication.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Preliminary experience using an optimized three-point transformation algorithm for spatial registration of coordinate systems: a method of noninvasive localization using frame-based stereotactic guidance systems.

This study describes the use of an optimized three-point transformation algorithm to spatially cross-register a volumetric computerized tomographic scan or magnetic resonance image data set with the coordinate system of a stereotactic frame. This algorithm was tested for accuracy using a scanned phantom in which calculated targets, using the Brown-Roberts-Wells (BRW) frame picket-fence algorithm as a standard, could be compared to physical targets measured using a BRW arc and phantom. These target values were then compared to target values calculated with the optimized three-point algorithm. This method was used for target localization in 21 patients. Following this noninvasive localization method, the standard BRW stereotactic system was used for guidance. The application accuracy of this frameless localization technique was within the limits of the scan slice thickness in 16 of 21 cases, with an average error of 2.11 mm in an average scan slice thickness of 3.1 mm. Intracranial targets were successfully reached in all cases without morbidity or mortality. The algorithm can be customized to cross-register image data sets with the coordinate systems of a wide variety of stereotactic guidance systems. The method increases the convenience and flexibility of frame-based stereotactic guidance by providing a means of noninvasive localization that can be accomplished electively at a separate time from the guidance part of a stereotactic operative procedure.

Aged