Melanosis (haemosiderosis) ilei.

We report here a case of melanosis ilei where grossly visible greyish black pigmentation of the ileal mucosa was discovered at autopsy. Light microscopy showed Prussian blue positive pigment granules in macrophages in the lamina propria forming the core of villi. Ultrastructural examination showed that the pigment granules had the morphology of siderosomes which are known to be the electron microscopic equivalent of the haemosiderin granules seen with the light microscope. We know of no previous report where pigmentation of the ileal mucosa was ascribed to the presence of haemosiderin.

Aged↗

Splenic rupture resulting from acute pancreatitis after cardiac surgery with intra-aortic balloon pumping: case report.

A very unusual cause of splenic rupture is described in a 73-year-old man with severe coronary artery disease. A transthoracic intra-aortic balloon pump (IABP) was inserted during coronary artery bypass grafting and was used for 3 days. However, his hypotension continued, and ischemic changes in his hand were thought to be due to the use of the pump. He died 7 days later of cardiac arrest. Autopsy revealed multiorgan failure associated with a preoperative myocardial infarct. Numerous systemic arterial atheroemboli, likely resulting from IABP-related aortic trauma and hypotension, had given rise to severe acute pancreatitis. The necrotizing process within the pancreatic tail had extended to the splenic hilum, eroding its capsule and causing splenic rupture and hemoperitoneum.

Acute Disease↗

Cicatricial changes in a Ionescu-Shiley bioprosthesis.

The mitral Ionescu-Shiley standard-profile prosthesis of a 53-year-old woman who had it placed 12 years previously is described. The observed cicatricial retraction of one of the bioprosthesis' cusps is unusual, and it contributed to the bioprosthetic dysfunction which necessitated this valve's replacement.

Aortic Valve↗

Massive cardiac deposits of AL-amyloid in a patient with previous valve replacement.

A 78-year old male with AL-type cardiac amyloidosis is presented. Amyloidosis had not been diagnosed during life, as the patient's complaints had been incorrectly ascribed to failure of a Ionescu-Shiley bovine pericardial bioprosthesis inserted seven years previously. Technical considerations relevant to the correct interpretation of echocardiograms in this setting are reviewed. The unique observation of incidental involvement the bioprosthesis by deposits of the Al-amyloid is described.

Aged↗

Congenitally bicuspid aortic valves: study of a variant with fenestrated raphe.

OBJECTIVE: To illustrate and describe a variant of the congenitally bicuspid aortic valve (BAV) in the context of previous reports of the morphology of BAVs. SETTING: Retrospective review of surgically excised aortic valves at The University of Ottawa Heart Institute in Ottawa, Ontario. DESIGN AND PATIENTS: The clinical, echocardiographic and pathological features of 17 cases with a variant of BAV were examined from patients who had valve replacements performed in the period from January 1, 1986 to December 31, 1992. MAIN RESULTS: A total of 865 patients had native aortic valve replacements during the study period and 291 patients had BAVs. One hundred and eighty-one patients were male (62%) (mean age 60 years) and 110 were female (38%) (mean age 64 years). There were 17 BAVs (6%) where either: the raphe was fenestrated so that only a thin fibrous band (or bands) joined the valve cusp to aortic wall-type A valves (seven cases); or a similar fibrous band (or bands) was seen, but was associated with other usual appearing raphal tissue--type B valves (10 cases). These patients included 15 males (mean age 63 years) and two females (mean age 63 years); they presented with dyspnea and/or angina. Distinction of the number of cusps with this variant was incorrect in six of nine transthoracic echocardiograms, and three of four transesophageal echocardiograms. CONCLUSION: This variant of BAV, with fenestrated raphe, is not well described in the literature, is difficult to diagnose clinically and may present in unusual ways.

Aged↗

Pathology of radiofrequency catheter ablation of the atrioventricular node.

Catheter ablation of the atrioventricular node is now the treatment of choice for definitive management of some supraventricular tachyarrhythmias. Radiofrequency current is used as the energy source in most centers. We describe a 67-year-old woman who had rheumatic mitral valve disease and chronic atrial fibrillation with rapid ventricular response. She underwent successful radiofrequency catheter ablation of the atrioventricular node, followed by permanent pacemaker insertion. She required mitral valve replacement 16 months later and died postoperatively of left ventricular failure. At autopsy, there were patches of organized endocardial thrombus and discrete endocardial and myocardial fibrous scar at the ablation sites, replacing most of the atrioventricular node. The long-term pathologic changes after atrioventricular node ablation with radiofrequency current, used in a clinical setting, have not been previously described and are illustrated here.

Aged↗

Intra-atrial course of the right coronary artery and its branches.

OBJECTIVE: To illustrate and describe an anomaly of right coronary artery (RCA) course. SETTING: Postmortem examination of cardiac tissue. DESIGN AND PATIENTS: Three cases where the RCA had an intracavitary position in the right atrium are described. Additionally, light microscopic analysis of random sections of posterior right atrium from 100 consecutive autopsy cases was undertaken. MAIN RESULTS: Each of the index cases was an incidental finding at autopsy. In two cases, the RCA, after passing the acute angle of the heart (epicardially), entered the right atrium posteriorly and ran subendocardially for distances of 1.5 and 3.0 cm, respectively. In the third case, the RCA entered the right atrial cavity 2.5 cm from its origin and ran subendocardially for 2.0 cm. In all three cases, the RCA exited the atrial cavity and once again attained an epicardial course. In the first two cases, the RCA ran 1.0 cm above the atrioventricular groove, rather than in its normal location at the annulus. The random sections of right atrial wall showed that medium calibre arterial branches of the RCA also commonly run in subendocardial positions (29 of 100 cases) and sometimes project into the atrial cavity (five of 29 cases). CONCLUSIONS: The genesis of this epicardial coronary anomaly is unclear, but may relate to the 'higher' than normal course of the artery in these cases, in concert with the normal thinness of the right atrial wall, and the tendency for even medium calibre arteries to assume this subendocardial location. Despite the benign outcome of the index cases described here, the authors believe that this intracavitary course of the RCA could pose special technical problems during coronary artery catheterization and bypass grafting.

Aged↗

Retrograde dislodgement of a Harken mitral valve disc occluder.

The previous generation of mechanical heart valves was unfortunately prone to disc variance, dislodgement and catastrophic failure. This is illustrated by the recent case of a 59-year-old male who presented with retrograde dislodgement of a Harken mitral valve disc 20 years after implantation. Expediency in diagnosis and implementing surgical therapy are the keys to success in these patients.

Echocardiography↗

A comparison of the ultrastructure of pigment granules in melanosis ilei and pulmonary lymph nodes.

Two cases of melanosis ilei were studied, in which grossly visible blackish pigmentation of the ileal mucosa was incidentally discovered at autopsy. Light microscopy showed that the pigment granules lay within macrophages in atrophic Peyer's patches. Ultrastructural studies showed that the pigment granules were heterolysosomes containing crystalline material, particles, granules and, occasionally, lipid droplets. The morphological similarity between these pigment granules and granules in pulmonary macrophages was established through ultrastructural studies of pulmonary lymph nodes obtained during routine autopsies. These data, plus results of past electron-probe X-ray analytic studies by us and others, leads us to conclude that the pigment granules in melanosis ilei contain exogenous material derived from inspired and ingested materials.

Adult↗

Neuroendocrine response to cardiac transplantation.

OBJECTIVE: The neuroendocrine response to heart transplantation was characterized in 11 patients with special reference to long term effects on plasma hormone concentration. DESIGN: Multiple serial measurements of preload, ejection fraction, plasma renin activity (PRA), aldosterone, atrial natriuretic factor (ANF) and catecholamines were made over time. SETTING: Tertiary care cardiac referral, university-based centre. PATIENTS: Eleven adult patients undergoing orthotopic cardiac transplantation were studied. The group consisted of 10 males and one female (mean age 52 +/- 2 years). Eight patients had coronary atherosclerosis, two had idiopathic cardiomyopathy and one had valvular heart disease. All patients were in end-stage heart failure (Canadian Cardiovascular Society class IV) and two also had angina. INTERVENTIONS: Right heart catheterization and hormonal assays in blood were performed simultaneously preoperatively and postoperatively at 24 h, 48 h and during each endomyocardial biopsy. An endomyocardial biopsy to detect rejection was performed weekly for two to four weeks, then every three to four months at one year postoperatively. Hemodynamic measurements included central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP). Ejection fraction was measured in each patient using radionuclide ventriculography preoperatively and serially through the postoperative period. MAIN RESULTS: Following transplantation, transient elevation of intracardiac filling pressures occurred. The CVP and PCWP were elevated at 15 +/- 2 and 17 +/- 1 mmHg, respectively, early postoperatively (ie, days 2 to 30 postsurgery). Late postoperatively (ie, more than 30 days postoperatively), the CVP and PCWP decreased to 8 +/- 1 and 12 +/- 1 mmHg, respectively. Systolic function, as measured by radionuclide ejection fraction, did not change significantly from the early to the late postoperative period (60 +/- 5% early versus 59 +/- 2% late postoperatively). PRA and plasma aldosterone fell in association with the decrease in filling pressures (PRA was 2.4 +/- 0.8 ng/mL/h early versus 1.0 +/- 0.2 ng/ml/h late; plasma aldosterone was 122 +/- 31 pg/mL early versus 103 +/- 16 pg/mL late). Plasma aldosterone levels were similar in the early and late postoperative periods, except during the first day after surgery during which a transient elevation occurred. ANF remained markedly elevated despite the fall in filling pressures (323 +/- 50 pg/mL preoperatively, 360 +/- 33 pg/mL early postoperatively and 322 +/- 31 pg/mL late postoperatively). CONCLUSIONS: The authors conclude that transient cardiac dysfunction occurs following cardiac transplantation with elevation of filling pressures and continued increased activity of the renin-angiotensin-aldosterone system (RAAS) and elevated plasma ANF levels. With return of cardiac function and normalization of filling pressures, the activity levels of the RAAS decrease, but not those of ANF, which remain chronically abnormally elevated. It is not clear whether this persistent elevation of ANF is the result of factors related to the transplant procedure, such as extrinsic denervation or antirejection therapy, among others, or is the persistence of factors acting preoperatively. However, known interactions of cyclosporine with vascular smooth muscle and endothelial cells leading to increased sensitivity to vasopressor hormones and increased circulating levels of endothelin appear as the most likely explanation for the chronic elevation of ANF plasma levels. In this context, ANF may play a key role in moderating the side effects of cyclosporine treatment.

Aldosterone↗

Laser Raman spectrum of calcified human aorta.

Raman spectra of highly calcified areas of human aorta were obtained using long wavelength excitation at 740 nm to minimize background fluorescence interference. Raman spectra resembling that of hydroxyapatite were obtained for segments of highly calcified aorta that were thawed frozen samples, from which the surface layer had been removed, or were dried. These are the first reported spectra obtained in air or in normal saline solution showing the hydroxyapatite peak in calcified plaque for samples which were untreated except for freezing, which is encouraging for the application of Raman spectroscopy as a method of detection of plaque during laser angioplasty. Spectra obtained from calcified aorta using excitation at 514.5 nm did not show evidence of the hydroxyapatite band because of the severe interference by background fluorescence generated at this wavelength.

Aortic Diseases↗

Ionescu-Shiley valve failure. I: Experience with 125 standard-profile explants.

A group of standard-profile Ionescu-Shiley valve implants, 357 aortic and 190 mitral, was reviewed for cases of failure requiring surgical explantation. To date, 90 (25.2%) of the aortic and 35 (18.4%) of the mitral valves have failed, and are the subject of this analysis. Observations of these explants confirm previous suggestions about the clinical and pathologic patterns of the Ionescu-Shiley valve's failure, but are extended in this study to allow more confident statistical analyses. Cusp tear with insufficiency remains the most important reason for explantation, precipitating removal to date of 19.1% of the aortic and 10.0% of the mitral valves implanted. This difference, aortic versus mitral, is significant (p less than 0.006) and the reverse of observations made in other studies of pericardial valves. In this review there is no significant difference in the proportion of aortic and mitral valves that failed with calcification (2.2% and 3.1%, respectively). Aortic Ionescu-Shiley valves failing with tears had a mean of 3.1 tears per valve, whereas mitral valves had 1.2. Aortic valves also showed considerably more pretear wear than did mitral valves. Although the large number of these Ionescu-Shiley valve failures has been a profound clinical disappointment, it has provided an opportunity to observe and detail the pathology of their failure.

Adolescent↗

Ionescu-Shiley valve failure. II: Experience with 25 low-profile explants.

A group of patients who had low-profile Ionescu-Shiley valves implanted, 237 aortic and 130 mitral, was reviewed for cases of bioprosthetic failure requiring explantation. Fourteen such aortic and 11 mitral valves were recovered at operation. The most common reason for explantation was valvular insufficiency due to cusp tears, accounting for 50.0% of aortic and 82.0% of mitral explants. Morphologic examination of the valves suggested a common mode of failure with tears, and this is illustrated. The clinical and pathologic patterns of this valve's failure are compared with those of the standard-profile Ionescu-Shiley valve, and many similarities exist. A tendency for a larger proportion of mitral valve failures with tears is, however, in contrast to observations of the standard-profile valve, in which aortic failures are more common. Additionally, low-profile valves, in either the aortic or mitral positions, fail after a shorter time in situ than their standard-profile counterparts, at a mean of 45.1 months versus 78.0 in the aortic position (p less than 0.01) and at 52.2 months versus 73.8 in the mitral position (p less than 0.05). These differences in the performance of the Ionescu-Shiley valve models may have implications for the design of future bioprostheses.

Adult↗